Merge branch 'dev' into dev

This commit is contained in:
Proddy
2020-10-18 16:06:12 +02:00
committed by GitHub
3 changed files with 16 additions and 11 deletions

View File

@@ -111,7 +111,7 @@ void EMSESPAPIService::emsespAPIService(AsyncWebServerRequest * request) {
if (output.size()) { if (output.size()) {
doc.shrinkToFit(); doc.shrinkToFit();
char buffer[EMSESP_MAX_JSON_SIZE_LARGE]; char buffer[EMSESP_MAX_JSON_SIZE_LARGE];
serializeJson(doc, buffer); serializeJsonPretty(doc, buffer);
request->send(200, "text/plain", buffer); request->send(200, "text/plain", buffer);
} else { } else {
request->send(200, "text/plain", ok ? F("OK") : F("Invalid")); request->send(200, "text/plain", ok ? F("OK") : F("Invalid"));

View File

@@ -319,7 +319,7 @@ bool Boiler::export_values(JsonObject & output) {
// Warm Water charging type // Warm Water charging type
if (Helpers::hasValue(wWChargeType_, EMS_VALUE_BOOL)) { if (Helpers::hasValue(wWChargeType_, EMS_VALUE_BOOL)) {
output["wWChargeType"] = wWChargeType_ ? F("3way_valve") : F("chargepump"); output["wWChargeType"] = wWChargeType_ ? F("3-way valve") : F("charge pump");
} }
// Warm Water circulation pump available bool // Warm Water circulation pump available bool
@@ -708,23 +708,29 @@ void Boiler::show_values(uuid::console::Shell & shell) {
/* /*
* Check if hot tap water or heating is active * Check if hot tap water or heating is active
* If a value has changed, post it immediately to MQTT so we get real time data * If a value has changed, post it immediately to MQTT so we get real time data
* Values will always be posted first time as heatingActive_ and tapwaterActive_ will have values EMS_VALUE_BOOL_NOTSET
*/ */
void Boiler::check_active() { void Boiler::check_active() {
if ((boilerState_ == EMS_VALUE_UINT_NOTSET) || ((boilerState_ & 0x09) != (last_boilerState & 0x09))) { bool b;
uint8_t val;
// check if heating is active, bits 2 and 4 must be set
b = ((boilerState_ & 0x09) == 0x09);
val = b ? EMS_VALUE_BOOL_ON : EMS_VALUE_BOOL_OFF;
if (heatingActive_ != val) {
heatingActive_ = val;
char s[7]; char s[7];
bool b = ((boilerState_ & 0x09) == 0x09);
Mqtt::publish(F("heating_active"), Helpers::render_boolean(s, b)); Mqtt::publish(F("heating_active"), Helpers::render_boolean(s, b));
heatingActive_ = b ? EMS_VALUE_BOOL_ON : EMS_VALUE_BOOL_OFF;
last_boilerState = boilerState_;
} }
if ((boilerState_ == EMS_VALUE_UINT_NOTSET) || ((boilerState_ & 0x0A) != (last_boilerState & 0x0A))) { // check if tap water is active, bits 1 and 4 must be set
b = ((boilerState_ & 0x0A) == 0x0A);
val = b ? EMS_VALUE_BOOL_ON : EMS_VALUE_BOOL_OFF;
if (tapwaterActive_ != val) {
tapwaterActive_ = val;
char s[7]; char s[7];
bool b = ((boilerState_ & 0x0A) == 0x0A);
Mqtt::publish(F("tapwater_active"), Helpers::render_boolean(s, b)); Mqtt::publish(F("tapwater_active"), Helpers::render_boolean(s, b));
tapwaterActive_ = b ? EMS_VALUE_BOOL_ON : EMS_VALUE_BOOL_OFF;
EMSESP::tap_water_active(b); // let EMS-ESP know, used in the Shower class EMSESP::tap_water_active(b); // let EMS-ESP know, used in the Shower class
last_boilerState = boilerState_;
} }
/* /*

View File

@@ -52,7 +52,6 @@ class Boiler : public EMSdevice {
void print_value2(uuid::console::Shell & shell, const char * param, const __FlashStringHelper * name, const __FlashStringHelper * suffix, JsonObject & json); void print_value2(uuid::console::Shell & shell, const char * param, const __FlashStringHelper * name, const __FlashStringHelper * suffix, JsonObject & json);
uint8_t last_boilerState = EMS_VALUE_UINT_NOTSET; // remember last state of heating and warm water on/off
bool changed_ = false; bool changed_ = false;
bool mqtt_ha_config_ = false; // HA MQTT Discovery bool mqtt_ha_config_ = false; // HA MQTT Discovery