Paul
059861a14f use flash mem for strings when we can 2020-02-23 14:22:46 +01:00
Paul
97aaff07ef add mqtt queue to help publish failures - #326 #298 2020-02-21 17:51:25 +01:00
Paul
9dc0de275f fix devices scan - #326 2020-02-20 00:01:05 +01:00
Paul
93dff6493a optimize detection of EMS devices 2020-02-19 22:22:12 +01:00
Paul
b4e1d35d86 multiple bus ids - #329 2020-02-18 16:03:54 +01:00
Paul
ce49b37a34 minor formatting - no feature changes 2020-02-16 21:32:10 +01:00
Paul
8443127401 revert last change, only send thermostat MQTT if there is a setpoint temp 2020-02-15 18:01:46 +01:00
proddy
842d47293b fix for boiltemp - should work ith buderus and bosch 2020-02-14 20:24:58 +01:00
Paul
833694a573 always show setpoint pn RC3x0 - #256 2020-02-14 14:49:33 +01:00
Paul
fd24fe3a46 RC300 changes - #256 2020-02-13 15:40:25 +01:00
Paul
ff97b3b70b use dallas sensor address as ID - #327 2020-02-12 22:00:45 +01:00
proddy
c801160351 minor changes to mixing 2020-02-09 22:05:11 +01:00
proddy
55225f7028 ignore setpoint temp on RC300/310 when in night mode - #256 2020-02-08 14:37:15 +01:00
Paul
7f503b166f fix controller/thermostat clash #321 2020-02-04 22:12:29 +01:00
Paul
af3971ef02 increase buffer length to show boiler details 2020-02-03 23:51:49 +01:00
Paul
ec25636d99 some mixing minor changes 2020-02-03 23:35:35 +01:00
Paul
e8e7b22e30 fix RC30 mode - #318 2020-02-03 23:16:26 +01:00
proddy
416cd43e13 added back autodetect scan, added RC30 set temp fix, fixed detection of controllers - #318 #311 2020-02-03 17:52:39 +01:00
Paul
f969226b05 fix for HC detection - #305 2020-02-01 09:07:09 +01:00
Paul
9b3ca30959 fix non-boiler check #317 2020-01-31 22:44:35 +01:00
Paul
ce97c55822 fix for bosch boiler temp #314 and MM10 on HC2 #270 2020-01-31 11:09:58 +01:00
Paul
5140db5444 seperate boiler detection - #317 2020-01-31 00:08:04 +01:00
MichaelDvP
610b9525c7 Merge branch 'dev' of https://github.com/proddy/EMS-ESP.git into MM10 2020-01-29 08:16:25 +01:00
Paul
03489d43f4 force sel temp on RC35 temperature change - #310 2020-01-26 21:10:07 +01:00
MichaelDvP
9ad6bbfadd Merge branch 'dev' of https://github.com/proddy/EMS-ESP.git into MM10 2020-01-20 15:16:53 +01:00
Paul
cd84881769 rename 'stats' to 'data' 2020-01-19 14:53:42 +01:00
MichaelDvP
b950cf8246 summery over last commitsto MM10
- add MM200 warm water circuits (#299)
- add terminal boiler wwactive on/off command (#301)
- show first active thermostat hc in web (instead always 1)
- add log d [id] to show messages from/to specific ID (may replace log t and log s)
- add mixer version to info
- add warm water circulation active to terminal and mqtt
- mqtt subscribe only to active hc
- change NOTSET values for short/ushort and set the compare to level (match 0x7D00, 0x8000 and 0x8300 as notset)
- add calculated flow temperature to thermostat stats
2020-01-18 19:12:53 +01:00
MichaelDvP
093df344e2 Test 2020-01-13 10:25:37 +01:00
MichaelDvP
0fb9019c51 Sync with upstream/dev 2020-01-12 18:41:53 +01:00
MichaelDvP
db4fa83c3c merge with upstream/dev 2020-01-12 13:50:57 +01:00
MichaelDvP
fc13004093 add mqtt-subscription for WWcirculation 2020-01-12 13:46:05 +01:00
Paul
698358f04e correct Mixer module flowtemp in MQTT #270 2020-01-12 12:38:00 +01:00
MichaelDvP
041203936e Merge remote-tracking branch 'upstream/dev' into MM10 2020-01-12 09:59:51 +01:00
MichaelDvP
1c424d372f change command for WW-OneTime 2020-01-12 09:59:19 +01:00
Paul
6b81b57b02 refactor ds18 #287 2020-01-11 22:12:00 +01:00
Paul
c3905e0b33 included showing detection of external temperature sensors in startup and 'autodetect' also re-checks for new external sensors. #238 2020-01-11 16:29:51 +01:00
MichaelDvP
4be2383ad8 Merge remote-tracking branch 'upstream/dev' into MM10 2020-01-09 10:22:36 +01:00
Paul
382946846e increase bus offline timeout from 15 to 45 seconds - #267 2020-01-07 22:04:14 +01:00
Paul
62fff2c3bf #238 - various optimizatons for multiple HCs on RC35s 2020-01-06 21:51:02 +01:00
MichaelDvP
13e87bab97 Merge remote-tracking branch 'upstream/dev' into MM10 2020-01-05 10:49:07 +01:00
Paul
daf24af323 cleaned up detection - #283 2020-01-04 23:15:41 +01:00
MichaelDvP
0537705924 Fix unknown device 2020-01-04 16:05:21 +01:00
Paul
ae61c357c0 fix #285 2020-01-04 15:39:07 +01:00
Paul
4484c6db60 #284 #283 2020-01-04 13:49:11 +01:00
Paul
5577685d85 bug fix for processing version when no match found 2020-01-03 21:19:22 +01:00
Paul
5ce0b64bb4 support for multiple productids - #278 2020-01-03 13:10:26 +01:00
Paul
0af60a320d writing to Junkers thermostats - #138 2020-01-03 11:24:12 +01:00
Paul
18c6f7a7b7 clean up HCs - #238 2020-01-02 22:45:13 +01:00
Paul
d2316518ac don't detect HCs if there not active - #238 2020-01-02 18:05:40 +01:00
Paul
c8b4f57b32 rollback MM10 HC2 (which isn't) 2020-01-01 21:59:21 +01:00