include collector on/off and tank full for ISM1 - Missing values for Junkers ISM1 #422

This commit is contained in:
proddy
2020-07-06 20:46:17 +02:00
parent b49871320b
commit e57bc0731f

View File

@@ -239,13 +239,18 @@ void Solar::process_SM100Energy(std::shared_ptr<const Telegram> telegram) {
void Solar::process_ISM1StatusMessage(std::shared_ptr<const Telegram> telegram) {
telegram->read_value(collectorTemp_, 4); // Collector Temperature
telegram->read_value(bottomTemp_, 6); // Temperature Bottom of Solar Boiler
uint16_t Wh = 0xFFFF;
telegram->read_value(Wh, 2); // Solar Energy produced in last hour only ushort, is not * 10
if (Wh != 0xFFFF) {
energyLastHour_ = Wh * 10; // set to *10
}
telegram->read_bitvalue(pump_, 8, 0); // Solar pump on (1) or off (0)
telegram->read_value(pumpWorkMin_, 10, 3); // force to 3 bytes
telegram->read_bitvalue(collectorOnOff_, 9, 0); // collector on/off
telegram->read_bitvalue(tankHeated_, 9, 2); // tank full
}
/*