From e2fec03a2184de2fe2fed262dc7b003e660cb8f1 Mon Sep 17 00:00:00 2001 From: marcel Date: Sat, 1 Apr 2023 19:15:54 +0200 Subject: [PATCH] Use exhaust temperature from 0xe4, remove from 0xe5 until verified, closes #1147. --- src/devices/boiler.cpp | 8 +------- 1 file changed, 1 insertion(+), 7 deletions(-) diff --git a/src/devices/boiler.cpp b/src/devices/boiler.cpp index 7f9d721a5..2d0cbb4bb 100644 --- a/src/devices/boiler.cpp +++ b/src/devices/boiler.cpp @@ -1098,13 +1098,7 @@ void Boiler::process_UBAMonitorSlowPlus(std::shared_ptr telegram has_bitupdate(telegram, ignWork_, 2, 3); has_bitupdate(telegram, heatingPump_, 2, 5); has_bitupdate(telegram, wwCirc_, 2, 7); - - /* Update exhaust temperature if it is unequal 0 */ - const uint8_t exhaustTempOffset{6}; - uint16_t exhaustTemp{0}; - if (telegram->read_value(exhaustTemp, exhaustTempOffset)) - has_update(telegram, exhaustTemp_, exhaustTempOffset); - + // has_update(telegram, exhaustTemp_, 6); // Disabled until verified as valid location, see #1147. has_update(telegram, burnStarts_, 10, 3); // force to 3 bytes has_update(telegram, burnWorkMin_, 13, 3); // force to 3 bytes has_update(telegram, burn2WorkMin_, 16, 3); // force to 3 bytes