Merge pull request #1150 from minusdreidb/dev

Fix #1147 - Exhaust temperature always zero on GB125/MC110/RC310
This commit is contained in:
Proddy
2023-04-02 10:43:35 +02:00
committed by GitHub

View File

@@ -1032,6 +1032,8 @@ void Boiler::process_UBAMonitorFastPlus(std::shared_ptr<const Telegram> telegram
//has_update(telegram, temperatur_, 13); // unknown temperature //has_update(telegram, temperatur_, 13); // unknown temperature
//has_update(telegram, temperatur_, 27); // unknown temperature //has_update(telegram, temperatur_, 27); // unknown temperature
has_update(telegram, exhaustTemp_, 31);
// read 3 char service code / installation status as appears on the display // read 3 char service code / installation status as appears on the display
if ((telegram->message_length > 3) && (telegram->offset == 0)) { if ((telegram->message_length > 3) && (telegram->offset == 0)) {
char serviceCode[4] = {0}; char serviceCode[4] = {0};
@@ -1096,7 +1098,7 @@ void Boiler::process_UBAMonitorSlowPlus(std::shared_ptr<const Telegram> telegram
has_bitupdate(telegram, ignWork_, 2, 3); has_bitupdate(telegram, ignWork_, 2, 3);
has_bitupdate(telegram, heatingPump_, 2, 5); has_bitupdate(telegram, heatingPump_, 2, 5);
has_bitupdate(telegram, wwCirc_, 2, 7); has_bitupdate(telegram, wwCirc_, 2, 7);
has_update(telegram, exhaustTemp_, 6); // has_update(telegram, exhaustTemp_, 6); // Disabled until verified as valid location, see #1147.
has_update(telegram, burnStarts_, 10, 3); // force to 3 bytes has_update(telegram, burnStarts_, 10, 3); // force to 3 bytes
has_update(telegram, burnWorkMin_, 13, 3); // force to 3 bytes has_update(telegram, burnWorkMin_, 13, 3); // force to 3 bytes
has_update(telegram, burn2WorkMin_, 16, 3); // force to 3 bytes has_update(telegram, burn2WorkMin_, 16, 3); // force to 3 bytes