Commit Graph

1065 Commits

Author SHA1 Message Date
proddy
e11ba9e657 formatting 2025-10-18 17:17:04 +02:00
proddy
878f0702b2 typo 2025-10-18 17:16:53 +02:00
MichaelDvP
766281d8d2 add dhw modetype #2659 2025-10-15 14:32:44 +02:00
MichaelDvP
bd128072c0 fix childlock setting 2025-10-15 10:49:46 +02:00
MichaelDvP
47b3e4bf00 fix srcx/seltemp 2025-10-13 19:58:25 +02:00
MichaelDvP
f0f40bbcac fix src commands, icon 2025-10-13 08:46:22 +02:00
MichaelDvP
036e2917a5 SRC plus: mqtt subscribe, modbus 2025-10-12 11:35:24 +02:00
MichaelDvP
11782eef8b SRC #2636, add childlock, icons, fix long names 2025-10-09 13:25:09 +02:00
MichaelDvP
d39d6c7f1f Junkers old does not support remote thermostats 2025-10-08 12:03:21 +02:00
MichaelDvP
4043eaf271 add tag for SRC plus SingleRoomControllers 2025-10-08 12:02:55 +02:00
MichaelDvP
eb14e89c35 fix writing calIntTemp for remote thermostats #2646 2025-10-07 10:36:48 +02:00
MichaelDvP
8411ea6773 fix forceheatingoff ems+ 2025-10-07 09:35:53 +02:00
MichaelDvP
4cfd9b699c fix misuse of forceheatingoff 2025-10-07 07:23:27 +02:00
MichaelDvP
e9e7162bcd typos, update 2025-10-06 08:59:16 +02:00
MichaelDvP
689a3a9a69 selflowtemp and forceheatingoff for ems+ telegrams (2E0 command) 2025-10-05 09:22:46 +02:00
MichaelDvP
391a312f0c add CR11 calinttemp 2025-10-05 07:45:24 +02:00
MichaelDvP
f782eac0cf rename HA dev_i, SRC: do not fetch inactive circuits, long names, HA climated 2025-10-02 11:49:53 +02:00
MichaelDvP
d88513d789 SRC thermostat test, update1 2025-09-30 08:48:56 +02:00
MichaelDvP
59d07e81d6 test SRC Plus implementation, #2636 2025-09-29 12:47:08 +02:00
MichaelDvP
b1d6ab3c96 ventilation bypass state from 0x55C, #1197 2025-09-26 08:46:11 +02:00
MichaelDvP
3b4e09208e CR11 mode setting, FW200 display settings 2025-08-28 09:12:55 +02:00
MichaelDvP
a50227638b fix boiler wwMaxPower and ww_disinfect, dev16 2025-08-18 17:34:16 +02:00
MichaelDvP
83987b71e0 MM100 flow and pressure 2025-08-02 13:08:09 +02:00
MichaelDvP
8a48da38b8 revert to fetch mixer config 2025-07-31 18:56:17 +02:00
MichaelDvP
bee703eb1f test: fetch MM100 config only once 2025-07-23 11:56:27 +02:00
proddy
97f689b8a7 add comment for reference 2025-06-01 12:41:52 +02:00
MichaelDvP
ca81a02a8c masked enums with single mask, update seltemp in advance 2025-05-23 07:41:43 +02:00
MichaelDvP
2d6e02171f Typo 2025-05-12 16:47:33 +02:00
MichaelDvP
52f59a7b1d fix set chargeoptimization #2543 2025-05-12 08:00:14 +02:00
MichaelDvP
ba2ad4e175 typo 2025-05-11 15:00:41 +02:00
MichaelDvP
b3320c3e48 ha optimistic, cs6800 changes, custom entity hide 2025-05-10 16:14:54 +02:00
MichaelDvP
67b5c5dd26 chargeOptimization #2543, charging pump #2544 2025-05-06 19:14:31 +02:00
MichaelDvP
a02831e04e read only first error log message 2025-04-24 10:23:54 +02:00
MichaelDvP
f9ebe33a7d read thermostat errorlog 0xC0 on 0xBF 2025-04-23 09:36:00 +02:00
proddy
c6b0099581 domoticz warnings on custom entities - https://github.com/emsesp/EMS-ESP32/discussions/2408#discussioncomment-12896868 2025-04-22 16:07:22 +02:00
MichaelDvP
57098b578f fix writing auxHeaterSource #2489 2025-04-22 06:58:23 +02:00
MichaelDvP
c523a379fe add C6 telegram, fixes #1963 2025-04-20 17:07:30 +02:00
MichaelDvP
d7b9754ddb do not create hc on empty message 2025-04-09 17:38:58 +02:00
MichaelDvP
b252c2f95a FB100 controls hc1, fixes #2510 2025-04-08 17:53:06 +02:00
MichaelDvP
3cb29220ab fetch first c0 telegram #2501 2025-04-01 18:58:59 +02:00
MichaelDvP
d91812ab8f add thermostat C0 message #2501 2025-04-01 12:41:21 +02:00
MichaelDvP
c5dbd7452e add auxHeaterSource #2489 2025-03-27 17:23:42 +01:00
MichaelDvP
b5471aef94 fix typo in set_wwswitchtime, fixes #2490 2025-03-26 17:03:51 +01:00
MichaelDvP
f31329ceff fix dhw progMode, #2490 2025-03-26 07:16:08 +01:00
MichaelDvP
40d48f4407 add FLAG_HMC310, fix switchtimeWW 2025-03-25 18:13:43 +01:00
MichaelDvP
4564e0b828 fix printable chars in lastcode 2025-03-23 10:06:49 +01:00
proddy
cd8b1add54 formatting 2025-03-10 21:46:55 +01:00
MichaelDvP
7fd735f667 rename remoteseltemp to cooltemp, fix #2456 2025-03-10 11:02:03 +01:00
MichaelDvP
18bdcfe050 fix lastcode #2438, heating/tapwater for heatpumps from activity #2450 2025-03-07 18:12:36 +01:00
MichaelDvP
c4f6f01f7e fix #2446, pc0Flow for all boilers, fix #2411 2025-03-05 14:20:40 +01:00