added EMS_BOILER_TAPWATER_TEMPERATURE_MAX to my_config.h, not all boilers support 90 degrees max
changed tapwater detection mechanism: - added EMS_BOILER.wWCurFlow to be read from 0x34 messages, this gives the current amount of tapwater flowing in dl/min - added wWCurFlow to mqtt message - added wWCurFlow to telnet statistics changed detection from: selBurnPow and selFlowTemp to wWCurFlow added the current servicecode as seen on thermostat and boieler display to telnet statistics and mqtt message
This commit is contained in:
14
src/ems.cpp
14
src/ems.cpp
@@ -176,6 +176,8 @@ void ems_init() {
|
||||
EMS_Boiler.curBurnPow = EMS_VALUE_INT_NOTSET; // Burner current power
|
||||
EMS_Boiler.flameCurr = EMS_VALUE_FLOAT_NOTSET; // Flame current in micro amps
|
||||
EMS_Boiler.sysPress = EMS_VALUE_FLOAT_NOTSET; // System pressure
|
||||
EMS_Boiler.serviceCodeChar1 = EMS_VALUE_INT_NOTSET; //
|
||||
EMS_Boiler.serviceCodeChar2 = EMS_VALUE_INT_NOTSET; //
|
||||
|
||||
// UBAMonitorSlow
|
||||
EMS_Boiler.extTemp = EMS_VALUE_FLOAT_NOTSET; // Outside temperature
|
||||
@@ -190,6 +192,7 @@ void ems_init() {
|
||||
EMS_Boiler.wWStarts = EMS_VALUE_INT_NOTSET; // Warm Water # starts
|
||||
EMS_Boiler.wWWorkM = EMS_VALUE_INT_NOTSET; // Warm Water # minutes
|
||||
EMS_Boiler.wWOneTime = EMS_VALUE_INT_NOTSET; // Warm Water one time function on/off
|
||||
EMS_Boiler.wWCurFlow = EMS_VALUE_INT_NOTSET;
|
||||
|
||||
EMS_Boiler.tapwaterActive = EMS_VALUE_INT_NOTSET; // Hot tap water is on/off
|
||||
EMS_Boiler.heatingActive = EMS_VALUE_INT_NOTSET; // Central heating is on/off
|
||||
@@ -723,8 +726,8 @@ void _processType(uint8_t * telegram, uint8_t length) {
|
||||
bool _checkActive() {
|
||||
// hot tap water
|
||||
EMS_Boiler.tapwaterActive =
|
||||
((EMS_Boiler.selFlowTemp == 0)
|
||||
&& (EMS_Boiler.selBurnPow >= EMS_BOILER_BURNPOWER_TAPWATER) & (EMS_Boiler.burnGas == EMS_VALUE_INT_ON));
|
||||
((EMS_Boiler.wWCurFlow != 0) //this is easier
|
||||
&& (EMS_Boiler.burnGas == EMS_VALUE_INT_ON));
|
||||
|
||||
// heating
|
||||
EMS_Boiler.heatingActive =
|
||||
@@ -754,6 +757,7 @@ void _process_UBAMonitorWWMessage(uint8_t * data, uint8_t length) {
|
||||
EMS_Boiler.wWStarts = _toLong(13, data);
|
||||
EMS_Boiler.wWWorkM = _toLong(10, data);
|
||||
EMS_Boiler.wWOneTime = bitRead(data[5], 1);
|
||||
EMS_Boiler.wWCurFlow = data[9];
|
||||
}
|
||||
|
||||
/**
|
||||
@@ -778,6 +782,10 @@ void _process_UBAMonitorFast(uint8_t * data, uint8_t length) {
|
||||
|
||||
EMS_Boiler.flameCurr = _toFloat(15, data);
|
||||
|
||||
//read the service code / installation status as appears on the display
|
||||
EMS_Boiler.serviceCodeChar1 = data[18]; //ascii character 1
|
||||
EMS_Boiler.serviceCodeChar2 = data[19]; //ascii character 2
|
||||
|
||||
if (data[17] == 0xFF) { // missing value for system pressure
|
||||
EMS_Boiler.sysPress = 0;
|
||||
} else {
|
||||
@@ -1187,7 +1195,7 @@ void ems_setThermostatMode(uint8_t mode) {
|
||||
*/
|
||||
void ems_setWarmWaterTemp(uint8_t temperature) {
|
||||
// check for invalid temp values
|
||||
if ((temperature < 30) || (temperature > 90)) {
|
||||
if ((temperature < 30) || (temperature > EMS_BOILER_TAPWATER_TEMPERATURE_MAX)) {
|
||||
return;
|
||||
}
|
||||
|
||||
|
||||
Reference in New Issue