@@ -36,61 +36,56 @@ class Solar : public EMSdevice {
|
||||
public:
|
||||
Solar(uint8_t device_type, uint8_t device_id, uint8_t product_id, const std::string & version, const std::string & name, uint8_t flags, uint8_t brand);
|
||||
|
||||
virtual void publish_values(JsonObject & json, bool force);
|
||||
virtual bool export_values(JsonObject & json);
|
||||
virtual void device_info_web(JsonArray & root);
|
||||
virtual bool updated_values();
|
||||
virtual bool publish_ha_config();
|
||||
|
||||
private:
|
||||
static uuid::log::Logger logger_;
|
||||
void register_mqtt_ha_config();
|
||||
|
||||
int16_t collectorTemp_ = EMS_VALUE_SHORT_NOTSET; // TS1: Temperature sensor for collector array 1
|
||||
int16_t tankBottomTemp_ = EMS_VALUE_SHORT_NOTSET; // TS2: Temperature sensor 1 cylinder, bottom (solar thermal system)
|
||||
int16_t tankBottomTemp2_ = EMS_VALUE_SHORT_NOTSET; // TS5: Temperature sensor 2 cylinder, bottom, or swimming pool (solar thermal system)
|
||||
int16_t heatExchangerTemp_ = EMS_VALUE_SHORT_NOTSET; // TS6: Heat exchanger temperature sensor
|
||||
uint8_t solarPumpModulation_ = EMS_VALUE_UINT_NOTSET; // PS1: modulation solar pump
|
||||
uint8_t cylinderPumpModulation_ = EMS_VALUE_UINT_NOTSET; // PS5: modulation cylinder pump
|
||||
uint8_t solarPump_ = EMS_VALUE_BOOL_NOTSET; // PS1: solar pump active
|
||||
uint8_t valveStatus_ = EMS_VALUE_BOOL_NOTSET; // VS2: status 3-way valve for cylinder 2 (solar thermal system) with valve
|
||||
int16_t setpoint_maxBottomTemp_ = EMS_VALUE_SHORT_NOTSET; // setpoint for maximum collector temp
|
||||
uint32_t energyLastHour_ = EMS_VALUE_ULONG_NOTSET;
|
||||
uint32_t energyToday_ = EMS_VALUE_ULONG_NOTSET;
|
||||
uint32_t energyTotal_ = EMS_VALUE_ULONG_NOTSET;
|
||||
uint32_t pumpWorkMin_ = EMS_VALUE_ULONG_NOTSET; // Total solar pump operating time
|
||||
uint8_t tankHeated_ = EMS_VALUE_BOOL_NOTSET;
|
||||
uint8_t collectorShutdown_ = EMS_VALUE_BOOL_NOTSET; // Collector shutdown on/off
|
||||
int16_t collectorTemp_; // TS1: Temperature sensor for collector array 1
|
||||
int16_t tankBottomTemp_; // TS2: Temperature sensor 1 cylinder, bottom (solar thermal system)
|
||||
int16_t tankBottomTemp2_; // TS5: Temperature sensor 2 cylinder, bottom, or swimming pool (solar thermal system)
|
||||
int16_t heatExchangerTemp_; // TS6: Heat exchanger temperature sensor
|
||||
uint8_t solarPumpModulation_; // PS1: modulation solar pump
|
||||
uint8_t cylinderPumpModulation_; // PS5: modulation cylinder pump
|
||||
uint8_t solarPump_; // PS1: solar pump active
|
||||
uint8_t valveStatus_; // VS2: status 3-way valve for cylinder 2 (solar thermal system) with valve
|
||||
int16_t setpoint_maxBottomTemp_; // setpoint for maximum collector temp
|
||||
uint32_t energyLastHour_;
|
||||
uint32_t energyToday_;
|
||||
uint32_t energyTotal_;
|
||||
uint32_t pumpWorkMin_; // Total solar pump operating time
|
||||
uint8_t tankHeated_;
|
||||
uint8_t collectorShutdown_; // Collector shutdown on/off
|
||||
|
||||
uint8_t availabilityFlag_ = EMS_VALUE_BOOL_NOTSET;
|
||||
uint8_t configFlag_ = EMS_VALUE_BOOL_NOTSET;
|
||||
uint8_t userFlag_ = EMS_VALUE_BOOL_NOTSET;
|
||||
uint8_t availabilityFlag_;
|
||||
uint8_t configFlag_;
|
||||
uint8_t userFlag_;
|
||||
|
||||
// telegram 0x0358
|
||||
uint8_t heatTransferSystem_ = EMS_VALUE_UINT_NOTSET; // Umladesystem, 00=no
|
||||
uint8_t externalTank_ = EMS_VALUE_UINT_NOTSET; // Heat exchanger, 00=no
|
||||
uint8_t thermalDisinfect_ = EMS_VALUE_UINT_NOTSET; // Daily heatup for disinfection, 00=no
|
||||
uint8_t heatMetering_ = EMS_VALUE_UINT_NOTSET; // Wärmemengenzählung, 00=no
|
||||
uint8_t solarIsEnabled_ = EMS_VALUE_UINT_NOTSET; // System enable, 00=no
|
||||
uint8_t heatTransferSystem_; // Umladesystem, 00=no
|
||||
uint8_t externalTank_; // Heat exchanger, 00=no
|
||||
uint8_t thermalDisinfect_; // Daily heatup for disinfection, 00=no
|
||||
uint8_t heatMetering_; // Wärmemengenzählung, 00=no
|
||||
uint8_t solarIsEnabled_; // System enable, 00=no
|
||||
|
||||
// telegram 0x035A
|
||||
uint8_t collectorTempMax_ = EMS_VALUE_UINT_NOTSET; // maximum allowable temperature for collector
|
||||
uint8_t tank1MaxTempCurrent_ = EMS_VALUE_UINT_NOTSET; // Current value for max tank temp
|
||||
uint8_t collectorTempMin_ = EMS_VALUE_UINT_NOTSET; // minimum allowable temperature for collector
|
||||
uint8_t solarPumpMode_ = EMS_VALUE_UINT_NOTSET; // 00=off, 01=PWM, 02=10V
|
||||
uint8_t solarPumpMinRPM_ = EMS_VALUE_UINT_NOTSET; // minimum RPM setting, *5 %
|
||||
uint8_t solarPumpTurnoffDiff_ = EMS_VALUE_UINT_NOTSET; // solar pump turnoff collector/tank diff
|
||||
uint8_t solarPumpTurnonDiff_ = EMS_VALUE_UINT_NOTSET; // solar pump turnon collector/tank diff
|
||||
uint8_t solarPumpKick_ = EMS_VALUE_UINT_NOTSET; // pump kick for vacuum collector, 00=off
|
||||
uint8_t plainWaterMode_ = EMS_VALUE_UINT_NOTSET; // system does not use antifreeze, 00=off
|
||||
uint8_t doubleMatchFlow_ = EMS_VALUE_UINT_NOTSET; // double Match Flow, 00=off
|
||||
uint8_t collectorTempMax_; // maximum allowable temperature for collector
|
||||
uint8_t tank1MaxTempCurrent_; // Current value for max tank temp
|
||||
uint8_t collectorTempMin_; // minimum allowable temperature for collector
|
||||
uint8_t solarPumpMode_; // 00=off, 01=PWM, 02=10V
|
||||
uint8_t solarPumpMinRPM_; // minimum RPM setting, *5 %
|
||||
uint8_t solarPumpTurnoffDiff_; // solar pump turnoff collector/tank diff
|
||||
uint8_t solarPumpTurnonDiff_; // solar pump turnon collector/tank diff
|
||||
uint8_t solarPumpKick_; // pump kick for vacuum collector, 00=off
|
||||
uint8_t plainWaterMode_; // system does not use antifreeze, 00=off
|
||||
uint8_t doubleMatchFlow_; // double Match Flow, 00=off
|
||||
|
||||
// telegram 0x380
|
||||
uint8_t climateZone_ = EMS_VALUE_UINT_NOTSET; // climate zone identifier
|
||||
uint16_t collector1Area_ = EMS_VALUE_USHORT_NOTSET; // Area of collector field 1
|
||||
uint8_t collector1Type_ = EMS_VALUE_UINT_NOTSET; // Type of collector field 1, 01=flat, 02=vacuum
|
||||
uint8_t climateZone_; // climate zone identifier
|
||||
uint16_t collector1Area_; // Area of collector field 1
|
||||
uint8_t collector1Type_; // Type of collector field 1, 01=flat, 02=vacuum
|
||||
|
||||
bool changed_ = false;
|
||||
bool mqtt_ha_config_ = false; // for HA MQTT Discovery
|
||||
char type_[20]; // Solar of WWC
|
||||
|
||||
void process_SM10Monitor(std::shared_ptr<const Telegram> telegram);
|
||||
void process_SM100SystemConfig(std::shared_ptr<const Telegram> telegram);
|
||||
|
||||
Reference in New Issue