Merge branch 'emsesp:dev' into dev

This commit is contained in:
pswid
2022-11-08 15:21:39 +01:00
committed by GitHub
2 changed files with 11 additions and 20 deletions

View File

@@ -851,11 +851,11 @@ void Boiler::process_UBAParameterWW(std::shared_ptr<const Telegram> telegram) {
// has_bitupdate(telegram, wwEquipt_,0,3); // 8=boiler has ww
has_update(telegram, wwActivated_, 1); // 0xFF means on
has_update(telegram, wwSelTemp_, 2);
has_update(telegram, wwHystOn_, 3); // Hyst on (default -5)
has_update(telegram, wwHystOff_, 4); // Hyst off (default -1)
has_update(telegram, wwFlowTempOffset_, 5); // default 40
has_update(telegram, wwCircPump_, 6); // 0xFF means on
has_update(telegram, wwCircMode_, 7); // 1=1x3min 6=6x3min 7=continuous
has_update(telegram, wwHystOn_, 3); // Hyst on (default -5)
has_update(telegram, wwHystOff_, 4); // Hyst off (default -1)
has_update(telegram, wwFlowTempOffset_, 5); // default 40
has_update(telegram, wwCircPump_, 6); // 0xFF means on
has_enumupdate(telegram, wwCircMode_, 7, 1); // 1=1x3min 6=6x3min 7=continuous
has_update(telegram, wwDisinfectionTemp_, 8);
has_bitupdate(telegram, wwChargeType_, 10, 0); // 0 = charge pump, 0xff = 3-way valve
@@ -1028,7 +1028,7 @@ void Boiler::process_UBAParameterWWPlus(std::shared_ptr<const Telegram> telegram
has_update(telegram, wwHystOff_, 8);
has_update(telegram, wwFlowTempOffset_, 9);
has_update(telegram, wwCircPump_, 10); // 0x01 means yes
has_update(telegram, wwCircMode_, 11); // 1=1x3min... 6=6x3min, 7=continuous
has_enumupdate(telegram, wwCircMode_, 11, 1); // 1=1x3min... 6=6x3min, 7=continuous
has_update(telegram, wwDisinfectionTemp_, 12); // setting here, status in E9
has_update(telegram, wwSelTempSingle_, 16);
has_update(telegram, wwSelTempLow_, 18);
@@ -2188,24 +2188,15 @@ bool Boiler::set_ww_circulation_pump(const char * value, const int8_t id) {
// Set the mode of circulation, 1x3min, ... 6x3min, continuous
// true = on, false = off
bool Boiler::set_ww_circulation_mode(const char * value, const int8_t id) {
int v;
if (!Helpers::value2number(value, v)) {
return false;
}
if (v < 7) {
// LOG_INFO("Setting dhw circulation mode %dx3min", v);
} else if (v == 7) {
// LOG_INFO("Setting dhw circulation mode continuous");
} else {
// LOG_WARNING("Set dhw circulation mode: Invalid value");
uint8_t v;
if (!Helpers::value2enum(value, v, FL_(enum_freq))) {
return false;
}
if (is_fetch(EMS_TYPE_UBAParameterWWPlus)) {
write_command(EMS_TYPE_UBAParameterWWPlus, 11, v, EMS_TYPE_UBAParameterWWPlus);
write_command(EMS_TYPE_UBAParameterWWPlus, 11, v + 1, EMS_TYPE_UBAParameterWWPlus);
} else {
write_command(EMS_TYPE_UBAParameterWW, 7, v, EMS_TYPE_UBAParameterWW);
write_command(EMS_TYPE_UBAParameterWW, 7, v + 1, EMS_TYPE_UBAParameterWW);
}
return true;

View File

@@ -245,7 +245,7 @@ MAKE_PSTR_ENUM(enum_progMode, FL_(prog1), FL_(prog2))
MAKE_PSTR_ENUM(enum_progMode4, FL_(proga), FL_(progb), FL_(progc), FL_(progd), FL_(proge), FL_(progf))
MAKE_PSTR_ENUM(enum_climate, FL_(seltemp), FL_(roomtemp))
MAKE_PSTR_ENUM(enum_charge, FL_(chargepump), FL_(3wayvalve))
MAKE_PSTR_ENUM(enum_freq, FL_(off), FL_(1x3min), FL_(2x3min), FL_(3x3min), FL_(4x3min), FL_(5x3min), FL_(6x3min), FL_(continuous))
MAKE_PSTR_ENUM(enum_freq, FL_(1x3min), FL_(2x3min), FL_(3x3min), FL_(4x3min), FL_(5x3min), FL_(6x3min), FL_(continuous))
MAKE_PSTR_ENUM(enum_off_time_date_manual, FL_(off), FL_(time), FL_(date), FL_(manual))
MAKE_PSTR_ENUM(enum_comfort, FL_(hot), FL_(eco), FL_(intelligent))
MAKE_PSTR_ENUM(enum_comfort1, FL_(high_comfort), FL_(eco))