# Changelog ## **Important Breaking Changes** - 3.0.0b3 uses a new filesystem. During upgrading all settings will be erased and not migrated. ### Added - Power settings, disabling BLE and turning off Wifi sleep - Rx and Tx counts to Heartbeat MQTT payload - Ethernet support - id to info command to show only a heatingcircuit - add sending devices that are not listed to 0x07 - extra MQTT boolean option for "ON" and "OFF" - Support for chunked MQTT payloads to allow large data sets > 2kb - External Button support (#708) for resetting to factory defaults and other actions - new console set command in `system`, `set ethernet ` for quickly enabling cabled ethernet connections without using the captive wifi portal - Added in MQTT nested mode, for thermostat and mixer, like we had back in v2 - Cascade MC400 (product-id 210) (3.0.0b6) - values for wwMaxPower, wwFlowtempOffset - RC300 `thermostat temp -1` to clear temporary setpoint in auto mode - Syslog port selectable (#744) ### Fixed - telegrams matched to masterthermostat 0x18 - multiple roomcontrollers - readback after write with delay (give ems-devices time to set the value) - Thermostat ES72/RC20 device 66 to command-set RC20_2 - MQTT payloads not adding to queue when MQTT is re-connecting (fixes #369) - fix for HA topics with invalid command formats (#728) - wrong position of values #723, #732 - OTA Upload via Web on OSX ### Changed - changed how telegram parameters are rendered for mqtt, console and web (#632) - split `show values` in smaller packages (edited) - extended length of IP/hostname from 32 to 48 chars (#676) - check flowsensor for `tap_water_active` - mqtt prefixed with `Base` - count Dallas sensor fails - switch from SPIFFS to LITTLEFS - Added ID to MQTT payloads which is the Device's product ID and used in HA to identify a unique HA device - Increased MQTT buffer and reduced wait time between publishes - Updated to the latest ArduinoJson library - some names of mqtt-tags like in v2.2.1 - new ESP32 partition side to allow for smoother OTA and fallback - Network Gateway IP is optional (#682)emsesp/EMS-ESP - moved to a new GitHub repo https://github.com/emsesp/EMS-ESP32 ### Removed