supress printing some values if unset
This commit is contained in:
@@ -340,19 +340,25 @@ void Boiler::show_values(uuid::console::Shell & shell) {
|
|||||||
}
|
}
|
||||||
|
|
||||||
print_value(shell, 2, F("Warm Water activated"), wWActivated_, nullptr, EMS_VALUE_BOOL);
|
print_value(shell, 2, F("Warm Water activated"), wWActivated_, nullptr, EMS_VALUE_BOOL);
|
||||||
print_value(shell, 2, F("Warm Water charging type"), wWCircPumpType_ ? F("3-way valve") : F("charge pump"));
|
if (Helpers::hasValue(wWCircPumpType_, true)) {
|
||||||
print_value(shell, 2, F("Warm Water circulation pump available"), wWCircPump_, nullptr, EMS_VALUE_BOOL);
|
print_value(shell, 2, F("Warm Water charging type"), wWCircPumpType_ ? F("3-way valve") : F("charge pump"));
|
||||||
if (wWCircPumpMode_ == 7) {
|
|
||||||
print_value(shell, 2, F("Warm Water circulation pump freq"), F("continuous"));
|
|
||||||
} else {
|
|
||||||
char s[7];
|
|
||||||
char buffer[2];
|
|
||||||
buffer[0] = (wWCircPumpMode_ % 10) + '0';
|
|
||||||
buffer[1] = '\0';
|
|
||||||
strlcpy(s, buffer, 7);
|
|
||||||
strlcat(s, "x3min", 7);
|
|
||||||
print_value(shell, 2, F("Warm Water circulation pump freq"), s);
|
|
||||||
}
|
}
|
||||||
|
print_value(shell, 2, F("Warm Water circulation pump available"), wWCircPump_, nullptr, EMS_VALUE_BOOL);
|
||||||
|
|
||||||
|
if (Helpers::hasValue(wWCircPumpMode_)) {
|
||||||
|
if (wWCircPumpMode_ == 7) {
|
||||||
|
print_value(shell, 2, F("Warm Water circulation pump freq"), F("continuous"));
|
||||||
|
} else {
|
||||||
|
char s[7];
|
||||||
|
char buffer[2];
|
||||||
|
buffer[0] = (wWCircPumpMode_ % 10) + '0';
|
||||||
|
buffer[1] = '\0';
|
||||||
|
strlcpy(s, buffer, 7);
|
||||||
|
strlcat(s, "x3min", 7);
|
||||||
|
print_value(shell, 2, F("Warm Water circulation pump freq"), s);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
print_value(shell, 2, F("Warm Water circulation active"), wWCirc_, nullptr, EMS_VALUE_BOOL);
|
print_value(shell, 2, F("Warm Water circulation active"), wWCirc_, nullptr, EMS_VALUE_BOOL);
|
||||||
|
|
||||||
if (wWComfort_ == 0x00) {
|
if (wWComfort_ == 0x00) {
|
||||||
@@ -697,6 +703,8 @@ void Boiler::set_warmwater_mode(const uint8_t comfort) {
|
|||||||
} else if (comfort == 3) {
|
} else if (comfort == 3) {
|
||||||
LOG_INFO(F("Setting boiler warm water to intelligent"));
|
LOG_INFO(F("Setting boiler warm water to intelligent"));
|
||||||
set = 2;
|
set = 2;
|
||||||
|
} else {
|
||||||
|
return; // do nothing
|
||||||
}
|
}
|
||||||
write_command(EMS_TYPE_UBAParameterWW, 9, comfort);
|
write_command(EMS_TYPE_UBAParameterWW, 9, comfort);
|
||||||
// some boilers do not have this setting, than it's done by thermostat
|
// some boilers do not have this setting, than it's done by thermostat
|
||||||
|
|||||||