mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-09 09:19:51 +03:00
added new Version type
This commit is contained in:
@@ -187,7 +187,7 @@ The Boiler (ID 0x08) will send out these broadcast telegrams regularly:
|
||||
And a thermostat (ID 0x17 for a RC20) would broadcast these messages regularly:
|
||||
|
||||
| Type | Description |
|
||||
| ---- | ----------- | undefined |undefined |undefined |undefined |undefined |undefined |undefined |undefined |undefined |undefined |
|
||||
| ---- | ----------- | undefined |undefined |undefined |undefined |undefined |undefined |undefined |undefined |undefined |undefined |undefined |undefined |undefined |undefined |
|
||||
| 0x06 | time on thermostat Y,M,H,D,M,S,wd |
|
||||
|
||||
Refer to the code in `ems.cpp` for further explanation on how to parse these message types and also reference the EMS Wiki.
|
||||
@@ -233,14 +233,15 @@ Every telegram sent is echo'd back to Rx.
|
||||
| Thermostat (0x17) | 0xA8 | RC20Temperature | sets temperature and operating modes |
|
||||
| Thermostat (0x17) | 0xA3 | RCOutdoorTempMessage | |
|
||||
| Thermostat (0x17) | 0x91 | RC20StatusMessage | reads set & current room temperatures |
|
||||
| Thermostat (0x17) | 0x02 | Version | reads Version major/minor |
|
||||
|
||||
Note the thermostat types are based on a RC20 model thermostat. If using an RC30/RC35 use types 0x3E and 0x48 to read the values.
|
||||
|
||||
### Customizing
|
||||
|
||||
Most of the changes will be done in `boiler.ino` and `ems.cpp`.
|
||||
* To add new handlers for data types, create a callback function and add to the `EMS_Types` at the top of the file `ems.cpp` and the DEFINES in `ems.h`
|
||||
* To change your thermostat type set `EMS_ID_THERMOSTAT` in `ems.h`. The default is 0x17 for an RC20.
|
||||
* To add new handlers for data types, create a callback function and add to the `EMS_Types` at the top of the file `ems.cpp`
|
||||
* To change your thermostat type set `EMS_ID_THERMOSTAT` in `ems.cpp`. The default is 0x17 for an RC20.
|
||||
* The DEFINES `BOILER_THERMOSTAT_ENABLED`, `BOILER_SHOWER_ENABLED` and `BOILER_SHOWER_TIMER` enabled the thermostat logic, the shower logic and the shower timer alert logic respectively. 1 is on and 0 is off.
|
||||
|
||||
### MQTT
|
||||
|
||||