mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 16:29:51 +03:00
product_id 200 as thermostat RC100H, #590
This commit is contained in:
974
interface/package-lock.json
generated
974
interface/package-lock.json
generated
File diff suppressed because it is too large
Load Diff
@@ -4,14 +4,14 @@
|
||||
"private": true,
|
||||
"proxy": "http://localhost:3080",
|
||||
"dependencies": {
|
||||
"@emotion/react": "^11.9.3",
|
||||
"@emotion/styled": "^11.9.3",
|
||||
"@emotion/react": "^11.10.0",
|
||||
"@emotion/styled": "^11.10.0",
|
||||
"@msgpack/msgpack": "^2.7.2",
|
||||
"@mui/icons-material": "^5.8.4",
|
||||
"@mui/material": "^5.9.2",
|
||||
"@mui/material": "^5.9.3",
|
||||
"@table-library/react-table-library": "4.0.10",
|
||||
"@types/lodash": "^4.14.182",
|
||||
"@types/node": "^18.6.2",
|
||||
"@types/node": "^18.6.3",
|
||||
"@types/react": "^18.0.15",
|
||||
"@types/react-dom": "^18.0.6",
|
||||
"@types/react-router-dom": "^5.3.3",
|
||||
|
||||
@@ -112,6 +112,9 @@
|
||||
{191, DeviceType::THERMOSTAT, F("FR120"), DeviceFlags::EMS_DEVICE_FLAG_JUNKERS | DeviceFlags::EMS_DEVICE_FLAG_JUNKERS_OLD}, // older model
|
||||
{192, DeviceType::THERMOSTAT, F("FW120"), DeviceFlags::EMS_DEVICE_FLAG_JUNKERS},
|
||||
|
||||
// Thermostat remote - 0x38
|
||||
{200, DeviceType::THERMOSTAT, F("RC100H"), DeviceFlags::EMS_DEVICE_FLAG_RC100H},
|
||||
|
||||
// Solar Modules - 0x30 (for solar), 0x2A, 0x41 (for ww)
|
||||
{ 73, DeviceType::SOLAR, F("SM10"), DeviceFlags::EMS_DEVICE_FLAG_SM10},
|
||||
{101, DeviceType::SOLAR, F("ISM1"), DeviceFlags::EMS_DEVICE_FLAG_ISM},
|
||||
@@ -129,11 +132,12 @@
|
||||
{161, DeviceType::MIXER, F("MM200"), DeviceFlags::EMS_DEVICE_FLAG_MMPLUS},
|
||||
{204, DeviceType::MIXER, F("MP100"), DeviceFlags::EMS_DEVICE_FLAG_MP}, // pool
|
||||
|
||||
// Heat Pumps - 0x38
|
||||
{200, DeviceType::HEATPUMP, F("HP Module"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{248, DeviceType::HEATPUMP, F("Hybrid Manager HM200"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
// Heat Pumps - 0x38?
|
||||
{252, DeviceType::HEATPUMP, F("HP Module"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
|
||||
// Heat Pumps - 0x53
|
||||
{248, DeviceType::HEATPUMP, F("Hybrid Manager HM200"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
|
||||
// Connect devices - 0x02
|
||||
{171, DeviceType::CONNECT, F("OpenTherm Converter"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{205, DeviceType::CONNECT, F("Moduline Easy Connect"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
|
||||
@@ -28,6 +28,12 @@ Thermostat::Thermostat(uint8_t device_type, uint8_t device_id, uint8_t product_i
|
||||
: EMSdevice(device_type, device_id, product_id, version, name, flags, brand) {
|
||||
uint8_t model = this->model();
|
||||
|
||||
// remote thermostats with humidity
|
||||
if (device_id >= 0x38 && device_id <= 0x3F) { // RC100H remote
|
||||
register_telegram_type(0x042B, F("RemoteTemp"), true, MAKE_PF_CB(process_RemoteTemp));
|
||||
register_telegram_type(0x047B, F("RemoteHumidity"), true, MAKE_PF_CB(process_RemoteHumidity));
|
||||
return; // no values to add
|
||||
}
|
||||
// common telegram handlers
|
||||
register_telegram_type(EMS_TYPE_RCOutdoorTemp, F("RCOutdoorTemp"), false, MAKE_PF_CB(process_RCOutdoorTemp));
|
||||
register_telegram_type(EMS_TYPE_RCTime, F("RCTime"), false, MAKE_PF_CB(process_RCTime));
|
||||
@@ -288,11 +294,17 @@ std::shared_ptr<Thermostat::HeatingCircuit> Thermostat::heating_circuit(std::sha
|
||||
}
|
||||
|
||||
// not found, search device-id types for remote thermostats
|
||||
if (telegram->src >= 0x18 && telegram->src <= 0x1B) {
|
||||
if (telegram->src >= 0x18 && telegram->src <= 0x1F) {
|
||||
hc_num = telegram->src - 0x17;
|
||||
toggle_ = true;
|
||||
}
|
||||
|
||||
// not found, search device-id types for remote thermostats
|
||||
if (telegram->src >= 0x38 && telegram->src <= 0x3F) {
|
||||
hc_num = telegram->src - 0x37;
|
||||
toggle_ = true;
|
||||
}
|
||||
|
||||
// not found, search device-id types for remote thermostats
|
||||
if (telegram->dest >= 0x20 && telegram->dest <= 0x27) {
|
||||
hc_num = telegram->dest - 0x20;
|
||||
@@ -681,6 +693,27 @@ void Thermostat::process_RC20Remote(std::shared_ptr<const Telegram> telegram) {
|
||||
}
|
||||
has_update(telegram, hc->remotetemp, 0);
|
||||
}
|
||||
// 0x42B - for reading the roomtemperature from the RC20/ES72 thermostat (0x38, 0x39, ..)
|
||||
// e.g. "38 10 FF 00 03 2B 00 D1 08 2A 01"
|
||||
void Thermostat::process_RemoteTemp(std::shared_ptr<const Telegram> telegram) {
|
||||
std::shared_ptr<Thermostat::HeatingCircuit> hc = heating_circuit(telegram);
|
||||
if (hc == nullptr) {
|
||||
return;
|
||||
}
|
||||
has_update(telegram, hc->remotetemp, 0);
|
||||
|
||||
}
|
||||
|
||||
// 0x47B - for reading the roomtemperature from the RC20/ES72 thermostat (0x38, 0x39, ..)
|
||||
// e.g. "38 10 FF 00 03 7B 08 24 00 4B"
|
||||
void Thermostat::process_RemoteHumidity(std::shared_ptr<const Telegram> telegram) {
|
||||
std::shared_ptr<Thermostat::HeatingCircuit> hc = heating_circuit(telegram);
|
||||
if (hc == nullptr) {
|
||||
return;
|
||||
}
|
||||
has_update(telegram, hc->dewtemperature, 0);
|
||||
has_update(telegram, hc->humidity, 1);
|
||||
}
|
||||
|
||||
// type 0x0165, ff
|
||||
void Thermostat::process_JunkersSet(std::shared_ptr<const Telegram> telegram) {
|
||||
@@ -3926,6 +3959,14 @@ void Thermostat::register_device_values_hc(std::shared_ptr<Thermostat::HeatingCi
|
||||
// heating circuit
|
||||
uint8_t tag = DeviceValueTAG::TAG_HC1 + hc->hc();
|
||||
|
||||
// RC300 remote with humidity
|
||||
if (device_id() >= 0x38 && device_id() <= 0x3F) {
|
||||
register_device_value(tag, &hc->remotetemp, DeviceValueType::SHORT, FL_(div10), FL_(remotetemp), DeviceValueUOM::DEGREES);
|
||||
register_device_value(tag, &hc->dewtemperature, DeviceValueType::INT, nullptr, FL_(dewTemperature), DeviceValueUOM::DEGREES);
|
||||
register_device_value(tag, &hc->humidity, DeviceValueType::INT, nullptr, FL_(airHumidity), DeviceValueUOM::PERCENT);
|
||||
return;
|
||||
}
|
||||
|
||||
// different logic on how temperature values are stored, depending on model
|
||||
const __FlashStringHelper * const * seltemp_divider;
|
||||
const __FlashStringHelper * const * roomtemp_divider;
|
||||
|
||||
@@ -83,6 +83,8 @@ class Thermostat : public EMSdevice {
|
||||
uint8_t climate;
|
||||
uint8_t switchonoptimization;
|
||||
uint8_t statusbyte; // from RC300monitor
|
||||
int8_t humidity;
|
||||
int8_t dewtemperature;
|
||||
|
||||
// RC 10
|
||||
uint8_t reducehours; // night reduce duration
|
||||
@@ -380,6 +382,8 @@ class Thermostat : public EMSdevice {
|
||||
void process_JunkersRemoteMonitor(std::shared_ptr<const Telegram> telegram);
|
||||
void process_JunkersHybridSettings(std::shared_ptr<const Telegram> telegram);
|
||||
void process_JunkersSetMixer(std::shared_ptr<const Telegram> telegram);
|
||||
void process_RemoteTemp(std::shared_ptr<const Telegram> telegram);
|
||||
void process_RemoteHumidity(std::shared_ptr<const Telegram> telegram);
|
||||
|
||||
// internal helper functions
|
||||
bool set_mode_n(const uint8_t mode, const uint8_t hc_num);
|
||||
|
||||
@@ -355,6 +355,7 @@ class EMSdevice {
|
||||
static constexpr uint8_t EMS_DEVICE_FLAG_RC100 = 10;
|
||||
static constexpr uint8_t EMS_DEVICE_FLAG_JUNKERS = 11;
|
||||
static constexpr uint8_t EMS_DEVICE_FLAG_CRF = 12; // CRF200 only monitor
|
||||
static constexpr uint8_t EMS_DEVICE_FLAG_RC100H = 13; // with humidity
|
||||
|
||||
uint8_t count_entities();
|
||||
bool has_entities() const;
|
||||
|
||||
@@ -931,6 +931,9 @@ bool EMSESP::add_device(const uint8_t device_id, const uint8_t product_id, const
|
||||
// first check to see if we already have it, if so update the record
|
||||
for (const auto & emsdevice : emsdevices) {
|
||||
if (emsdevice && emsdevice->is_device_id(device_id)) {
|
||||
if (product_id == 0) { // update only with valid product_id
|
||||
return true;
|
||||
}
|
||||
LOG_DEBUG(F("Updating details for already active deviceID 0x%02X"), device_id);
|
||||
emsdevice->product_id(product_id);
|
||||
emsdevice->version(version);
|
||||
|
||||
Reference in New Issue