Vuego123
712e0b3e8c
FixedSpacingForSolarPumpTime
...
fixed spacing
2019-06-27 23:26:02 +02:00
Vuego123
55ff267828
AddedISM1SolarPumpWorkingTime
...
Added ISM1 Solar Pump Working Time
2019-06-27 23:07:19 +02:00
Paul
4e50d13bd1
add tx_mode back as new tx code can cause resets
2019-06-26 22:02:16 +02:00
Proddy
a6a03e6485
Merge pull request #137 from Vuego123/SolarLogginOnly&BugfixSolar
...
SolarLoggingOnly&Bugfix
2019-06-26 11:45:21 +02:00
Paul
bdf18b091d
support for web server and reset firmware option
2019-06-24 23:40:01 +02:00
Vuego123
9c4e2b5da0
SolarLoggingOnly&Bugfix
...
- Added solar only logging option
- Added a callback message to set the setpoint of the maximum solar boiler temperature.
-fixed bug with wrong device_id for solar
2019-06-23 23:57:57 +02:00
Paul
4b28a1d9b5
add check for max telegram length
2019-06-23 23:55:16 +02:00
Paul
f2da43f759
https://github.com/proddy/EMS-ESP/pull/135
2019-06-20 09:31:21 +02:00
Paul
0b0f65c841
auto formatting
2019-06-20 09:30:42 +02:00
Paul
54922fe9cb
https://github.com/proddy/EMS-ESP/issues/133
2019-06-20 09:30:28 +02:00
Vuego123
b984b9e3d8
SplitSolarModuleFromOtherDevices
...
Solar modules upgrades: a separate Solar Module types list (no longer part of other devices). Made a separate _EMS_SolarModule class (no longer part of _EMS_Other). And updated all code that was impacted by that change.
Also added a device description for solar modules.
Tests on my setup (telnet & MQTT) work as before.
2019-06-20 00:16:34 +02:00
proddy
f320095034
fix rendering for unset SM values
2019-06-19 14:41:05 +02:00
proddy
1171608d33
added Easy for Nefit
2019-06-19 14:40:49 +02:00
Paul
ffacc66d9e
fix how json default values are set
2019-06-18 22:13:30 +02:00
Paul
47f2636a53
publish_wait to publish_time
2019-06-17 21:30:07 +02:00
Paul
4ccec0a6f3
1.8.1
2019-06-17 21:29:49 +02:00
Vuego123
1872a0d57a
Added extra values for ISM1
...
Add measures for energy production (in Wh) and solar pomp (on/off)
2019-06-16 15:56:18 +02:00
Paul
70972ccf6a
preparing for next 1.9.0dev
2019-06-15 15:53:06 +02:00
Paul
3766780cab
version 1.8.0 final
2019-06-15 15:24:56 +02:00
Paul
011771a746
added comment
2019-06-15 12:36:54 +02:00
Paul
cbeadd19c0
bump
2019-06-15 12:36:46 +02:00
Proddy
332461c1de
Merge pull request #130 from Vuego123:bugfix-FR10-&-FW100-wrong-temp.-divider
...
FW100 & FR10 fixed wrong temperature divider
2019-06-11 22:28:41 +02:00
Paul
40659df6be
optimize Tx to handle phantom brk
2019-06-11 22:27:46 +02:00
Paul
c85e9d756b
bump
2019-06-11 22:27:32 +02:00
Paul
08c4a11ac8
update text
2019-06-11 22:25:59 +02:00
Vuego123
c3ab74862d
FW100 & ISM1 fixed wrong temperature divider
2019-06-11 00:43:27 +02:00
Paul
68091b8042
https://github.com/proddy/EMS-ESP/issues/117
2019-06-10 12:30:00 +02:00
Paul
4ee2cc0f6c
improved crash detection
2019-06-09 22:12:38 +02:00
Paul
58a244ab2a
clear list on autodetect
2019-06-08 22:35:37 +02:00
Paul
b3bdcd2228
merged Junkers FW100 & ISM1
2019-06-08 17:22:22 +02:00
Proddy
25f79fb0ad
Merge pull request #121 from Vuego123:Added-Solar-Module-Junkers-ISM1
...
Solar Module Junkers ISM1
2019-06-08 17:20:05 +02:00
Paul
fcce0f6f72
Merge branch 'dev' of https://github.com/proddy/EMS-ESP-Boiler into dev
2019-06-08 17:18:50 +02:00
Paul
4b7db73e74
cosemtic changes
2019-06-08 17:18:38 +02:00
Proddy
7fc1616066
Merge pull request #128 from Vuego123:Added-Thermostat-Junkers-FW100
...
Added support for Junkers FW100
2019-06-08 17:16:20 +02:00
Vuego123
ada33d6585
Added support for Junkers FW100
...
Added FW100 device id,
Added FW100 support to the FR10 (+renamed to Junkers Status message)
Added callback method and improved showInfo and PublishValues in ems-esp.cpp
2019-06-05 23:31:34 +02:00
proddy
1d10d98fd5
philrich fix for junkers https://github.com/proddy/EMS-ESP/issues/103#issuecomment-498187147
2019-06-05 22:36:15 +02:00
proddy
c56cdf16d8
bump
2019-06-05 22:35:25 +02:00
proddy
f0cf3b8b70
new devices
2019-06-05 22:35:16 +02:00
Vuego123
51f8b55fe8
Solar Module Junkers ISM1
...
Added support to read collector temperature and solar boiler temperature for Solar Module Junkers ISM1
2019-06-01 23:42:30 +02:00
proddy
17a75fb06e
fix tapwater off
2019-05-28 21:15:57 +02:00
proddy
c3427be109
detect junkers on startup
2019-05-28 19:39:25 +02:00
proddy
b869bc1d75
detect junkers on startup
2019-05-28 11:57:04 +02:00
proddy
2b494d8bc8
bump
2019-05-27 22:14:07 +02:00
proddy
4d974bbfa0
set emsReverse if a Junkers heatronic is detected
2019-05-27 22:13:37 +02:00
proddy
16fc383a40
fix to tx_mode
2019-05-27 14:40:26 +02:00
Susis Strolch
fdebf6bbdf
tx_mode=2: compensate phantom BRK
2019-05-27 12:47:06 +02:00
Susis Strolch
078f89ce7e
Merge branch 'dev' of https://github.com/proddy/EMS-ESP-Boiler into dev
...
* 'dev' of https://github.com/proddy/EMS-ESP-Boiler :
heatpump minor changes
2019-05-27 10:53:07 +02:00
proddy
1bea0d9f62
heatpump minor changes
2019-05-27 10:12:36 +02:00
Susis Strolch
5479313e53
smart-tx - tx_mode 2 solved
...
after sending the byte we wait until we receive the busmaster response.
sending the BRK is done in loopback mode.
Only caveat: we will get a phantom \0 in Rx FIFO
2019-05-27 10:08:01 +02:00
proddy
45741c7744
https://github.com/proddy/EMS-ESP/issues/117
2019-05-26 17:57:35 +02:00