@@ -1013,13 +1013,33 @@ void ems_setWarmWaterOnetime(bool activated) {
|
||||
EMS_TxTelegram.timestamp = millis(); // set timestamp
|
||||
EMS_Sys_Status.txRetryCount = 0; // reset retry counter
|
||||
|
||||
EMS_TxTelegram.action = EMS_TX_TELEGRAM_WRITE;
|
||||
EMS_TxTelegram.dest = EMS_Boiler.device_id;
|
||||
EMS_TxTelegram.type = EMS_TYPE_UBAFlags;
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_UBAParameterWW_wwOneTime;
|
||||
EMS_TxTelegram.length = EMS_MIN_TELEGRAM_LENGTH;
|
||||
EMS_TxTelegram.type_validate = EMS_ID_NONE; // don't validate
|
||||
EMS_TxTelegram.dataValue = (activated ? 0x22 : 0x02); // 0x22 is on, 0x02 is off for RC20RF
|
||||
|
||||
EMS_TxQueue.push(EMS_TxTelegram);
|
||||
}
|
||||
/**
|
||||
* Activate / De-activate circulation of warm water 0x35
|
||||
* true = on, false = off
|
||||
*/
|
||||
void ems_setWarmWaterCirculation(bool activated) {
|
||||
myDebug_P(PSTR("Setting boiler warm water circulation %s"), activated ? "on" : "off");
|
||||
|
||||
_EMS_TxTelegram EMS_TxTelegram = EMS_TX_TELEGRAM_NEW; // create new Tx
|
||||
EMS_TxTelegram.timestamp = millis(); // set timestamp
|
||||
EMS_Sys_Status.txRetryCount = 0; // reset retry counter
|
||||
|
||||
EMS_TxTelegram.action = EMS_TX_TELEGRAM_WRITE;
|
||||
EMS_TxTelegram.dest = EMS_Boiler.device_id;
|
||||
EMS_TxTelegram.type = EMS_TYPE_UBAFlags;
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_UBAParameterWW_wwOneTime;
|
||||
EMS_TxTelegram.length = EMS_MIN_TELEGRAM_LENGTH+1;
|
||||
EMS_TxTelegram.type_validate = EMS_ID_NONE; // don't validate
|
||||
// EMS_TxTelegram.dataValue = (activated ? 0x22 : 0x02); // 0x22 is on, 0x02 is off for RC20RF
|
||||
EMS_TxTelegram.data[4] = 0x11;
|
||||
EMS_TxTelegram.data[5] = (activated ? 0x33 : 0x11);
|
||||
|
||||
|
||||