# Changelog # [3.3.0] ## Added - Add system commands for syslog level and watch [#98] - Added pool data to telegrams 0x494 & 0x495 [#102] - Add RC300 second summermode telegram [#108] - Add support for the RC25 thermostat [#106] - Add new command 'entities' for a device, e.g. http://ems-esp/api/boiler/entities to show the shortname, description and HA Entity name (if HA enabled) [#116] - Support for Junkers program and remote (fb10/fb110) temperature - Home Assistant `state_class` attribute for Wh, kWh, W and KW [#129] - Add current room influence for RC300 [#136] - Added Home Assistant device_class to sensor entities - Added another Buderus RC10 thermostat with Product ID 65 [#160] - Added support for mDNS [#161] - Added last system ESP32 reset code to log (and `system info` output) - Firmware Checker in WebUI [#168] - Added new MQTT setting for enabling 'response' topic - Support for non-standard Thermostats like Tado [#174] - Include MQTT connection status in 'api/system/info' ## Fixed - MQTT reconnecting after WiFi reconnect [#99] - Manually Controlling Solar Circuit [#107] - Fix thermostat commands not defaulting to the master thermostat [#110] - Enlarge parse-buffer for long names like `cylinderpumpmodulation` - MQTT not subscribing to all device entities [#166] - Help fix issues with WebUI unable to fully load UI over Ethernet [#177] - Shower alert never reset after limit reached when enabled [(PR #185)] - Remove HA entity entries when a device value goes dormant [#196] ## Changed - Syslog BOM only for utf-8 messages [#91] - Check for KM200 by device-id 0x48, remove tx-delay [#90] - rename `fastheatupfactor` to `fastheatup` and add percent [#122] - "unit" renamed to "uom" in API call to recall a Device Value - initial backend React changes to replace the class components (HOCs) with React Hooks - Use program-names instead of numbers - Boiler's maintenancemessage always published in MQTT (to prevent HA missing entity) - Unit of Measure 'times' added to MQTT Fails, Rx fails, Rx received, Tx fails, Tx reads & Tx writes - Improved API. Restful HTTP API works in the same way as MQTT calls - Removed settings for MQTT subscribe format [#173] - Improve moduline 200 functionality [#183] ## **BREAKING CHANGES** - API: "unit" renamed to "uom" in API call to recall a Device Value - HA: `sensor.boiler_boiler_temperature` renamed to `sensor.actual_boiler_temperature` - HA: `binary_sensor.boiler_ww_disinfecting` renamed to `binary_sensor.boiler_ww_disinfection` - HA: # removed from counts in MQTT Fails, Rx fails, Rx received, Tx fails, Tx reads & Tx writes - `txread` renamed to `txreads` and `txwrite` renamed to `txwrites` in MQTT heartbeat payload - 'dallas sensors' in api/system/info moved to the "System" section. Renamed "uptime (seconds)" and "reset reason"