mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 00:09:51 +03:00
added support for heatpumps
This commit is contained in:
@@ -9,6 +9,7 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
|
|||||||
|
|
||||||
### Added
|
### Added
|
||||||
|
|
||||||
|
- HeatPump (e.g. Nefit Enviline)
|
||||||
- MM50 Mixer
|
- MM50 Mixer
|
||||||
- tx_mode takes a value from 0 to 3 for the different Tx logic
|
- tx_mode takes a value from 0 to 3 for the different Tx logic
|
||||||
|
|
||||||
|
|||||||
@@ -110,6 +110,11 @@ command_t project_cmds[] = {
|
|||||||
|
|
||||||
{false, "info", "show data captured on the EMS bus"},
|
{false, "info", "show data captured on the EMS bus"},
|
||||||
{false, "log <n | b | t | r | v>", "set logging mode to none, basic, thermostat only, raw or verbose"},
|
{false, "log <n | b | t | r | v>", "set logging mode to none, basic, thermostat only, raw or verbose"},
|
||||||
|
|
||||||
|
#ifdef TESTS
|
||||||
|
{false, "test <n>", "insert a test telegram on to the EMS bus"},
|
||||||
|
#endif
|
||||||
|
|
||||||
{false, "publish", "publish all values to MQTT"},
|
{false, "publish", "publish all values to MQTT"},
|
||||||
{false, "refresh", "fetch values from the EMS devices"},
|
{false, "refresh", "fetch values from the EMS devices"},
|
||||||
{false, "devices", "list all supported and detected EMS devices and types IDs"},
|
{false, "devices", "list all supported and detected EMS devices and types IDs"},
|
||||||
@@ -449,13 +454,21 @@ void showInfo() {
|
|||||||
if (EMS_Other.SM) {
|
if (EMS_Other.SM) {
|
||||||
myDebug_P(PSTR("")); // newline
|
myDebug_P(PSTR("")); // newline
|
||||||
myDebug_P(PSTR("%sSolar Module stats:%s"), COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
myDebug_P(PSTR("%sSolar Module stats:%s"), COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
||||||
_renderShortValue(" Collector temperature", "C", EMS_Other.SMcollectorTemp);
|
_renderShortValue("Collector temperature", "C", EMS_Other.SMcollectorTemp);
|
||||||
_renderShortValue(" Bottom temperature", "C", EMS_Other.SMbottomTemp);
|
_renderShortValue("Bottom temperature", "C", EMS_Other.SMbottomTemp);
|
||||||
_renderIntValue(" Pump modulation", "%", EMS_Other.SMpumpModulation);
|
_renderIntValue("Pump modulation", "%", EMS_Other.SMpumpModulation);
|
||||||
_renderBoolValue(" Pump active", EMS_Other.SMpump);
|
_renderBoolValue("Pump active", EMS_Other.SMpump);
|
||||||
_renderShortValue(" Energy Last Hour", "Wh", EMS_Other.SMEnergyLastHour, 1); // *10
|
_renderShortValue("Energy Last Hour", "Wh", EMS_Other.SMEnergyLastHour, 1); // *10
|
||||||
_renderShortValue(" Energy Today", "Wh", EMS_Other.SMEnergyToday, 0);
|
_renderShortValue("Energy Today", "Wh", EMS_Other.SMEnergyToday, 0);
|
||||||
_renderShortValue(" Energy Total", "kWH", EMS_Other.SMEnergyTotal, 1); // *10
|
_renderShortValue("Energy Total", "kWH", EMS_Other.SMEnergyTotal, 1); // *10
|
||||||
|
}
|
||||||
|
|
||||||
|
// For HeatPumps
|
||||||
|
if (EMS_Other.HP) {
|
||||||
|
myDebug_P(PSTR("")); // newline
|
||||||
|
myDebug_P(PSTR("%sHeat Pump stats:%s"), COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
||||||
|
_renderIntValue("Pump modulation", "%", EMS_Other.HPModulation);
|
||||||
|
_renderIntValue("Pump speed", "%", EMS_Other.HPSpeed);
|
||||||
}
|
}
|
||||||
|
|
||||||
// Thermostat stats
|
// Thermostat stats
|
||||||
@@ -567,6 +580,7 @@ void publishSensorValues() {
|
|||||||
// CRC check is done to see if there are changes in the values since the last send to avoid too much wifi traffic
|
// CRC check is done to see if there are changes in the values since the last send to avoid too much wifi traffic
|
||||||
// a check is done against the previous values and if there are changes only then they are published. Unless force=true
|
// a check is done against the previous values and if there are changes only then they are published. Unless force=true
|
||||||
void publishValues(bool force) {
|
void publishValues(bool force) {
|
||||||
|
|
||||||
// don't send if MQTT is connected
|
// don't send if MQTT is connected
|
||||||
if (!myESP.isMQTTConnected()) {
|
if (!myESP.isMQTTConnected()) {
|
||||||
return;
|
return;
|
||||||
@@ -751,6 +765,7 @@ void publishValues(bool force) {
|
|||||||
}
|
}
|
||||||
|
|
||||||
// handle the other values separately
|
// handle the other values separately
|
||||||
|
|
||||||
// For SM10 and SM100 Solar Modules
|
// For SM10 and SM100 Solar Modules
|
||||||
if (EMS_Other.SM) {
|
if (EMS_Other.SM) {
|
||||||
// build new json object
|
// build new json object
|
||||||
@@ -796,6 +811,27 @@ void publishValues(bool force) {
|
|||||||
myESP.mqttPublish(TOPIC_SM_DATA, data);
|
myESP.mqttPublish(TOPIC_SM_DATA, data);
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
// handle HeatPump
|
||||||
|
if (EMS_Other.HP) {
|
||||||
|
// build new json object
|
||||||
|
doc.clear();
|
||||||
|
JsonObject rootSM = doc.to<JsonObject>();
|
||||||
|
|
||||||
|
if (EMS_Other.HPModulation != EMS_VALUE_INT_NOTSET)
|
||||||
|
rootSM[HP_PUMPMODULATION] = EMS_Other.HPModulation;
|
||||||
|
|
||||||
|
if (EMS_Other.HPSpeed != EMS_VALUE_INT_NOTSET)
|
||||||
|
rootSM[HP_PUMPSPEED] = EMS_Other.HPSpeed;
|
||||||
|
|
||||||
|
data[0] = '\0'; // reset data for next package
|
||||||
|
serializeJson(doc, data, sizeof(data));
|
||||||
|
|
||||||
|
myDebugLog("Publishing HeatPump data via MQTT");
|
||||||
|
|
||||||
|
// send values via MQTT
|
||||||
|
myESP.mqttPublish(TOPIC_HP_DATA, data);
|
||||||
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
// sets the shower timer on/off
|
// sets the shower timer on/off
|
||||||
@@ -977,7 +1013,7 @@ void runUnitTest(uint8_t test_num) {
|
|||||||
publishValuesTimer.detach();
|
publishValuesTimer.detach();
|
||||||
systemCheckTimer.detach();
|
systemCheckTimer.detach();
|
||||||
regularUpdatesTimer.detach();
|
regularUpdatesTimer.detach();
|
||||||
EMSESP_Status.listen_mode = true; // temporary go into listen mode to disable Tx
|
// EMSESP_Status.listen_mode = true; // temporary go into listen mode to disable Tx
|
||||||
ems_testTelegram(test_num);
|
ems_testTelegram(test_num);
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -1092,7 +1128,7 @@ bool SettingsCallback(MYESP_FSACTION action, uint8_t wc, const char * setting, c
|
|||||||
EMSESP_Status.listen_mode = false;
|
EMSESP_Status.listen_mode = false;
|
||||||
ok = true;
|
ok = true;
|
||||||
ems_setTxDisabled(false);
|
ems_setTxDisabled(false);
|
||||||
myDebug_P(PSTR("* out of listen mode. Tx is enabled."));
|
myDebug_P(PSTR("* out of listen mode. Tx is now enabled."));
|
||||||
} else {
|
} else {
|
||||||
myDebug_P(PSTR("Error. Usage: set listen_mode <on | off>"));
|
myDebug_P(PSTR("Error. Usage: set listen_mode <on | off>"));
|
||||||
}
|
}
|
||||||
@@ -1451,7 +1487,6 @@ void MQTTCallback(unsigned int type, const char * topic, const char * message) {
|
|||||||
if ((hc >= 1) && (hc <= 2)) {
|
if ((hc >= 1) && (hc <= 2)) {
|
||||||
EMSESP_Status.heating_circuit = hc;
|
EMSESP_Status.heating_circuit = hc;
|
||||||
ems_setThermostatHC(hc);
|
ems_setThermostatHC(hc);
|
||||||
// TODO: save setting to SPIFFS??
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|||||||
40
src/ems.cpp
40
src/ems.cpp
@@ -50,7 +50,6 @@ void _process_UBAMonitorWWMessage(_EMS_RxTelegram * EMS_RxTelegram);
|
|||||||
void _process_UBAParameterWW(_EMS_RxTelegram * EMS_RxTelegram);
|
void _process_UBAParameterWW(_EMS_RxTelegram * EMS_RxTelegram);
|
||||||
void _process_UBATotalUptimeMessage(_EMS_RxTelegram * EMS_RxTelegram);
|
void _process_UBATotalUptimeMessage(_EMS_RxTelegram * EMS_RxTelegram);
|
||||||
void _process_UBAParametersMessage(_EMS_RxTelegram * EMS_RxTelegram);
|
void _process_UBAParametersMessage(_EMS_RxTelegram * EMS_RxTelegram);
|
||||||
|
|
||||||
void _process_SetPoints(_EMS_RxTelegram * EMS_RxTelegram);
|
void _process_SetPoints(_EMS_RxTelegram * EMS_RxTelegram);
|
||||||
|
|
||||||
// SM10
|
// SM10
|
||||||
@@ -62,6 +61,10 @@ void _process_SM100Status(_EMS_RxTelegram * EMS_RxTelegram);
|
|||||||
void _process_SM100Status2(_EMS_RxTelegram * EMS_RxTelegram);
|
void _process_SM100Status2(_EMS_RxTelegram * EMS_RxTelegram);
|
||||||
void _process_SM100Energy(_EMS_RxTelegram * EMS_RxTelegram);
|
void _process_SM100Energy(_EMS_RxTelegram * EMS_RxTelegram);
|
||||||
|
|
||||||
|
// HeatPump HP
|
||||||
|
void _process_HPMonitor1(_EMS_RxTelegram * EMS_RxTelegram);
|
||||||
|
void _process_HPMonitor2(_EMS_RxTelegram * EMS_RxTelegram);
|
||||||
|
|
||||||
// Common for most thermostats
|
// Common for most thermostats
|
||||||
void _process_RCTime(_EMS_RxTelegram * EMS_RxTelegram);
|
void _process_RCTime(_EMS_RxTelegram * EMS_RxTelegram);
|
||||||
void _process_RCOutdoorTempMessage(_EMS_RxTelegram * EMS_RxTelegram);
|
void _process_RCOutdoorTempMessage(_EMS_RxTelegram * EMS_RxTelegram);
|
||||||
@@ -120,6 +123,8 @@ const _EMS_Type EMS_Types[] = {
|
|||||||
{EMS_MODEL_OTHER, EMS_TYPE_SM100Status, "SM100Status", _process_SM100Status},
|
{EMS_MODEL_OTHER, EMS_TYPE_SM100Status, "SM100Status", _process_SM100Status},
|
||||||
{EMS_MODEL_OTHER, EMS_TYPE_SM100Status2, "SM100Status2", _process_SM100Status2},
|
{EMS_MODEL_OTHER, EMS_TYPE_SM100Status2, "SM100Status2", _process_SM100Status2},
|
||||||
{EMS_MODEL_OTHER, EMS_TYPE_SM100Energy, "SM100Energy", _process_SM100Energy},
|
{EMS_MODEL_OTHER, EMS_TYPE_SM100Energy, "SM100Energy", _process_SM100Energy},
|
||||||
|
{EMS_MODEL_OTHER, EMS_TYPE_HPMonitor1, "HeatPumpMonitor1", _process_HPMonitor1},
|
||||||
|
{EMS_MODEL_OTHER, EMS_TYPE_HPMonitor2, "HeatPumpMonitor2", _process_HPMonitor2},
|
||||||
|
|
||||||
// RC10
|
// RC10
|
||||||
{EMS_MODEL_RC10, EMS_TYPE_RCTime, "RCTime", _process_RCTime},
|
{EMS_MODEL_RC10, EMS_TYPE_RCTime, "RCTime", _process_RCTime},
|
||||||
@@ -299,6 +304,8 @@ void ems_init() {
|
|||||||
EMS_Other.SMEnergyLastHour = EMS_VALUE_SHORT_NOTSET;
|
EMS_Other.SMEnergyLastHour = EMS_VALUE_SHORT_NOTSET;
|
||||||
EMS_Other.SMEnergyToday = EMS_VALUE_SHORT_NOTSET;
|
EMS_Other.SMEnergyToday = EMS_VALUE_SHORT_NOTSET;
|
||||||
EMS_Other.SMEnergyTotal = EMS_VALUE_SHORT_NOTSET;
|
EMS_Other.SMEnergyTotal = EMS_VALUE_SHORT_NOTSET;
|
||||||
|
EMS_Other.HPModulation = EMS_VALUE_INT_NOTSET;
|
||||||
|
EMS_Other.HPSpeed = EMS_VALUE_INT_NOTSET;
|
||||||
|
|
||||||
// calculated values
|
// calculated values
|
||||||
EMS_Boiler.tapwaterActive = EMS_VALUE_INT_NOTSET; // Hot tap water is on/off
|
EMS_Boiler.tapwaterActive = EMS_VALUE_INT_NOTSET; // Hot tap water is on/off
|
||||||
@@ -315,6 +322,7 @@ void ems_init() {
|
|||||||
|
|
||||||
// set other types
|
// set other types
|
||||||
EMS_Other.SM = false;
|
EMS_Other.SM = false;
|
||||||
|
EMS_Other.HP = false;
|
||||||
|
|
||||||
// default logging is none
|
// default logging is none
|
||||||
ems_setLogging(EMS_SYS_LOGGING_DEFAULT);
|
ems_setLogging(EMS_SYS_LOGGING_DEFAULT);
|
||||||
@@ -695,7 +703,6 @@ void _ems_readTelegram(uint8_t * telegram, uint8_t length) {
|
|||||||
// check first for a Poll for us
|
// check first for a Poll for us
|
||||||
// the poll has the MSB set - seems to work on both EMS and Junkers
|
// the poll has the MSB set - seems to work on both EMS and Junkers
|
||||||
if (value == (EMS_ID_ME | 0x80)) {
|
if (value == (EMS_ID_ME | 0x80)) {
|
||||||
|
|
||||||
EMS_Sys_Status.emsTxCapable = true;
|
EMS_Sys_Status.emsTxCapable = true;
|
||||||
uint32_t timenow_microsecs = micros();
|
uint32_t timenow_microsecs = micros();
|
||||||
EMS_Sys_Status.emsPollFrequency = (timenow_microsecs - _last_emsPollFrequency);
|
EMS_Sys_Status.emsPollFrequency = (timenow_microsecs - _last_emsPollFrequency);
|
||||||
@@ -1427,10 +1434,9 @@ void _process_SM100Status2(_EMS_RxTelegram * EMS_RxTelegram) {
|
|||||||
|
|
||||||
/*
|
/*
|
||||||
* SM100Energy - type 0x028E EMS+ for energy readings
|
* SM100Energy - type 0x028E EMS+ for energy readings
|
||||||
|
* e.g. 30 00 FF 00 02 8E 00 00 00 00 00 00 06 C5 00 00 76 35
|
||||||
*/
|
*/
|
||||||
void _process_SM100Energy(_EMS_RxTelegram * EMS_RxTelegram) {
|
void _process_SM100Energy(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||||
// e.g. 30 00 FF 00 02 8E 00 00 00 00 00 00 06 C5 00 00 76 35
|
|
||||||
|
|
||||||
EMS_Other.SMEnergyLastHour = _toShort(2); // last hour / 10 in Wh
|
EMS_Other.SMEnergyLastHour = _toShort(2); // last hour / 10 in Wh
|
||||||
EMS_Other.SMEnergyToday = _toShort(6); // todays in Wh
|
EMS_Other.SMEnergyToday = _toShort(6); // todays in Wh
|
||||||
EMS_Other.SMEnergyTotal = _toShort(10); // total / 10 in kWh
|
EMS_Other.SMEnergyTotal = _toShort(10); // total / 10 in kWh
|
||||||
@@ -1439,6 +1445,26 @@ void _process_SM100Energy(_EMS_RxTelegram * EMS_RxTelegram) {
|
|||||||
EMS_Sys_Status.emsRefreshed = true; // triggers a send the values back via MQTT
|
EMS_Sys_Status.emsRefreshed = true; // triggers a send the values back via MQTT
|
||||||
}
|
}
|
||||||
|
|
||||||
|
/*
|
||||||
|
* Type 0xE3 - HeatPump Monitor 1
|
||||||
|
*/
|
||||||
|
void _process_HPMonitor1(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||||
|
EMS_Other.HPModulation = _toByte(14); // modulation %
|
||||||
|
|
||||||
|
EMS_Other.HP = true;
|
||||||
|
EMS_Sys_Status.emsRefreshed = true; // triggers a send the values back via MQTT
|
||||||
|
}
|
||||||
|
|
||||||
|
/*
|
||||||
|
* Type 0xE5 - HeatPump Monitor 2
|
||||||
|
*/
|
||||||
|
void _process_HPMonitor2(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||||
|
EMS_Other.HPSpeed = _toByte(25); // speed %
|
||||||
|
|
||||||
|
EMS_Other.HP = true;
|
||||||
|
EMS_Sys_Status.emsRefreshed = true; // triggers a send the values back via MQTT
|
||||||
|
}
|
||||||
|
|
||||||
/**
|
/**
|
||||||
* UBASetPoint 0x1A
|
* UBASetPoint 0x1A
|
||||||
*/
|
*/
|
||||||
@@ -1631,6 +1657,12 @@ void _process_Version(_EMS_RxTelegram * EMS_RxTelegram) {
|
|||||||
myDebug_P(PSTR("SM10 Solar Module support enabled."));
|
myDebug_P(PSTR("SM10 Solar Module support enabled."));
|
||||||
}
|
}
|
||||||
|
|
||||||
|
// see if this is a HeatPump
|
||||||
|
if (Other_Types[i].device_id == EMS_ID_HP) {
|
||||||
|
EMS_Other.HP = true; // we have detected a HP
|
||||||
|
myDebug_P(PSTR("HeatPump support enabled."));
|
||||||
|
}
|
||||||
|
|
||||||
// fetch other values
|
// fetch other values
|
||||||
ems_getOtherValues();
|
ems_getOtherValues();
|
||||||
return;
|
return;
|
||||||
|
|||||||
@@ -18,6 +18,7 @@
|
|||||||
#define EMS_ID_ME 0x0B // Fixed - our device, hardcoded as the "Service Key"
|
#define EMS_ID_ME 0x0B // Fixed - our device, hardcoded as the "Service Key"
|
||||||
#define EMS_ID_DEFAULT_BOILER 0x08
|
#define EMS_ID_DEFAULT_BOILER 0x08
|
||||||
#define EMS_ID_SM 0x30 // Solar Module SM10 and SM100
|
#define EMS_ID_SM 0x30 // Solar Module SM10 and SM100
|
||||||
|
#define EMS_ID_HP 0x38 // HeatPump
|
||||||
#define EMS_ID_GATEWAY 0x48 // KM200 Web Gateway
|
#define EMS_ID_GATEWAY 0x48 // KM200 Web Gateway
|
||||||
|
|
||||||
#define EMS_MIN_TELEGRAM_LENGTH 6 // minimal length for a validation telegram, including CRC
|
#define EMS_MIN_TELEGRAM_LENGTH 6 // minimal length for a validation telegram, including CRC
|
||||||
@@ -242,7 +243,8 @@ typedef struct { // UBAParameterWW
|
|||||||
|
|
||||||
// SM Solar Module - SM10Monitor/SM100Monitor
|
// SM Solar Module - SM10Monitor/SM100Monitor
|
||||||
typedef struct {
|
typedef struct {
|
||||||
bool SM; // set true if there is a SM available
|
bool SM; // set true if there is a Solar Module available
|
||||||
|
bool HP; // set true if there is a Heat Pump available
|
||||||
int16_t SMcollectorTemp; // collector temp
|
int16_t SMcollectorTemp; // collector temp
|
||||||
int16_t SMbottomTemp; // bottom temp
|
int16_t SMbottomTemp; // bottom temp
|
||||||
uint8_t SMpumpModulation; // modulation solar pump
|
uint8_t SMpumpModulation; // modulation solar pump
|
||||||
@@ -250,6 +252,8 @@ typedef struct {
|
|||||||
int16_t SMEnergyLastHour;
|
int16_t SMEnergyLastHour;
|
||||||
int16_t SMEnergyToday;
|
int16_t SMEnergyToday;
|
||||||
int16_t SMEnergyTotal;
|
int16_t SMEnergyTotal;
|
||||||
|
uint8_t HPModulation; // heatpump modulation in %
|
||||||
|
uint8_t HPSpeed; // speed 0-100 %
|
||||||
} _EMS_Other;
|
} _EMS_Other;
|
||||||
|
|
||||||
// Thermostat data
|
// Thermostat data
|
||||||
|
|||||||
@@ -46,6 +46,8 @@
|
|||||||
#define EMS_TYPE_SM100Status 0x0264 // SM100Status
|
#define EMS_TYPE_SM100Status 0x0264 // SM100Status
|
||||||
#define EMS_TYPE_SM100Status2 0x026A // SM100Status2
|
#define EMS_TYPE_SM100Status2 0x026A // SM100Status2
|
||||||
#define EMS_TYPE_SM100Energy 0x028E // SM100Energy
|
#define EMS_TYPE_SM100Energy 0x028E // SM100Energy
|
||||||
|
#define EMS_TYPE_HPMonitor1 0xE3 // HeatPump Monitor 1
|
||||||
|
#define EMS_TYPE_HPMonitor2 0xE5 // HeatPump Monitor 2
|
||||||
|
|
||||||
/*
|
/*
|
||||||
* Thermostats...
|
* Thermostats...
|
||||||
|
|||||||
@@ -58,6 +58,11 @@
|
|||||||
#define SM_ENERGYTODAY "energytoday" // energy today
|
#define SM_ENERGYTODAY "energytoday" // energy today
|
||||||
#define SM_ENERGYTOTAL "energytotal" // energy total
|
#define SM_ENERGYTOTAL "energytotal" // energy total
|
||||||
|
|
||||||
|
// MQTT for HP (HeatPump)
|
||||||
|
#define TOPIC_HP_DATA "hp_data" // topic name
|
||||||
|
#define HP_PUMPMODULATION "pumpmodulation" // pump modulation
|
||||||
|
#define HP_PUMPSPEED "pumpspeed" // pump speed
|
||||||
|
|
||||||
// shower time
|
// shower time
|
||||||
#define TOPIC_SHOWERTIME "showertime" // for sending shower time results
|
#define TOPIC_SHOWERTIME "showertime" // for sending shower time results
|
||||||
#define TOPIC_SHOWER_TIMER "shower_timer" // toggle switch for enabling the shower logic
|
#define TOPIC_SHOWER_TIMER "shower_timer" // toggle switch for enabling the shower logic
|
||||||
|
|||||||
@@ -46,7 +46,11 @@ static const char * TEST_DATA[] = {
|
|||||||
"10 48 F7 00 FF 01 A5 DF FF F7 7F 1F", // test 41 - gateway
|
"10 48 F7 00 FF 01 A5 DF FF F7 7F 1F", // test 41 - gateway
|
||||||
"30 00 FF 09 02 64 1E", // test 42 - SM100
|
"30 00 FF 09 02 64 1E", // test 42 - SM100
|
||||||
"08 00 18 00 05 03 30 00 00 00 00 04 40 80 00 02 17 80 00 00 00 FF 30 48 00 CB 00 00 00", // test 43 - sys pressure
|
"08 00 18 00 05 03 30 00 00 00 00 04 40 80 00 02 17 80 00 00 00 FF 30 48 00 CB 00 00 00", // test 43 - sys pressure
|
||||||
"90 00 FF 00 00 6F 03 01 00 BE 00 BF" // test 44 - FR10
|
"90 00 FF 00 00 6F 03 01 00 BE 00 BF", // test 44 - FR10
|
||||||
|
"08 00 E3 00 01 00 01 00 00 00 00 00 00 00 00 00 DF 00 64 55", // test 45 - heatpump Enviline
|
||||||
|
"08 00 E5 00 00 00 20 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0A", // test 46 - heatpump Enviline
|
||||||
|
"38 10 FF 00 03 2B 00 C7 07 C3 01" // test 47 - heatpump Enviline
|
||||||
|
|
||||||
|
|
||||||
};
|
};
|
||||||
|
|
||||||
|
|||||||
@@ -6,5 +6,5 @@
|
|||||||
#pragma once
|
#pragma once
|
||||||
|
|
||||||
#define APP_NAME "EMS-ESP"
|
#define APP_NAME "EMS-ESP"
|
||||||
#define APP_VERSION "1.8.0b5"
|
#define APP_VERSION "1.8.0b6"
|
||||||
#define APP_HOSTNAME "ems-esp"
|
#define APP_HOSTNAME "ems-esp"
|
||||||
|
|||||||
Reference in New Issue