Paul
42d6cb1c9d
added @PhillyGilly SM200 PR - #267
2020-02-26 12:14:16 +01:00
proddy
459610be51
text changes
2020-02-25 16:58:28 +01:00
Paul
5d7feb1722
added 2 x warm water boiler temps
2020-02-23 15:47:14 +01:00
Paul
059861a14f
use flash mem for strings when we can
2020-02-23 14:22:46 +01:00
Paul
97aaff07ef
add mqtt queue to help publish failures - #326 #298
2020-02-21 17:51:25 +01:00
Paul
9dc0de275f
fix devices scan - #326
2020-02-20 00:01:05 +01:00
Paul
93dff6493a
optimize detection of EMS devices
2020-02-19 22:22:12 +01:00
Paul
b4e1d35d86
multiple bus ids - #329
2020-02-18 16:03:54 +01:00
Paul
ce49b37a34
minor formatting - no feature changes
2020-02-16 21:32:10 +01:00
Paul
8443127401
revert last change, only send thermostat MQTT if there is a setpoint temp
2020-02-15 18:01:46 +01:00
proddy
842d47293b
fix for boiltemp - should work ith buderus and bosch
2020-02-14 20:24:58 +01:00
Paul
833694a573
always show setpoint pn RC3x0 - #256
2020-02-14 14:49:33 +01:00
Paul
fd24fe3a46
RC300 changes - #256
2020-02-13 15:40:25 +01:00
Paul
ff97b3b70b
use dallas sensor address as ID - #327
2020-02-12 22:00:45 +01:00
proddy
c801160351
minor changes to mixing
2020-02-09 22:05:11 +01:00
proddy
55225f7028
ignore setpoint temp on RC300/310 when in night mode - #256
2020-02-08 14:37:15 +01:00
Paul
7f503b166f
fix controller/thermostat clash #321
2020-02-04 22:12:29 +01:00
Paul
af3971ef02
increase buffer length to show boiler details
2020-02-03 23:51:49 +01:00
Paul
ec25636d99
some mixing minor changes
2020-02-03 23:35:35 +01:00
Paul
e8e7b22e30
fix RC30 mode - #318
2020-02-03 23:16:26 +01:00
proddy
416cd43e13
added back autodetect scan, added RC30 set temp fix, fixed detection of controllers - #318 #311
2020-02-03 17:52:39 +01:00
Paul
f969226b05
fix for HC detection - #305
2020-02-01 09:07:09 +01:00
Paul
9b3ca30959
fix non-boiler check #317
2020-01-31 22:44:35 +01:00
Paul
ce97c55822
fix for bosch boiler temp #314 and MM10 on HC2 #270
2020-01-31 11:09:58 +01:00
Paul
5140db5444
seperate boiler detection - #317
2020-01-31 00:08:04 +01:00
MichaelDvP
610b9525c7
Merge branch 'dev' of https://github.com/proddy/EMS-ESP.git into MM10
2020-01-29 08:16:25 +01:00
Paul
03489d43f4
force sel temp on RC35 temperature change - #310
2020-01-26 21:10:07 +01:00
MichaelDvP
9ad6bbfadd
Merge branch 'dev' of https://github.com/proddy/EMS-ESP.git into MM10
2020-01-20 15:16:53 +01:00
Paul
cd84881769
rename 'stats' to 'data'
2020-01-19 14:53:42 +01:00
MichaelDvP
b950cf8246
summery over last commitsto MM10
...
- add MM200 warm water circuits (#299 )
- add terminal boiler wwactive on/off command (#301 )
- show first active thermostat hc in web (instead always 1)
- add log d [id] to show messages from/to specific ID (may replace log t and log s)
- add mixer version to info
- add warm water circulation active to terminal and mqtt
- mqtt subscribe only to active hc
- change NOTSET values for short/ushort and set the compare to level (match 0x7D00, 0x8000 and 0x8300 as notset)
- add calculated flow temperature to thermostat stats
2020-01-18 19:12:53 +01:00
MichaelDvP
093df344e2
Test
2020-01-13 10:25:37 +01:00
MichaelDvP
0fb9019c51
Sync with upstream/dev
2020-01-12 18:41:53 +01:00
MichaelDvP
db4fa83c3c
merge with upstream/dev
2020-01-12 13:50:57 +01:00
MichaelDvP
fc13004093
add mqtt-subscription for WWcirculation
2020-01-12 13:46:05 +01:00
Paul
698358f04e
correct Mixer module flowtemp in MQTT #270
2020-01-12 12:38:00 +01:00
MichaelDvP
041203936e
Merge remote-tracking branch 'upstream/dev' into MM10
2020-01-12 09:59:51 +01:00
MichaelDvP
1c424d372f
change command for WW-OneTime
2020-01-12 09:59:19 +01:00
Paul
6b81b57b02
refactor ds18 #287
2020-01-11 22:12:00 +01:00
Paul
c3905e0b33
included showing detection of external temperature sensors in startup and 'autodetect' also re-checks for new external sensors. #238
2020-01-11 16:29:51 +01:00
MichaelDvP
4be2383ad8
Merge remote-tracking branch 'upstream/dev' into MM10
2020-01-09 10:22:36 +01:00
Paul
382946846e
increase bus offline timeout from 15 to 45 seconds - #267
2020-01-07 22:04:14 +01:00
Paul
62fff2c3bf
#238 - various optimizatons for multiple HCs on RC35s
2020-01-06 21:51:02 +01:00
MichaelDvP
13e87bab97
Merge remote-tracking branch 'upstream/dev' into MM10
2020-01-05 10:49:07 +01:00
Paul
daf24af323
cleaned up detection - #283
2020-01-04 23:15:41 +01:00
MichaelDvP
0537705924
Fix unknown device
2020-01-04 16:05:21 +01:00
Paul
ae61c357c0
fix #285
2020-01-04 15:39:07 +01:00
Paul
4484c6db60
#284 #283
2020-01-04 13:49:11 +01:00
Paul
5577685d85
bug fix for processing version when no match found
2020-01-03 21:19:22 +01:00
Paul
5ce0b64bb4
support for multiple productids - #278
2020-01-03 13:10:26 +01:00
Paul
0af60a320d
writing to Junkers thermostats - #138
2020-01-03 11:24:12 +01:00