MichaelDvP
|
a8f997670c
|
add v2.1.1b7 changes, json sizes
|
2020-12-14 16:23:47 +01:00 |
|
proddy
|
ffa313ebe4
|
refactor device value rendering (to Web, Console or MQTT) to base class #632
|
2020-12-13 22:52:34 +01:00 |
|
MichaelDvP
|
0567f9176b
|
maintenance message and command
|
2020-11-30 19:59:34 +01:00 |
|
MichaelDvP
|
e251042897
|
boiler maintenance and time units
|
2020-11-30 17:05:58 +01:00 |
|
Henne Van Och
|
9ccf3966d9
|
Add % as unit of measurement for the valve status
|
2020-11-30 12:12:45 +01:00 |
|
proddy
|
d840c61af3
|
use publish_ha() for HA config topics
|
2020-11-29 21:06:43 +01:00 |
|
proddy
|
cbb0953f44
|
auto formatting
|
2020-11-27 20:53:05 +01:00 |
|
MichaelDvP
|
c3228c3b30
|
boiler information #633, time-textformat web, console
|
2020-11-27 13:27:41 +01:00 |
|
proddy
|
18b6dc645f
|
web and shell printing share common functions - refactor how device values are printed to shell #632
|
2020-11-26 23:06:56 +01:00 |
|
proddy
|
ac1f8c0c58
|
code optimizations based on static analysis checks
|
2020-11-23 18:15:47 +01:00 |
|
MichaelDvP
|
d47a6f36af
|
fix MM100 pump status #629
It was fixed in #486, something happend that it was wrong again.
|
2020-11-23 15:29:26 +01:00 |
|
proddy
|
ffd2f6fe73
|
always register HA for each HC
|
2020-11-23 13:15:41 +01:00 |
|
proddy
|
3e86a48e2b
|
some minor formatting
|
2020-11-23 13:13:29 +01:00 |
|
proddy
|
16f61cc6c3
|
remove this->
|
2020-11-22 16:16:49 +01:00 |
|
proddy
|
0da8f92496
|
remove this->, rename flags to model
|
2020-11-22 16:16:09 +01:00 |
|
MichaelDvP
|
01e1c6e25b
|
fix heating/tapwater #620
|
2020-11-22 09:45:33 +01:00 |
|
MichaelDvP
|
ce490545ff
|
add HA targetflowtemp to RC300
|
2020-11-21 09:19:18 +01:00 |
|
MichaelDvP
|
0639b3923e
|
RC300 offsettemp factor, fetch curve-setpoint
|
2020-11-21 09:09:58 +01:00 |
|
MichaelDvP
|
bfc7555dd2
|
boiler exhausttemp in e5
|
2020-11-21 09:01:49 +01:00 |
|
MichaelDvP
|
32cce931e5
|
3-char serviceCode
|
2020-11-20 12:12:27 +01:00 |
|
MichaelDvP
|
6fac688bbd
|
servicecode, heating_active in E4 telegram, #620
|
2020-11-20 10:48:11 +01:00 |
|
MichaelDvP
|
93bc5c2793
|
fix RC300 offsettemp, minexttemp #599
|
2020-11-20 10:47:17 +01:00 |
|
proddy
|
cd6bc7457d
|
auto formatting
|
2020-11-18 19:15:18 +01:00 |
|
MichaelDvP
|
780be4ff57
|
watch unknown and fixes (see #619 comments)
|
2020-11-18 13:33:21 +01:00 |
|
MichaelDvP
|
9e6b2088ae
|
addWM10 switch
|
2020-11-18 10:41:26 +01:00 |
|
MichaelDvP
|
cf3728759e
|
devices, json-ha-config
|
2020-11-18 10:17:57 +01:00 |
|
MichaelDvP
|
d41cb6eda2
|
Thermostat: json sizes/split, add circpump, add last Error, check HC
|
2020-11-18 10:17:03 +01:00 |
|
MichaelDvP
|
bfeca075ba
|
Boiler: add reset, add last code, json output 2 parts (main/ww)
|
2020-11-18 10:13:24 +01:00 |
|
proddy
|
45b55acc43
|
prevent HA climate component being created if there is no current room temp - #582
|
2020-11-17 21:54:09 +01:00 |
|
proddy
|
52e120aea2
|
minor updates to solar cfg - #616
|
2020-11-17 18:12:29 +01:00 |
|
Proddy
|
4504f25016
|
Merge pull request #613 from hpanther/dev
Updates to the solar device to handle configuration-related telegrams
|
2020-11-17 17:50:00 +01:00 |
|
proddy
|
6c513140f9
|
auto formatting
|
2020-11-16 21:16:42 +01:00 |
|
proddy
|
1f07c38440
|
fix ha mqtt parsing hc number - #609
|
2020-11-15 20:15:46 +01:00 |
|
MichaelDvP
|
fe67e785f5
|
fix rc300 heatingcurve #610
|
2020-11-15 17:31:14 +01:00 |
|
hpanther
|
8a301e368f
|
Review feedback - correct types and telegram examples
|
2020-11-15 13:52:40 +01:00 |
|
hpanther
|
a2c34c87dd
|
Fix type for esp32
|
2020-11-15 11:48:16 +01:00 |
|
hpanther
|
91b8dcaade
|
Merge remote-tracking branch 'upstream/dev' into dev
|
2020-11-14 22:54:53 +01:00 |
|
hpanther
|
d5fcc25f94
|
Added all known solar config items and implemented 0xF9 telegram correctly
|
2020-11-14 22:50:32 +01:00 |
|
proddy
|
bcac102bbd
|
fix HA config for Mixing, #602
|
2020-11-14 17:33:13 +01:00 |
|
proddy
|
cb9795ec82
|
increase mqtt size just in case
|
2020-11-14 17:31:17 +01:00 |
|
proddy
|
16dd1dab71
|
updated test
|
2020-11-14 16:57:01 +01:00 |
|
MichaelDvP
|
1578168167
|
split HA-config in smaller blocks, add publish command
|
2020-11-13 13:32:18 +01:00 |
|
MichaelDvP
|
f5b7bad2fb
|
thermostat typos, trigger new dev build
|
2020-11-11 09:25:36 +01:00 |
|
MichaelDvP
|
82a35f9a7e
|
fix compile warnings/errors
|
2020-11-10 12:46:26 +01:00 |
|
MichaelDvP
|
8c62977ad3
|
thermostat minflowtemp and fixes
|
2020-11-10 11:22:03 +01:00 |
|
proddy
|
5088e3acee
|
auto formatting
|
2020-11-08 20:54:08 +01:00 |
|
MichaelDvP
|
0823c1bbae
|
add heating curve RC300
|
2020-11-08 15:26:22 +01:00 |
|
MichaelDvP
|
f997e88ca0
|
nofrost temperature signed
|
2020-11-06 17:13:34 +01:00 |
|
MichaelDvP
|
f6ee6ec35f
|
show solar pumpWorkMin in shell
|
2020-11-06 14:25:40 +01:00 |
|
MichaelDvP
|
8165e697a7
|
solar pump working time, #598
|
2020-11-06 13:35:29 +01:00 |
|