mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-08 08:49:52 +03:00
version 1.4.1
This commit is contained in:
@@ -10,15 +10,6 @@
|
||||
|
||||
#include "ems.h"
|
||||
|
||||
// Set your wifi and mqtt params
|
||||
// If set to NULL (default) you'll need to set them in AP mode using the 'set' command
|
||||
// as these values are stored in SPIFFs for persisted
|
||||
#define WIFI_SSID NULL
|
||||
#define WIFI_PASSWORD NULL
|
||||
#define MQTT_HOST NULL
|
||||
#define MQTT_USER NULL
|
||||
#define MQTT_PASS NULL
|
||||
|
||||
// All MQTT topics are prefixed with the following string
|
||||
#define MQTT_BASE "home"
|
||||
#define MQTT_TOPIC_START "start"
|
||||
@@ -29,21 +20,53 @@
|
||||
#define MQTT_KEEPALIVE 300
|
||||
#define MQTT_QOS 1
|
||||
|
||||
// thermostat
|
||||
#define TOPIC_THERMOSTAT_DATA "thermostat_data" // for sending thermostat values
|
||||
#define TOPIC_THERMOSTAT_CMD_TEMP "thermostat_cmd_temp" // for received thermostat temp changes
|
||||
#define TOPIC_THERMOSTAT_CMD_MODE "thermostat_cmd_mode" // for received thermostat mode changes
|
||||
#define THERMOSTAT_CURRTEMP "thermostat_currtemp" // current temperature
|
||||
#define THERMOSTAT_SELTEMP "thermostat_seltemp" // selected temperature
|
||||
#define THERMOSTAT_MODE "thermostat_mode" // mode
|
||||
|
||||
// boiler
|
||||
#define TOPIC_BOILER_DATA "boiler_data" // for sending boiler values
|
||||
#define TOPIC_BOILER_TAPWATER_ACTIVE "tapwater_active" // if hot tap water is running
|
||||
#define TOPIC_BOILER_HEATING_ACTIVE "heating_active" // if heating is on
|
||||
|
||||
// shower time
|
||||
#define TOPIC_SHOWERTIME "showertime" // for sending shower time results
|
||||
#define TOPIC_SHOWER_TIMER "shower_timer" // toggle switch for enabling the shower logic
|
||||
#define TOPIC_SHOWER_ALERT "shower_alert" // toggle switch for enabling the shower alarm logic
|
||||
#define TOPIC_SHOWER_COLDSHOT "shower_coldshot" // used to trigger a coldshot from an MQTT command
|
||||
|
||||
// default values for shower logic on/off
|
||||
#define BOILER_SHOWER_TIMER 1 // enable (1) to monitor shower time
|
||||
#define BOILER_SHOWER_ALERT 0 // enable (1) to send alert of cold water when shower time limit has exceeded
|
||||
#define SHOWER_MAX_DURATION 420000 // in ms. 7 minutes, before trigger a shot of cold water
|
||||
|
||||
//////////////////////////////////////////////////////////////////////////////////////////////////
|
||||
// THESE DEFAULT VALUES CAN ALSO BE SET AND STORED WITHTIN THE APPLICATION (see 'set' command) //
|
||||
//////////////////////////////////////////////////////////////////////////////////////////////////
|
||||
|
||||
// Set your wifi and mqtt params
|
||||
// If set to NULL (default) you'll need to set them in AP mode using the 'set' command
|
||||
#define WIFI_SSID NULL
|
||||
#define WIFI_PASSWORD NULL
|
||||
#define MQTT_HOST NULL
|
||||
#define MQTT_USER NULL
|
||||
#define MQTT_PASS NULL
|
||||
|
||||
// Set LED pin used for showing ems bus connection status. Solid is connected, Flashing is error
|
||||
// can be either the onboard LED on the ESP8266 or external via an external pull-up LED (e.g. D1 on bbqkees' board)
|
||||
// can be either the onboard LED on the ESP8266 (LED_BULLETIN) or external via an external pull-up LED (e.g. D1 on bbqkees' board)
|
||||
// can be enabled and disabled via the 'set led' command
|
||||
#define BOILER_LED LED_BUILTIN // LED_BULLETIN for onboard LED
|
||||
// pin can be set by 'set led_gpio'
|
||||
#define EMSESP_LED_GPIO LED_BUILTIN
|
||||
|
||||
// set this if using an external temperature sensor like a DS18B20
|
||||
// D5 is the default on bbqkees' board
|
||||
#define TEMPERATURE_SENSOR_PIN D5
|
||||
#define EMSESP_DALLAS_GPIO D5
|
||||
|
||||
// By default the EMS bus will be scanned for known devices based on product ids in ems_devices.h
|
||||
// You can override the Thermostat model by hardcoding the model type
|
||||
#define MY_THERMOSTAT_MODELID EMS_MODEL_NONE
|
||||
//#define MY_THERMOSTAT_MODELID EMS_MODEL_RC35
|
||||
// You can override the Thermostat and Boiler types here
|
||||
#define EMSESP_BOILER_TYPE EMS_ID_NONE
|
||||
#define EMSESP_THERMOSTAT_TYPE EMS_ID_NONE
|
||||
|
||||
Reference in New Issue