add back command for remoteseltemp #1982

This commit is contained in:
MichaelDvP
2024-09-06 16:52:12 +02:00
parent d7a4f4af00
commit d31eb3d606

View File

@@ -4482,8 +4482,15 @@ void Thermostat::register_device_values_hc(std::shared_ptr<Thermostat::HeatingCi
MAKE_CF_CB(set_tempautotemp),
-1,
30);
register_device_value(tag, &hc->remoteseltemp, DeviceValueType::INT8, DeviceValueNumOp::DV_NUMOP_DIV2, FL_(remoteseltemp), DeviceValueUOM::DEGREES);
// a command is only accepted from the remote device, not from ems-esp.
register_device_value(tag,
&hc->remoteseltemp,
DeviceValueType::INT8,
DeviceValueNumOp::DV_NUMOP_DIV2,
FL_(remoteseltemp),
DeviceValueUOM::DEGREES,
MAKE_CF_CB(set_remoteseltemp),
-1,
30);
register_device_value(tag, &hc->fastHeatup, DeviceValueType::UINT8, FL_(fastheatup), DeviceValueUOM::PERCENT, MAKE_CF_CB(set_fastheatup));
register_device_value(tag,
&hc->switchonoptimization,