mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-09 17:29:50 +03:00
added ESPurna version
This commit is contained in:
359
espurna/boiler-espurna.ino
Normal file
359
espurna/boiler-espurna.ino
Normal file
@@ -0,0 +1,359 @@
|
||||
// Boiler
|
||||
// Espurna version
|
||||
// Paul Derbyshire - https://github.com/proddy/EMS-ESP-Boiler
|
||||
|
||||
#include "emsuart.h"
|
||||
#include <ArduinoJson.h>
|
||||
#include <ems.h>
|
||||
|
||||
#define myDebug(...) debugSend(__VA_ARGS__)
|
||||
|
||||
#define BOILER_THERMOSTAT_ENABLED 1
|
||||
#define BOILER_SHOWER_ENABLED 1
|
||||
#define BOILER_POLLING_ENABLED 0
|
||||
#define BOILER_LOGGING_NONE 1
|
||||
|
||||
typedef struct {
|
||||
bool wifi_connected;
|
||||
bool boiler_online;
|
||||
bool thermostat_enabled;
|
||||
bool shower_enabled; // true if we want to report back on shower times
|
||||
bool shower_timer; // true if we want the cold water reminder
|
||||
} _Boiler_Status;
|
||||
|
||||
typedef struct {
|
||||
bool showerOn;
|
||||
unsigned long timerStart; // ms
|
||||
unsigned long timerPause; // ms
|
||||
unsigned long duration; // ms
|
||||
bool isColdShot; // true if we've just sent a jolt of cold water
|
||||
} _Boiler_Shower;
|
||||
|
||||
// store for overall system status
|
||||
_Boiler_Status Boiler_Status;
|
||||
_Boiler_Shower Boiler_Shower;
|
||||
|
||||
// Config
|
||||
void _boilerConfigure() {
|
||||
Boiler_Status.thermostat_enabled = getSetting("boilerThermostat", BOILER_THERMOSTAT_ENABLED).toInt() == 1;
|
||||
ems_setThermostatEnabled(Boiler_Status.thermostat_enabled);
|
||||
|
||||
bool _boilerPolling = getSetting("boilerPolling", BOILER_POLLING_ENABLED).toInt() == 1;
|
||||
ems_setPoll(_boilerPolling);
|
||||
|
||||
uint8_t _boilerLogging = getSetting("boilerLogging", BOILER_LOGGING_NONE).toInt();
|
||||
ems_setLogging((_EMS_SYS_LOGGING)_boilerLogging);
|
||||
|
||||
Boiler_Status.shower_enabled = getSetting("boilerShower", BOILER_SHOWER_ENABLED).toInt() == 1;
|
||||
}
|
||||
|
||||
// WEB callbacks
|
||||
bool _boilerWebSocketOnReceive(const char * key, JsonVariant & value) {
|
||||
return (strncmp(key, "boiler", 6) == 0);
|
||||
}
|
||||
|
||||
void _boilerWebSocketOnSend(JsonObject & root) {
|
||||
root["boilerThermostat"] = getSetting("boilerThermostat", BOILER_THERMOSTAT_ENABLED).toInt() == 1;
|
||||
root["boilerShower"] = getSetting("boilerShower", BOILER_SHOWER_ENABLED).toInt() == 1;
|
||||
root["boilerPolling"] = getSetting("boilerPolling", BOILER_POLLING_ENABLED).toInt() == 1;
|
||||
root["boilerLogging"] = getSetting("boilerLogging", BOILER_LOGGING_NONE).toInt();
|
||||
}
|
||||
|
||||
// used if we have a button
|
||||
void _boilerWebSocketOnAction(uint32_t client_id, const char * action, JsonObject & data) {
|
||||
}
|
||||
|
||||
// send to HA
|
||||
void sendHA() {
|
||||
String topic = getSetting("haPrefix", HOMEASSISTANT_PREFIX);
|
||||
String output;
|
||||
// assume ha is enabled
|
||||
DynamicJsonBuffer jsonBuffer;
|
||||
JsonObject & config = jsonBuffer.createObject();
|
||||
String name = getSetting("hostname");
|
||||
config.set("name", name);
|
||||
config.set("platform", "mqtt");
|
||||
config.printTo(output);
|
||||
|
||||
mqttSendRaw(topic.c_str(), output.c_str());
|
||||
mqttSend(MQTT_TOPIC_STATUS, MQTT_STATUS_ONLINE, true);
|
||||
}
|
||||
|
||||
// Show command - display stats on an 's' command
|
||||
void showInfo() {
|
||||
char s[10]; // for formatting floats using the _float_to_char() function
|
||||
|
||||
// General stats from EMS bus
|
||||
myDebug("EMS Bus stats:\n");
|
||||
myDebug(" Thermostat is %s, Poll is %s, Shower is %s, Shower timer is %s, RxPgks=%d, TxPkgs=%d, #CrcErrors=%d",
|
||||
((Boiler_Status.thermostat_enabled) ? "enabled" : "disabled"),
|
||||
((EMS_Sys_Status.emsPollEnabled) ? "enabled" : "disabled"),
|
||||
((Boiler_Status.shower_enabled) ? "enabled" : "disabled"),
|
||||
((Boiler_Status.shower_timer) ? "enabled" : "disabled"),
|
||||
EMS_Sys_Status.emsRxPgks,
|
||||
EMS_Sys_Status.emsTxPkgs,
|
||||
EMS_Sys_Status.emxCrcErr);
|
||||
|
||||
myDebug(", RxStatus=");
|
||||
switch (EMS_Sys_Status.emsRxStatus) {
|
||||
case EMS_RX_IDLE:
|
||||
myDebug("idle");
|
||||
break;
|
||||
case EMS_RX_ACTIVE:
|
||||
myDebug("active");
|
||||
break;
|
||||
}
|
||||
|
||||
myDebug(", TxStatus=");
|
||||
switch (EMS_Sys_Status.emsTxStatus) {
|
||||
case EMS_TX_IDLE:
|
||||
myDebug("idle");
|
||||
break;
|
||||
case EMS_TX_PENDING:
|
||||
myDebug("pending");
|
||||
break;
|
||||
case EMS_TX_ACTIVE:
|
||||
myDebug("active");
|
||||
break;
|
||||
}
|
||||
|
||||
myDebug(", TxAction=");
|
||||
switch (EMS_TxTelegram.action) {
|
||||
case EMS_TX_READ:
|
||||
myDebug("read");
|
||||
break;
|
||||
case EMS_TX_WRITE:
|
||||
myDebug("write");
|
||||
break;
|
||||
case EMS_TX_VALIDATE:
|
||||
myDebug("validate");
|
||||
break;
|
||||
case EMS_TX_NONE:
|
||||
myDebug("none");
|
||||
break;
|
||||
}
|
||||
|
||||
myDebug("\nBoiler stats:\n");
|
||||
|
||||
// UBAMonitorWWMessage & UBAParameterWW
|
||||
myDebug(" Warm Water activated: %s\n", (EMS_Boiler.wWActivated ? "yes" : "no"));
|
||||
myDebug(" Warm Water selected temperature: %d C\n", EMS_Boiler.wWSelTemp);
|
||||
myDebug(" Warm Water circulation pump available: %s\n", (EMS_Boiler.wWCircPump ? "yes" : "no"));
|
||||
myDebug(" Warm Water desired temperature: %d C\n", EMS_Boiler.wWDesiredTemp);
|
||||
myDebug(" Warm Water current temperature: %s C\n", _float_to_char(s, EMS_Boiler.wWCurTmp));
|
||||
myDebug(" Warm Water # starts: %d times\n", EMS_Boiler.wWStarts);
|
||||
myDebug(" Warm Water active time: %d days %d hours %d minutes\n",
|
||||
EMS_Boiler.wWWorkM / 1440,
|
||||
(EMS_Boiler.wWWorkM % 1440) / 60,
|
||||
EMS_Boiler.wWWorkM % 60);
|
||||
myDebug(" Warm Water 3-way valve: %s\n", EMS_Boiler.wWHeat ? "on" : "off");
|
||||
|
||||
// UBAMonitorFast
|
||||
myDebug(" Selected flow temperature: %d C\n", EMS_Boiler.selFlowTemp);
|
||||
myDebug(" Current flow temperature: %s C\n", _float_to_char(s, EMS_Boiler.curFlowTemp));
|
||||
myDebug(" Return temperature: %s C\n", _float_to_char(s, EMS_Boiler.retTemp));
|
||||
|
||||
myDebug(" Gas: %s\n", EMS_Boiler.burnGas ? "on" : "off");
|
||||
myDebug(" Boiler pump: %s\n", EMS_Boiler.heatPmp ? "on" : "off");
|
||||
myDebug(" Fan: %s\n", EMS_Boiler.fanWork ? "on" : "off");
|
||||
myDebug(" Ignition: %s\n", EMS_Boiler.ignWork ? "on" : "off");
|
||||
myDebug(" Circulation pump: %s\n", EMS_Boiler.wWCirc ? "on" : "off");
|
||||
myDebug(" Burner max power: %d %%\n", EMS_Boiler.selBurnPow);
|
||||
myDebug(" Burner current power: %d %%\n", EMS_Boiler.curBurnPow);
|
||||
myDebug(" Flame current: %s uA\n", _float_to_char(s, EMS_Boiler.flameCurr));
|
||||
myDebug(" System pressure: %s bar\n", _float_to_char(s, EMS_Boiler.sysPress));
|
||||
|
||||
// UBAMonitorSlow
|
||||
myDebug(" Outside temperature: %s C\n", _float_to_char(s, EMS_Boiler.extTemp));
|
||||
myDebug(" Boiler temperature: %s C\n", _float_to_char(s, EMS_Boiler.boilTemp));
|
||||
myDebug(" Pump modulation: %d %%\n", EMS_Boiler.pumpMod);
|
||||
myDebug(" # burner restarts: %d\n", EMS_Boiler.burnStarts);
|
||||
myDebug(" Total burner operating time: %d days %d hours %d minutes\n",
|
||||
EMS_Boiler.burnWorkMin / 1440,
|
||||
(EMS_Boiler.burnWorkMin % 1440) / 60,
|
||||
EMS_Boiler.burnWorkMin % 60);
|
||||
myDebug(" Total heat operating time: %d days %d hours %d minutes\n",
|
||||
EMS_Boiler.heatWorkMin / 1440,
|
||||
(EMS_Boiler.heatWorkMin % 1440) / 60,
|
||||
EMS_Boiler.heatWorkMin % 60);
|
||||
|
||||
// Thermostat stats
|
||||
if (Boiler_Status.thermostat_enabled) {
|
||||
myDebug("Thermostat stats:\n Thermostat time is %02d:%02d:%02d %d/%d/%d\n",
|
||||
EMS_Thermostat.hour,
|
||||
EMS_Thermostat.minute,
|
||||
EMS_Thermostat.second,
|
||||
EMS_Thermostat.day,
|
||||
EMS_Thermostat.month,
|
||||
EMS_Thermostat.year + 2000);
|
||||
|
||||
myDebug(" Setpoint room temperature is %s C\n", _float_to_char(s, EMS_Thermostat.setpoint_roomTemp));
|
||||
myDebug(" Current room temperature is %s C\n", _float_to_char(s, EMS_Thermostat.curr_roomTemp));
|
||||
myDebug(" Mode is set to ");
|
||||
if (EMS_Thermostat.mode == 0) {
|
||||
myDebug("low\n");
|
||||
} else if (EMS_Thermostat.mode == 1) {
|
||||
myDebug("manual\n");
|
||||
} else if (EMS_Thermostat.mode == 2) {
|
||||
myDebug("clock/auto\n");
|
||||
} else {
|
||||
myDebug("<unknown>\n");
|
||||
}
|
||||
}
|
||||
|
||||
// show the Shower Info
|
||||
if (Boiler_Status.shower_enabled) {
|
||||
myDebug("Shower stats:\n Shower is %s\n", (Boiler_Shower.showerOn ? "on" : "off"));
|
||||
char s[70];
|
||||
uint8_t sec = (uint8_t)((Boiler_Shower.duration / 1000) % 60);
|
||||
uint8_t min = (uint8_t)((Boiler_Shower.duration / (1000 * 60)) % 60);
|
||||
sprintf(s, " Last shower duration was %d minutes and %d %s\n", min, sec, (sec == 1) ? "second" : "seconds");
|
||||
myDebug(s);
|
||||
}
|
||||
|
||||
myDebug("\n");
|
||||
}
|
||||
|
||||
// Init telnet commands
|
||||
void _boilerInitCommands() {
|
||||
settingsRegisterCommand(F("BOILER.INFO"), [](Embedis * e) {
|
||||
showInfo();
|
||||
DEBUG_MSG(_boilerGetConfig().c_str());
|
||||
DEBUG_MSG_P(PSTR("+OK\n"));
|
||||
});
|
||||
|
||||
settingsRegisterCommand(F("BOILER.POLLING"), [](Embedis * e) {
|
||||
if (e->argc < 2) {
|
||||
DEBUG_MSG_P(PSTR("-ERROR: arg is 0 or 1\n"));
|
||||
return;
|
||||
}
|
||||
|
||||
int param = String(e->argv[1]).toInt();
|
||||
|
||||
bool b = setSetting("boilerPolling", param);
|
||||
if (b) {
|
||||
_boilerConfigure();
|
||||
}
|
||||
|
||||
wsSend(_boilerWebSocketOnSend); // update web
|
||||
|
||||
DEBUG_MSG_P(PSTR("+OK\n"));
|
||||
});
|
||||
|
||||
settingsRegisterCommand(F("BOILER.LOGGING"), [](Embedis * e) {
|
||||
if (e->argc < 2) {
|
||||
DEBUG_MSG_P(PSTR("-ERROR: arg is 0 or 1\n"));
|
||||
return;
|
||||
}
|
||||
|
||||
int param = String(e->argv[1]).toInt();
|
||||
|
||||
bool b = setSetting("boilerLogging", param);
|
||||
if (b) {
|
||||
_boilerConfigure();
|
||||
}
|
||||
|
||||
wsSend(_boilerWebSocketOnSend); // update web
|
||||
|
||||
DEBUG_MSG_P(PSTR("+OK\n"));
|
||||
});
|
||||
|
||||
settingsRegisterCommand(F("BOILER.SEND"), [](Embedis * e) {
|
||||
if (e->argc < 2) {
|
||||
DEBUG_MSG_P(PSTR("-ERROR: Wrong arguments\n"));
|
||||
return;
|
||||
}
|
||||
int cmd = String(e->argv[1]).toInt();
|
||||
DEBUG_MSG_P(PSTR("Sending %d\n"), cmd);
|
||||
DEBUG_MSG_P(PSTR("+OK\n"));
|
||||
});
|
||||
}
|
||||
|
||||
void _boilerMQTTCallback(unsigned int type, const char * topic, const char * payload) {
|
||||
/*
|
||||
|
||||
if (type == MQTT_CONNECT_EVENT) {
|
||||
char buffer[strlen(MQTT_TOPIC_LED) + 3];
|
||||
snprintf_P(buffer, sizeof(buffer), PSTR("%s/+"), MQTT_TOPIC_LED);
|
||||
mqttSubscribe(buffer);
|
||||
}
|
||||
|
||||
if (type == MQTT_MESSAGE_EVENT) {
|
||||
|
||||
// Match topic
|
||||
String t = mqttMagnitude((char *) topic);
|
||||
if (!t.startsWith(MQTT_TOPIC_LED)) return;
|
||||
|
||||
// Get led ID
|
||||
unsigned int ledID = t.substring(strlen(MQTT_TOPIC_LED)+1).toInt();
|
||||
if (ledID >= _ledCount()) {
|
||||
DEBUG_MSG_P(PSTR("[LED] Wrong ledID (%d)\n"), ledID);
|
||||
return;
|
||||
}
|
||||
|
||||
// Check if LED is managed
|
||||
if (_ledMode(ledID) != LED_MODE_MQTT) return;
|
||||
|
||||
// get value
|
||||
unsigned char value = relayParsePayload(payload);
|
||||
|
||||
// Action to perform
|
||||
if (value == 2) {
|
||||
_ledToggle(ledID);
|
||||
} else {
|
||||
_ledStatus(ledID, value == 1);
|
||||
}
|
||||
|
||||
}
|
||||
*/
|
||||
}
|
||||
|
||||
// TELNET commands
|
||||
String _boilerGetConfig() {
|
||||
String output;
|
||||
|
||||
// get values and print them
|
||||
output = String("Thermostat is ") + getSetting("boilerThermostat") + String(", Polling is ")
|
||||
+ getSetting("boilerPolling") + String(", Logging is ") + getSetting("boilerLogging")
|
||||
+ String(", Shower is ") + getSetting("boilerShower") + String("\n");
|
||||
|
||||
return output;
|
||||
}
|
||||
|
||||
// SETUP
|
||||
void extraSetup() {
|
||||
boilerSetup();
|
||||
}
|
||||
|
||||
void boilerSetup() {
|
||||
// configure
|
||||
_boilerConfigure();
|
||||
|
||||
wsOnSendRegister(_boilerWebSocketOnSend);
|
||||
wsOnAfterParseRegister(_boilerConfigure);
|
||||
wsOnActionRegister(_boilerWebSocketOnAction);
|
||||
wsOnReceiveRegister(_boilerWebSocketOnReceive);
|
||||
|
||||
mqttRegister(_boilerMQTTCallback);
|
||||
|
||||
_boilerInitCommands();
|
||||
|
||||
// init shower
|
||||
Boiler_Shower.timerStart = 0;
|
||||
Boiler_Shower.timerPause = 0;
|
||||
Boiler_Shower.duration = 0;
|
||||
Boiler_Shower.isColdShot = false;
|
||||
|
||||
// ems init values
|
||||
ems_init();
|
||||
|
||||
// start uart
|
||||
emsuart_init();
|
||||
|
||||
// Register loop
|
||||
espurnaRegisterLoop(_boilerLoop);
|
||||
}
|
||||
|
||||
// LOOP
|
||||
void _boilerLoop() {
|
||||
}
|
||||
28
espurna/custom.h
Normal file
28
espurna/custom.h
Normal file
@@ -0,0 +1,28 @@
|
||||
// export PLATFORMIO_BUILD_FLAGS="'-DUSE_CUSTOM_H'"
|
||||
// e.g.
|
||||
// build_flags = -g -DMQTT_MAX_PACKET_SIZE=400 ${env.ESPURNA_FLAGS} -DPIO_FRAMEWORK_ARDUINO_LWIP_HIGHER_BANDWIDTH -DUSE_CUSTOM_H -DUSE_EXTRA
|
||||
|
||||
#undef EMBEDDED_WEB
|
||||
#define EMBEDDED_WEB 1
|
||||
|
||||
#undef NTP_SERVER
|
||||
#define NTP_SERVER "nl.pool.ntp.org"
|
||||
|
||||
//#undef MQTT_TOPIC
|
||||
//#define MQTT_TOPIC "/{identifier}"
|
||||
// default is "{hostname}"
|
||||
|
||||
#undef ENABLE_DOMOTICZ
|
||||
#define ENABLE_DOMOTICZ 0
|
||||
|
||||
#undef THINGSPEAK_SUPPORT
|
||||
#define THINGSPEAK_SUPPORT 0
|
||||
|
||||
#undef SCHEDULER_SUPPORT
|
||||
#define SCHEDULER_SUPPORT 0
|
||||
|
||||
#undef ENABLE_FAUXMO
|
||||
#define ENABLE_FAUXMO 0
|
||||
|
||||
#undef DEBUG_SERIAL_SUPPORT
|
||||
#define DEBUG_SERIAL_SUPPORT 0
|
||||
1831
espurna/index.html
Normal file
1831
espurna/index.html
Normal file
File diff suppressed because it is too large
Load Diff
Reference in New Issue
Block a user