device name,device type,product id,shortname,fullname,type [options...] \| (min/max),uom,writeable,discovery entityid v3.4, discovery entityid CS6800i/WLW176i,boiler,8,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset CS6800i/WLW176i,boiler,8,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff CS6800i/WLW176i,boiler,8,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive CS6800i/WLW176i,boiler,8,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive CS6800i/WLW176i,boiler,8,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp CS6800i/WLW176i,boiler,8,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod CS6800i/WLW176i,boiler,8,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp CS6800i/WLW176i,boiler,8,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp CS6800i/WLW176i,boiler,8,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp CS6800i/WLW176i,boiler,8,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp CS6800i/WLW176i,boiler,8,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress CS6800i/WLW176i,boiler,8,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp CS6800i/WLW176i,boiler,8,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp CS6800i/WLW176i,boiler,8,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated CS6800i/WLW176i,boiler,8,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp CS6800i/WLW176i,boiler,8,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump CS6800i/WLW176i,boiler,8,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax CS6800i/WLW176i,boiler,8,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin CS6800i/WLW176i,boiler,8,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode CS6800i/WLW176i,boiler,8,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay CS6800i/WLW176i,boiler,8,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp CS6800i/WLW176i,boiler,8,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow CS6800i/WLW176i,boiler,8,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow CS6800i/WLW176i,boiler,8,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow CS6800i/WLW176i,boiler,8,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts CS6800i/WLW176i,boiler,8,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin CS6800i/WLW176i,boiler,8,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin CS6800i/WLW176i,boiler,8,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin CS6800i/WLW176i,boiler,8,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts CS6800i/WLW176i,boiler,8,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime CS6800i/WLW176i,boiler,8,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode CS6800i/WLW176i,boiler,8,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode CS6800i/WLW176i,boiler,8,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber CS6800i/WLW176i,boiler,8,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage CS6800i/WLW176i,boiler,8,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance CS6800i/WLW176i,boiler,8,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime CS6800i/WLW176i,boiler,8,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate CS6800i/WLW176i,boiler,8,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops CS6800i/WLW176i,boiler,8,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp CS6800i/WLW176i,boiler,8,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal CS6800i/WLW176i,boiler,8,nrgww,energy,ulong (>=0<=167772),kWh,false,sensor.boiler_energy,sensor.boiler_nrgww CS6800i/WLW176i,boiler,8,nrgheat,energy heating,ulong (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat CS6800i/WLW176i,boiler,8,metertotal,meter total,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal CS6800i/WLW176i,boiler,8,metercomp,meter compressor,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp CS6800i/WLW176i,boiler,8,metereheat,meter e-heater,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat CS6800i/WLW176i,boiler,8,meterheat,meter heating,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat CS6800i/WLW176i,boiler,8,meterww,meter,ulong (>=0<=167772),kWh,false,sensor.boiler_meter,sensor.boiler_meterww CS6800i/WLW176i,boiler,8,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal CS6800i/WLW176i,boiler,8,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol CS6800i/WLW176i,boiler,8,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating CS6800i/WLW176i,boiler,8,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling CS6800i/WLW176i,boiler,8,uptimecompww,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor,sensor.boiler_uptimecompww CS6800i/WLW176i,boiler,8,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool CS6800i/WLW176i,boiler,8,totalcompstarts,total compressor control starts,ulong (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts CS6800i/WLW176i,boiler,8,heatingstarts,heating control starts,ulong (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts CS6800i/WLW176i,boiler,8,coolingstarts,cooling control starts,ulong (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts CS6800i/WLW176i,boiler,8,wwstarts2,control starts2,ulong (>=0<=16777213), ,false,sensor.boiler_control_starts2,sensor.boiler_wwstarts2 CS6800i/WLW176i,boiler,8,poolstarts,pool control starts,ulong (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts CS6800i/WLW176i,boiler,8,nrgconstotal,total energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal CS6800i/WLW176i,boiler,8,nrgconscomptotal,total energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal CS6800i/WLW176i,boiler,8,nrgconscompheating,energy consumption compressor heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating CS6800i/WLW176i,boiler,8,nrgconscompww,energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor,sensor.boiler_nrgconscompww CS6800i/WLW176i,boiler,8,nrgconscompcooling,energy consumption compressor cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling CS6800i/WLW176i,boiler,8,nrgconscomppool,energy consumption compressor pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool CS6800i/WLW176i,boiler,8,auxelecheatnrgconstotal,total aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal CS6800i/WLW176i,boiler,8,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating CS6800i/WLW176i,boiler,8,auxelecheatnrgconsww,aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconsww CS6800i/WLW176i,boiler,8,auxelecheatnrgconspool,aux elec. heater energy consumption pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool CS6800i/WLW176i,boiler,8,nrgsupptotal,total energy supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal CS6800i/WLW176i,boiler,8,nrgsuppheating,total energy supplied heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating CS6800i/WLW176i,boiler,8,nrgsuppww,total energy warm supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_warm_supplied,sensor.boiler_nrgsuppww CS6800i/WLW176i,boiler,8,nrgsuppcooling,total energy supplied cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling CS6800i/WLW176i,boiler,8,nrgsupppool,total energy supplied pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool CS6800i/WLW176i,boiler,8,hppower,compressor power output,uint (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower CS6800i/WLW176i,boiler,8,hpmaxpower,compressor max power,uint (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower CS6800i/WLW176i,boiler,8,hpsetdiffpress,set differental pressure,uint (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress CS6800i/WLW176i,boiler,8,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon CS6800i/WLW176i,boiler,8,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity CS6800i/WLW176i,boiler,8,hpbrinepumpspd,brine pump speed,uint (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd CS6800i/WLW176i,boiler,8,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve CS6800i/WLW176i,boiler,8,hpcompspd,compressor speed,uint (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd CS6800i/WLW176i,boiler,8,hpcircspd,circulation pump speed,uint (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd CS6800i/WLW176i,boiler,8,hpbrinein,brine in/evaporator,short (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein CS6800i/WLW176i,boiler,8,hpbrineout,brine out/condenser,short (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout CS6800i/WLW176i,boiler,8,hptc0,heat carrier return (TC0),short (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0 CS6800i/WLW176i,boiler,8,hptc1,heat carrier forward (TC1),short (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1 CS6800i/WLW176i,boiler,8,hptc3,condenser temperature (TC3),short (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3 CS6800i/WLW176i,boiler,8,hptr1,compressor temperature (TR1),short (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1 CS6800i/WLW176i,boiler,8,hptr3,refrigerant temperature liquid side (condenser output) (TR3),short (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3 CS6800i/WLW176i,boiler,8,hptr4,evaporator inlet temperature (TR4),short (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4 CS6800i/WLW176i,boiler,8,hptr5,compressor inlet temperature (TR5),short (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5 CS6800i/WLW176i,boiler,8,hptr6,compressor outlet temperature (TR6),short (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6 CS6800i/WLW176i,boiler,8,hptr7,refrigerant temperature gas side (condenser input) (TR7),short (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7 CS6800i/WLW176i,boiler,8,hptl2,air inlet temperature (TL2),short (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2 CS6800i/WLW176i,boiler,8,hppl1,low pressure side temperature (PL1),short (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1 CS6800i/WLW176i,boiler,8,hpph1,high pressure side temperature (PH1),short (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1 CS6800i/WLW176i,boiler,8,hpta4,drain pan temp (TA4),short (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4 CS6800i/WLW176i,boiler,8,hptw1,reservoir temp (TW1),short (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1 CS6800i/WLW176i,boiler,8,poolsettemp,pool set temperature,uint (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp CS6800i/WLW176i,boiler,8,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way CS6800i/WLW176i,boiler,8,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt CS6800i/WLW176i,boiler,8,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt CS6800i/WLW176i,boiler,8,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt CS6800i/WLW176i,boiler,8,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt CS6800i/WLW176i,boiler,8,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp CS6800i/WLW176i,boiler,8,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat CS6800i/WLW176i,boiler,8,maxheatdhw,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit,select.boiler_maxheatdhw CS6800i/WLW176i,boiler,8,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost CS6800i/WLW176i,boiler,8,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling CS6800i/WLW176i,boiler,8,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly CS6800i/WLW176i,boiler,8,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff CS6800i/WLW176i,boiler,8,auxheaterstatus,aux heater status,boolean, ,false,binary_sensor.boiler_aux_heater_status,binary_sensor.boiler_auxheaterstatus CS6800i/WLW176i,boiler,8,auxheaterdelay,aux heater on delay,ushort (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay CS6800i/WLW176i,boiler,8,auxmaxlimit,aux heater max limit,uint (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit CS6800i/WLW176i,boiler,8,auxlimitstart,aux heater limit start,uint (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart CS6800i/WLW176i,boiler,8,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode CS6800i/WLW176i,boiler,8,hphystheat,on/off hyst heat,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat CS6800i/WLW176i,boiler,8,hphystcool,on/off hyst cool,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool CS6800i/WLW176i,boiler,8,hphystpool,on/off hyst pool,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool CS6800i/WLW176i,boiler,8,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode CS6800i/WLW176i,boiler,8,silentfrom,silent mode from,uint (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom CS6800i/WLW176i,boiler,8,silentto,silent mode to,uint (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto CS6800i/WLW176i,boiler,8,mintempsilent,min outside temp for silent mode,int (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent CS6800i/WLW176i,boiler,8,tempparmode,outside temp parallel mode,int (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode CS6800i/WLW176i,boiler,8,auxheatmix,aux heater mixing valve,int (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix CS6800i/WLW176i,boiler,8,tempdiffheat,temp diff TC3/TC0 heat,uint (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat CS6800i/WLW176i,boiler,8,tempdiffcool,temp diff TC3/TC0 cool,uint (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool CS6800i/WLW176i,boiler,8,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling CS6800i/WLW176i,boiler,8,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable CS6800i/WLW176i,boiler,8,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve CS6800i/WLW176i,boiler,8,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump CS6800i/WLW176i,boiler,8,primepumpmod,primary heatpump modulation,uint (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod CS6800i/WLW176i,boiler,8,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way CS6800i/WLW176i,boiler,8,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1 CS6800i/WLW176i,boiler,8,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2 CS6800i/WLW176i,boiler,8,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3 CS6800i/WLW176i,boiler,8,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0 CS6800i/WLW176i,boiler,8,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode CS6800i/WLW176i,boiler,8,wwalternatingop,alternating operation,boolean, ,true,switch.boiler_alternating_operation,switch.boiler_wwalternatingop CS6800i/WLW176i,boiler,8,wwaltopprioheat,prioritise heating during dhw,uint (>=20<=120),minutes,true,number.boiler_prioritise_heating_during_dhw,number.boiler_wwaltopprioheat CS6800i/WLW176i,boiler,8,wwaltopprioww,prioritise dhw during heating,uint (>=30<=120),minutes,true,number.boiler_prioritise_dhw_during_heating,number.boiler_wwaltopprioww CS6800i/WLW176i,boiler,8,wwcomfoff,comfort switch off,uint (>=15<=65),C,true,number.boiler_comfort_switch_off,number.boiler_wwcomfoff CS6800i/WLW176i,boiler,8,wwecooff,eco switch off,uint (>=15<=65),C,true,number.boiler_eco_switch_off,number.boiler_wwecooff CS6800i/WLW176i,boiler,8,wwecoplusoff,eco+ switch off,uint (>=48<=63),C,true,number.boiler_eco+_switch_off,number.boiler_wwecoplusoff CS6800i/WLW176i,boiler,8,wwcomfdiff,comfort diff,uint (>=6<=12),K,true,number.boiler_comfort_diff,number.boiler_wwcomfdiff CS6800i/WLW176i,boiler,8,wwecodiff,eco diff,uint (>=6<=12),K,true,number.boiler_eco_diff,number.boiler_wwecodiff CS6800i/WLW176i,boiler,8,wwecoplusdiff,eco+ diff,uint (>=6<=12),K,true,number.boiler_eco+_diff,number.boiler_wwecoplusdiff CS6800i/WLW176i,boiler,8,wwcomfstop,comfort stop temp,uint (>=0<=254),C,true,number.boiler_comfort_stop_temp,number.boiler_wwcomfstop CS6800i/WLW176i,boiler,8,wwecostop,eco stop temp,uint (>=0<=254),C,true,number.boiler_eco_stop_temp,number.boiler_wwecostop CS6800i/WLW176i,boiler,8,wwecoplusstop,eco+ stop temp,uint (>=0<=254),C,true,number.boiler_eco+_stop_temp,number.boiler_wwecoplusstop CS6800i/WLW176i,boiler,8,hpcircpumpww,circulation pump available during dhw,boolean, ,true,switch.boiler_circulation_pump_available_during_dhw,switch.boiler_hpcircpumpww CS6800i/WLW176i,boiler,8,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated CS6800i/WLW176i,boiler,8,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp CS6800i/WLW176i,boiler,8,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp CS6800i/WLW176i,boiler,8,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow CS6800i/WLW176i,boiler,8,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus CS6800i/WLW176i,boiler,8,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff CS6800i/WLW176i,boiler,8,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle CS6800i/WLW176i,boiler,8,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp CS6800i/WLW176i,boiler,8,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype CS6800i/WLW176i,boiler,8,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort CS6800i/WLW176i,boiler,8,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 CS6800i/WLW176i,boiler,8,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset CS6800i/WLW176i,boiler,8,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization CS6800i/WLW176i,boiler,8,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower CS6800i/WLW176i,boiler,8,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp CS6800i/WLW176i,boiler,8,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump CS6800i/WLW176i,boiler,8,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype CS6800i/WLW176i,boiler,8,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston CS6800i/WLW176i,boiler,8,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff CS6800i/WLW176i,boiler,8,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp CS6800i/WLW176i,boiler,8,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode CS6800i/WLW176i,boiler,8,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc CS6800i/WLW176i,boiler,8,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp CS6800i/WLW176i,boiler,8,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 CS6800i/WLW176i,boiler,8,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow CS6800i/WLW176i,boiler,8,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 CS6800i/WLW176i,boiler,8,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 CS6800i/WLW176i,boiler,8,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated CS6800i/WLW176i,boiler,8,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime CS6800i/WLW176i,boiler,8,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting CS6800i/WLW176i,boiler,8,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging CS6800i/WLW176i,boiler,8,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging CS6800i/WLW176i,boiler,8,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok CS6800i/WLW176i,boiler,8,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive CS6800i/WLW176i,boiler,8,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve CS6800i/WLW176i,boiler,8,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower CS6800i/WLW176i,boiler,8,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp CS6800i/WLW176i,boiler,8,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp CS6800i/WLW176i,boiler,8,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts CS6800i/WLW176i,boiler,8,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm C1200W,boiler,12,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset C1200W,boiler,12,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff C1200W,boiler,12,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive C1200W,boiler,12,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive C1200W,boiler,12,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp C1200W,boiler,12,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod C1200W,boiler,12,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp C1200W,boiler,12,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp C1200W,boiler,12,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp C1200W,boiler,12,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp C1200W,boiler,12,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress C1200W,boiler,12,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp C1200W,boiler,12,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp C1200W,boiler,12,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp C1200W,boiler,12,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas C1200W,boiler,12,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 C1200W,boiler,12,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr C1200W,boiler,12,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork C1200W,boiler,12,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork C1200W,boiler,12,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat C1200W,boiler,12,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower C1200W,boiler,12,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower C1200W,boiler,12,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod C1200W,boiler,12,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow C1200W,boiler,12,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock C1200W,boiler,12,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston C1200W,boiler,12,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff C1200W,boiler,12,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston C1200W,boiler,12,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff C1200W,boiler,12,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon C1200W,boiler,12,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase C1200W,boiler,12,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend C1200W,boiler,12,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp C1200W,boiler,12,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode C1200W,boiler,12,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp C1200W,boiler,12,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated C1200W,boiler,12,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp C1200W,boiler,12,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump C1200W,boiler,12,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax C1200W,boiler,12,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin C1200W,boiler,12,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode C1200W,boiler,12,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay C1200W,boiler,12,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp C1200W,boiler,12,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow C1200W,boiler,12,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow C1200W,boiler,12,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow C1200W,boiler,12,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts C1200W,boiler,12,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin C1200W,boiler,12,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin C1200W,boiler,12,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin C1200W,boiler,12,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts C1200W,boiler,12,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime C1200W,boiler,12,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode C1200W,boiler,12,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode C1200W,boiler,12,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber C1200W,boiler,12,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage C1200W,boiler,12,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance C1200W,boiler,12,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime C1200W,boiler,12,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate C1200W,boiler,12,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops C1200W,boiler,12,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp C1200W,boiler,12,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated C1200W,boiler,12,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp C1200W,boiler,12,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp C1200W,boiler,12,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow C1200W,boiler,12,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus C1200W,boiler,12,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff C1200W,boiler,12,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle C1200W,boiler,12,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp C1200W,boiler,12,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype C1200W,boiler,12,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort C1200W,boiler,12,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 C1200W,boiler,12,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset C1200W,boiler,12,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization C1200W,boiler,12,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower C1200W,boiler,12,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp C1200W,boiler,12,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump C1200W,boiler,12,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype C1200W,boiler,12,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston C1200W,boiler,12,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff C1200W,boiler,12,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp C1200W,boiler,12,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode C1200W,boiler,12,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc C1200W,boiler,12,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp C1200W,boiler,12,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 C1200W,boiler,12,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow C1200W,boiler,12,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 C1200W,boiler,12,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 C1200W,boiler,12,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated C1200W,boiler,12,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime C1200W,boiler,12,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting C1200W,boiler,12,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging C1200W,boiler,12,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging C1200W,boiler,12,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok C1200W,boiler,12,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive C1200W,boiler,12,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve C1200W,boiler,12,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower C1200W,boiler,12,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp C1200W,boiler,12,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp C1200W,boiler,12,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts C1200W,boiler,12,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm C1200W,boiler,12,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower C1200W,boiler,12,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal C1200W,boiler,12,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat C1200W,boiler,12,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww BK13/BK15/Smartline/GB1x2,boiler,64,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset BK13/BK15/Smartline/GB1x2,boiler,64,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff BK13/BK15/Smartline/GB1x2,boiler,64,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive BK13/BK15/Smartline/GB1x2,boiler,64,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive BK13/BK15/Smartline/GB1x2,boiler,64,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp BK13/BK15/Smartline/GB1x2,boiler,64,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod BK13/BK15/Smartline/GB1x2,boiler,64,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp BK13/BK15/Smartline/GB1x2,boiler,64,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp BK13/BK15/Smartline/GB1x2,boiler,64,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp BK13/BK15/Smartline/GB1x2,boiler,64,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp BK13/BK15/Smartline/GB1x2,boiler,64,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress BK13/BK15/Smartline/GB1x2,boiler,64,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp BK13/BK15/Smartline/GB1x2,boiler,64,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp BK13/BK15/Smartline/GB1x2,boiler,64,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp BK13/BK15/Smartline/GB1x2,boiler,64,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas BK13/BK15/Smartline/GB1x2,boiler,64,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 BK13/BK15/Smartline/GB1x2,boiler,64,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr BK13/BK15/Smartline/GB1x2,boiler,64,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork BK13/BK15/Smartline/GB1x2,boiler,64,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork BK13/BK15/Smartline/GB1x2,boiler,64,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat BK13/BK15/Smartline/GB1x2,boiler,64,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower BK13/BK15/Smartline/GB1x2,boiler,64,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower BK13/BK15/Smartline/GB1x2,boiler,64,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod BK13/BK15/Smartline/GB1x2,boiler,64,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow BK13/BK15/Smartline/GB1x2,boiler,64,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock BK13/BK15/Smartline/GB1x2,boiler,64,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston BK13/BK15/Smartline/GB1x2,boiler,64,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff BK13/BK15/Smartline/GB1x2,boiler,64,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston BK13/BK15/Smartline/GB1x2,boiler,64,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff BK13/BK15/Smartline/GB1x2,boiler,64,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon BK13/BK15/Smartline/GB1x2,boiler,64,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase BK13/BK15/Smartline/GB1x2,boiler,64,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend BK13/BK15/Smartline/GB1x2,boiler,64,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp BK13/BK15/Smartline/GB1x2,boiler,64,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode BK13/BK15/Smartline/GB1x2,boiler,64,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp BK13/BK15/Smartline/GB1x2,boiler,64,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated BK13/BK15/Smartline/GB1x2,boiler,64,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp BK13/BK15/Smartline/GB1x2,boiler,64,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump BK13/BK15/Smartline/GB1x2,boiler,64,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax BK13/BK15/Smartline/GB1x2,boiler,64,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin BK13/BK15/Smartline/GB1x2,boiler,64,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode BK13/BK15/Smartline/GB1x2,boiler,64,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay BK13/BK15/Smartline/GB1x2,boiler,64,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp BK13/BK15/Smartline/GB1x2,boiler,64,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow BK13/BK15/Smartline/GB1x2,boiler,64,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow BK13/BK15/Smartline/GB1x2,boiler,64,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow BK13/BK15/Smartline/GB1x2,boiler,64,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts BK13/BK15/Smartline/GB1x2,boiler,64,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin BK13/BK15/Smartline/GB1x2,boiler,64,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin BK13/BK15/Smartline/GB1x2,boiler,64,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin BK13/BK15/Smartline/GB1x2,boiler,64,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts BK13/BK15/Smartline/GB1x2,boiler,64,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime BK13/BK15/Smartline/GB1x2,boiler,64,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode BK13/BK15/Smartline/GB1x2,boiler,64,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode BK13/BK15/Smartline/GB1x2,boiler,64,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber BK13/BK15/Smartline/GB1x2,boiler,64,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage BK13/BK15/Smartline/GB1x2,boiler,64,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance BK13/BK15/Smartline/GB1x2,boiler,64,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime BK13/BK15/Smartline/GB1x2,boiler,64,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate BK13/BK15/Smartline/GB1x2,boiler,64,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops BK13/BK15/Smartline/GB1x2,boiler,64,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp BK13/BK15/Smartline/GB1x2,boiler,64,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated BK13/BK15/Smartline/GB1x2,boiler,64,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp BK13/BK15/Smartline/GB1x2,boiler,64,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp BK13/BK15/Smartline/GB1x2,boiler,64,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow BK13/BK15/Smartline/GB1x2,boiler,64,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus BK13/BK15/Smartline/GB1x2,boiler,64,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff BK13/BK15/Smartline/GB1x2,boiler,64,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle BK13/BK15/Smartline/GB1x2,boiler,64,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp BK13/BK15/Smartline/GB1x2,boiler,64,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype BK13/BK15/Smartline/GB1x2,boiler,64,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort BK13/BK15/Smartline/GB1x2,boiler,64,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 BK13/BK15/Smartline/GB1x2,boiler,64,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset BK13/BK15/Smartline/GB1x2,boiler,64,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization BK13/BK15/Smartline/GB1x2,boiler,64,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower BK13/BK15/Smartline/GB1x2,boiler,64,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp BK13/BK15/Smartline/GB1x2,boiler,64,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump BK13/BK15/Smartline/GB1x2,boiler,64,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype BK13/BK15/Smartline/GB1x2,boiler,64,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston BK13/BK15/Smartline/GB1x2,boiler,64,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff BK13/BK15/Smartline/GB1x2,boiler,64,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp BK13/BK15/Smartline/GB1x2,boiler,64,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode BK13/BK15/Smartline/GB1x2,boiler,64,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc BK13/BK15/Smartline/GB1x2,boiler,64,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp BK13/BK15/Smartline/GB1x2,boiler,64,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 BK13/BK15/Smartline/GB1x2,boiler,64,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow BK13/BK15/Smartline/GB1x2,boiler,64,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 BK13/BK15/Smartline/GB1x2,boiler,64,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 BK13/BK15/Smartline/GB1x2,boiler,64,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated BK13/BK15/Smartline/GB1x2,boiler,64,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime BK13/BK15/Smartline/GB1x2,boiler,64,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting BK13/BK15/Smartline/GB1x2,boiler,64,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging BK13/BK15/Smartline/GB1x2,boiler,64,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging BK13/BK15/Smartline/GB1x2,boiler,64,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok BK13/BK15/Smartline/GB1x2,boiler,64,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive BK13/BK15/Smartline/GB1x2,boiler,64,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve BK13/BK15/Smartline/GB1x2,boiler,64,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower BK13/BK15/Smartline/GB1x2,boiler,64,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp BK13/BK15/Smartline/GB1x2,boiler,64,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp BK13/BK15/Smartline/GB1x2,boiler,64,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts BK13/BK15/Smartline/GB1x2,boiler,64,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm BK13/BK15/Smartline/GB1x2,boiler,64,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower BK13/BK15/Smartline/GB1x2,boiler,64,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal BK13/BK15/Smartline/GB1x2,boiler,64,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat BK13/BK15/Smartline/GB1x2,boiler,64,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww GB125/GB135/MC10,boiler,72,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset GB125/GB135/MC10,boiler,72,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff GB125/GB135/MC10,boiler,72,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive GB125/GB135/MC10,boiler,72,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive GB125/GB135/MC10,boiler,72,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp GB125/GB135/MC10,boiler,72,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod GB125/GB135/MC10,boiler,72,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp GB125/GB135/MC10,boiler,72,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp GB125/GB135/MC10,boiler,72,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp GB125/GB135/MC10,boiler,72,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp GB125/GB135/MC10,boiler,72,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress GB125/GB135/MC10,boiler,72,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp GB125/GB135/MC10,boiler,72,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp GB125/GB135/MC10,boiler,72,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp GB125/GB135/MC10,boiler,72,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas GB125/GB135/MC10,boiler,72,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 GB125/GB135/MC10,boiler,72,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr GB125/GB135/MC10,boiler,72,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork GB125/GB135/MC10,boiler,72,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork GB125/GB135/MC10,boiler,72,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat GB125/GB135/MC10,boiler,72,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower GB125/GB135/MC10,boiler,72,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower GB125/GB135/MC10,boiler,72,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod GB125/GB135/MC10,boiler,72,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow GB125/GB135/MC10,boiler,72,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock GB125/GB135/MC10,boiler,72,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston GB125/GB135/MC10,boiler,72,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff GB125/GB135/MC10,boiler,72,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston GB125/GB135/MC10,boiler,72,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff GB125/GB135/MC10,boiler,72,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon GB125/GB135/MC10,boiler,72,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase GB125/GB135/MC10,boiler,72,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend GB125/GB135/MC10,boiler,72,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp GB125/GB135/MC10,boiler,72,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode GB125/GB135/MC10,boiler,72,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp GB125/GB135/MC10,boiler,72,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated GB125/GB135/MC10,boiler,72,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp GB125/GB135/MC10,boiler,72,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump GB125/GB135/MC10,boiler,72,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax GB125/GB135/MC10,boiler,72,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin GB125/GB135/MC10,boiler,72,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode GB125/GB135/MC10,boiler,72,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay GB125/GB135/MC10,boiler,72,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp GB125/GB135/MC10,boiler,72,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow GB125/GB135/MC10,boiler,72,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow GB125/GB135/MC10,boiler,72,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow GB125/GB135/MC10,boiler,72,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts GB125/GB135/MC10,boiler,72,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin GB125/GB135/MC10,boiler,72,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin GB125/GB135/MC10,boiler,72,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin GB125/GB135/MC10,boiler,72,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts GB125/GB135/MC10,boiler,72,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime GB125/GB135/MC10,boiler,72,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode GB125/GB135/MC10,boiler,72,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode GB125/GB135/MC10,boiler,72,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber GB125/GB135/MC10,boiler,72,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage GB125/GB135/MC10,boiler,72,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance GB125/GB135/MC10,boiler,72,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime GB125/GB135/MC10,boiler,72,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate GB125/GB135/MC10,boiler,72,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops GB125/GB135/MC10,boiler,72,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp GB125/GB135/MC10,boiler,72,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated GB125/GB135/MC10,boiler,72,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp GB125/GB135/MC10,boiler,72,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp GB125/GB135/MC10,boiler,72,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow GB125/GB135/MC10,boiler,72,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus GB125/GB135/MC10,boiler,72,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff GB125/GB135/MC10,boiler,72,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle GB125/GB135/MC10,boiler,72,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp GB125/GB135/MC10,boiler,72,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype GB125/GB135/MC10,boiler,72,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort GB125/GB135/MC10,boiler,72,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 GB125/GB135/MC10,boiler,72,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset GB125/GB135/MC10,boiler,72,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization GB125/GB135/MC10,boiler,72,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower GB125/GB135/MC10,boiler,72,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp GB125/GB135/MC10,boiler,72,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump GB125/GB135/MC10,boiler,72,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype GB125/GB135/MC10,boiler,72,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston GB125/GB135/MC10,boiler,72,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff GB125/GB135/MC10,boiler,72,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp GB125/GB135/MC10,boiler,72,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode GB125/GB135/MC10,boiler,72,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc GB125/GB135/MC10,boiler,72,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp GB125/GB135/MC10,boiler,72,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 GB125/GB135/MC10,boiler,72,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow GB125/GB135/MC10,boiler,72,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 GB125/GB135/MC10,boiler,72,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 GB125/GB135/MC10,boiler,72,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated GB125/GB135/MC10,boiler,72,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime GB125/GB135/MC10,boiler,72,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting GB125/GB135/MC10,boiler,72,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging GB125/GB135/MC10,boiler,72,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging GB125/GB135/MC10,boiler,72,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok GB125/GB135/MC10,boiler,72,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive GB125/GB135/MC10,boiler,72,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve GB125/GB135/MC10,boiler,72,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower GB125/GB135/MC10,boiler,72,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp GB125/GB135/MC10,boiler,72,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp GB125/GB135/MC10,boiler,72,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts GB125/GB135/MC10,boiler,72,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm GB125/GB135/MC10,boiler,72,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower GB125/GB135/MC10,boiler,72,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal GB125/GB135/MC10,boiler,72,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat GB125/GB135/MC10,boiler,72,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Cascade CM10,boiler,81,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Cascade CM10,boiler,81,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Cascade CM10,boiler,81,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Cascade CM10,boiler,81,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Cascade CM10,boiler,81,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Cascade CM10,boiler,81,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Cascade CM10,boiler,81,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Cascade CM10,boiler,81,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Cascade CM10,boiler,81,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Cascade CM10,boiler,81,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Cascade CM10,boiler,81,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Cascade CM10,boiler,81,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Cascade CM10,boiler,81,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Cascade CM10,boiler,81,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Cascade CM10,boiler,81,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Cascade CM10,boiler,81,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Cascade CM10,boiler,81,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Cascade CM10,boiler,81,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Cascade CM10,boiler,81,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Cascade CM10,boiler,81,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Cascade CM10,boiler,81,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Cascade CM10,boiler,81,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Cascade CM10,boiler,81,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Cascade CM10,boiler,81,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Cascade CM10,boiler,81,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Cascade CM10,boiler,81,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Cascade CM10,boiler,81,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Cascade CM10,boiler,81,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Cascade CM10,boiler,81,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Cascade CM10,boiler,81,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Cascade CM10,boiler,81,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Cascade CM10,boiler,81,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Cascade CM10,boiler,81,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Cascade CM10,boiler,81,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Cascade CM10,boiler,81,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Cascade CM10,boiler,81,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Cascade CM10,boiler,81,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Cascade CM10,boiler,81,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Cascade CM10,boiler,81,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Cascade CM10,boiler,81,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Cascade CM10,boiler,81,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Cascade CM10,boiler,81,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Cascade CM10,boiler,81,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Cascade CM10,boiler,81,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Cascade CM10,boiler,81,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Cascade CM10,boiler,81,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Cascade CM10,boiler,81,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Cascade CM10,boiler,81,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Cascade CM10,boiler,81,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Cascade CM10,boiler,81,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Cascade CM10,boiler,81,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Cascade CM10,boiler,81,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Cascade CM10,boiler,81,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Cascade CM10,boiler,81,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Cascade CM10,boiler,81,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Cascade CM10,boiler,81,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Cascade CM10,boiler,81,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Cascade CM10,boiler,81,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Cascade CM10,boiler,81,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Cascade CM10,boiler,81,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Cascade CM10,boiler,81,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Cascade CM10,boiler,81,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Cascade CM10,boiler,81,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Cascade CM10,boiler,81,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Cascade CM10,boiler,81,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Cascade CM10,boiler,81,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Cascade CM10,boiler,81,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Cascade CM10,boiler,81,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Cascade CM10,boiler,81,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Cascade CM10,boiler,81,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Cascade CM10,boiler,81,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Cascade CM10,boiler,81,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Cascade CM10,boiler,81,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Cascade CM10,boiler,81,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Cascade CM10,boiler,81,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Cascade CM10,boiler,81,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Cascade CM10,boiler,81,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Cascade CM10,boiler,81,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Cascade CM10,boiler,81,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Cascade CM10,boiler,81,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Cascade CM10,boiler,81,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Cascade CM10,boiler,81,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Cascade CM10,boiler,81,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Cascade CM10,boiler,81,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Cascade CM10,boiler,81,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Cascade CM10,boiler,81,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Cascade CM10,boiler,81,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Cascade CM10,boiler,81,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Cascade CM10,boiler,81,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Cascade CM10,boiler,81,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Cascade CM10,boiler,81,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Cascade CM10,boiler,81,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Cascade CM10,boiler,81,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Cascade CM10,boiler,81,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Cascade CM10,boiler,81,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Cascade CM10,boiler,81,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Cascade CM10,boiler,81,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Cascade CM10,boiler,81,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Cascade CM10,boiler,81,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Cascade CM10,boiler,81,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Cascade CM10,boiler,81,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Cascade CM10,boiler,81,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Cascade CM10,boiler,81,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Cascade CM10,boiler,81,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Cascade CM10,boiler,81,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Logamax Plus GB022,boiler,84,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Logamax Plus GB022,boiler,84,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logamax Plus GB022,boiler,84,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logamax Plus GB022,boiler,84,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Logamax Plus GB022,boiler,84,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Logamax Plus GB022,boiler,84,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Logamax Plus GB022,boiler,84,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Logamax Plus GB022,boiler,84,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Logamax Plus GB022,boiler,84,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Logamax Plus GB022,boiler,84,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Logamax Plus GB022,boiler,84,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Logamax Plus GB022,boiler,84,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Logamax Plus GB022,boiler,84,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Logamax Plus GB022,boiler,84,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logamax Plus GB022,boiler,84,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logamax Plus GB022,boiler,84,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Logamax Plus GB022,boiler,84,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Logamax Plus GB022,boiler,84,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logamax Plus GB022,boiler,84,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logamax Plus GB022,boiler,84,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Logamax Plus GB022,boiler,84,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Logamax Plus GB022,boiler,84,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Logamax Plus GB022,boiler,84,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Logamax Plus GB022,boiler,84,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Logamax Plus GB022,boiler,84,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Logamax Plus GB022,boiler,84,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Logamax Plus GB022,boiler,84,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Logamax Plus GB022,boiler,84,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Logamax Plus GB022,boiler,84,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Logamax Plus GB022,boiler,84,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Logamax Plus GB022,boiler,84,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Logamax Plus GB022,boiler,84,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Logamax Plus GB022,boiler,84,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logamax Plus GB022,boiler,84,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Logamax Plus GB022,boiler,84,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logamax Plus GB022,boiler,84,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Logamax Plus GB022,boiler,84,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Logamax Plus GB022,boiler,84,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logamax Plus GB022,boiler,84,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logamax Plus GB022,boiler,84,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logamax Plus GB022,boiler,84,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Logamax Plus GB022,boiler,84,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logamax Plus GB022,boiler,84,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logamax Plus GB022,boiler,84,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Logamax Plus GB022,boiler,84,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Logamax Plus GB022,boiler,84,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Logamax Plus GB022,boiler,84,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Logamax Plus GB022,boiler,84,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Logamax Plus GB022,boiler,84,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Logamax Plus GB022,boiler,84,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Logamax Plus GB022,boiler,84,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Logamax Plus GB022,boiler,84,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logamax Plus GB022,boiler,84,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logamax Plus GB022,boiler,84,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Logamax Plus GB022,boiler,84,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Logamax Plus GB022,boiler,84,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Logamax Plus GB022,boiler,84,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Logamax Plus GB022,boiler,84,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Logamax Plus GB022,boiler,84,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Logamax Plus GB022,boiler,84,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Logamax Plus GB022,boiler,84,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Logamax Plus GB022,boiler,84,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Logamax Plus GB022,boiler,84,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Logamax Plus GB022,boiler,84,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Logamax Plus GB022,boiler,84,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Logamax Plus GB022,boiler,84,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Logamax Plus GB022,boiler,84,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Logamax Plus GB022,boiler,84,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Logamax Plus GB022,boiler,84,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Logamax Plus GB022,boiler,84,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Logamax Plus GB022,boiler,84,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Logamax Plus GB022,boiler,84,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Logamax Plus GB022,boiler,84,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Logamax Plus GB022,boiler,84,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Logamax Plus GB022,boiler,84,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Logamax Plus GB022,boiler,84,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Logamax Plus GB022,boiler,84,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Logamax Plus GB022,boiler,84,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Logamax Plus GB022,boiler,84,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Logamax Plus GB022,boiler,84,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Logamax Plus GB022,boiler,84,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Logamax Plus GB022,boiler,84,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Logamax Plus GB022,boiler,84,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Logamax Plus GB022,boiler,84,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Logamax Plus GB022,boiler,84,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Logamax Plus GB022,boiler,84,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Logamax Plus GB022,boiler,84,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Logamax Plus GB022,boiler,84,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Logamax Plus GB022,boiler,84,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Logamax Plus GB022,boiler,84,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Logamax Plus GB022,boiler,84,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Logamax Plus GB022,boiler,84,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Logamax Plus GB022,boiler,84,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Logamax Plus GB022,boiler,84,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Logamax Plus GB022,boiler,84,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Logamax Plus GB022,boiler,84,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Logamax Plus GB022,boiler,84,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Logamax Plus GB022,boiler,84,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Logamax Plus GB022,boiler,84,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Logamax Plus GB022,boiler,84,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Logamax Plus GB022,boiler,84,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Logamax Plus GB022,boiler,84,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Logamax Plus GB022,boiler,84,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Logamax Plus GB022,boiler,84,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Logamax Plus GB022,boiler,84,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Topline/GB162,boiler,115,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Topline/GB162,boiler,115,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Topline/GB162,boiler,115,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Topline/GB162,boiler,115,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Topline/GB162,boiler,115,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Topline/GB162,boiler,115,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Topline/GB162,boiler,115,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Topline/GB162,boiler,115,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Topline/GB162,boiler,115,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Topline/GB162,boiler,115,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Topline/GB162,boiler,115,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Topline/GB162,boiler,115,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Topline/GB162,boiler,115,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Topline/GB162,boiler,115,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Topline/GB162,boiler,115,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Topline/GB162,boiler,115,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Topline/GB162,boiler,115,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Topline/GB162,boiler,115,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Topline/GB162,boiler,115,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Topline/GB162,boiler,115,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Topline/GB162,boiler,115,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Topline/GB162,boiler,115,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Topline/GB162,boiler,115,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Topline/GB162,boiler,115,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Topline/GB162,boiler,115,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Topline/GB162,boiler,115,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Topline/GB162,boiler,115,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Topline/GB162,boiler,115,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Topline/GB162,boiler,115,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Topline/GB162,boiler,115,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Topline/GB162,boiler,115,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Topline/GB162,boiler,115,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Topline/GB162,boiler,115,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Topline/GB162,boiler,115,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Topline/GB162,boiler,115,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Topline/GB162,boiler,115,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Topline/GB162,boiler,115,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Topline/GB162,boiler,115,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Topline/GB162,boiler,115,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Topline/GB162,boiler,115,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Topline/GB162,boiler,115,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Topline/GB162,boiler,115,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Topline/GB162,boiler,115,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Topline/GB162,boiler,115,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Topline/GB162,boiler,115,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Topline/GB162,boiler,115,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Topline/GB162,boiler,115,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Topline/GB162,boiler,115,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Topline/GB162,boiler,115,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Topline/GB162,boiler,115,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Topline/GB162,boiler,115,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Topline/GB162,boiler,115,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Topline/GB162,boiler,115,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Topline/GB162,boiler,115,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Topline/GB162,boiler,115,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Topline/GB162,boiler,115,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Topline/GB162,boiler,115,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Topline/GB162,boiler,115,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Topline/GB162,boiler,115,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Topline/GB162,boiler,115,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Topline/GB162,boiler,115,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Topline/GB162,boiler,115,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Topline/GB162,boiler,115,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Topline/GB162,boiler,115,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Topline/GB162,boiler,115,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Topline/GB162,boiler,115,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Topline/GB162,boiler,115,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Topline/GB162,boiler,115,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Topline/GB162,boiler,115,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Topline/GB162,boiler,115,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Topline/GB162,boiler,115,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Topline/GB162,boiler,115,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Topline/GB162,boiler,115,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Topline/GB162,boiler,115,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Topline/GB162,boiler,115,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Topline/GB162,boiler,115,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Topline/GB162,boiler,115,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Topline/GB162,boiler,115,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Topline/GB162,boiler,115,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Topline/GB162,boiler,115,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Topline/GB162,boiler,115,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Topline/GB162,boiler,115,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Topline/GB162,boiler,115,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Topline/GB162,boiler,115,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Topline/GB162,boiler,115,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Topline/GB162,boiler,115,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Topline/GB162,boiler,115,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Topline/GB162,boiler,115,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Topline/GB162,boiler,115,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Topline/GB162,boiler,115,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Topline/GB162,boiler,115,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Topline/GB162,boiler,115,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Topline/GB162,boiler,115,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Topline/GB162,boiler,115,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Topline/GB162,boiler,115,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Topline/GB162,boiler,115,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Topline/GB162,boiler,115,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Topline/GB162,boiler,115,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Topline/GB162,boiler,115,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Topline/GB162,boiler,115,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Topline/GB162,boiler,115,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Topline/GB162,boiler,115,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Topline/GB162,boiler,115,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Topline/GB162,boiler,115,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Topline/GB162,boiler,115,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Cascade MCM10,boiler,121,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Cascade MCM10,boiler,121,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Cascade MCM10,boiler,121,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Cascade MCM10,boiler,121,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Cascade MCM10,boiler,121,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Cascade MCM10,boiler,121,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Cascade MCM10,boiler,121,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Cascade MCM10,boiler,121,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Cascade MCM10,boiler,121,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Cascade MCM10,boiler,121,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Cascade MCM10,boiler,121,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Cascade MCM10,boiler,121,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Cascade MCM10,boiler,121,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Cascade MCM10,boiler,121,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Cascade MCM10,boiler,121,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Cascade MCM10,boiler,121,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Cascade MCM10,boiler,121,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Cascade MCM10,boiler,121,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Cascade MCM10,boiler,121,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Cascade MCM10,boiler,121,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Cascade MCM10,boiler,121,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Cascade MCM10,boiler,121,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Cascade MCM10,boiler,121,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Cascade MCM10,boiler,121,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Cascade MCM10,boiler,121,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Cascade MCM10,boiler,121,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Cascade MCM10,boiler,121,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Cascade MCM10,boiler,121,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Cascade MCM10,boiler,121,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Cascade MCM10,boiler,121,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Cascade MCM10,boiler,121,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Cascade MCM10,boiler,121,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Cascade MCM10,boiler,121,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Cascade MCM10,boiler,121,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Cascade MCM10,boiler,121,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Cascade MCM10,boiler,121,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Cascade MCM10,boiler,121,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Cascade MCM10,boiler,121,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Cascade MCM10,boiler,121,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Cascade MCM10,boiler,121,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Cascade MCM10,boiler,121,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Cascade MCM10,boiler,121,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Cascade MCM10,boiler,121,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Cascade MCM10,boiler,121,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Cascade MCM10,boiler,121,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Cascade MCM10,boiler,121,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Cascade MCM10,boiler,121,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Cascade MCM10,boiler,121,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Cascade MCM10,boiler,121,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Cascade MCM10,boiler,121,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Cascade MCM10,boiler,121,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Cascade MCM10,boiler,121,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Cascade MCM10,boiler,121,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Cascade MCM10,boiler,121,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Cascade MCM10,boiler,121,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Cascade MCM10,boiler,121,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Cascade MCM10,boiler,121,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Cascade MCM10,boiler,121,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Cascade MCM10,boiler,121,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Cascade MCM10,boiler,121,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Cascade MCM10,boiler,121,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Cascade MCM10,boiler,121,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Cascade MCM10,boiler,121,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Cascade MCM10,boiler,121,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Cascade MCM10,boiler,121,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Cascade MCM10,boiler,121,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Cascade MCM10,boiler,121,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Cascade MCM10,boiler,121,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Cascade MCM10,boiler,121,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Cascade MCM10,boiler,121,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Cascade MCM10,boiler,121,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Cascade MCM10,boiler,121,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Cascade MCM10,boiler,121,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Cascade MCM10,boiler,121,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Cascade MCM10,boiler,121,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Cascade MCM10,boiler,121,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Cascade MCM10,boiler,121,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Cascade MCM10,boiler,121,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Cascade MCM10,boiler,121,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Cascade MCM10,boiler,121,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Cascade MCM10,boiler,121,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Cascade MCM10,boiler,121,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Cascade MCM10,boiler,121,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Cascade MCM10,boiler,121,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Cascade MCM10,boiler,121,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Cascade MCM10,boiler,121,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Cascade MCM10,boiler,121,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Cascade MCM10,boiler,121,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Cascade MCM10,boiler,121,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Cascade MCM10,boiler,121,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Cascade MCM10,boiler,121,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Cascade MCM10,boiler,121,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Cascade MCM10,boiler,121,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Cascade MCM10,boiler,121,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Cascade MCM10,boiler,121,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Cascade MCM10,boiler,121,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Cascade MCM10,boiler,121,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Cascade MCM10,boiler,121,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Cascade MCM10,boiler,121,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Cascade MCM10,boiler,121,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Cascade MCM10,boiler,121,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Cascade MCM10,boiler,121,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Cascade MCM10,boiler,121,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Cascade MCM10,boiler,121,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Cascade MCM10,boiler,121,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Proline,boiler,122,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Proline,boiler,122,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Proline,boiler,122,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Proline,boiler,122,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Proline,boiler,122,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Proline,boiler,122,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Proline,boiler,122,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Proline,boiler,122,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Proline,boiler,122,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Proline,boiler,122,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Proline,boiler,122,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Proline,boiler,122,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Proline,boiler,122,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Proline,boiler,122,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Proline,boiler,122,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Proline,boiler,122,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Proline,boiler,122,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Proline,boiler,122,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Proline,boiler,122,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Proline,boiler,122,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Proline,boiler,122,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Proline,boiler,122,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Proline,boiler,122,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Proline,boiler,122,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Proline,boiler,122,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Proline,boiler,122,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Proline,boiler,122,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Proline,boiler,122,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Proline,boiler,122,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Proline,boiler,122,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Proline,boiler,122,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Proline,boiler,122,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Proline,boiler,122,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Proline,boiler,122,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Proline,boiler,122,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Proline,boiler,122,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Proline,boiler,122,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Proline,boiler,122,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Proline,boiler,122,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Proline,boiler,122,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Proline,boiler,122,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Proline,boiler,122,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Proline,boiler,122,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Proline,boiler,122,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Proline,boiler,122,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Proline,boiler,122,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Proline,boiler,122,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Proline,boiler,122,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Proline,boiler,122,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Proline,boiler,122,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Proline,boiler,122,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Proline,boiler,122,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Proline,boiler,122,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Proline,boiler,122,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Proline,boiler,122,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Proline,boiler,122,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Proline,boiler,122,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Proline,boiler,122,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Proline,boiler,122,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Proline,boiler,122,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Proline,boiler,122,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Proline,boiler,122,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Proline,boiler,122,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Proline,boiler,122,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Proline,boiler,122,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Proline,boiler,122,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Proline,boiler,122,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Proline,boiler,122,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Proline,boiler,122,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Proline,boiler,122,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Proline,boiler,122,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Proline,boiler,122,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Proline,boiler,122,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Proline,boiler,122,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Proline,boiler,122,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Proline,boiler,122,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Proline,boiler,122,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Proline,boiler,122,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Proline,boiler,122,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Proline,boiler,122,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Proline,boiler,122,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Proline,boiler,122,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Proline,boiler,122,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Proline,boiler,122,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Proline,boiler,122,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Proline,boiler,122,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Proline,boiler,122,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Proline,boiler,122,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Proline,boiler,122,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Proline,boiler,122,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Proline,boiler,122,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Proline,boiler,122,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Proline,boiler,122,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Proline,boiler,122,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Proline,boiler,122,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Proline,boiler,122,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Proline,boiler,122,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Proline,boiler,122,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Proline,boiler,122,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Proline,boiler,122,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Proline,boiler,122,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Proline,boiler,122,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Proline,boiler,122,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Proline,boiler,122,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Proline,boiler,122,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww GB212,boiler,131,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset GB212,boiler,131,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff GB212,boiler,131,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive GB212,boiler,131,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive GB212,boiler,131,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp GB212,boiler,131,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod GB212,boiler,131,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp GB212,boiler,131,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp GB212,boiler,131,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp GB212,boiler,131,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp GB212,boiler,131,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress GB212,boiler,131,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp GB212,boiler,131,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp GB212,boiler,131,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp GB212,boiler,131,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas GB212,boiler,131,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 GB212,boiler,131,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr GB212,boiler,131,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork GB212,boiler,131,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork GB212,boiler,131,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat GB212,boiler,131,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower GB212,boiler,131,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower GB212,boiler,131,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod GB212,boiler,131,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow GB212,boiler,131,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock GB212,boiler,131,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston GB212,boiler,131,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff GB212,boiler,131,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston GB212,boiler,131,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff GB212,boiler,131,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon GB212,boiler,131,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase GB212,boiler,131,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend GB212,boiler,131,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp GB212,boiler,131,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode GB212,boiler,131,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp GB212,boiler,131,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated GB212,boiler,131,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp GB212,boiler,131,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump GB212,boiler,131,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax GB212,boiler,131,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin GB212,boiler,131,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode GB212,boiler,131,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay GB212,boiler,131,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp GB212,boiler,131,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow GB212,boiler,131,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow GB212,boiler,131,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow GB212,boiler,131,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts GB212,boiler,131,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin GB212,boiler,131,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin GB212,boiler,131,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin GB212,boiler,131,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts GB212,boiler,131,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime GB212,boiler,131,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode GB212,boiler,131,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode GB212,boiler,131,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber GB212,boiler,131,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage GB212,boiler,131,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance GB212,boiler,131,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime GB212,boiler,131,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate GB212,boiler,131,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops GB212,boiler,131,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp GB212,boiler,131,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated GB212,boiler,131,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp GB212,boiler,131,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp GB212,boiler,131,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow GB212,boiler,131,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus GB212,boiler,131,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff GB212,boiler,131,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle GB212,boiler,131,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp GB212,boiler,131,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype GB212,boiler,131,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort GB212,boiler,131,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 GB212,boiler,131,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset GB212,boiler,131,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization GB212,boiler,131,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower GB212,boiler,131,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp GB212,boiler,131,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump GB212,boiler,131,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype GB212,boiler,131,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston GB212,boiler,131,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff GB212,boiler,131,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp GB212,boiler,131,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode GB212,boiler,131,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc GB212,boiler,131,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp GB212,boiler,131,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 GB212,boiler,131,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow GB212,boiler,131,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 GB212,boiler,131,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 GB212,boiler,131,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated GB212,boiler,131,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime GB212,boiler,131,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting GB212,boiler,131,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging GB212,boiler,131,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging GB212,boiler,131,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok GB212,boiler,131,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive GB212,boiler,131,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve GB212,boiler,131,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower GB212,boiler,131,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp GB212,boiler,131,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp GB212,boiler,131,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts GB212,boiler,131,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm GB212,boiler,131,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower GB212,boiler,131,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal GB212,boiler,131,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat GB212,boiler,131,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww GC7000F,boiler,132,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset GC7000F,boiler,132,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff GC7000F,boiler,132,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive GC7000F,boiler,132,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive GC7000F,boiler,132,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp GC7000F,boiler,132,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod GC7000F,boiler,132,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp GC7000F,boiler,132,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp GC7000F,boiler,132,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp GC7000F,boiler,132,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp GC7000F,boiler,132,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress GC7000F,boiler,132,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp GC7000F,boiler,132,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp GC7000F,boiler,132,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp GC7000F,boiler,132,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas GC7000F,boiler,132,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 GC7000F,boiler,132,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr GC7000F,boiler,132,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork GC7000F,boiler,132,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork GC7000F,boiler,132,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat GC7000F,boiler,132,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower GC7000F,boiler,132,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower GC7000F,boiler,132,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod GC7000F,boiler,132,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow GC7000F,boiler,132,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock GC7000F,boiler,132,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston GC7000F,boiler,132,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff GC7000F,boiler,132,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston GC7000F,boiler,132,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff GC7000F,boiler,132,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon GC7000F,boiler,132,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase GC7000F,boiler,132,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend GC7000F,boiler,132,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp GC7000F,boiler,132,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode GC7000F,boiler,132,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp GC7000F,boiler,132,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated GC7000F,boiler,132,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp GC7000F,boiler,132,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump GC7000F,boiler,132,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax GC7000F,boiler,132,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin GC7000F,boiler,132,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode GC7000F,boiler,132,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay GC7000F,boiler,132,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp GC7000F,boiler,132,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow GC7000F,boiler,132,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow GC7000F,boiler,132,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow GC7000F,boiler,132,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts GC7000F,boiler,132,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin GC7000F,boiler,132,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin GC7000F,boiler,132,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin GC7000F,boiler,132,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts GC7000F,boiler,132,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime GC7000F,boiler,132,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode GC7000F,boiler,132,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode GC7000F,boiler,132,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber GC7000F,boiler,132,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage GC7000F,boiler,132,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance GC7000F,boiler,132,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime GC7000F,boiler,132,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate GC7000F,boiler,132,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops GC7000F,boiler,132,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp GC7000F,boiler,132,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated GC7000F,boiler,132,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp GC7000F,boiler,132,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp GC7000F,boiler,132,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow GC7000F,boiler,132,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus GC7000F,boiler,132,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff GC7000F,boiler,132,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle GC7000F,boiler,132,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp GC7000F,boiler,132,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype GC7000F,boiler,132,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort GC7000F,boiler,132,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 GC7000F,boiler,132,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset GC7000F,boiler,132,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization GC7000F,boiler,132,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower GC7000F,boiler,132,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp GC7000F,boiler,132,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump GC7000F,boiler,132,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype GC7000F,boiler,132,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston GC7000F,boiler,132,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff GC7000F,boiler,132,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp GC7000F,boiler,132,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode GC7000F,boiler,132,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc GC7000F,boiler,132,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp GC7000F,boiler,132,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 GC7000F,boiler,132,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow GC7000F,boiler,132,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 GC7000F,boiler,132,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 GC7000F,boiler,132,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated GC7000F,boiler,132,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime GC7000F,boiler,132,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting GC7000F,boiler,132,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging GC7000F,boiler,132,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging GC7000F,boiler,132,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok GC7000F,boiler,132,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive GC7000F,boiler,132,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve GC7000F,boiler,132,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower GC7000F,boiler,132,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp GC7000F,boiler,132,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp GC7000F,boiler,132,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts GC7000F,boiler,132,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm GC7000F,boiler,132,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower GC7000F,boiler,132,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal GC7000F,boiler,132,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat GC7000F,boiler,132,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Logano GB125/KB195i/Logamatic MC110,boiler,133,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logano GB125/KB195i/Logamatic MC110,boiler,133,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Logano GB125/KB195i/Logamatic MC110,boiler,133,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Logano GB125/KB195i/Logamatic MC110,boiler,133,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Logano GB125/KB195i/Logamatic MC110,boiler,133,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Logano GB125/KB195i/Logamatic MC110,boiler,133,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Logano GB125/KB195i/Logamatic MC110,boiler,133,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Logano GB125/KB195i/Logamatic MC110,boiler,133,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Logano GB125/KB195i/Logamatic MC110,boiler,133,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Logano GB125/KB195i/Logamatic MC110,boiler,133,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Logano GB125/KB195i/Logamatic MC110,boiler,133,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logano GB125/KB195i/Logamatic MC110,boiler,133,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logano GB125/KB195i/Logamatic MC110,boiler,133,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Logano GB125/KB195i/Logamatic MC110,boiler,133,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Logano GB125/KB195i/Logamatic MC110,boiler,133,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logano GB125/KB195i/Logamatic MC110,boiler,133,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logano GB125/KB195i/Logamatic MC110,boiler,133,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Logano GB125/KB195i/Logamatic MC110,boiler,133,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Logano GB125/KB195i/Logamatic MC110,boiler,133,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Logano GB125/KB195i/Logamatic MC110,boiler,133,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Logano GB125/KB195i/Logamatic MC110,boiler,133,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Logano GB125/KB195i/Logamatic MC110,boiler,133,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Logano GB125/KB195i/Logamatic MC110,boiler,133,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Logano GB125/KB195i/Logamatic MC110,boiler,133,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Logano GB125/KB195i/Logamatic MC110,boiler,133,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Logano GB125/KB195i/Logamatic MC110,boiler,133,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Logano GB125/KB195i/Logamatic MC110,boiler,133,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Logano GB125/KB195i/Logamatic MC110,boiler,133,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Logano GB125/KB195i/Logamatic MC110,boiler,133,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Logano GB125/KB195i/Logamatic MC110,boiler,133,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logano GB125/KB195i/Logamatic MC110,boiler,133,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Logano GB125/KB195i/Logamatic MC110,boiler,133,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logano GB125/KB195i/Logamatic MC110,boiler,133,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logano GB125/KB195i/Logamatic MC110,boiler,133,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Logano GB125/KB195i/Logamatic MC110,boiler,133,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Logano GB125/KB195i/Logamatic MC110,boiler,133,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Logano GB125/KB195i/Logamatic MC110,boiler,133,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Logano GB125/KB195i/Logamatic MC110,boiler,133,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Logano GB125/KB195i/Logamatic MC110,boiler,133,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Logano GB125/KB195i/Logamatic MC110,boiler,133,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Logano GB125/KB195i/Logamatic MC110,boiler,133,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Logano GB125/KB195i/Logamatic MC110,boiler,133,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logano GB125/KB195i/Logamatic MC110,boiler,133,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logano GB125/KB195i/Logamatic MC110,boiler,133,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Logano GB125/KB195i/Logamatic MC110,boiler,133,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Logano GB125/KB195i/Logamatic MC110,boiler,133,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Logano GB125/KB195i/Logamatic MC110,boiler,133,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Logano GB125/KB195i/Logamatic MC110,boiler,133,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Logano GB125/KB195i/Logamatic MC110,boiler,133,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Logano GB125/KB195i/Logamatic MC110,boiler,133,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Logano GB125/KB195i/Logamatic MC110,boiler,133,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Logano GB125/KB195i/Logamatic MC110,boiler,133,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Logano GB125/KB195i/Logamatic MC110,boiler,133,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Logano GB125/KB195i/Logamatic MC110,boiler,133,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Logano GB125/KB195i/Logamatic MC110,boiler,133,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Logano GB125/KB195i/Logamatic MC110,boiler,133,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Logano GB125/KB195i/Logamatic MC110,boiler,133,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Logano GB125/KB195i/Logamatic MC110,boiler,133,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Logano GB125/KB195i/Logamatic MC110,boiler,133,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Logano GB125/KB195i/Logamatic MC110,boiler,133,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Logano GB125/KB195i/Logamatic MC110,boiler,133,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Logano GB125/KB195i/Logamatic MC110,boiler,133,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Logano GB125/KB195i/Logamatic MC110,boiler,133,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Logano GB125/KB195i/Logamatic MC110,boiler,133,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Logano GB125/KB195i/Logamatic MC110,boiler,133,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Logano GB125/KB195i/Logamatic MC110,boiler,133,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Logano GB125/KB195i/Logamatic MC110,boiler,133,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Logano GB125/KB195i/Logamatic MC110,boiler,133,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Logano GB125/KB195i/Logamatic MC110,boiler,133,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Logano GB125/KB195i/Logamatic MC110,boiler,133,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Logano GB125/KB195i/Logamatic MC110,boiler,133,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Logano GB125/KB195i/Logamatic MC110,boiler,133,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Logano GB125/KB195i/Logamatic MC110,boiler,133,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Logano GB125/KB195i/Logamatic MC110,boiler,133,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Logano GB125/KB195i/Logamatic MC110,boiler,133,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Logano GB125/KB195i/Logamatic MC110,boiler,133,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Logano GB125/KB195i/Logamatic MC110,boiler,133,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Logano GB125/KB195i/Logamatic MC110,boiler,133,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Logano GB125/KB195i/Logamatic MC110,boiler,133,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Logano GB125/KB195i/Logamatic MC110,boiler,133,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Logano GB125/KB195i/Logamatic MC110,boiler,133,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Logano GB125/KB195i/Logamatic MC110,boiler,133,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Logano GB125/KB195i/Logamatic MC110,boiler,133,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Greenstar 30Ri Compact,boiler,154,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Greenstar 30Ri Compact,boiler,154,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Greenstar 30Ri Compact,boiler,154,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Greenstar 30Ri Compact,boiler,154,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Greenstar 30Ri Compact,boiler,154,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Greenstar 30Ri Compact,boiler,154,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Greenstar 30Ri Compact,boiler,154,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Greenstar 30Ri Compact,boiler,154,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Greenstar 30Ri Compact,boiler,154,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Greenstar 30Ri Compact,boiler,154,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Greenstar 30Ri Compact,boiler,154,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Greenstar 30Ri Compact,boiler,154,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Greenstar 30Ri Compact,boiler,154,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Greenstar 30Ri Compact,boiler,154,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Greenstar 30Ri Compact,boiler,154,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Greenstar 30Ri Compact,boiler,154,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Greenstar 30Ri Compact,boiler,154,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Greenstar 30Ri Compact,boiler,154,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Greenstar 30Ri Compact,boiler,154,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Greenstar 30Ri Compact,boiler,154,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Greenstar 30Ri Compact,boiler,154,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Greenstar 30Ri Compact,boiler,154,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Greenstar 30Ri Compact,boiler,154,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Greenstar 30Ri Compact,boiler,154,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Greenstar 30Ri Compact,boiler,154,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Greenstar 30Ri Compact,boiler,154,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Greenstar 30Ri Compact,boiler,154,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Greenstar 30Ri Compact,boiler,154,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Greenstar 30Ri Compact,boiler,154,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Greenstar 30Ri Compact,boiler,154,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Greenstar 30Ri Compact,boiler,154,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Greenstar 30Ri Compact,boiler,154,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Greenstar 30Ri Compact,boiler,154,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Greenstar 30Ri Compact,boiler,154,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Greenstar 30Ri Compact,boiler,154,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Greenstar 30Ri Compact,boiler,154,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Greenstar 30Ri Compact,boiler,154,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Greenstar 30Ri Compact,boiler,154,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Greenstar 30Ri Compact,boiler,154,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Greenstar 30Ri Compact,boiler,154,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Greenstar 30Ri Compact,boiler,154,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Greenstar 30Ri Compact,boiler,154,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Greenstar 30Ri Compact,boiler,154,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Greenstar 30Ri Compact,boiler,154,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Greenstar 30Ri Compact,boiler,154,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Greenstar 30Ri Compact,boiler,154,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Greenstar 30Ri Compact,boiler,154,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Greenstar 30Ri Compact,boiler,154,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Greenstar 30Ri Compact,boiler,154,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Greenstar 30Ri Compact,boiler,154,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Greenstar 30Ri Compact,boiler,154,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Greenstar 30Ri Compact,boiler,154,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Greenstar 30Ri Compact,boiler,154,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Greenstar 30Ri Compact,boiler,154,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Greenstar 30Ri Compact,boiler,154,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Greenstar 30Ri Compact,boiler,154,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Greenstar 30Ri Compact,boiler,154,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Greenstar 30Ri Compact,boiler,154,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Greenstar 30Ri Compact,boiler,154,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Greenstar 30Ri Compact,boiler,154,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Greenstar 30Ri Compact,boiler,154,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Greenstar 30Ri Compact,boiler,154,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Greenstar 30Ri Compact,boiler,154,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Greenstar 30Ri Compact,boiler,154,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Greenstar 30Ri Compact,boiler,154,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Greenstar 30Ri Compact,boiler,154,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Greenstar 30Ri Compact,boiler,154,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Greenstar 30Ri Compact,boiler,154,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Greenstar 30Ri Compact,boiler,154,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Greenstar 30Ri Compact,boiler,154,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Greenstar 30Ri Compact,boiler,154,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Greenstar 30Ri Compact,boiler,154,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Greenstar 30Ri Compact,boiler,154,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Greenstar 30Ri Compact,boiler,154,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Greenstar 30Ri Compact,boiler,154,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Greenstar 30Ri Compact,boiler,154,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Greenstar 30Ri Compact,boiler,154,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Greenstar 30Ri Compact,boiler,154,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Greenstar 30Ri Compact,boiler,154,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Greenstar 30Ri Compact,boiler,154,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Greenstar 30Ri Compact,boiler,154,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Greenstar 30Ri Compact,boiler,154,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Greenstar 30Ri Compact,boiler,154,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Greenstar 30Ri Compact,boiler,154,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Greenstar 30Ri Compact,boiler,154,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Greenstar 30Ri Compact,boiler,154,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Greenstar 30Ri Compact,boiler,154,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Greenstar 30Ri Compact,boiler,154,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Greenstar 30Ri Compact,boiler,154,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Greenstar 30Ri Compact,boiler,154,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Greenstar 30Ri Compact,boiler,154,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Greenstar 30Ri Compact,boiler,154,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Greenstar 30Ri Compact,boiler,154,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Greenstar 30Ri Compact,boiler,154,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Greenstar 30Ri Compact,boiler,154,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Greenstar 30Ri Compact,boiler,154,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Greenstar 30Ri Compact,boiler,154,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Greenstar 30Ri Compact,boiler,154,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Greenstar 30Ri Compact,boiler,154,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Greenstar 30Ri Compact,boiler,154,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Greenstar 30Ri Compact,boiler,154,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Greenstar 30Ri Compact,boiler,154,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Greenstar 30Ri Compact,boiler,154,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Greenstar 30Ri Compact,boiler,154,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Greenstar 30Ri Compact,boiler,154,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Cerapur Aero,boiler,167,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Cerapur Aero,boiler,167,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Cerapur Aero,boiler,167,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Cerapur Aero,boiler,167,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Cerapur Aero,boiler,167,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Cerapur Aero,boiler,167,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Cerapur Aero,boiler,167,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Cerapur Aero,boiler,167,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Cerapur Aero,boiler,167,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Cerapur Aero,boiler,167,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Cerapur Aero,boiler,167,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Cerapur Aero,boiler,167,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Cerapur Aero,boiler,167,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Cerapur Aero,boiler,167,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Cerapur Aero,boiler,167,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Cerapur Aero,boiler,167,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Cerapur Aero,boiler,167,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Cerapur Aero,boiler,167,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Cerapur Aero,boiler,167,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Cerapur Aero,boiler,167,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Cerapur Aero,boiler,167,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Cerapur Aero,boiler,167,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Cerapur Aero,boiler,167,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Cerapur Aero,boiler,167,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Cerapur Aero,boiler,167,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Cerapur Aero,boiler,167,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Cerapur Aero,boiler,167,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Cerapur Aero,boiler,167,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Cerapur Aero,boiler,167,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Cerapur Aero,boiler,167,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Cerapur Aero,boiler,167,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Cerapur Aero,boiler,167,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Cerapur Aero,boiler,167,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Cerapur Aero,boiler,167,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Cerapur Aero,boiler,167,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Cerapur Aero,boiler,167,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Cerapur Aero,boiler,167,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Cerapur Aero,boiler,167,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Cerapur Aero,boiler,167,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Cerapur Aero,boiler,167,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Cerapur Aero,boiler,167,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Cerapur Aero,boiler,167,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Cerapur Aero,boiler,167,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Cerapur Aero,boiler,167,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Cerapur Aero,boiler,167,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Cerapur Aero,boiler,167,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Cerapur Aero,boiler,167,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Cerapur Aero,boiler,167,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Cerapur Aero,boiler,167,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Cerapur Aero,boiler,167,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Cerapur Aero,boiler,167,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Cerapur Aero,boiler,167,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Cerapur Aero,boiler,167,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Cerapur Aero,boiler,167,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Cerapur Aero,boiler,167,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Cerapur Aero,boiler,167,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Cerapur Aero,boiler,167,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Cerapur Aero,boiler,167,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Cerapur Aero,boiler,167,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Cerapur Aero,boiler,167,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Cerapur Aero,boiler,167,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Cerapur Aero,boiler,167,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Cerapur Aero,boiler,167,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Cerapur Aero,boiler,167,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Cerapur Aero,boiler,167,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Cerapur Aero,boiler,167,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Cerapur Aero,boiler,167,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Cerapur Aero,boiler,167,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Cerapur Aero,boiler,167,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Cerapur Aero,boiler,167,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Cerapur Aero,boiler,167,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Cerapur Aero,boiler,167,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Cerapur Aero,boiler,167,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Cerapur Aero,boiler,167,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Cerapur Aero,boiler,167,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Cerapur Aero,boiler,167,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Cerapur Aero,boiler,167,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Cerapur Aero,boiler,167,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Cerapur Aero,boiler,167,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Cerapur Aero,boiler,167,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Cerapur Aero,boiler,167,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Cerapur Aero,boiler,167,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Cerapur Aero,boiler,167,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Cerapur Aero,boiler,167,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Cerapur Aero,boiler,167,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Cerapur Aero,boiler,167,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Cerapur Aero,boiler,167,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Cerapur Aero,boiler,167,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Cerapur Aero,boiler,167,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Cerapur Aero,boiler,167,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Cerapur Aero,boiler,167,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Cerapur Aero,boiler,167,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Cerapur Aero,boiler,167,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Cerapur Aero,boiler,167,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Cerapur Aero,boiler,167,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Cerapur Aero,boiler,167,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Cerapur Aero,boiler,167,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Cerapur Aero,boiler,167,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Cerapur Aero,boiler,167,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Cerapur Aero,boiler,167,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Cerapur Aero,boiler,167,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Cerapur Aero,boiler,167,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Cerapur Aero,boiler,167,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Cerapur Aero,boiler,167,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Cerapur Aero,boiler,167,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Hybrid Heatpump,boiler,168,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Hybrid Heatpump,boiler,168,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Hybrid Heatpump,boiler,168,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Hybrid Heatpump,boiler,168,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Hybrid Heatpump,boiler,168,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Hybrid Heatpump,boiler,168,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Hybrid Heatpump,boiler,168,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Hybrid Heatpump,boiler,168,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Hybrid Heatpump,boiler,168,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Hybrid Heatpump,boiler,168,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Hybrid Heatpump,boiler,168,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Hybrid Heatpump,boiler,168,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Hybrid Heatpump,boiler,168,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Hybrid Heatpump,boiler,168,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Hybrid Heatpump,boiler,168,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Hybrid Heatpump,boiler,168,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Hybrid Heatpump,boiler,168,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Hybrid Heatpump,boiler,168,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Hybrid Heatpump,boiler,168,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Hybrid Heatpump,boiler,168,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Hybrid Heatpump,boiler,168,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Hybrid Heatpump,boiler,168,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Hybrid Heatpump,boiler,168,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Hybrid Heatpump,boiler,168,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Hybrid Heatpump,boiler,168,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Hybrid Heatpump,boiler,168,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Hybrid Heatpump,boiler,168,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Hybrid Heatpump,boiler,168,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Hybrid Heatpump,boiler,168,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Hybrid Heatpump,boiler,168,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Hybrid Heatpump,boiler,168,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Hybrid Heatpump,boiler,168,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Hybrid Heatpump,boiler,168,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Hybrid Heatpump,boiler,168,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Hybrid Heatpump,boiler,168,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Hybrid Heatpump,boiler,168,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Hybrid Heatpump,boiler,168,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Hybrid Heatpump,boiler,168,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Hybrid Heatpump,boiler,168,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Hybrid Heatpump,boiler,168,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Hybrid Heatpump,boiler,168,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Hybrid Heatpump,boiler,168,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Hybrid Heatpump,boiler,168,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Hybrid Heatpump,boiler,168,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Hybrid Heatpump,boiler,168,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Hybrid Heatpump,boiler,168,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Hybrid Heatpump,boiler,168,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Hybrid Heatpump,boiler,168,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Hybrid Heatpump,boiler,168,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Hybrid Heatpump,boiler,168,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Hybrid Heatpump,boiler,168,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Hybrid Heatpump,boiler,168,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Hybrid Heatpump,boiler,168,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Hybrid Heatpump,boiler,168,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Hybrid Heatpump,boiler,168,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Hybrid Heatpump,boiler,168,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Hybrid Heatpump,boiler,168,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Hybrid Heatpump,boiler,168,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Hybrid Heatpump,boiler,168,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Hybrid Heatpump,boiler,168,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Hybrid Heatpump,boiler,168,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Hybrid Heatpump,boiler,168,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Hybrid Heatpump,boiler,168,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Hybrid Heatpump,boiler,168,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Hybrid Heatpump,boiler,168,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Hybrid Heatpump,boiler,168,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Hybrid Heatpump,boiler,168,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Hybrid Heatpump,boiler,168,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Hybrid Heatpump,boiler,168,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Hybrid Heatpump,boiler,168,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Hybrid Heatpump,boiler,168,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Hybrid Heatpump,boiler,168,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Hybrid Heatpump,boiler,168,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Hybrid Heatpump,boiler,168,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Hybrid Heatpump,boiler,168,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Hybrid Heatpump,boiler,168,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Hybrid Heatpump,boiler,168,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Hybrid Heatpump,boiler,168,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Hybrid Heatpump,boiler,168,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Hybrid Heatpump,boiler,168,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Hybrid Heatpump,boiler,168,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Hybrid Heatpump,boiler,168,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Hybrid Heatpump,boiler,168,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Hybrid Heatpump,boiler,168,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Hybrid Heatpump,boiler,168,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Hybrid Heatpump,boiler,168,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Hybrid Heatpump,boiler,168,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Hybrid Heatpump,boiler,168,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Hybrid Heatpump,boiler,168,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Hybrid Heatpump,boiler,168,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Hybrid Heatpump,boiler,168,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Hybrid Heatpump,boiler,168,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Hybrid Heatpump,boiler,168,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Hybrid Heatpump,boiler,168,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Hybrid Heatpump,boiler,168,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Hybrid Heatpump,boiler,168,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Hybrid Heatpump,boiler,168,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Hybrid Heatpump,boiler,168,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Hybrid Heatpump,boiler,168,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Hybrid Heatpump,boiler,168,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Hybrid Heatpump,boiler,168,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Hybrid Heatpump,boiler,168,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Hybrid Heatpump,boiler,168,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Hybrid Heatpump,boiler,168,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Hybrid Heatpump,boiler,168,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Logano GB212,boiler,170,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Logano GB212,boiler,170,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logano GB212,boiler,170,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logano GB212,boiler,170,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Logano GB212,boiler,170,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Logano GB212,boiler,170,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Logano GB212,boiler,170,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Logano GB212,boiler,170,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Logano GB212,boiler,170,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Logano GB212,boiler,170,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Logano GB212,boiler,170,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Logano GB212,boiler,170,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Logano GB212,boiler,170,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Logano GB212,boiler,170,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logano GB212,boiler,170,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logano GB212,boiler,170,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Logano GB212,boiler,170,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Logano GB212,boiler,170,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logano GB212,boiler,170,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logano GB212,boiler,170,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Logano GB212,boiler,170,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Logano GB212,boiler,170,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Logano GB212,boiler,170,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Logano GB212,boiler,170,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Logano GB212,boiler,170,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Logano GB212,boiler,170,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Logano GB212,boiler,170,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Logano GB212,boiler,170,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Logano GB212,boiler,170,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Logano GB212,boiler,170,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Logano GB212,boiler,170,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Logano GB212,boiler,170,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Logano GB212,boiler,170,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logano GB212,boiler,170,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Logano GB212,boiler,170,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logano GB212,boiler,170,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Logano GB212,boiler,170,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Logano GB212,boiler,170,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logano GB212,boiler,170,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logano GB212,boiler,170,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logano GB212,boiler,170,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Logano GB212,boiler,170,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logano GB212,boiler,170,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logano GB212,boiler,170,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Logano GB212,boiler,170,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Logano GB212,boiler,170,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Logano GB212,boiler,170,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Logano GB212,boiler,170,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Logano GB212,boiler,170,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Logano GB212,boiler,170,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Logano GB212,boiler,170,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Logano GB212,boiler,170,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logano GB212,boiler,170,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logano GB212,boiler,170,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Logano GB212,boiler,170,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Logano GB212,boiler,170,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Logano GB212,boiler,170,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Logano GB212,boiler,170,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Logano GB212,boiler,170,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Logano GB212,boiler,170,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Logano GB212,boiler,170,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Logano GB212,boiler,170,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Logano GB212,boiler,170,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Logano GB212,boiler,170,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Logano GB212,boiler,170,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Logano GB212,boiler,170,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Logano GB212,boiler,170,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Logano GB212,boiler,170,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Logano GB212,boiler,170,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Logano GB212,boiler,170,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Logano GB212,boiler,170,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Logano GB212,boiler,170,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Logano GB212,boiler,170,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Logano GB212,boiler,170,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Logano GB212,boiler,170,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Logano GB212,boiler,170,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Logano GB212,boiler,170,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Logano GB212,boiler,170,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Logano GB212,boiler,170,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Logano GB212,boiler,170,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Logano GB212,boiler,170,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Logano GB212,boiler,170,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Logano GB212,boiler,170,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Logano GB212,boiler,170,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Logano GB212,boiler,170,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Logano GB212,boiler,170,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Logano GB212,boiler,170,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Logano GB212,boiler,170,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Logano GB212,boiler,170,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Logano GB212,boiler,170,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Logano GB212,boiler,170,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Logano GB212,boiler,170,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Logano GB212,boiler,170,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Logano GB212,boiler,170,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Logano GB212,boiler,170,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Logano GB212,boiler,170,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Logano GB212,boiler,170,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Logano GB212,boiler,170,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Logano GB212,boiler,170,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Logano GB212,boiler,170,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Logano GB212,boiler,170,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Logano GB212,boiler,170,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Logano GB212,boiler,170,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Logano GB212,boiler,170,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Logano GB212,boiler,170,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgww,energy,ulong (>=0<=167772),kWh,false,sensor.boiler_energy,sensor.boiler_nrgww Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgheat,energy heating,ulong (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metertotal,meter total,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metercomp,meter compressor,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metereheat,meter e-heater,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,meterheat,meter heating,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,meterww,meter,ulong (>=0<=167772),kWh,false,sensor.boiler_meter,sensor.boiler_meterww Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompww,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor,sensor.boiler_uptimecompww Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,totalcompstarts,total compressor control starts,ulong (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingstarts,heating control starts,ulong (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,coolingstarts,cooling control starts,ulong (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwstarts2,control starts2,ulong (>=0<=16777213), ,false,sensor.boiler_control_starts2,sensor.boiler_wwstarts2 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,poolstarts,pool control starts,ulong (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconstotal,total energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscomptotal,total energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompheating,energy consumption compressor heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompww,energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor,sensor.boiler_nrgconscompww Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompcooling,energy consumption compressor cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscomppool,energy consumption compressor pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconstotal,total aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconsww,aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconsww Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconspool,aux elec. heater energy consumption pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsupptotal,total energy supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppheating,total energy supplied heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppww,total energy warm supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_warm_supplied,sensor.boiler_nrgsuppww Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppcooling,total energy supplied cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsupppool,total energy supplied pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppower,compressor power output,uint (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpmaxpower,compressor max power,uint (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpsetdiffpress,set differental pressure,uint (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpbrinepumpspd,brine pump speed,uint (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcompspd,compressor speed,uint (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcircspd,circulation pump speed,uint (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpbrinein,brine in/evaporator,short (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpbrineout,brine out/condenser,short (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptc0,heat carrier return (TC0),short (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptc1,heat carrier forward (TC1),short (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptc3,condenser temperature (TC3),short (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr1,compressor temperature (TR1),short (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr3,refrigerant temperature liquid side (condenser output) (TR3),short (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr4,evaporator inlet temperature (TR4),short (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr5,compressor inlet temperature (TR5),short (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr6,compressor outlet temperature (TR6),short (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptr7,refrigerant temperature gas side (condenser input) (TR7),short (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptl2,air inlet temperature (TL2),short (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppl1,low pressure side temperature (PL1),short (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpph1,high pressure side temperature (PH1),short (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpta4,drain pan temp (TA4),short (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptw1,reservoir temp (TW1),short (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,poolsettemp,pool set temperature,uint (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheatdhw,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit,select.boiler_maxheatdhw Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheaterstatus,aux heater status,boolean, ,false,binary_sensor.boiler_aux_heater_status,binary_sensor.boiler_auxheaterstatus Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheaterdelay,aux heater on delay,ushort (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxmaxlimit,aux heater max limit,uint (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxlimitstart,aux heater limit start,uint (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hphystheat,on/off hyst heat,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hphystcool,on/off hyst cool,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hphystpool,on/off hyst pool,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,silentfrom,silent mode from,uint (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,silentto,silent mode to,uint (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,mintempsilent,min outside temp for silent mode,int (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tempparmode,outside temp parallel mode,int (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheatmix,aux heater mixing valve,int (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tempdiffheat,temp diff TC3/TC0 heat,uint (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tempdiffcool,temp diff TC3/TC0 cool,uint (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,primepumpmod,primary heatpump modulation,uint (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwalternatingop,alternating operation,boolean, ,true,switch.boiler_alternating_operation,switch.boiler_wwalternatingop Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwaltopprioheat,prioritise heating during dhw,uint (>=20<=120),minutes,true,number.boiler_prioritise_heating_during_dhw,number.boiler_wwaltopprioheat Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwaltopprioww,prioritise dhw during heating,uint (>=30<=120),minutes,true,number.boiler_prioritise_dhw_during_heating,number.boiler_wwaltopprioww Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcomfoff,comfort switch off,uint (>=15<=65),C,true,number.boiler_comfort_switch_off,number.boiler_wwcomfoff Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwecooff,eco switch off,uint (>=15<=65),C,true,number.boiler_eco_switch_off,number.boiler_wwecooff Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwecoplusoff,eco+ switch off,uint (>=48<=63),C,true,number.boiler_eco+_switch_off,number.boiler_wwecoplusoff Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcomfdiff,comfort diff,uint (>=6<=12),K,true,number.boiler_comfort_diff,number.boiler_wwcomfdiff Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwecodiff,eco diff,uint (>=6<=12),K,true,number.boiler_eco_diff,number.boiler_wwecodiff Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwecoplusdiff,eco+ diff,uint (>=6<=12),K,true,number.boiler_eco+_diff,number.boiler_wwecoplusdiff Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcomfstop,comfort stop temp,uint (>=0<=254),C,true,number.boiler_comfort_stop_temp,number.boiler_wwcomfstop Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwecostop,eco stop temp,uint (>=0<=254),C,true,number.boiler_eco_stop_temp,number.boiler_wwecostop Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwecoplusstop,eco+ stop temp,uint (>=0<=254),C,true,number.boiler_eco+_stop_temp,number.boiler_wwecoplusstop Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcircpumpww,circulation pump available during dhw,boolean, ,true,switch.boiler_circulation_pump_available_during_dhw,switch.boiler_hpcircpumpww Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Geo 5xx,boiler,173,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Geo 5xx,boiler,173,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Geo 5xx,boiler,173,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Geo 5xx,boiler,173,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Geo 5xx,boiler,173,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Geo 5xx,boiler,173,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Geo 5xx,boiler,173,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Geo 5xx,boiler,173,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Geo 5xx,boiler,173,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Geo 5xx,boiler,173,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Geo 5xx,boiler,173,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Geo 5xx,boiler,173,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Geo 5xx,boiler,173,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Geo 5xx,boiler,173,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Geo 5xx,boiler,173,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Geo 5xx,boiler,173,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Geo 5xx,boiler,173,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Geo 5xx,boiler,173,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Geo 5xx,boiler,173,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Geo 5xx,boiler,173,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Geo 5xx,boiler,173,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Geo 5xx,boiler,173,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Geo 5xx,boiler,173,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Geo 5xx,boiler,173,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Geo 5xx,boiler,173,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Geo 5xx,boiler,173,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Geo 5xx,boiler,173,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Geo 5xx,boiler,173,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Geo 5xx,boiler,173,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Geo 5xx,boiler,173,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Geo 5xx,boiler,173,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Geo 5xx,boiler,173,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Geo 5xx,boiler,173,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Geo 5xx,boiler,173,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Geo 5xx,boiler,173,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Geo 5xx,boiler,173,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Geo 5xx,boiler,173,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Geo 5xx,boiler,173,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Geo 5xx,boiler,173,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Geo 5xx,boiler,173,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Geo 5xx,boiler,173,nrgww,energy,ulong (>=0<=167772),kWh,false,sensor.boiler_energy,sensor.boiler_nrgww Geo 5xx,boiler,173,nrgheat,energy heating,ulong (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat Geo 5xx,boiler,173,metertotal,meter total,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal Geo 5xx,boiler,173,metercomp,meter compressor,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp Geo 5xx,boiler,173,metereheat,meter e-heater,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat Geo 5xx,boiler,173,meterheat,meter heating,ulong (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat Geo 5xx,boiler,173,meterww,meter,ulong (>=0<=167772),kWh,false,sensor.boiler_meter,sensor.boiler_meterww Geo 5xx,boiler,173,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal Geo 5xx,boiler,173,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol Geo 5xx,boiler,173,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating Geo 5xx,boiler,173,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling Geo 5xx,boiler,173,uptimecompww,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor,sensor.boiler_uptimecompww Geo 5xx,boiler,173,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool Geo 5xx,boiler,173,totalcompstarts,total compressor control starts,ulong (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts Geo 5xx,boiler,173,heatingstarts,heating control starts,ulong (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts Geo 5xx,boiler,173,coolingstarts,cooling control starts,ulong (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts Geo 5xx,boiler,173,wwstarts2,control starts2,ulong (>=0<=16777213), ,false,sensor.boiler_control_starts2,sensor.boiler_wwstarts2 Geo 5xx,boiler,173,poolstarts,pool control starts,ulong (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts Geo 5xx,boiler,173,nrgconstotal,total energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal Geo 5xx,boiler,173,nrgconscomptotal,total energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal Geo 5xx,boiler,173,nrgconscompheating,energy consumption compressor heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating Geo 5xx,boiler,173,nrgconscompww,energy consumption compressor,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor,sensor.boiler_nrgconscompww Geo 5xx,boiler,173,nrgconscompcooling,energy consumption compressor cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling Geo 5xx,boiler,173,nrgconscomppool,energy consumption compressor pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool Geo 5xx,boiler,173,auxelecheatnrgconstotal,total aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal Geo 5xx,boiler,173,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating Geo 5xx,boiler,173,auxelecheatnrgconsww,aux elec. heater energy consumption,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconsww Geo 5xx,boiler,173,auxelecheatnrgconspool,aux elec. heater energy consumption pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool Geo 5xx,boiler,173,nrgsupptotal,total energy supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal Geo 5xx,boiler,173,nrgsuppheating,total energy supplied heating,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating Geo 5xx,boiler,173,nrgsuppww,total energy warm supplied,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_warm_supplied,sensor.boiler_nrgsuppww Geo 5xx,boiler,173,nrgsuppcooling,total energy supplied cooling,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling Geo 5xx,boiler,173,nrgsupppool,total energy supplied pool,ulong (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool Geo 5xx,boiler,173,hppower,compressor power output,uint (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower Geo 5xx,boiler,173,hpmaxpower,compressor max power,uint (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower Geo 5xx,boiler,173,hpsetdiffpress,set differental pressure,uint (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress Geo 5xx,boiler,173,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon Geo 5xx,boiler,173,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity Geo 5xx,boiler,173,hpbrinepumpspd,brine pump speed,uint (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd Geo 5xx,boiler,173,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve Geo 5xx,boiler,173,hpcompspd,compressor speed,uint (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd Geo 5xx,boiler,173,hpcircspd,circulation pump speed,uint (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd Geo 5xx,boiler,173,hpbrinein,brine in/evaporator,short (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein Geo 5xx,boiler,173,hpbrineout,brine out/condenser,short (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout Geo 5xx,boiler,173,hptc0,heat carrier return (TC0),short (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0 Geo 5xx,boiler,173,hptc1,heat carrier forward (TC1),short (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1 Geo 5xx,boiler,173,hptc3,condenser temperature (TC3),short (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3 Geo 5xx,boiler,173,hptr1,compressor temperature (TR1),short (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1 Geo 5xx,boiler,173,hptr3,refrigerant temperature liquid side (condenser output) (TR3),short (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3 Geo 5xx,boiler,173,hptr4,evaporator inlet temperature (TR4),short (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4 Geo 5xx,boiler,173,hptr5,compressor inlet temperature (TR5),short (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5 Geo 5xx,boiler,173,hptr6,compressor outlet temperature (TR6),short (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6 Geo 5xx,boiler,173,hptr7,refrigerant temperature gas side (condenser input) (TR7),short (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7 Geo 5xx,boiler,173,hptl2,air inlet temperature (TL2),short (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2 Geo 5xx,boiler,173,hppl1,low pressure side temperature (PL1),short (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1 Geo 5xx,boiler,173,hpph1,high pressure side temperature (PH1),short (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1 Geo 5xx,boiler,173,hpta4,drain pan temp (TA4),short (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4 Geo 5xx,boiler,173,hptw1,reservoir temp (TW1),short (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1 Geo 5xx,boiler,173,poolsettemp,pool set temperature,uint (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp Geo 5xx,boiler,173,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way Geo 5xx,boiler,173,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt Geo 5xx,boiler,173,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt Geo 5xx,boiler,173,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt Geo 5xx,boiler,173,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt Geo 5xx,boiler,173,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp Geo 5xx,boiler,173,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat Geo 5xx,boiler,173,maxheatdhw,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit,select.boiler_maxheatdhw Geo 5xx,boiler,173,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost Geo 5xx,boiler,173,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling Geo 5xx,boiler,173,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly Geo 5xx,boiler,173,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff Geo 5xx,boiler,173,auxheaterstatus,aux heater status,boolean, ,false,binary_sensor.boiler_aux_heater_status,binary_sensor.boiler_auxheaterstatus Geo 5xx,boiler,173,auxheaterdelay,aux heater on delay,ushort (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay Geo 5xx,boiler,173,auxmaxlimit,aux heater max limit,uint (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit Geo 5xx,boiler,173,auxlimitstart,aux heater limit start,uint (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart Geo 5xx,boiler,173,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode Geo 5xx,boiler,173,hphystheat,on/off hyst heat,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat Geo 5xx,boiler,173,hphystcool,on/off hyst cool,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool Geo 5xx,boiler,173,hphystpool,on/off hyst pool,ushort (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool Geo 5xx,boiler,173,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode Geo 5xx,boiler,173,silentfrom,silent mode from,uint (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom Geo 5xx,boiler,173,silentto,silent mode to,uint (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto Geo 5xx,boiler,173,mintempsilent,min outside temp for silent mode,int (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent Geo 5xx,boiler,173,tempparmode,outside temp parallel mode,int (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode Geo 5xx,boiler,173,auxheatmix,aux heater mixing valve,int (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix Geo 5xx,boiler,173,tempdiffheat,temp diff TC3/TC0 heat,uint (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat Geo 5xx,boiler,173,tempdiffcool,temp diff TC3/TC0 cool,uint (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool Geo 5xx,boiler,173,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling Geo 5xx,boiler,173,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable Geo 5xx,boiler,173,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve Geo 5xx,boiler,173,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump Geo 5xx,boiler,173,primepumpmod,primary heatpump modulation,uint (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod Geo 5xx,boiler,173,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way Geo 5xx,boiler,173,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1 Geo 5xx,boiler,173,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2 Geo 5xx,boiler,173,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3 Geo 5xx,boiler,173,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0 Geo 5xx,boiler,173,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode Geo 5xx,boiler,173,wwalternatingop,alternating operation,boolean, ,true,switch.boiler_alternating_operation,switch.boiler_wwalternatingop Geo 5xx,boiler,173,wwaltopprioheat,prioritise heating during dhw,uint (>=20<=120),minutes,true,number.boiler_prioritise_heating_during_dhw,number.boiler_wwaltopprioheat Geo 5xx,boiler,173,wwaltopprioww,prioritise dhw during heating,uint (>=30<=120),minutes,true,number.boiler_prioritise_dhw_during_heating,number.boiler_wwaltopprioww Geo 5xx,boiler,173,wwcomfoff,comfort switch off,uint (>=15<=65),C,true,number.boiler_comfort_switch_off,number.boiler_wwcomfoff Geo 5xx,boiler,173,wwecooff,eco switch off,uint (>=15<=65),C,true,number.boiler_eco_switch_off,number.boiler_wwecooff Geo 5xx,boiler,173,wwecoplusoff,eco+ switch off,uint (>=48<=63),C,true,number.boiler_eco+_switch_off,number.boiler_wwecoplusoff Geo 5xx,boiler,173,wwcomfdiff,comfort diff,uint (>=6<=12),K,true,number.boiler_comfort_diff,number.boiler_wwcomfdiff Geo 5xx,boiler,173,wwecodiff,eco diff,uint (>=6<=12),K,true,number.boiler_eco_diff,number.boiler_wwecodiff Geo 5xx,boiler,173,wwecoplusdiff,eco+ diff,uint (>=6<=12),K,true,number.boiler_eco+_diff,number.boiler_wwecoplusdiff Geo 5xx,boiler,173,wwcomfstop,comfort stop temp,uint (>=0<=254),C,true,number.boiler_comfort_stop_temp,number.boiler_wwcomfstop Geo 5xx,boiler,173,wwecostop,eco stop temp,uint (>=0<=254),C,true,number.boiler_eco_stop_temp,number.boiler_wwecostop Geo 5xx,boiler,173,wwecoplusstop,eco+ stop temp,uint (>=0<=254),C,true,number.boiler_eco+_stop_temp,number.boiler_wwecoplusstop Geo 5xx,boiler,173,hpcircpumpww,circulation pump available during dhw,boolean, ,true,switch.boiler_circulation_pump_available_during_dhw,switch.boiler_hpcircpumpww Geo 5xx,boiler,173,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Geo 5xx,boiler,173,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Geo 5xx,boiler,173,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Geo 5xx,boiler,173,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Geo 5xx,boiler,173,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Geo 5xx,boiler,173,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Geo 5xx,boiler,173,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Geo 5xx,boiler,173,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Geo 5xx,boiler,173,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Geo 5xx,boiler,173,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Geo 5xx,boiler,173,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Geo 5xx,boiler,173,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Geo 5xx,boiler,173,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Geo 5xx,boiler,173,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Geo 5xx,boiler,173,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Geo 5xx,boiler,173,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Geo 5xx,boiler,173,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Geo 5xx,boiler,173,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Geo 5xx,boiler,173,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Geo 5xx,boiler,173,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Geo 5xx,boiler,173,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Geo 5xx,boiler,173,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Geo 5xx,boiler,173,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Geo 5xx,boiler,173,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Geo 5xx,boiler,173,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Geo 5xx,boiler,173,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Geo 5xx,boiler,173,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Geo 5xx,boiler,173,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Geo 5xx,boiler,173,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Geo 5xx,boiler,173,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Geo 5xx,boiler,173,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Geo 5xx,boiler,173,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Geo 5xx,boiler,173,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Geo 5xx,boiler,173,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Geo 5xx,boiler,173,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Geo 5xx,boiler,173,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Geo 5xx,boiler,173,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Geo 5xx,boiler,173,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Geo 5xx,boiler,173,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Geo 5xx,boiler,173,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Logamax U122/Cerapur,boiler,203,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Logamax U122/Cerapur,boiler,203,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logamax U122/Cerapur,boiler,203,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logamax U122/Cerapur,boiler,203,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Logamax U122/Cerapur,boiler,203,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Logamax U122/Cerapur,boiler,203,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Logamax U122/Cerapur,boiler,203,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Logamax U122/Cerapur,boiler,203,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Logamax U122/Cerapur,boiler,203,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Logamax U122/Cerapur,boiler,203,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Logamax U122/Cerapur,boiler,203,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Logamax U122/Cerapur,boiler,203,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Logamax U122/Cerapur,boiler,203,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Logamax U122/Cerapur,boiler,203,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logamax U122/Cerapur,boiler,203,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logamax U122/Cerapur,boiler,203,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Logamax U122/Cerapur,boiler,203,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Logamax U122/Cerapur,boiler,203,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logamax U122/Cerapur,boiler,203,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logamax U122/Cerapur,boiler,203,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Logamax U122/Cerapur,boiler,203,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Logamax U122/Cerapur,boiler,203,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Logamax U122/Cerapur,boiler,203,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Logamax U122/Cerapur,boiler,203,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Logamax U122/Cerapur,boiler,203,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Logamax U122/Cerapur,boiler,203,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Logamax U122/Cerapur,boiler,203,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Logamax U122/Cerapur,boiler,203,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Logamax U122/Cerapur,boiler,203,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Logamax U122/Cerapur,boiler,203,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Logamax U122/Cerapur,boiler,203,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Logamax U122/Cerapur,boiler,203,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Logamax U122/Cerapur,boiler,203,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logamax U122/Cerapur,boiler,203,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Logamax U122/Cerapur,boiler,203,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logamax U122/Cerapur,boiler,203,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Logamax U122/Cerapur,boiler,203,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Logamax U122/Cerapur,boiler,203,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logamax U122/Cerapur,boiler,203,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logamax U122/Cerapur,boiler,203,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logamax U122/Cerapur,boiler,203,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Logamax U122/Cerapur,boiler,203,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logamax U122/Cerapur,boiler,203,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logamax U122/Cerapur,boiler,203,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Logamax U122/Cerapur,boiler,203,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Logamax U122/Cerapur,boiler,203,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Logamax U122/Cerapur,boiler,203,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Logamax U122/Cerapur,boiler,203,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Logamax U122/Cerapur,boiler,203,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Logamax U122/Cerapur,boiler,203,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Logamax U122/Cerapur,boiler,203,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Logamax U122/Cerapur,boiler,203,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logamax U122/Cerapur,boiler,203,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logamax U122/Cerapur,boiler,203,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Logamax U122/Cerapur,boiler,203,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Logamax U122/Cerapur,boiler,203,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Logamax U122/Cerapur,boiler,203,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Logamax U122/Cerapur,boiler,203,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Logamax U122/Cerapur,boiler,203,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Logamax U122/Cerapur,boiler,203,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Logamax U122/Cerapur,boiler,203,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Logamax U122/Cerapur,boiler,203,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Logamax U122/Cerapur,boiler,203,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Logamax U122/Cerapur,boiler,203,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Logamax U122/Cerapur,boiler,203,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Logamax U122/Cerapur,boiler,203,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Logamax U122/Cerapur,boiler,203,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Logamax U122/Cerapur,boiler,203,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Logamax U122/Cerapur,boiler,203,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Logamax U122/Cerapur,boiler,203,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Logamax U122/Cerapur,boiler,203,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Logamax U122/Cerapur,boiler,203,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Logamax U122/Cerapur,boiler,203,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Logamax U122/Cerapur,boiler,203,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Logamax U122/Cerapur,boiler,203,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Logamax U122/Cerapur,boiler,203,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Logamax U122/Cerapur,boiler,203,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Logamax U122/Cerapur,boiler,203,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Logamax U122/Cerapur,boiler,203,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Logamax U122/Cerapur,boiler,203,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Logamax U122/Cerapur,boiler,203,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Logamax U122/Cerapur,boiler,203,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Logamax U122/Cerapur,boiler,203,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Logamax U122/Cerapur,boiler,203,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Logamax U122/Cerapur,boiler,203,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Logamax U122/Cerapur,boiler,203,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Logamax U122/Cerapur,boiler,203,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Logamax U122/Cerapur,boiler,203,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Logamax U122/Cerapur,boiler,203,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Logamax U122/Cerapur,boiler,203,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Logamax U122/Cerapur,boiler,203,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Logamax U122/Cerapur,boiler,203,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Logamax U122/Cerapur,boiler,203,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Logamax U122/Cerapur,boiler,203,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Logamax U122/Cerapur,boiler,203,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Logamax U122/Cerapur,boiler,203,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Logamax U122/Cerapur,boiler,203,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Logamax U122/Cerapur,boiler,203,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Logamax U122/Cerapur,boiler,203,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Logamax U122/Cerapur,boiler,203,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Logamax U122/Cerapur,boiler,203,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Logamax U122/Cerapur,boiler,203,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Logamax U122/Cerapur,boiler,203,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Logamax U122/Cerapur,boiler,203,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Logamax U122/Cerapur,boiler,203,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Ecomline Excellent,boiler,206,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Ecomline Excellent,boiler,206,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Ecomline Excellent,boiler,206,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Ecomline Excellent,boiler,206,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Ecomline Excellent,boiler,206,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Ecomline Excellent,boiler,206,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Ecomline Excellent,boiler,206,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Ecomline Excellent,boiler,206,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Ecomline Excellent,boiler,206,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Ecomline Excellent,boiler,206,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Ecomline Excellent,boiler,206,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Ecomline Excellent,boiler,206,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Ecomline Excellent,boiler,206,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Ecomline Excellent,boiler,206,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Ecomline Excellent,boiler,206,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Ecomline Excellent,boiler,206,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Ecomline Excellent,boiler,206,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Ecomline Excellent,boiler,206,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Ecomline Excellent,boiler,206,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Ecomline Excellent,boiler,206,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Ecomline Excellent,boiler,206,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Ecomline Excellent,boiler,206,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Ecomline Excellent,boiler,206,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Ecomline Excellent,boiler,206,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Ecomline Excellent,boiler,206,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Ecomline Excellent,boiler,206,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Ecomline Excellent,boiler,206,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Ecomline Excellent,boiler,206,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Ecomline Excellent,boiler,206,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Ecomline Excellent,boiler,206,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Ecomline Excellent,boiler,206,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Ecomline Excellent,boiler,206,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Ecomline Excellent,boiler,206,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Ecomline Excellent,boiler,206,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Ecomline Excellent,boiler,206,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Ecomline Excellent,boiler,206,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Ecomline Excellent,boiler,206,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Ecomline Excellent,boiler,206,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Ecomline Excellent,boiler,206,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Ecomline Excellent,boiler,206,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Ecomline Excellent,boiler,206,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Ecomline Excellent,boiler,206,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Ecomline Excellent,boiler,206,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Ecomline Excellent,boiler,206,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Ecomline Excellent,boiler,206,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Ecomline Excellent,boiler,206,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Ecomline Excellent,boiler,206,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Ecomline Excellent,boiler,206,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Ecomline Excellent,boiler,206,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Ecomline Excellent,boiler,206,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Ecomline Excellent,boiler,206,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Ecomline Excellent,boiler,206,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Ecomline Excellent,boiler,206,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Ecomline Excellent,boiler,206,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Ecomline Excellent,boiler,206,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Ecomline Excellent,boiler,206,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Ecomline Excellent,boiler,206,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Ecomline Excellent,boiler,206,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Ecomline Excellent,boiler,206,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Ecomline Excellent,boiler,206,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Ecomline Excellent,boiler,206,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Ecomline Excellent,boiler,206,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Ecomline Excellent,boiler,206,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Ecomline Excellent,boiler,206,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Ecomline Excellent,boiler,206,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Ecomline Excellent,boiler,206,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Ecomline Excellent,boiler,206,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Ecomline Excellent,boiler,206,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Ecomline Excellent,boiler,206,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Ecomline Excellent,boiler,206,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Ecomline Excellent,boiler,206,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Ecomline Excellent,boiler,206,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Ecomline Excellent,boiler,206,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Ecomline Excellent,boiler,206,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Ecomline Excellent,boiler,206,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Ecomline Excellent,boiler,206,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Ecomline Excellent,boiler,206,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Ecomline Excellent,boiler,206,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Ecomline Excellent,boiler,206,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Ecomline Excellent,boiler,206,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Ecomline Excellent,boiler,206,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Ecomline Excellent,boiler,206,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Ecomline Excellent,boiler,206,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Ecomline Excellent,boiler,206,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Ecomline Excellent,boiler,206,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Ecomline Excellent,boiler,206,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Ecomline Excellent,boiler,206,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Ecomline Excellent,boiler,206,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Ecomline Excellent,boiler,206,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Ecomline Excellent,boiler,206,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Ecomline Excellent,boiler,206,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Ecomline Excellent,boiler,206,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Ecomline Excellent,boiler,206,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Ecomline Excellent,boiler,206,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Ecomline Excellent,boiler,206,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Ecomline Excellent,boiler,206,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Ecomline Excellent,boiler,206,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Ecomline Excellent,boiler,206,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Ecomline Excellent,boiler,206,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Ecomline Excellent,boiler,206,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Ecomline Excellent,boiler,206,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Ecomline Excellent,boiler,206,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Ecomline Excellent,boiler,206,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Ecomline Excellent,boiler,206,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Ecomline Excellent,boiler,206,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Cascade MC400,boiler,210,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Cascade MC400,boiler,210,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Cascade MC400,boiler,210,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Cascade MC400,boiler,210,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Cascade MC400,boiler,210,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Cascade MC400,boiler,210,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Cascade MC400,boiler,210,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Cascade MC400,boiler,210,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Cascade MC400,boiler,210,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Cascade MC400,boiler,210,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Cascade MC400,boiler,210,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Cascade MC400,boiler,210,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Cascade MC400,boiler,210,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Cascade MC400,boiler,210,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Cascade MC400,boiler,210,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Cascade MC400,boiler,210,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Cascade MC400,boiler,210,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Cascade MC400,boiler,210,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Cascade MC400,boiler,210,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Cascade MC400,boiler,210,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Cascade MC400,boiler,210,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Cascade MC400,boiler,210,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Cascade MC400,boiler,210,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Cascade MC400,boiler,210,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Cascade MC400,boiler,210,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Cascade MC400,boiler,210,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Cascade MC400,boiler,210,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Cascade MC400,boiler,210,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Cascade MC400,boiler,210,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Cascade MC400,boiler,210,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Cascade MC400,boiler,210,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Cascade MC400,boiler,210,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Cascade MC400,boiler,210,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Cascade MC400,boiler,210,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Cascade MC400,boiler,210,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Cascade MC400,boiler,210,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Cascade MC400,boiler,210,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Cascade MC400,boiler,210,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Cascade MC400,boiler,210,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Cascade MC400,boiler,210,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Cascade MC400,boiler,210,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Cascade MC400,boiler,210,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Cascade MC400,boiler,210,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Cascade MC400,boiler,210,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Cascade MC400,boiler,210,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Cascade MC400,boiler,210,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Cascade MC400,boiler,210,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Cascade MC400,boiler,210,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Cascade MC400,boiler,210,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Cascade MC400,boiler,210,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Cascade MC400,boiler,210,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Cascade MC400,boiler,210,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Cascade MC400,boiler,210,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Cascade MC400,boiler,210,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Cascade MC400,boiler,210,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Cascade MC400,boiler,210,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Cascade MC400,boiler,210,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Cascade MC400,boiler,210,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Cascade MC400,boiler,210,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Cascade MC400,boiler,210,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Cascade MC400,boiler,210,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Cascade MC400,boiler,210,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Cascade MC400,boiler,210,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Cascade MC400,boiler,210,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Cascade MC400,boiler,210,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Cascade MC400,boiler,210,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Cascade MC400,boiler,210,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Cascade MC400,boiler,210,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Cascade MC400,boiler,210,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Cascade MC400,boiler,210,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Cascade MC400,boiler,210,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Cascade MC400,boiler,210,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Cascade MC400,boiler,210,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Cascade MC400,boiler,210,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Cascade MC400,boiler,210,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Cascade MC400,boiler,210,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Cascade MC400,boiler,210,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Cascade MC400,boiler,210,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Cascade MC400,boiler,210,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Cascade MC400,boiler,210,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Cascade MC400,boiler,210,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Cascade MC400,boiler,210,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Cascade MC400,boiler,210,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Cascade MC400,boiler,210,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Cascade MC400,boiler,210,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Cascade MC400,boiler,210,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Cascade MC400,boiler,210,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Cascade MC400,boiler,210,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Cascade MC400,boiler,210,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Cascade MC400,boiler,210,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Cascade MC400,boiler,210,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Cascade MC400,boiler,210,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Cascade MC400,boiler,210,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Cascade MC400,boiler,210,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Cascade MC400,boiler,210,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Cascade MC400,boiler,210,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Cascade MC400,boiler,210,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Cascade MC400,boiler,210,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Cascade MC400,boiler,210,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Cascade MC400,boiler,210,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Cascade MC400,boiler,210,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Cascade MC400,boiler,210,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Cascade MC400,boiler,210,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Cascade MC400,boiler,210,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Cascade MC400,boiler,210,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww EasyControl Adapter,boiler,211,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset EasyControl Adapter,boiler,211,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff EasyControl Adapter,boiler,211,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive EasyControl Adapter,boiler,211,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive EasyControl Adapter,boiler,211,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp EasyControl Adapter,boiler,211,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod EasyControl Adapter,boiler,211,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp EasyControl Adapter,boiler,211,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp EasyControl Adapter,boiler,211,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp EasyControl Adapter,boiler,211,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp EasyControl Adapter,boiler,211,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress EasyControl Adapter,boiler,211,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp EasyControl Adapter,boiler,211,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp EasyControl Adapter,boiler,211,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp EasyControl Adapter,boiler,211,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas EasyControl Adapter,boiler,211,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 EasyControl Adapter,boiler,211,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr EasyControl Adapter,boiler,211,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork EasyControl Adapter,boiler,211,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork EasyControl Adapter,boiler,211,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat EasyControl Adapter,boiler,211,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower EasyControl Adapter,boiler,211,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower EasyControl Adapter,boiler,211,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod EasyControl Adapter,boiler,211,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow EasyControl Adapter,boiler,211,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock EasyControl Adapter,boiler,211,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston EasyControl Adapter,boiler,211,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff EasyControl Adapter,boiler,211,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston EasyControl Adapter,boiler,211,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff EasyControl Adapter,boiler,211,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon EasyControl Adapter,boiler,211,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase EasyControl Adapter,boiler,211,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend EasyControl Adapter,boiler,211,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp EasyControl Adapter,boiler,211,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode EasyControl Adapter,boiler,211,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp EasyControl Adapter,boiler,211,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated EasyControl Adapter,boiler,211,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp EasyControl Adapter,boiler,211,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump EasyControl Adapter,boiler,211,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax EasyControl Adapter,boiler,211,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin EasyControl Adapter,boiler,211,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode EasyControl Adapter,boiler,211,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay EasyControl Adapter,boiler,211,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp EasyControl Adapter,boiler,211,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow EasyControl Adapter,boiler,211,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow EasyControl Adapter,boiler,211,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow EasyControl Adapter,boiler,211,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts EasyControl Adapter,boiler,211,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin EasyControl Adapter,boiler,211,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin EasyControl Adapter,boiler,211,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin EasyControl Adapter,boiler,211,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts EasyControl Adapter,boiler,211,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime EasyControl Adapter,boiler,211,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode EasyControl Adapter,boiler,211,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode EasyControl Adapter,boiler,211,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber EasyControl Adapter,boiler,211,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage EasyControl Adapter,boiler,211,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance EasyControl Adapter,boiler,211,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime EasyControl Adapter,boiler,211,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate EasyControl Adapter,boiler,211,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops EasyControl Adapter,boiler,211,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp EasyControl Adapter,boiler,211,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated EasyControl Adapter,boiler,211,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp EasyControl Adapter,boiler,211,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp EasyControl Adapter,boiler,211,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow EasyControl Adapter,boiler,211,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus EasyControl Adapter,boiler,211,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff EasyControl Adapter,boiler,211,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle EasyControl Adapter,boiler,211,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp EasyControl Adapter,boiler,211,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype EasyControl Adapter,boiler,211,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort EasyControl Adapter,boiler,211,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 EasyControl Adapter,boiler,211,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset EasyControl Adapter,boiler,211,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization EasyControl Adapter,boiler,211,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower EasyControl Adapter,boiler,211,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp EasyControl Adapter,boiler,211,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump EasyControl Adapter,boiler,211,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype EasyControl Adapter,boiler,211,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston EasyControl Adapter,boiler,211,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff EasyControl Adapter,boiler,211,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp EasyControl Adapter,boiler,211,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode EasyControl Adapter,boiler,211,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc EasyControl Adapter,boiler,211,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp EasyControl Adapter,boiler,211,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 EasyControl Adapter,boiler,211,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow EasyControl Adapter,boiler,211,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 EasyControl Adapter,boiler,211,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 EasyControl Adapter,boiler,211,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated EasyControl Adapter,boiler,211,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime EasyControl Adapter,boiler,211,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting EasyControl Adapter,boiler,211,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging EasyControl Adapter,boiler,211,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging EasyControl Adapter,boiler,211,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok EasyControl Adapter,boiler,211,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive EasyControl Adapter,boiler,211,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve EasyControl Adapter,boiler,211,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower EasyControl Adapter,boiler,211,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp EasyControl Adapter,boiler,211,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp EasyControl Adapter,boiler,211,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts EasyControl Adapter,boiler,211,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm EasyControl Adapter,boiler,211,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower EasyControl Adapter,boiler,211,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal EasyControl Adapter,boiler,211,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat EasyControl Adapter,boiler,211,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Greenstar HIU/Logamax kompakt WS170,boiler,219,netflowtemp,heat network flow temp,ushort (>=0<=3199),C,false,sensor.boiler_heat_network_flow_temp,sensor.boiler_netflowtemp Greenstar HIU/Logamax kompakt WS170,boiler,219,heatvalve,heating valve,uint (>=0<=100),%,false,sensor.boiler_heating_valve,sensor.boiler_heatvalve Greenstar HIU/Logamax kompakt WS170,boiler,219,wwvalve,valve,uint (>=0<=100),%,false,sensor.boiler_valve,sensor.boiler_wwvalve Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Greenstar HIU/Logamax kompakt WS170,boiler,219,keepwarmtemp,keep warm temperature,uint (>=0<=254),C,true,number.boiler_keep_warm_temperature,number.boiler_keepwarmtemp Greenstar HIU/Logamax kompakt WS170,boiler,219,setreturntemp,set temp return,uint (>=0<=254),C,true,number.boiler_set_temp_return,number.boiler_setreturntemp Greenstar HIU/Logamax kompakt WS170,boiler,219,heating,heating,boolean, ,false,binary_sensor.boiler_heating,binary_sensor.boiler_heating Greenstar HIU/Logamax kompakt WS170,boiler,219,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Greenstar HIU/Logamax kompakt WS170,boiler,219,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Greenstar HIU/Logamax kompakt WS170,boiler,219,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Greenstar HIU/Logamax kompakt WS170,boiler,219,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Greenstar HIU/Logamax kompakt WS170,boiler,219,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Greenstar HIU/Logamax kompakt WS170,boiler,219,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Greenstar HIU/Logamax kompakt WS170,boiler,219,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Greenstar HIU/Logamax kompakt WS170,boiler,219,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Greenstar HIU/Logamax kompakt WS170,boiler,219,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Greenstar HIU/Logamax kompakt WS170,boiler,219,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Greenstar HIU/Logamax kompakt WS170,boiler,219,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Greenstar HIU/Logamax kompakt WS170,boiler,219,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Greenstar HIU/Logamax kompakt WS170,boiler,219,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Greenstar HIU/Logamax kompakt WS170,boiler,219,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Greenstar HIU/Logamax kompakt WS170,boiler,219,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Greenstar HIU/Logamax kompakt WS170,boiler,219,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Greenstar HIU/Logamax kompakt WS170,boiler,219,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Greenstar HIU/Logamax kompakt WS170,boiler,219,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Greenstar HIU/Logamax kompakt WS170,boiler,219,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Greenstar HIU/Logamax kompakt WS170,boiler,219,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Greenstar HIU/Logamax kompakt WS170,boiler,219,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Greenstar HIU/Logamax kompakt WS170,boiler,219,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Greenstar HIU/Logamax kompakt WS170,boiler,219,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Greenstar HIU/Logamax kompakt WS170,boiler,219,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Greenstar HIU/Logamax kompakt WS170,boiler,219,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Greenstar HIU/Logamax kompakt WS170,boiler,219,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Greenstar HIU/Logamax kompakt WS170,boiler,219,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Greenstar HIU/Logamax kompakt WS170,boiler,219,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Greenstar HIU/Logamax kompakt WS170,boiler,219,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Greenstar HIU/Logamax kompakt WS170,boiler,219,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Greenstar HIU/Logamax kompakt WS170,boiler,219,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Greenstar HIU/Logamax kompakt WS170,boiler,219,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Greenstar HIU/Logamax kompakt WS170,boiler,219,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Greenstar HIU/Logamax kompakt WS170,boiler,219,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Greenstar HIU/Logamax kompakt WS170,boiler,219,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Greenstar HIU/Logamax kompakt WS170,boiler,219,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Greenstar HIU/Logamax kompakt WS170,boiler,219,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Greenstar HIU/Logamax kompakt WS170,boiler,219,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Greenstar HIU/Logamax kompakt WS170,boiler,219,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Greenstar HIU/Logamax kompakt WS170,boiler,219,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Greenstar HIU/Logamax kompakt WS170,boiler,219,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Greenstar HIU/Logamax kompakt WS170,boiler,219,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Greenstar HIU/Logamax kompakt WS170,boiler,219,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Greenstar HIU/Logamax kompakt WS170,boiler,219,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Greenstar HIU/Logamax kompakt WS170,boiler,219,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Greenstar HIU/Logamax kompakt WS170,boiler,219,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Greenstar HIU/Logamax kompakt WS170,boiler,219,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Greenstar HIU/Logamax kompakt WS170,boiler,219,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Greenstar HIU/Logamax kompakt WS170,boiler,219,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Greenstar HIU/Logamax kompakt WS170,boiler,219,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Greenstar HIU/Logamax kompakt WS170,boiler,219,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Greenstar HIU/Logamax kompakt WS170,boiler,219,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Greenstar HIU/Logamax kompakt WS170,boiler,219,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Greenstar HIU/Logamax kompakt WS170,boiler,219,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Greenstar HIU/Logamax kompakt WS170,boiler,219,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Greenstar HIU/Logamax kompakt WS170,boiler,219,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Logamax Plus GB122/Condense 2300,boiler,234,reset,reset,cmd [-\|maintenance\|error], ,true,sensor.boiler_reset,sensor.boiler_reset Logamax Plus GB122/Condense 2300,boiler,234,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logamax Plus GB122/Condense 2300,boiler,234,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive Logamax Plus GB122/Condense 2300,boiler,234,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive Logamax Plus GB122/Condense 2300,boiler,234,selflowtemp,selected flow temperature,uint (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp Logamax Plus GB122/Condense 2300,boiler,234,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod Logamax Plus GB122/Condense 2300,boiler,234,outdoortemp,outside temperature,short (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp Logamax Plus GB122/Condense 2300,boiler,234,curflowtemp,current flow temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp Logamax Plus GB122/Condense 2300,boiler,234,rettemp,return temperature,ushort (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp Logamax Plus GB122/Condense 2300,boiler,234,switchtemp,mixing switch temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp Logamax Plus GB122/Condense 2300,boiler,234,syspress,system pressure,uint (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress Logamax Plus GB122/Condense 2300,boiler,234,boiltemp,actual boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp Logamax Plus GB122/Condense 2300,boiler,234,headertemp,low loss header,ushort (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp Logamax Plus GB122/Condense 2300,boiler,234,exhausttemp,exhaust temperature,ushort (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp Logamax Plus GB122/Condense 2300,boiler,234,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas Logamax Plus GB122/Condense 2300,boiler,234,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2 Logamax Plus GB122/Condense 2300,boiler,234,flamecurr,flame current,ushort (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr Logamax Plus GB122/Condense 2300,boiler,234,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork Logamax Plus GB122/Condense 2300,boiler,234,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork Logamax Plus GB122/Condense 2300,boiler,234,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat Logamax Plus GB122/Condense 2300,boiler,234,burnminpower,burner min power,uint (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower Logamax Plus GB122/Condense 2300,boiler,234,burnmaxpower,burner max power,uint (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower Logamax Plus GB122/Condense 2300,boiler,234,burnminperiod,burner min period,uint (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod Logamax Plus GB122/Condense 2300,boiler,234,absburnpow,burner current power (absolute),uint (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow Logamax Plus GB122/Condense 2300,boiler,234,heatblock,heating block,ushort (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock Logamax Plus GB122/Condense 2300,boiler,234,boilhyston,hysteresis on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston Logamax Plus GB122/Condense 2300,boiler,234,boilhystoff,hysteresis off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff Logamax Plus GB122/Condense 2300,boiler,234,boil2hyston,hysteresis stage 2 on temperature,int (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston Logamax Plus GB122/Condense 2300,boiler,234,boil2hystoff,hysteresis stage 2 off temperature,int (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff Logamax Plus GB122/Condense 2300,boiler,234,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Logamax Plus GB122/Condense 2300,boiler,234,curvebase,heatingcurve base,uint (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Logamax Plus GB122/Condense 2300,boiler,234,curveend,heatingcurve end,uint (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend Logamax Plus GB122/Condense 2300,boiler,234,summertemp,summer temperature,uint (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logamax Plus GB122/Condense 2300,boiler,234,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Logamax Plus GB122/Condense 2300,boiler,234,nofrosttemp,nofrost temperature,uint (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logamax Plus GB122/Condense 2300,boiler,234,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated Logamax Plus GB122/Condense 2300,boiler,234,heatingtemp,heating temperature,uint (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp Logamax Plus GB122/Condense 2300,boiler,234,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump Logamax Plus GB122/Condense 2300,boiler,234,pumpmodmax,boiler pump max power,uint (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logamax Plus GB122/Condense 2300,boiler,234,pumpmodmin,boiler pump min power,uint (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logamax Plus GB122/Condense 2300,boiler,234,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode Logamax Plus GB122/Condense 2300,boiler,234,pumpdelay,pump delay,uint (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logamax Plus GB122/Condense 2300,boiler,234,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logamax Plus GB122/Condense 2300,boiler,234,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow Logamax Plus GB122/Condense 2300,boiler,234,selburnpow,burner selected max power,uint (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow Logamax Plus GB122/Condense 2300,boiler,234,curburnpow,burner current power,uint (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow Logamax Plus GB122/Condense 2300,boiler,234,burnstarts,burner starts,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts Logamax Plus GB122/Condense 2300,boiler,234,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin Logamax Plus GB122/Condense 2300,boiler,234,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin Logamax Plus GB122/Condense 2300,boiler,234,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin Logamax Plus GB122/Condense 2300,boiler,234,heatstarts,burner starts heating,ulong (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts Logamax Plus GB122/Condense 2300,boiler,234,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime Logamax Plus GB122/Condense 2300,boiler,234,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode Logamax Plus GB122/Condense 2300,boiler,234,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode Logamax Plus GB122/Condense 2300,boiler,234,servicecodenumber,service code number,ushort (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber Logamax Plus GB122/Condense 2300,boiler,234,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage Logamax Plus GB122/Condense 2300,boiler,234,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance Logamax Plus GB122/Condense 2300,boiler,234,maintenancetime,time to next maintenance,ushort (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime Logamax Plus GB122/Condense 2300,boiler,234,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate Logamax Plus GB122/Condense 2300,boiler,234,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Logamax Plus GB122/Condense 2300,boiler,234,emergencytemp,emergency temperature,uint (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Logamax Plus GB122/Condense 2300,boiler,234,wwtapactivated,turn on/off,boolean, ,true,switch.boiler_turn_on/off,switch.boiler_wwtapactivated Logamax Plus GB122/Condense 2300,boiler,234,wwsettemp,set temperature,uint (>=0<=254),C,false,sensor.boiler_set_temperature,sensor.boiler_wwsettemp Logamax Plus GB122/Condense 2300,boiler,234,wwseltemp,selected temperature,uint (>=0<=254),C,true,number.boiler_selected_temperature,number.boiler_wwseltemp Logamax Plus GB122/Condense 2300,boiler,234,wwseltemplow,selected lower temperature,uint (>=0<=254),C,true,number.boiler_selected_lower_temperature,number.boiler_wwseltemplow Logamax Plus GB122/Condense 2300,boiler,234,wwtempecoplus,selected eco+ temperature,uint (>=0<=254),C,true,number.boiler_selected_eco+_temperature,number.boiler_wwtempecoplus Logamax Plus GB122/Condense 2300,boiler,234,wwseltempoff,selected temperature for off,uint (>=0<=254),C,false,sensor.boiler_selected_temperature_for_off,sensor.boiler_wwseltempoff Logamax Plus GB122/Condense 2300,boiler,234,wwseltempsingle,single charge temperature,uint (>=0<=254),C,true,number.boiler_single_charge_temperature,number.boiler_wwseltempsingle Logamax Plus GB122/Condense 2300,boiler,234,wwsolartemp,solar boiler temperature,ushort (>=0<=3199),C,false,sensor.boiler_solar_boiler_temperature,sensor.boiler_wwsolartemp Logamax Plus GB122/Condense 2300,boiler,234,wwtype,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_type,sensor.boiler_wwtype Logamax Plus GB122/Condense 2300,boiler,234,wwcomfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_comfort,select.boiler_wwcomfort Logamax Plus GB122/Condense 2300,boiler,234,wwcomfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_comfort_mode,select.boiler_wwcomfort1 Logamax Plus GB122/Condense 2300,boiler,234,wwflowtempoffset,flow temperature offset,uint (>=0<=100),C,true,number.boiler_flow_temperature_offset,number.boiler_wwflowtempoffset Logamax Plus GB122/Condense 2300,boiler,234,wwchargeoptimization,charge optimization,boolean, ,true,switch.boiler_charge_optimization,switch.boiler_wwchargeoptimization Logamax Plus GB122/Condense 2300,boiler,234,wwmaxpower,max power,uint (>=0<=254),%,true,number.boiler_max_power,number.boiler_wwmaxpower Logamax Plus GB122/Condense 2300,boiler,234,wwmaxtemp,maximum temperature,uint (>=0<=80),C,true,number.boiler_maximum_temperature,number.boiler_wwmaxtemp Logamax Plus GB122/Condense 2300,boiler,234,wwcircpump,circulation pump available,boolean, ,true,switch.boiler_circulation_pump_available,switch.boiler_wwcircpump Logamax Plus GB122/Condense 2300,boiler,234,wwchargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_charging_type,sensor.boiler_wwchargetype Logamax Plus GB122/Condense 2300,boiler,234,wwhyston,hysteresis on temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_on_temperature,number.boiler_wwhyston Logamax Plus GB122/Condense 2300,boiler,234,wwhystoff,hysteresis off temperature,int (>=-126<=126),C,true,number.boiler_hysteresis_off_temperature,number.boiler_wwhystoff Logamax Plus GB122/Condense 2300,boiler,234,wwdisinfectiontemp,disinfection temperature,uint (>=60<=80),C,true,number.boiler_disinfection_temperature,number.boiler_wwdisinfectiontemp Logamax Plus GB122/Condense 2300,boiler,234,wwcircmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_circulation_pump_mode,select.boiler_wwcircmode Logamax Plus GB122/Condense 2300,boiler,234,wwcirc,circulation active,boolean, ,true,switch.boiler_circulation_active,switch.boiler_wwcirc Logamax Plus GB122/Condense 2300,boiler,234,wwcurtemp,current intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_intern_temperature,sensor.boiler_wwcurtemp Logamax Plus GB122/Condense 2300,boiler,234,wwcurtemp2,current extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_current_extern_temperature,sensor.boiler_wwcurtemp2 Logamax Plus GB122/Condense 2300,boiler,234,wwcurflow,current tap water flow,uint (>=0<=25),l/min,false,sensor.boiler_current_tap_water_flow,sensor.boiler_wwcurflow Logamax Plus GB122/Condense 2300,boiler,234,wwstoragetemp1,storage intern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_intern_temperature,sensor.boiler_wwstoragetemp1 Logamax Plus GB122/Condense 2300,boiler,234,wwstoragetemp2,storage extern temperature,ushort (>=0<=3199),C,false,sensor.boiler_storage_extern_temperature,sensor.boiler_wwstoragetemp2 Logamax Plus GB122/Condense 2300,boiler,234,wwactivated,activated,boolean, ,true,switch.boiler_activated,switch.boiler_wwactivated Logamax Plus GB122/Condense 2300,boiler,234,wwonetime,one time charging,boolean, ,true,switch.boiler_one_time_charging,switch.boiler_wwonetime Logamax Plus GB122/Condense 2300,boiler,234,wwdisinfecting,disinfecting,boolean, ,true,switch.boiler_disinfecting,switch.boiler_wwdisinfecting Logamax Plus GB122/Condense 2300,boiler,234,wwcharging,charging,boolean, ,false,binary_sensor.boiler_charging,binary_sensor.boiler_wwcharging Logamax Plus GB122/Condense 2300,boiler,234,wwrecharging,recharging,boolean, ,false,binary_sensor.boiler_recharging,binary_sensor.boiler_wwrecharging Logamax Plus GB122/Condense 2300,boiler,234,wwtempok,temperature ok,boolean, ,false,binary_sensor.boiler_temperature_ok,binary_sensor.boiler_wwtempok Logamax Plus GB122/Condense 2300,boiler,234,wwactive,active,boolean, ,false,binary_sensor.boiler_active,binary_sensor.boiler_wwactive Logamax Plus GB122/Condense 2300,boiler,234,ww3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_3-way_valve_active,binary_sensor.boiler_ww3wayvalve Logamax Plus GB122/Condense 2300,boiler,234,wwsetpumppower,set pump power,uint (>=0<=100),%,false,sensor.boiler_set_pump_power,sensor.boiler_wwsetpumppower Logamax Plus GB122/Condense 2300,boiler,234,wwmixertemp,mixer temperature,ushort (>=0<=3199),C,false,sensor.boiler_mixer_temperature,sensor.boiler_wwmixertemp Logamax Plus GB122/Condense 2300,boiler,234,wwcylmiddletemp,cylinder middle temperature (TS3),ushort (>=0<=3199),C,false,sensor.boiler_cylinder_middle_temperature_(TS3),sensor.boiler_wwcylmiddletemp Logamax Plus GB122/Condense 2300,boiler,234,wwstarts,starts,ulong (>=0<=16777213), ,false,sensor.boiler_starts,sensor.boiler_wwstarts Logamax Plus GB122/Condense 2300,boiler,234,wwworkm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_active_time,sensor.boiler_wwworkm Logamax Plus GB122/Condense 2300,boiler,234,nompower,nominal Power,uint (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Logamax Plus GB122/Condense 2300,boiler,234,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Logamax Plus GB122/Condense 2300,boiler,234,nrgheat,energy heating,ulong (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat Logamax Plus GB122/Condense 2300,boiler,234,nrgww,energy,ulong (>=0<=10000000),kWh,true,number.boiler_energy,number.boiler_nrgww Logamatic TC100/Moduline Easy,thermostat,202,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Logamatic TC100/Moduline Easy,thermostat,202,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Logamatic TC100/Moduline Easy,thermostat,202,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime Logamatic TC100/Moduline Easy,thermostat,202,seltemp,selected room temperature,short (>=-319<=319),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp Logamatic TC100/Moduline Easy,thermostat,202,currtemp,current room temperature,short (>=-319<=319),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Logamatic TC100/Moduline Easy,thermostat,202,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate EasyControl/CT200,thermostat,203,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode EasyControl/CT200,thermostat,203,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode EasyControl/CT200,thermostat,203,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime EasyControl/CT200,thermostat,203,seltemp,selected room temperature,short (>=-319<=319),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp EasyControl/CT200,thermostat,203,currtemp,current room temperature,short (>=-319<=319),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp EasyControl/CT200,thermostat,203,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate UI800/BC400,thermostat,4,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode UI800/BC400,thermostat,4,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode UI800/BC400,thermostat,4,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime UI800/BC400,thermostat,4,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset UI800/BC400,thermostat,4,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry UI800/BC400,thermostat,4,dampedoutdoortemp,damped outdoor temperature,short (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp UI800/BC400,thermostat,4,floordrytemp,floor drying temperature,uint (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp UI800/BC400,thermostat,4,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building UI800/BC400,thermostat,4,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp UI800/BC400,thermostat,4,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping UI800/BC400,thermostat,4,wwsettemp,set temperature,uint (>=0<=254),C,true,number.thermostat_set_temperature,number.thermostat_wwsettemp UI800/BC400,thermostat,4,wwmode,mode,enum [off\|eco+\|eco\|comfort\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode UI800/BC400,thermostat,4,wwmode,mode,enum [off\|eco+\|eco\|comfort\|auto], ,true,select.thermostat_wwc2_mode,select.thermostat_wwc2_wwmode UI800/BC400,thermostat,4,wwsettemplow,set low temperature,uint (>=0<=254),C,true,number.thermostat_set_low_temperature,number.thermostat_wwsettemplow UI800/BC400,thermostat,4,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode UI800/BC400,thermostat,4,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_charge_duration,number.thermostat_wwchargeduration UI800/BC400,thermostat,4,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge UI800/BC400,thermostat,4,wwextra1,circuit 1 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_1_extra,sensor.thermostat_wwextra1 UI800/BC400,thermostat,4,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting UI800/BC400,thermostat,4,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday UI800/BC400,thermostat,4,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_disinfection_time,number.thermostat_wwdisinfecttime UI800/BC400,thermostat,4,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_daily_heating,switch.thermostat_wwdailyheating UI800/BC400,thermostat,4,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_daily_heating_time,number.thermostat_wwdailyheattime UI800/BC400,thermostat,4,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_wwc2_circulation_pump_mode,select.thermostat_wwc2_wwcircmode UI800/BC400,thermostat,4,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_wwc2_charge_duration,number.thermostat_wwc2_wwchargeduration UI800/BC400,thermostat,4,wwcharge,charge,boolean, ,true,switch.thermostat_wwc2_charge,switch.thermostat_wwc2_wwcharge UI800/BC400,thermostat,4,wwextra2,circuit 2 extra,uint (>=0<=254),C,false,sensor.thermostat_wwc2_circuit_2_extra,sensor.thermostat_wwc2_wwextra2 UI800/BC400,thermostat,4,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_wwc2_disinfecting,switch.thermostat_wwc2_wwdisinfecting UI800/BC400,thermostat,4,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_wwc2_disinfection_day,select.thermostat_wwc2_wwdisinfectday UI800/BC400,thermostat,4,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_disinfection_time,number.thermostat_wwc2_wwdisinfecttime UI800/BC400,thermostat,4,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_wwc2_daily_heating,switch.thermostat_wwc2_wwdailyheating UI800/BC400,thermostat,4,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_daily_heating_time,number.thermostat_wwc2_wwdailyheattime UI800/BC400,thermostat,4,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy UI800/BC400,thermostat,4,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp UI800/BC400,thermostat,4,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio UI800/BC400,thermostat,4,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor UI800/BC400,thermostat,4,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor UI800/BC400,thermostat,4,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler UI800/BC400,thermostat,4,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler UI800/BC400,thermostat,4,pvenableww,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenableww UI800/BC400,thermostat,4,pvraiseheat,raise heating with PV,int (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat UI800/BC400,thermostat,4,pvlowercool,lower cooling with PV,int (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool UI800/BC400,thermostat,4,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp UI800/BC400,thermostat,4,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp UI800/BC400,thermostat,4,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate UI800/BC400,thermostat,4,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode UI800/BC400,thermostat,4,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype UI800/BC400,thermostat,4,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp UI800/BC400,thermostat,4,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp UI800/BC400,thermostat,4,comforttemp,comfort temperature,uint (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp UI800/BC400,thermostat,4,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp UI800/BC400,thermostat,4,designtemp,design temperature,uint (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp UI800/BC400,thermostat,4,offsettemp,offset temperature,int (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp UI800/BC400,thermostat,4,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp UI800/BC400,thermostat,4,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp UI800/BC400,thermostat,4,roominfluence,room influence,uint (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence UI800/BC400,thermostat,4,roominflfactor,room influence factor,uint (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor UI800/BC400,thermostat,4,curroominfl,current room influence,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl UI800/BC400,thermostat,4,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode UI800/BC400,thermostat,4,nofrosttemp,nofrost temperature,int (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp UI800/BC400,thermostat,4,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp UI800/BC400,thermostat,4,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype UI800/BC400,thermostat,4,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode UI800/BC400,thermostat,4,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode UI800/BC400,thermostat,4,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode UI800/BC400,thermostat,4,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate UI800/BC400,thermostat,4,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode UI800/BC400,thermostat,4,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program UI800/BC400,thermostat,4,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp UI800/BC400,thermostat,4,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp UI800/BC400,thermostat,4,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup UI800/BC400,thermostat,4,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization UI800/BC400,thermostat,4,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode UI800/BC400,thermostat,4,noreducetemp,no reduce below temperature,int (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp UI800/BC400,thermostat,4,reducetemp,off/reduce switch temperature,int (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp UI800/BC400,thermostat,4,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio UI800/BC400,thermostat,4,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling UI800/BC400,thermostat,4,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon UI800/BC400,thermostat,4,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode UI800/BC400,thermostat,4,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset UI800/BC400,thermostat,4,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff UI800/BC400,thermostat,4,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp UI800/BC400,thermostat,4,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control UI800/BC400,thermostat,4,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp UI800/BC400,thermostat,4,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum UI800/BC400,thermostat,4,heatondelay,heat-on delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay UI800/BC400,thermostat,4,heatoffdelay,heat-off delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay UI800/BC400,thermostat,4,instantstart,instant start,uint (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart UI800/BC400,thermostat,4,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost UI800/BC400,thermostat,4,boosttime,boost time,uint (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime RC10,thermostat,65,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC10,thermostat,65,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC10,thermostat,65,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime RC10,thermostat,65,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp RC10,thermostat,65,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RC10,thermostat,65,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC10,thermostat,65,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC10,thermostat,65,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC10,thermostat,65,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype RC10,thermostat,65,daytemp,day temperature,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp RC10,thermostat,65,nighttemp,night temperature,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp RC10,thermostat,65,program,program,enum [family\|morning\|evening\|am\|pm\|midday\|singles\|seniors], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program RC10,thermostat,65,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp RC10,thermostat,65,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp RC10,thermostat,65,tempautotemp,temporary set temperature automode,uint (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp RC10,thermostat,65,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype RC10,thermostat,65,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp RC10,thermostat,65,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode RC10,thermostat,65,remotetemp,room temperature from remote,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp RC30,thermostat,67,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC30,thermostat,67,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC30,thermostat,67,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime RC30,thermostat,67,display,display,enum [internal temperature\|internal setpoint\|external temperature\|burner temperature\|ww temperature\|functioning mode\|time\|date\|smoke temperature], ,true,select.thermostat_display,select.thermostat_display RC30,thermostat,67,language,language,enum [german\|dutch\|french\|italian], ,false,sensor.thermostat_language,sensor.thermostat_language RC30,thermostat,67,clockoffset,clock offset,int (>=-126<=126),seconds,true,number.thermostat_clock_offset,number.thermostat_clockoffset RC30,thermostat,67,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset RC30,thermostat,67,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp RC30,thermostat,67,inttemp1,temperature sensor 1,short (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_1,sensor.thermostat_inttemp1 RC30,thermostat,67,inttemp2,temperature sensor 2,short (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_2,sensor.thermostat_inttemp2 RC30,thermostat,67,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping RC30,thermostat,67,dampedoutdoortemp,damped outdoor temperature,int (>=-126<=126),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp RC30,thermostat,67,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building RC30,thermostat,67,wwmode,mode,enum [off\|on\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode RC30,thermostat,67,wwcircmode,circulation pump mode,enum [off\|on\|auto], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode RC30,thermostat,67,wwprogmode,program,enum [std prog\|own prog], ,true,select.thermostat_program,select.thermostat_wwprogmode RC30,thermostat,67,wwcircprog,circulation program,enum [std prog\|own prog], ,true,select.thermostat_circulation_program,select.thermostat_wwcircprog RC30,thermostat,67,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting RC30,thermostat,67,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday RC30,thermostat,67,wwdisinfecthour,disinfection hour,uint (>=0<=23), ,true,number.thermostat_disinfection_hour,number.thermostat_wwdisinfecthour RC30,thermostat,67,wwmaxtemp,maximum temperature,uint (>=0<=254),C,true,number.thermostat_maximum_temperature,number.thermostat_wwmaxtemp RC30,thermostat,67,wwonetimekey,one time key function,boolean, ,true,switch.thermostat_one_time_key_function,switch.thermostat_wwonetimekey RC30,thermostat,67,wwswitchtime,program switchtime,string, ,true,sensor.thermostat_program_switchtime,sensor.thermostat_wwswitchtime RC30,thermostat,67,wwcircswitchtime,circulation program switchtime,string, ,true,sensor.thermostat_circulation_program_switchtime,sensor.thermostat_wwcircswitchtime RC30,thermostat,67,wwholidays,holiday dates,string, ,true,sensor.thermostat_holiday_dates,sensor.thermostat_wwholidays RC30,thermostat,67,wwvacations,vacation dates,string, ,true,sensor.thermostat_vacation_dates,sensor.thermostat_wwvacations RC30,thermostat,67,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RC30,thermostat,67,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC30,thermostat,67,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC30,thermostat,67,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC30,thermostat,67,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype RC30,thermostat,67,daytemp,day temperature,uint (>=10<=30),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp RC30,thermostat,67,nighttemp,night temperature,uint (>=10<=30),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp RC30,thermostat,67,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp RC30,thermostat,67,offsettemp,offset temperature,int (>=-5<=5),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp RC30,thermostat,67,holidaytemp,holiday temperature,uint (>=5<=30),C,true,number.thermostat_hc1_holiday_temperature,number.thermostat_hc1_holidaytemp RC30,thermostat,67,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp RC30,thermostat,67,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp RC30,thermostat,67,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode RC30,thermostat,67,holidaymode,holiday mode,boolean, ,false,binary_sensor.thermostat_hc1_holiday_mode,binary_sensor.thermostat_hc1_holidaymode RC30,thermostat,67,nofrosttemp,nofrost temperature,int (>=-20<=10),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp RC30,thermostat,67,nofrostmode,nofrost mode,enum [off\|outdoor\|room], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode RC30,thermostat,67,roominfluence,room influence,uint (>=0<=10),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence RC30,thermostat,67,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp RC30,thermostat,67,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp RC30,thermostat,67,flowtempoffset,flow temperature offset for mixer,uint (>=0<=20),C,true,number.thermostat_hc1_flow_temperature_offset_for_mixer,number.thermostat_hc1_flowtempoffset RC30,thermostat,67,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype RC30,thermostat,67,reducemode,reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode RC30,thermostat,67,controlmode,control mode,enum [outdoor\|room], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode RC30,thermostat,67,control,control device,enum [off\|RC20\|RC3x], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control RC30,thermostat,67,holidays,holiday dates,string, ,true,sensor.thermostat_hc1_holiday_dates,sensor.thermostat_hc1_holidays RC30,thermostat,67,vacations,vacation dates,string, ,true,sensor.thermostat_hc1_vacation_dates,sensor.thermostat_hc1_vacations RC30,thermostat,67,program,program,enum [own 1\|family\|morning\|evening\|am\|pm\|midday\|singles\|seniors\|new\|own 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program RC30,thermostat,67,pause,pause time,uint (>=0<=99),hours,true,number.thermostat_hc1_pause_time,number.thermostat_hc1_pause RC30,thermostat,67,party,party time,uint (>=0<=99),hours,true,number.thermostat_hc1_party_time,number.thermostat_hc1_party RC30,thermostat,67,tempautotemp,temporary set temperature automode,uint (>=0<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp RC30,thermostat,67,noreducetemp,no reduce below temperature,int (>=-31<=10),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp RC30,thermostat,67,reducetemp,off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp RC30,thermostat,67,vacreducetemp,vacations off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_vacations_off/reduce_switch_temperature,number.thermostat_hc1_vacreducetemp RC30,thermostat,67,vacreducemode,vacations reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_vacations_reduce_mode,select.thermostat_hc1_vacreducemode RC30,thermostat,67,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp RC30,thermostat,67,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio RC30,thermostat,67,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization RC30,thermostat,67,switchtime1,own1 program switchtime,string, ,true,sensor.thermostat_hc1_own1_program_switchtime,sensor.thermostat_hc1_switchtime1 RC30,thermostat,67,switchtime2,own2 program switchtime,string, ,true,sensor.thermostat_hc1_own2_program_switchtime,sensor.thermostat_hc1_switchtime2 RC20/Moduline 300,thermostat,77,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC20/Moduline 300,thermostat,77,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC20/Moduline 300,thermostat,77,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime RC20/Moduline 300,thermostat,77,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RC20/Moduline 300,thermostat,77,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC20/Moduline 300,thermostat,77,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC20/Moduline 300,thermostat,77,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC20/Moduline 300,thermostat,77,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp RC20/Moduline 300,thermostat,77,offtemp,temperature when mode is off,uint (>=0<=127),C,true,number.thermostat_hc1_temperature_when_mode_is_off,number.thermostat_hc1_offtemp RC20/Moduline 300,thermostat,77,daytemp2,day temperature T2,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T2,number.thermostat_hc1_daytemp2 RC20/Moduline 300,thermostat,77,daytemp3,day temperature T3,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T3,number.thermostat_hc1_daytemp3 RC20/Moduline 300,thermostat,77,daytemp4,day temperature T4,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T4,number.thermostat_hc1_daytemp4 RC20/Moduline 300,thermostat,77,nighttemp,night temperature T1,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature_T1,number.thermostat_hc1_nighttemp RC20/Moduline 300,thermostat,77,switchtime,program switchtime,string, ,true,sensor.thermostat_hc1_program_switchtime,sensor.thermostat_hc1_switchtime Moduline 400,thermostat,78,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Moduline 400,thermostat,78,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Moduline 400,thermostat,78,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime Moduline 400,thermostat,78,clockoffset,clock offset,int (>=-126<=126),seconds,true,number.thermostat_clock_offset,number.thermostat_clockoffset Moduline 400,thermostat,78,autodst,automatic change daylight saving time,boolean, ,true,switch.thermostat_automatic_change_daylight_saving_time,switch.thermostat_autodst Moduline 400,thermostat,78,language,language,enum [german\|dutch], ,true,select.thermostat_language,select.thermostat_language Moduline 400,thermostat,78,backlight,key backlight,boolean, ,true,switch.thermostat_key_backlight,switch.thermostat_backlight Moduline 400,thermostat,78,brightness,screen brightness,int (>=-15<=15), ,true,number.thermostat_screen_brightness,number.thermostat_brightness Moduline 400,thermostat,78,mixingvalves,mixing valves,uint (>=0<=2), ,true,number.thermostat_mixing_valves,number.thermostat_mixingvalves Moduline 400,thermostat,78,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building Moduline 400,thermostat,78,heatingpid,heating PID,enum [fast\|medium\|slow], ,true,select.thermostat_heating_PID,select.thermostat_heatingpid Moduline 400,thermostat,78,preheating,preheating in the clock program,boolean, ,true,switch.thermostat_preheating_in_the_clock_program,switch.thermostat_preheating Moduline 400,thermostat,78,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset Moduline 400,thermostat,78,wwmode,mode,enum [on\|off\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode Moduline 400,thermostat,78,wwwhenmodeoff,when thermostat mode off,boolean, ,true,switch.thermostat_when_thermostat_mode_off,switch.thermostat_wwwhenmodeoff Moduline 400,thermostat,78,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting Moduline 400,thermostat,78,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday Moduline 400,thermostat,78,wwdisinfecthour,disinfection hour,uint (>=0<=23), ,true,number.thermostat_disinfection_hour,number.thermostat_wwdisinfecthour Moduline 400,thermostat,78,wwholidays,holiday dates,string, ,true,sensor.thermostat_holiday_dates,sensor.thermostat_wwholidays Moduline 400,thermostat,78,wwvacations,vacation dates,string, ,true,sensor.thermostat_vacation_dates,sensor.thermostat_wwvacations Moduline 400,thermostat,78,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp Moduline 400,thermostat,78,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Moduline 400,thermostat,78,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate Moduline 400,thermostat,78,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode Moduline 400,thermostat,78,holidays,holiday dates,string, ,true,sensor.thermostat_hc1_holiday_dates,sensor.thermostat_hc1_holidays Moduline 400,thermostat,78,vacations,vacation dates,string, ,true,sensor.thermostat_hc1_vacation_dates,sensor.thermostat_hc1_vacations Moduline 400,thermostat,78,program,program,enum [own 1\|family\|morning\|evening\|am\|pm\|midday\|singles\|seniors\|new\|own 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program Moduline 400,thermostat,78,pause,pause time,uint (>=0<=254),hours,true,number.thermostat_hc1_pause_time,number.thermostat_hc1_pause Moduline 400,thermostat,78,party,party time,uint (>=0<=254),hours,true,number.thermostat_hc1_party_time,number.thermostat_hc1_party Moduline 400,thermostat,78,switchtime1,own1 program switchtime,string, ,true,sensor.thermostat_hc1_own1_program_switchtime,sensor.thermostat_hc1_switchtime1 Moduline 400,thermostat,78,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype Moduline 400,thermostat,78,controlmode,control mode,enum [outdoor\|room], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode Moduline 400,thermostat,78,holidaytemp,holiday temperature,uint (>=0<=127),C,true,number.thermostat_hc1_holiday_temperature,number.thermostat_hc1_holidaytemp Moduline 400,thermostat,78,nighttemp,night temperature T1,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature_T1,number.thermostat_hc1_nighttemp Moduline 400,thermostat,78,daytemp2,day temperature T2,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T2,number.thermostat_hc1_daytemp2 Moduline 400,thermostat,78,daytemp3,day temperature T3,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T3,number.thermostat_hc1_daytemp3 Moduline 400,thermostat,78,daytemp4,day temperature T4,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T4,number.thermostat_hc1_daytemp4 Moduline 400,thermostat,78,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp Moduline 400,thermostat,78,offtemp,temperature when mode is off,uint (>=0<=127),C,true,number.thermostat_hc1_temperature_when_mode_is_off,number.thermostat_hc1_offtemp RC10/Moduline 100,thermostat,79,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC10/Moduline 100,thermostat,79,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC10/Moduline 100,thermostat,79,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset RC10/Moduline 100,thermostat,79,heatingpid,heating PID,enum [fast\|medium\|slow], ,true,select.thermostat_heating_PID,select.thermostat_heatingpid RC10/Moduline 100,thermostat,79,backlight,key backlight,boolean, ,true,switch.thermostat_key_backlight,switch.thermostat_backlight RC10/Moduline 100,thermostat,79,wwmode,mode,enum [on\|off\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode RC10/Moduline 100,thermostat,79,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RC10/Moduline 100,thermostat,79,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC10/Moduline 100,thermostat,79,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC10/Moduline 100,thermostat,79,mode,mode,enum [nofrost\|night\|day], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC10/Moduline 100,thermostat,79,daytemp,day temperature,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp RC10/Moduline 100,thermostat,79,nighttemp,night temperature,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp RC10/Moduline 100,thermostat,79,reducehours,duration for nighttemp,uint (>=0<=254),hours,true,number.thermostat_hc1_duration_for_nighttemp,number.thermostat_hc1_reducehours RC10/Moduline 100,thermostat,79,reduceminutes,remaining time for nightmode,ushort (>=0<=31999),minutes,false,sensor.thermostat_hc1_remaining_time_for_nightmode,sensor.thermostat_hc1_reduceminutes Moduline 200,thermostat,80,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Moduline 200,thermostat,80,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Moduline 200,thermostat,80,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset Moduline 200,thermostat,80,heatingpid,heating PID,enum [fast\|medium\|slow], ,true,select.thermostat_heating_PID,select.thermostat_heatingpid Moduline 200,thermostat,80,backlight,key backlight,boolean, ,true,switch.thermostat_key_backlight,switch.thermostat_backlight Moduline 200,thermostat,80,wwmode,mode,enum [on\|off\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode Moduline 200,thermostat,80,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp Moduline 200,thermostat,80,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Moduline 200,thermostat,80,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate Moduline 200,thermostat,80,mode,mode,enum [nofrost\|night\|day], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode Moduline 200,thermostat,80,daytemp,day temperature,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp Moduline 200,thermostat,80,nighttemp,night temperature,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp Moduline 200,thermostat,80,reducehours,duration for nighttemp,uint (>=0<=254),hours,true,number.thermostat_hc1_duration_for_nighttemp,number.thermostat_hc1_reducehours Moduline 200,thermostat,80,reduceminutes,remaining time for nightmode,ushort (>=0<=31999),minutes,false,sensor.thermostat_hc1_remaining_time_for_nightmode,sensor.thermostat_hc1_reduceminutes RC35,thermostat,86,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC35,thermostat,86,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC35,thermostat,86,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime RC35,thermostat,86,intoffset,internal temperature offset,int (>=-5<=5),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset RC35,thermostat,86,minexttemp,minimal external temperature,int (>=-30<=0),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp RC35,thermostat,86,inttemp1,temperature sensor 1,short (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_1,sensor.thermostat_inttemp1 RC35,thermostat,86,inttemp2,temperature sensor 2,short (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_2,sensor.thermostat_inttemp2 RC35,thermostat,86,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping RC35,thermostat,86,dampedoutdoortemp,damped outdoor temperature,int (>=-126<=126),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp RC35,thermostat,86,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building RC35,thermostat,86,wwmode,mode,enum [off\|on\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode RC35,thermostat,86,wwcircmode,circulation pump mode,enum [off\|on\|auto], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode RC35,thermostat,86,wwprogmode,program,enum [std prog\|own prog], ,true,select.thermostat_program,select.thermostat_wwprogmode RC35,thermostat,86,wwcircprog,circulation program,enum [std prog\|own prog], ,true,select.thermostat_circulation_program,select.thermostat_wwcircprog RC35,thermostat,86,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting RC35,thermostat,86,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday RC35,thermostat,86,wwdisinfecthour,disinfection hour,uint (>=0<=23), ,true,number.thermostat_disinfection_hour,number.thermostat_wwdisinfecthour RC35,thermostat,86,wwmaxtemp,maximum temperature,uint (>=60<=80),C,true,number.thermostat_maximum_temperature,number.thermostat_wwmaxtemp RC35,thermostat,86,wwonetimekey,one time key function,boolean, ,true,switch.thermostat_one_time_key_function,switch.thermostat_wwonetimekey RC35,thermostat,86,wwswitchtime,program switchtime,string, ,true,sensor.thermostat_program_switchtime,sensor.thermostat_wwswitchtime RC35,thermostat,86,wwcircswitchtime,circulation program switchtime,string, ,true,sensor.thermostat_circulation_program_switchtime,sensor.thermostat_wwcircswitchtime RC35,thermostat,86,wwholidays,holiday dates,string, ,true,sensor.thermostat_holiday_dates,sensor.thermostat_wwholidays RC35,thermostat,86,wwvacations,vacation dates,string, ,true,sensor.thermostat_vacation_dates,sensor.thermostat_wwvacations RC35,thermostat,86,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RC35,thermostat,86,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC35,thermostat,86,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC35,thermostat,86,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC35,thermostat,86,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype RC35,thermostat,86,daytemp,day temperature,uint (>=10<=30),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp RC35,thermostat,86,nighttemp,night temperature,uint (>=10<=30),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp RC35,thermostat,86,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp RC35,thermostat,86,offsettemp,offset temperature,int (>=-5<=5),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp RC35,thermostat,86,holidaytemp,holiday temperature,uint (>=5<=30),C,true,number.thermostat_hc1_holiday_temperature,number.thermostat_hc1_holidaytemp RC35,thermostat,86,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp RC35,thermostat,86,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp RC35,thermostat,86,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode RC35,thermostat,86,holidaymode,holiday mode,boolean, ,false,binary_sensor.thermostat_hc1_holiday_mode,binary_sensor.thermostat_hc1_holidaymode RC35,thermostat,86,nofrosttemp,nofrost temperature,int (>=-20<=10),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp RC35,thermostat,86,nofrostmode,nofrost mode,enum [off\|outdoor\|room], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode RC35,thermostat,86,roominfluence,room influence,uint (>=0<=10),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence RC35,thermostat,86,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp RC35,thermostat,86,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp RC35,thermostat,86,flowtempoffset,flow temperature offset for mixer,uint (>=0<=20),C,true,number.thermostat_hc1_flow_temperature_offset_for_mixer,number.thermostat_hc1_flowtempoffset RC35,thermostat,86,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype RC35,thermostat,86,reducemode,reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode RC35,thermostat,86,controlmode,control mode,enum [outdoor\|room], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode RC35,thermostat,86,control,control device,enum [off\|RC20\|RC3x], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control RC35,thermostat,86,holidays,holiday dates,string, ,true,sensor.thermostat_hc1_holiday_dates,sensor.thermostat_hc1_holidays RC35,thermostat,86,vacations,vacation dates,string, ,true,sensor.thermostat_hc1_vacation_dates,sensor.thermostat_hc1_vacations RC35,thermostat,86,program,program,enum [own 1\|family\|morning\|evening\|am\|pm\|midday\|singles\|seniors\|new\|own 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program RC35,thermostat,86,pause,pause time,uint (>=0<=99),hours,true,number.thermostat_hc1_pause_time,number.thermostat_hc1_pause RC35,thermostat,86,party,party time,uint (>=0<=99),hours,true,number.thermostat_hc1_party_time,number.thermostat_hc1_party RC35,thermostat,86,tempautotemp,temporary set temperature automode,uint (>=0<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp RC35,thermostat,86,noreducetemp,no reduce below temperature,int (>=-31<=10),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp RC35,thermostat,86,reducetemp,off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp RC35,thermostat,86,vacreducetemp,vacations off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_vacations_off/reduce_switch_temperature,number.thermostat_hc1_vacreducetemp RC35,thermostat,86,vacreducemode,vacations reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_vacations_reduce_mode,select.thermostat_hc1_vacreducemode RC35,thermostat,86,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp RC35,thermostat,86,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio RC35,thermostat,86,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization RC35,thermostat,86,switchtime1,own1 program switchtime,string, ,true,sensor.thermostat_hc1_own1_program_switchtime,sensor.thermostat_hc1_switchtime1 RC35,thermostat,86,switchtime2,own2 program switchtime,string, ,true,sensor.thermostat_hc1_own2_program_switchtime,sensor.thermostat_hc1_switchtime2 RC10/Moduline 100,thermostat,90,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC10/Moduline 100,thermostat,90,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC10/Moduline 100,thermostat,90,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime RC10/Moduline 100,thermostat,90,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp RC10/Moduline 100,thermostat,90,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RC10/Moduline 100,thermostat,90,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC10/Moduline 100,thermostat,90,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC10/Moduline 100,thermostat,90,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC10/Moduline 100,thermostat,90,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype RC10/Moduline 100,thermostat,90,daytemp,day temperature,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp RC10/Moduline 100,thermostat,90,nighttemp,night temperature,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp RC10/Moduline 100,thermostat,90,program,program,enum [family\|morning\|evening\|am\|pm\|midday\|singles\|seniors], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program RC10/Moduline 100,thermostat,90,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp RC10/Moduline 100,thermostat,90,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp RC10/Moduline 100,thermostat,90,tempautotemp,temporary set temperature automode,uint (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp RC10/Moduline 100,thermostat,90,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype RC10/Moduline 100,thermostat,90,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp RC10/Moduline 100,thermostat,90,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode RC10/Moduline 100,thermostat,90,remotetemp,room temperature from remote,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp RC20RF,thermostat,93,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC20RF,thermostat,93,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC20RF,thermostat,93,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime RC20RF,thermostat,93,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RC20RF,thermostat,93,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC20RF,thermostat,93,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC20RF,thermostat,93,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC20RF,thermostat,93,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp RC20RF,thermostat,93,offtemp,temperature when mode is off,uint (>=0<=127),C,true,number.thermostat_hc1_temperature_when_mode_is_off,number.thermostat_hc1_offtemp RC20RF,thermostat,93,daytemp2,day temperature T2,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T2,number.thermostat_hc1_daytemp2 RC20RF,thermostat,93,daytemp3,day temperature T3,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T3,number.thermostat_hc1_daytemp3 RC20RF,thermostat,93,daytemp4,day temperature T4,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature_T4,number.thermostat_hc1_daytemp4 RC20RF,thermostat,93,nighttemp,night temperature T1,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature_T1,number.thermostat_hc1_nighttemp RC20RF,thermostat,93,switchtime,program switchtime,string, ,true,sensor.thermostat_hc1_program_switchtime,sensor.thermostat_hc1_switchtime RFM20 Remote,thermostat,94,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RFM20 Remote,thermostat,94,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RFM20 Remote,thermostat,94,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime RFM20 Remote,thermostat,94,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RFM20 Remote,thermostat,94,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RFM20 Remote,thermostat,94,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC25,thermostat,151,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC25,thermostat,151,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC25,thermostat,151,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime RC25,thermostat,151,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp RC25,thermostat,151,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RC25,thermostat,151,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC25,thermostat,151,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC25,thermostat,151,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC25,thermostat,151,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype RC25,thermostat,151,daytemp,day temperature,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp RC25,thermostat,151,nighttemp,night temperature,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp RC25,thermostat,151,program,program,enum [family\|morning\|evening\|am\|pm\|midday\|singles\|seniors], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program RC25,thermostat,151,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp RC25,thermostat,151,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp RC25,thermostat,151,tempautotemp,temporary set temperature automode,uint (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp RC25,thermostat,151,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype RC25,thermostat,151,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp RC25,thermostat,151,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode RC200/CW100,thermostat,157,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC200/CW100,thermostat,157,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC200/CW100,thermostat,157,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime RC200/CW100,thermostat,157,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset RC200/CW100,thermostat,157,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry RC200/CW100,thermostat,157,dampedoutdoortemp,damped outdoor temperature,short (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp RC200/CW100,thermostat,157,floordrytemp,floor drying temperature,uint (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp RC200/CW100,thermostat,157,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building RC200/CW100,thermostat,157,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp RC200/CW100,thermostat,157,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping RC200/CW100,thermostat,157,wwsettemp,set temperature,uint (>=0<=254),C,true,number.thermostat_set_temperature,number.thermostat_wwsettemp RC200/CW100,thermostat,157,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_mode,select.thermostat_wwmode RC200/CW100,thermostat,157,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_wwc2_mode,select.thermostat_wwc2_wwmode RC200/CW100,thermostat,157,wwsettemplow,set low temperature,uint (>=0<=254),C,true,number.thermostat_set_low_temperature,number.thermostat_wwsettemplow RC200/CW100,thermostat,157,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode RC200/CW100,thermostat,157,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_charge_duration,number.thermostat_wwchargeduration RC200/CW100,thermostat,157,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge RC200/CW100,thermostat,157,wwextra1,circuit 1 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_1_extra,sensor.thermostat_wwextra1 RC200/CW100,thermostat,157,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting RC200/CW100,thermostat,157,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday RC200/CW100,thermostat,157,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_disinfection_time,number.thermostat_wwdisinfecttime RC200/CW100,thermostat,157,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_daily_heating,switch.thermostat_wwdailyheating RC200/CW100,thermostat,157,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_daily_heating_time,number.thermostat_wwdailyheattime RC200/CW100,thermostat,157,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_wwc2_circulation_pump_mode,select.thermostat_wwc2_wwcircmode RC200/CW100,thermostat,157,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_wwc2_charge_duration,number.thermostat_wwc2_wwchargeduration RC200/CW100,thermostat,157,wwcharge,charge,boolean, ,true,switch.thermostat_wwc2_charge,switch.thermostat_wwc2_wwcharge RC200/CW100,thermostat,157,wwextra2,circuit 2 extra,uint (>=0<=254),C,false,sensor.thermostat_wwc2_circuit_2_extra,sensor.thermostat_wwc2_wwextra2 RC200/CW100,thermostat,157,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_wwc2_disinfecting,switch.thermostat_wwc2_wwdisinfecting RC200/CW100,thermostat,157,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_wwc2_disinfection_day,select.thermostat_wwc2_wwdisinfectday RC200/CW100,thermostat,157,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_disinfection_time,number.thermostat_wwc2_wwdisinfecttime RC200/CW100,thermostat,157,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_wwc2_daily_heating,switch.thermostat_wwc2_wwdailyheating RC200/CW100,thermostat,157,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_daily_heating_time,number.thermostat_wwc2_wwdailyheattime RC200/CW100,thermostat,157,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy RC200/CW100,thermostat,157,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp RC200/CW100,thermostat,157,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio RC200/CW100,thermostat,157,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor RC200/CW100,thermostat,157,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor RC200/CW100,thermostat,157,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler RC200/CW100,thermostat,157,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler RC200/CW100,thermostat,157,pvenableww,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenableww RC200/CW100,thermostat,157,pvraiseheat,raise heating with PV,int (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat RC200/CW100,thermostat,157,pvlowercool,lower cooling with PV,int (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool RC200/CW100,thermostat,157,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RC200/CW100,thermostat,157,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC200/CW100,thermostat,157,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC200/CW100,thermostat,157,mode,mode,enum [manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC200/CW100,thermostat,157,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype RC200/CW100,thermostat,157,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp RC200/CW100,thermostat,157,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp RC200/CW100,thermostat,157,comforttemp,comfort temperature,uint (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp RC200/CW100,thermostat,157,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp RC200/CW100,thermostat,157,designtemp,design temperature,uint (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp RC200/CW100,thermostat,157,offsettemp,offset temperature,int (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp RC200/CW100,thermostat,157,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp RC200/CW100,thermostat,157,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp RC200/CW100,thermostat,157,roominfluence,room influence,uint (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence RC200/CW100,thermostat,157,roominflfactor,room influence factor,uint (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor RC200/CW100,thermostat,157,curroominfl,current room influence,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl RC200/CW100,thermostat,157,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode RC200/CW100,thermostat,157,nofrosttemp,nofrost temperature,int (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp RC200/CW100,thermostat,157,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp RC200/CW100,thermostat,157,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype RC200/CW100,thermostat,157,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode RC200/CW100,thermostat,157,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode RC200/CW100,thermostat,157,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode RC200/CW100,thermostat,157,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate RC200/CW100,thermostat,157,controlmode,control mode,enum [optimized\|simple\|n/a\|room\|power], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode RC200/CW100,thermostat,157,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program RC200/CW100,thermostat,157,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp RC200/CW100,thermostat,157,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp RC200/CW100,thermostat,157,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup RC200/CW100,thermostat,157,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization RC200/CW100,thermostat,157,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode RC200/CW100,thermostat,157,noreducetemp,no reduce below temperature,int (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp RC200/CW100,thermostat,157,reducetemp,off/reduce switch temperature,int (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp RC200/CW100,thermostat,157,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio RC200/CW100,thermostat,157,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling RC200/CW100,thermostat,157,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon RC200/CW100,thermostat,157,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode RC200/CW100,thermostat,157,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset RC200/CW100,thermostat,157,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff RC200/CW100,thermostat,157,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp RC200/CW100,thermostat,157,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control RC200/CW100,thermostat,157,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp RC200/CW100,thermostat,157,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum RC200/CW100,thermostat,157,heatondelay,heat-on delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay RC200/CW100,thermostat,157,heatoffdelay,heat-off delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay RC200/CW100,thermostat,157,instantstart,instant start,uint (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart RC200/CW100,thermostat,157,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost RC200/CW100,thermostat,157,boosttime,boost time,uint (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dampedoutdoortemp,damped outdoor temperature,short (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,floordrytemp,floor drying temperature,uint (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwsettemp,set temperature,uint (>=0<=254),C,true,number.thermostat_set_temperature,number.thermostat_wwsettemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_mode,select.thermostat_wwmode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_wwc2_mode,select.thermostat_wwc2_wwmode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwsettemplow,set low temperature,uint (>=0<=254),C,true,number.thermostat_set_low_temperature,number.thermostat_wwsettemplow RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_charge_duration,number.thermostat_wwchargeduration RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwextra1,circuit 1 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_1_extra,sensor.thermostat_wwextra1 RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_disinfection_time,number.thermostat_wwdisinfecttime RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_daily_heating,switch.thermostat_wwdailyheating RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_daily_heating_time,number.thermostat_wwdailyheattime RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_wwc2_circulation_pump_mode,select.thermostat_wwc2_wwcircmode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_wwc2_charge_duration,number.thermostat_wwc2_wwchargeduration RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwcharge,charge,boolean, ,true,switch.thermostat_wwc2_charge,switch.thermostat_wwc2_wwcharge RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwextra2,circuit 2 extra,uint (>=0<=254),C,false,sensor.thermostat_wwc2_circuit_2_extra,sensor.thermostat_wwc2_wwextra2 RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_wwc2_disinfecting,switch.thermostat_wwc2_wwdisinfecting RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_wwc2_disinfection_day,select.thermostat_wwc2_wwdisinfectday RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_disinfection_time,number.thermostat_wwc2_wwdisinfecttime RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_wwc2_daily_heating,switch.thermostat_wwc2_wwdailyheating RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_daily_heating_time,number.thermostat_wwc2_wwdailyheattime RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,pvenableww,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenableww RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,pvraiseheat,raise heating with PV,int (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,pvlowercool,lower cooling with PV,int (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,mode,mode,enum [manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,comforttemp,comfort temperature,uint (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,designtemp,design temperature,uint (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,offsettemp,offset temperature,int (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,roominfluence,room influence,uint (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,roominflfactor,room influence factor,uint (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,curroominfl,current room influence,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,nofrosttemp,nofrost temperature,int (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,noreducetemp,no reduce below temperature,int (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,reducetemp,off/reduce switch temperature,int (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,heatondelay,heat-on delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,heatoffdelay,heat-off delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,instantstart,instant start,uint (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,boosttime,boost time,uint (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime RC100/Moduline 1000/1010,thermostat,165,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC100/Moduline 1000/1010,thermostat,165,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC100/Moduline 1000/1010,thermostat,165,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime RC100/Moduline 1000/1010,thermostat,165,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset RC100/Moduline 1000/1010,thermostat,165,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry RC100/Moduline 1000/1010,thermostat,165,dampedoutdoortemp,damped outdoor temperature,short (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp RC100/Moduline 1000/1010,thermostat,165,floordrytemp,floor drying temperature,uint (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp RC100/Moduline 1000/1010,thermostat,165,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building RC100/Moduline 1000/1010,thermostat,165,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp RC100/Moduline 1000/1010,thermostat,165,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping RC100/Moduline 1000/1010,thermostat,165,wwsettemp,set temperature,uint (>=0<=254),C,true,number.thermostat_set_temperature,number.thermostat_wwsettemp RC100/Moduline 1000/1010,thermostat,165,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_mode,select.thermostat_wwmode RC100/Moduline 1000/1010,thermostat,165,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_wwc2_mode,select.thermostat_wwc2_wwmode RC100/Moduline 1000/1010,thermostat,165,wwsettemplow,set low temperature,uint (>=0<=254),C,true,number.thermostat_set_low_temperature,number.thermostat_wwsettemplow RC100/Moduline 1000/1010,thermostat,165,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode RC100/Moduline 1000/1010,thermostat,165,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_charge_duration,number.thermostat_wwchargeduration RC100/Moduline 1000/1010,thermostat,165,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge RC100/Moduline 1000/1010,thermostat,165,wwextra1,circuit 1 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_1_extra,sensor.thermostat_wwextra1 RC100/Moduline 1000/1010,thermostat,165,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting RC100/Moduline 1000/1010,thermostat,165,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday RC100/Moduline 1000/1010,thermostat,165,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_disinfection_time,number.thermostat_wwdisinfecttime RC100/Moduline 1000/1010,thermostat,165,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_daily_heating,switch.thermostat_wwdailyheating RC100/Moduline 1000/1010,thermostat,165,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_daily_heating_time,number.thermostat_wwdailyheattime RC100/Moduline 1000/1010,thermostat,165,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_wwc2_circulation_pump_mode,select.thermostat_wwc2_wwcircmode RC100/Moduline 1000/1010,thermostat,165,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_wwc2_charge_duration,number.thermostat_wwc2_wwchargeduration RC100/Moduline 1000/1010,thermostat,165,wwcharge,charge,boolean, ,true,switch.thermostat_wwc2_charge,switch.thermostat_wwc2_wwcharge RC100/Moduline 1000/1010,thermostat,165,wwextra2,circuit 2 extra,uint (>=0<=254),C,false,sensor.thermostat_wwc2_circuit_2_extra,sensor.thermostat_wwc2_wwextra2 RC100/Moduline 1000/1010,thermostat,165,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_wwc2_disinfecting,switch.thermostat_wwc2_wwdisinfecting RC100/Moduline 1000/1010,thermostat,165,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_wwc2_disinfection_day,select.thermostat_wwc2_wwdisinfectday RC100/Moduline 1000/1010,thermostat,165,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_disinfection_time,number.thermostat_wwc2_wwdisinfecttime RC100/Moduline 1000/1010,thermostat,165,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_wwc2_daily_heating,switch.thermostat_wwc2_wwdailyheating RC100/Moduline 1000/1010,thermostat,165,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_daily_heating_time,number.thermostat_wwc2_wwdailyheattime RC100/Moduline 1000/1010,thermostat,165,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy RC100/Moduline 1000/1010,thermostat,165,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp RC100/Moduline 1000/1010,thermostat,165,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio RC100/Moduline 1000/1010,thermostat,165,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor RC100/Moduline 1000/1010,thermostat,165,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor RC100/Moduline 1000/1010,thermostat,165,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler RC100/Moduline 1000/1010,thermostat,165,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler RC100/Moduline 1000/1010,thermostat,165,pvenableww,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenableww RC100/Moduline 1000/1010,thermostat,165,pvraiseheat,raise heating with PV,int (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat RC100/Moduline 1000/1010,thermostat,165,pvlowercool,lower cooling with PV,int (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool RC100/Moduline 1000/1010,thermostat,165,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RC100/Moduline 1000/1010,thermostat,165,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC100/Moduline 1000/1010,thermostat,165,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC100/Moduline 1000/1010,thermostat,165,mode,mode,enum [manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode RC100/Moduline 1000/1010,thermostat,165,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype RC100/Moduline 1000/1010,thermostat,165,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp RC100/Moduline 1000/1010,thermostat,165,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp RC100/Moduline 1000/1010,thermostat,165,comforttemp,comfort temperature,uint (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp RC100/Moduline 1000/1010,thermostat,165,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp RC100/Moduline 1000/1010,thermostat,165,designtemp,design temperature,uint (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp RC100/Moduline 1000/1010,thermostat,165,offsettemp,offset temperature,int (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp RC100/Moduline 1000/1010,thermostat,165,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp RC100/Moduline 1000/1010,thermostat,165,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp RC100/Moduline 1000/1010,thermostat,165,roominfluence,room influence,uint (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence RC100/Moduline 1000/1010,thermostat,165,roominflfactor,room influence factor,uint (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor RC100/Moduline 1000/1010,thermostat,165,curroominfl,current room influence,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl RC100/Moduline 1000/1010,thermostat,165,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode RC100/Moduline 1000/1010,thermostat,165,nofrosttemp,nofrost temperature,int (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp RC100/Moduline 1000/1010,thermostat,165,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp RC100/Moduline 1000/1010,thermostat,165,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype RC100/Moduline 1000/1010,thermostat,165,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode RC100/Moduline 1000/1010,thermostat,165,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode RC100/Moduline 1000/1010,thermostat,165,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode RC100/Moduline 1000/1010,thermostat,165,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate RC100/Moduline 1000/1010,thermostat,165,controlmode,control mode,enum [optimized\|simple\|n/a\|room\|power], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode RC100/Moduline 1000/1010,thermostat,165,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program RC100/Moduline 1000/1010,thermostat,165,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp RC100/Moduline 1000/1010,thermostat,165,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp RC100/Moduline 1000/1010,thermostat,165,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup RC100/Moduline 1000/1010,thermostat,165,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization RC100/Moduline 1000/1010,thermostat,165,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode RC100/Moduline 1000/1010,thermostat,165,noreducetemp,no reduce below temperature,int (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp RC100/Moduline 1000/1010,thermostat,165,reducetemp,off/reduce switch temperature,int (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp RC100/Moduline 1000/1010,thermostat,165,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio RC100/Moduline 1000/1010,thermostat,165,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling RC100/Moduline 1000/1010,thermostat,165,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon RC100/Moduline 1000/1010,thermostat,165,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode RC100/Moduline 1000/1010,thermostat,165,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset RC100/Moduline 1000/1010,thermostat,165,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff RC100/Moduline 1000/1010,thermostat,165,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp RC100/Moduline 1000/1010,thermostat,165,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control RC100/Moduline 1000/1010,thermostat,165,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp RC100/Moduline 1000/1010,thermostat,165,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum RC100/Moduline 1000/1010,thermostat,165,heatondelay,heat-on delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay RC100/Moduline 1000/1010,thermostat,165,heatoffdelay,heat-off delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay RC100/Moduline 1000/1010,thermostat,165,instantstart,instant start,uint (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart RC100/Moduline 1000/1010,thermostat,165,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost RC100/Moduline 1000/1010,thermostat,165,boosttime,boost time,uint (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime Rego 2000/3000,thermostat,172,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Rego 2000/3000,thermostat,172,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Rego 2000/3000,thermostat,172,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime Rego 2000/3000,thermostat,172,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset Rego 2000/3000,thermostat,172,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry Rego 2000/3000,thermostat,172,dampedoutdoortemp,damped outdoor temperature,short (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp Rego 2000/3000,thermostat,172,floordrytemp,floor drying temperature,uint (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp Rego 2000/3000,thermostat,172,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building Rego 2000/3000,thermostat,172,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp Rego 2000/3000,thermostat,172,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping Rego 2000/3000,thermostat,172,wwsettemp,set temperature,uint (>=0<=254),C,true,number.thermostat_set_temperature,number.thermostat_wwsettemp Rego 2000/3000,thermostat,172,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_mode,select.thermostat_wwmode Rego 2000/3000,thermostat,172,wwmode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_wwc2_mode,select.thermostat_wwc2_wwmode Rego 2000/3000,thermostat,172,wwsettemplow,set low temperature,uint (>=0<=254),C,true,number.thermostat_set_low_temperature,number.thermostat_wwsettemplow Rego 2000/3000,thermostat,172,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode Rego 2000/3000,thermostat,172,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_charge_duration,number.thermostat_wwchargeduration Rego 2000/3000,thermostat,172,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge Rego 2000/3000,thermostat,172,wwextra1,circuit 1 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_1_extra,sensor.thermostat_wwextra1 Rego 2000/3000,thermostat,172,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting Rego 2000/3000,thermostat,172,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday Rego 2000/3000,thermostat,172,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_disinfection_time,number.thermostat_wwdisinfecttime Rego 2000/3000,thermostat,172,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_daily_heating,switch.thermostat_wwdailyheating Rego 2000/3000,thermostat,172,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_daily_heating_time,number.thermostat_wwdailyheattime Rego 2000/3000,thermostat,172,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_wwc2_circulation_pump_mode,select.thermostat_wwc2_wwcircmode Rego 2000/3000,thermostat,172,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_wwc2_charge_duration,number.thermostat_wwc2_wwchargeduration Rego 2000/3000,thermostat,172,wwcharge,charge,boolean, ,true,switch.thermostat_wwc2_charge,switch.thermostat_wwc2_wwcharge Rego 2000/3000,thermostat,172,wwextra2,circuit 2 extra,uint (>=0<=254),C,false,sensor.thermostat_wwc2_circuit_2_extra,sensor.thermostat_wwc2_wwextra2 Rego 2000/3000,thermostat,172,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_wwc2_disinfecting,switch.thermostat_wwc2_wwdisinfecting Rego 2000/3000,thermostat,172,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_wwc2_disinfection_day,select.thermostat_wwc2_wwdisinfectday Rego 2000/3000,thermostat,172,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_disinfection_time,number.thermostat_wwc2_wwdisinfecttime Rego 2000/3000,thermostat,172,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_wwc2_daily_heating,switch.thermostat_wwc2_wwdailyheating Rego 2000/3000,thermostat,172,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_daily_heating_time,number.thermostat_wwc2_wwdailyheattime Rego 2000/3000,thermostat,172,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy Rego 2000/3000,thermostat,172,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp Rego 2000/3000,thermostat,172,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio Rego 2000/3000,thermostat,172,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor Rego 2000/3000,thermostat,172,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor Rego 2000/3000,thermostat,172,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler Rego 2000/3000,thermostat,172,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler Rego 2000/3000,thermostat,172,pvenableww,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenableww Rego 2000/3000,thermostat,172,pvraiseheat,raise heating with PV,int (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat Rego 2000/3000,thermostat,172,pvlowercool,lower cooling with PV,int (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool Rego 2000/3000,thermostat,172,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp Rego 2000/3000,thermostat,172,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Rego 2000/3000,thermostat,172,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate Rego 2000/3000,thermostat,172,mode,mode,enum [manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode Rego 2000/3000,thermostat,172,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype Rego 2000/3000,thermostat,172,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp Rego 2000/3000,thermostat,172,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp Rego 2000/3000,thermostat,172,comforttemp,comfort temperature,uint (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp Rego 2000/3000,thermostat,172,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp Rego 2000/3000,thermostat,172,designtemp,design temperature,uint (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp Rego 2000/3000,thermostat,172,offsettemp,offset temperature,int (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp Rego 2000/3000,thermostat,172,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp Rego 2000/3000,thermostat,172,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp Rego 2000/3000,thermostat,172,roominfluence,room influence,uint (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence Rego 2000/3000,thermostat,172,roominflfactor,room influence factor,uint (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor Rego 2000/3000,thermostat,172,curroominfl,current room influence,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl Rego 2000/3000,thermostat,172,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode Rego 2000/3000,thermostat,172,nofrosttemp,nofrost temperature,int (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp Rego 2000/3000,thermostat,172,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp Rego 2000/3000,thermostat,172,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype Rego 2000/3000,thermostat,172,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode Rego 2000/3000,thermostat,172,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode Rego 2000/3000,thermostat,172,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode Rego 2000/3000,thermostat,172,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate Rego 2000/3000,thermostat,172,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode Rego 2000/3000,thermostat,172,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program Rego 2000/3000,thermostat,172,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp Rego 2000/3000,thermostat,172,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp Rego 2000/3000,thermostat,172,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup Rego 2000/3000,thermostat,172,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization Rego 2000/3000,thermostat,172,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode Rego 2000/3000,thermostat,172,noreducetemp,no reduce below temperature,int (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp Rego 2000/3000,thermostat,172,reducetemp,off/reduce switch temperature,int (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp Rego 2000/3000,thermostat,172,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio Rego 2000/3000,thermostat,172,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling Rego 2000/3000,thermostat,172,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon Rego 2000/3000,thermostat,172,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode Rego 2000/3000,thermostat,172,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset Rego 2000/3000,thermostat,172,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff Rego 2000/3000,thermostat,172,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp Rego 2000/3000,thermostat,172,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control Rego 2000/3000,thermostat,172,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp Rego 2000/3000,thermostat,172,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum Rego 2000/3000,thermostat,172,heatondelay,heat-on delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay Rego 2000/3000,thermostat,172,heatoffdelay,heat-off delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay Rego 2000/3000,thermostat,172,instantstart,instant start,uint (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart Rego 2000/3000,thermostat,172,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost Rego 2000/3000,thermostat,172,boosttime,boost time,uint (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime Comfort RF,thermostat,215,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Comfort RF,thermostat,215,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Comfort RF,thermostat,215,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime Comfort RF,thermostat,215,seltemp,selected room temperature,short (>=-15999<=15999),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp Comfort RF,thermostat,215,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Comfort RF,thermostat,215,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate Comfort RF,thermostat,215,mode,mode,enum [auto\|off], ,false,sensor.thermostat_hc1_mode,sensor.thermostat_hc1_mode Comfort RF,thermostat,215,modetype,mode type,enum [off\|on], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype Comfort RF,thermostat,215,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp CRF200S,thermostat,216,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode CRF200S,thermostat,216,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode CRF200S,thermostat,216,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime CRF200S,thermostat,216,seltemp,selected room temperature,short (>=-15999<=15999),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp CRF200S,thermostat,216,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp CRF200S,thermostat,216,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate CRF200S,thermostat,216,mode,mode,enum [auto\|off], ,false,sensor.thermostat_hc1_mode,sensor.thermostat_hc1_mode CRF200S,thermostat,216,modetype,mode type,enum [off\|on], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype CRF200S,thermostat,216,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp Comfort+2RF,thermostat,246,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Comfort+2RF,thermostat,246,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Comfort+2RF,thermostat,246,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime Comfort+2RF,thermostat,246,seltemp,selected room temperature,short (>=-15999<=15999),C,false,sensor.thermostat_hc1_selected_room_temperature,sensor.thermostat_hc1_seltemp Comfort+2RF,thermostat,246,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Comfort+2RF,thermostat,246,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate Comfort+2RF,thermostat,246,mode,mode,enum [auto\|off], ,false,sensor.thermostat_hc1_mode,sensor.thermostat_hc1_mode Comfort+2RF,thermostat,246,modetype,mode type,enum [off\|on], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype Comfort+2RF,thermostat,246,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Rego 3000/UI800/WSW196i/BC400,thermostat,253,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Rego 3000/UI800/WSW196i/BC400,thermostat,253,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime Rego 3000/UI800/WSW196i/BC400,thermostat,253,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset Rego 3000/UI800/WSW196i/BC400,thermostat,253,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry Rego 3000/UI800/WSW196i/BC400,thermostat,253,dampedoutdoortemp,damped outdoor temperature,short (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,floordrytemp,floor drying temperature,uint (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building Rego 3000/UI800/WSW196i/BC400,thermostat,253,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwsettemp,set temperature,uint (>=0<=254),C,true,number.thermostat_set_temperature,number.thermostat_wwsettemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwmode,mode,enum [off\|eco+\|eco\|comfort\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwmode,mode,enum [off\|eco+\|eco\|comfort\|auto], ,true,select.thermostat_wwc2_mode,select.thermostat_wwc2_wwmode Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwsettemplow,set low temperature,uint (>=0<=254),C,true,number.thermostat_set_low_temperature,number.thermostat_wwsettemplow Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_charge_duration,number.thermostat_wwchargeduration Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwextra1,circuit 1 extra,uint (>=0<=254),C,false,sensor.thermostat_circuit_1_extra,sensor.thermostat_wwextra1 Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_disinfection_time,number.thermostat_wwdisinfecttime Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_daily_heating,switch.thermostat_wwdailyheating Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_daily_heating_time,number.thermostat_wwdailyheattime Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwcircmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_wwc2_circulation_pump_mode,select.thermostat_wwc2_wwcircmode Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwchargeduration,charge duration,uint (>=0<=3810),minutes,true,number.thermostat_wwc2_charge_duration,number.thermostat_wwc2_wwchargeduration Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwcharge,charge,boolean, ,true,switch.thermostat_wwc2_charge,switch.thermostat_wwc2_wwcharge Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwextra2,circuit 2 extra,uint (>=0<=254),C,false,sensor.thermostat_wwc2_circuit_2_extra,sensor.thermostat_wwc2_wwextra2 Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_wwc2_disinfecting,switch.thermostat_wwc2_wwdisinfecting Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_wwc2_disinfection_day,select.thermostat_wwc2_wwdisinfectday Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdisinfecttime,disinfection time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_disinfection_time,number.thermostat_wwc2_wwdisinfecttime Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdailyheating,daily heating,boolean, ,true,switch.thermostat_wwc2_daily_heating,switch.thermostat_wwc2_wwdailyheating Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwdailyheattime,daily heating time,uint (>=0<=1431),minutes,true,number.thermostat_wwc2_daily_heating_time,number.thermostat_wwc2_wwdailyheattime Rego 3000/UI800/WSW196i/BC400,thermostat,253,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy Rego 3000/UI800/WSW196i/BC400,thermostat,253,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio Rego 3000/UI800/WSW196i/BC400,thermostat,253,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor Rego 3000/UI800/WSW196i/BC400,thermostat,253,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor Rego 3000/UI800/WSW196i/BC400,thermostat,253,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler Rego 3000/UI800/WSW196i/BC400,thermostat,253,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler Rego 3000/UI800/WSW196i/BC400,thermostat,253,pvenableww,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenableww Rego 3000/UI800/WSW196i/BC400,thermostat,253,pvraiseheat,raise heating with PV,int (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat Rego 3000/UI800/WSW196i/BC400,thermostat,253,pvlowercool,lower cooling with PV,int (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool Rego 3000/UI800/WSW196i/BC400,thermostat,253,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate Rego 3000/UI800/WSW196i/BC400,thermostat,253,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode Rego 3000/UI800/WSW196i/BC400,thermostat,253,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype Rego 3000/UI800/WSW196i/BC400,thermostat,253,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,manualtemp,manual temperature,uint (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,comforttemp,comfort temperature,uint (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,designtemp,design temperature,uint (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,offsettemp,offset temperature,int (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,roominfluence,room influence,uint (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence Rego 3000/UI800/WSW196i/BC400,thermostat,253,roominflfactor,room influence factor,uint (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor Rego 3000/UI800/WSW196i/BC400,thermostat,253,curroominfl,current room influence,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl Rego 3000/UI800/WSW196i/BC400,thermostat,253,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode Rego 3000/UI800/WSW196i/BC400,thermostat,253,nofrosttemp,nofrost temperature,int (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype Rego 3000/UI800/WSW196i/BC400,thermostat,253,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode Rego 3000/UI800/WSW196i/BC400,thermostat,253,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate Rego 3000/UI800/WSW196i/BC400,thermostat,253,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode Rego 3000/UI800/WSW196i/BC400,thermostat,253,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program Rego 3000/UI800/WSW196i/BC400,thermostat,253,tempautotemp,temporary set temperature automode,int (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,remoteseltemp,temporary set temperature from remote,int (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,fastheatup,fast heatup,uint (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup Rego 3000/UI800/WSW196i/BC400,thermostat,253,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization Rego 3000/UI800/WSW196i/BC400,thermostat,253,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode Rego 3000/UI800/WSW196i/BC400,thermostat,253,noreducetemp,no reduce below temperature,int (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,reducetemp,off/reduce switch temperature,int (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio Rego 3000/UI800/WSW196i/BC400,thermostat,253,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling Rego 3000/UI800/WSW196i/BC400,thermostat,253,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode Rego 3000/UI800/WSW196i/BC400,thermostat,253,dewoffset,dew point offset,uint (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset Rego 3000/UI800/WSW196i/BC400,thermostat,253,roomtempdiff,room temp difference,uint (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpminflowtemp,HP min. flow temp.,uint (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control Rego 3000/UI800/WSW196i/BC400,thermostat,253,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp Rego 3000/UI800/WSW196i/BC400,thermostat,253,remotehum,room humidity from remote,uint (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum Rego 3000/UI800/WSW196i/BC400,thermostat,253,heatondelay,heat-on delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay Rego 3000/UI800/WSW196i/BC400,thermostat,253,heatoffdelay,heat-off delay,uint (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay Rego 3000/UI800/WSW196i/BC400,thermostat,253,instantstart,instant start,uint (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart Rego 3000/UI800/WSW196i/BC400,thermostat,253,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost Rego 3000/UI800/WSW196i/BC400,thermostat,253,boosttime,boost time,uint (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime ES72/RC20,thermostat,66,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode ES72/RC20,thermostat,66,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode ES72/RC20,thermostat,66,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime ES72/RC20,thermostat,66,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp ES72/RC20,thermostat,66,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp ES72/RC20,thermostat,66,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp ES72/RC20,thermostat,66,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate ES72/RC20,thermostat,66,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode ES72/RC20,thermostat,66,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype ES72/RC20,thermostat,66,daytemp,day temperature,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp ES72/RC20,thermostat,66,nighttemp,night temperature,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp ES72/RC20,thermostat,66,program,program,enum [family\|morning\|evening\|am\|pm\|midday\|singles\|seniors], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program ES72/RC20,thermostat,66,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp ES72/RC20,thermostat,66,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp ES72/RC20,thermostat,66,tempautotemp,temporary set temperature automode,uint (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp ES72/RC20,thermostat,66,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype ES72/RC20,thermostat,66,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp ES72/RC20,thermostat,66,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode ES72/RC20,thermostat,66,remotetemp,room temperature from remote,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp ES73,thermostat,76,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode ES73,thermostat,76,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode ES73,thermostat,76,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime ES73,thermostat,76,display,display,enum [internal temperature\|internal setpoint\|external temperature\|burner temperature\|ww temperature\|functioning mode\|time\|date\|smoke temperature], ,true,select.thermostat_display,select.thermostat_display ES73,thermostat,76,language,language,enum [german\|dutch\|french\|italian], ,false,sensor.thermostat_language,sensor.thermostat_language ES73,thermostat,76,clockoffset,clock offset,int (>=-126<=126),seconds,true,number.thermostat_clock_offset,number.thermostat_clockoffset ES73,thermostat,76,intoffset,internal temperature offset,int (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset ES73,thermostat,76,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp ES73,thermostat,76,inttemp1,temperature sensor 1,short (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_1,sensor.thermostat_inttemp1 ES73,thermostat,76,inttemp2,temperature sensor 2,short (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_2,sensor.thermostat_inttemp2 ES73,thermostat,76,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping ES73,thermostat,76,dampedoutdoortemp,damped outdoor temperature,int (>=-126<=126),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp ES73,thermostat,76,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building ES73,thermostat,76,wwmode,mode,enum [off\|on\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode ES73,thermostat,76,wwcircmode,circulation pump mode,enum [off\|on\|auto], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode ES73,thermostat,76,wwprogmode,program,enum [std prog\|own prog], ,true,select.thermostat_program,select.thermostat_wwprogmode ES73,thermostat,76,wwcircprog,circulation program,enum [std prog\|own prog], ,true,select.thermostat_circulation_program,select.thermostat_wwcircprog ES73,thermostat,76,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting ES73,thermostat,76,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday ES73,thermostat,76,wwdisinfecthour,disinfection hour,uint (>=0<=23), ,true,number.thermostat_disinfection_hour,number.thermostat_wwdisinfecthour ES73,thermostat,76,wwmaxtemp,maximum temperature,uint (>=0<=254),C,true,number.thermostat_maximum_temperature,number.thermostat_wwmaxtemp ES73,thermostat,76,wwonetimekey,one time key function,boolean, ,true,switch.thermostat_one_time_key_function,switch.thermostat_wwonetimekey ES73,thermostat,76,wwswitchtime,program switchtime,string, ,true,sensor.thermostat_program_switchtime,sensor.thermostat_wwswitchtime ES73,thermostat,76,wwcircswitchtime,circulation program switchtime,string, ,true,sensor.thermostat_circulation_program_switchtime,sensor.thermostat_wwcircswitchtime ES73,thermostat,76,wwholidays,holiday dates,string, ,true,sensor.thermostat_holiday_dates,sensor.thermostat_wwholidays ES73,thermostat,76,wwvacations,vacation dates,string, ,true,sensor.thermostat_vacation_dates,sensor.thermostat_wwvacations ES73,thermostat,76,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp ES73,thermostat,76,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp ES73,thermostat,76,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate ES73,thermostat,76,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode ES73,thermostat,76,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype ES73,thermostat,76,daytemp,day temperature,uint (>=10<=30),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp ES73,thermostat,76,nighttemp,night temperature,uint (>=10<=30),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp ES73,thermostat,76,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp ES73,thermostat,76,offsettemp,offset temperature,int (>=-5<=5),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp ES73,thermostat,76,holidaytemp,holiday temperature,uint (>=5<=30),C,true,number.thermostat_hc1_holiday_temperature,number.thermostat_hc1_holidaytemp ES73,thermostat,76,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp ES73,thermostat,76,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp ES73,thermostat,76,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode ES73,thermostat,76,holidaymode,holiday mode,boolean, ,false,binary_sensor.thermostat_hc1_holiday_mode,binary_sensor.thermostat_hc1_holidaymode ES73,thermostat,76,nofrosttemp,nofrost temperature,int (>=-20<=10),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp ES73,thermostat,76,nofrostmode,nofrost mode,enum [off\|outdoor\|room], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode ES73,thermostat,76,roominfluence,room influence,uint (>=0<=10),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence ES73,thermostat,76,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp ES73,thermostat,76,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp ES73,thermostat,76,flowtempoffset,flow temperature offset for mixer,uint (>=0<=20),C,true,number.thermostat_hc1_flow_temperature_offset_for_mixer,number.thermostat_hc1_flowtempoffset ES73,thermostat,76,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype ES73,thermostat,76,reducemode,reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode ES73,thermostat,76,controlmode,control mode,enum [outdoor\|room], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode ES73,thermostat,76,control,control device,enum [off\|RC20\|RC3x], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control ES73,thermostat,76,holidays,holiday dates,string, ,true,sensor.thermostat_hc1_holiday_dates,sensor.thermostat_hc1_holidays ES73,thermostat,76,vacations,vacation dates,string, ,true,sensor.thermostat_hc1_vacation_dates,sensor.thermostat_hc1_vacations ES73,thermostat,76,program,program,enum [own 1\|family\|morning\|evening\|am\|pm\|midday\|singles\|seniors\|new\|own 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program ES73,thermostat,76,pause,pause time,uint (>=0<=99),hours,true,number.thermostat_hc1_pause_time,number.thermostat_hc1_pause ES73,thermostat,76,party,party time,uint (>=0<=99),hours,true,number.thermostat_hc1_party_time,number.thermostat_hc1_party ES73,thermostat,76,tempautotemp,temporary set temperature automode,uint (>=0<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp ES73,thermostat,76,noreducetemp,no reduce below temperature,int (>=-31<=10),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp ES73,thermostat,76,reducetemp,off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp ES73,thermostat,76,vacreducetemp,vacations off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_vacations_off/reduce_switch_temperature,number.thermostat_hc1_vacreducetemp ES73,thermostat,76,vacreducemode,vacations reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_vacations_reduce_mode,select.thermostat_hc1_vacreducemode ES73,thermostat,76,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp ES73,thermostat,76,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio ES73,thermostat,76,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization ES73,thermostat,76,switchtime1,own1 program switchtime,string, ,true,sensor.thermostat_hc1_own1_program_switchtime,sensor.thermostat_hc1_switchtime1 ES73,thermostat,76,switchtime2,own2 program switchtime,string, ,true,sensor.thermostat_hc1_own2_program_switchtime,sensor.thermostat_hc1_switchtime2 ES72/RC20,thermostat,113,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode ES72/RC20,thermostat,113,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode ES72/RC20,thermostat,113,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime ES72/RC20,thermostat,113,minexttemp,minimal external temperature,int (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp ES72/RC20,thermostat,113,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp ES72/RC20,thermostat,113,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp ES72/RC20,thermostat,113,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate ES72/RC20,thermostat,113,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode ES72/RC20,thermostat,113,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype ES72/RC20,thermostat,113,daytemp,day temperature,uint (>=0<=127),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp ES72/RC20,thermostat,113,nighttemp,night temperature,uint (>=0<=127),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp ES72/RC20,thermostat,113,program,program,enum [family\|morning\|evening\|am\|pm\|midday\|singles\|seniors], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program ES72/RC20,thermostat,113,minflowtemp,min flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp ES72/RC20,thermostat,113,maxflowtemp,max flow temperature,uint (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp ES72/RC20,thermostat,113,tempautotemp,temporary set temperature automode,uint (>=0<=127),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp ES72/RC20,thermostat,113,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype ES72/RC20,thermostat,113,summertemp,summer temperature,uint (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp ES72/RC20,thermostat,113,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode ES72/RC20,thermostat,113,remotetemp,room temperature from remote,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp ES79,thermostat,156,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode ES79,thermostat,156,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode ES79,thermostat,156,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime ES79,thermostat,156,intoffset,internal temperature offset,int (>=-5<=5),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset ES79,thermostat,156,minexttemp,minimal external temperature,int (>=-30<=0),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp ES79,thermostat,156,inttemp1,temperature sensor 1,short (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_1,sensor.thermostat_inttemp1 ES79,thermostat,156,inttemp2,temperature sensor 2,short (>=-3199<=3199),C,false,sensor.thermostat_temperature_sensor_2,sensor.thermostat_inttemp2 ES79,thermostat,156,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping ES79,thermostat,156,dampedoutdoortemp,damped outdoor temperature,int (>=-126<=126),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp ES79,thermostat,156,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building ES79,thermostat,156,wwmode,mode,enum [off\|on\|auto], ,true,select.thermostat_mode,select.thermostat_wwmode ES79,thermostat,156,wwcircmode,circulation pump mode,enum [off\|on\|auto], ,true,select.thermostat_circulation_pump_mode,select.thermostat_wwcircmode ES79,thermostat,156,wwprogmode,program,enum [std prog\|own prog], ,true,select.thermostat_program,select.thermostat_wwprogmode ES79,thermostat,156,wwcircprog,circulation program,enum [std prog\|own prog], ,true,select.thermostat_circulation_program,select.thermostat_wwcircprog ES79,thermostat,156,wwdisinfecting,disinfecting,boolean, ,true,switch.thermostat_disinfecting,switch.thermostat_wwdisinfecting ES79,thermostat,156,wwdisinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_disinfection_day,select.thermostat_wwdisinfectday ES79,thermostat,156,wwdisinfecthour,disinfection hour,uint (>=0<=23), ,true,number.thermostat_disinfection_hour,number.thermostat_wwdisinfecthour ES79,thermostat,156,wwmaxtemp,maximum temperature,uint (>=60<=80),C,true,number.thermostat_maximum_temperature,number.thermostat_wwmaxtemp ES79,thermostat,156,wwonetimekey,one time key function,boolean, ,true,switch.thermostat_one_time_key_function,switch.thermostat_wwonetimekey ES79,thermostat,156,wwswitchtime,program switchtime,string, ,true,sensor.thermostat_program_switchtime,sensor.thermostat_wwswitchtime ES79,thermostat,156,wwcircswitchtime,circulation program switchtime,string, ,true,sensor.thermostat_circulation_program_switchtime,sensor.thermostat_wwcircswitchtime ES79,thermostat,156,wwholidays,holiday dates,string, ,true,sensor.thermostat_holiday_dates,sensor.thermostat_wwholidays ES79,thermostat,156,wwvacations,vacation dates,string, ,true,sensor.thermostat_vacation_dates,sensor.thermostat_wwvacations ES79,thermostat,156,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp ES79,thermostat,156,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp ES79,thermostat,156,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate ES79,thermostat,156,mode,mode,enum [night\|day\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode ES79,thermostat,156,modetype,mode type,enum [night\|day], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype ES79,thermostat,156,daytemp,day temperature,uint (>=10<=30),C,true,number.thermostat_hc1_day_temperature,number.thermostat_hc1_daytemp ES79,thermostat,156,nighttemp,night temperature,uint (>=10<=30),C,true,number.thermostat_hc1_night_temperature,number.thermostat_hc1_nighttemp ES79,thermostat,156,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp ES79,thermostat,156,offsettemp,offset temperature,int (>=-5<=5),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp ES79,thermostat,156,holidaytemp,holiday temperature,uint (>=5<=30),C,true,number.thermostat_hc1_holiday_temperature,number.thermostat_hc1_holidaytemp ES79,thermostat,156,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp ES79,thermostat,156,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp ES79,thermostat,156,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode ES79,thermostat,156,holidaymode,holiday mode,boolean, ,false,binary_sensor.thermostat_hc1_holiday_mode,binary_sensor.thermostat_hc1_holidaymode ES79,thermostat,156,nofrosttemp,nofrost temperature,int (>=-20<=10),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp ES79,thermostat,156,nofrostmode,nofrost mode,enum [off\|outdoor\|room], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode ES79,thermostat,156,roominfluence,room influence,uint (>=0<=10),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence ES79,thermostat,156,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp ES79,thermostat,156,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp ES79,thermostat,156,flowtempoffset,flow temperature offset for mixer,uint (>=0<=20),C,true,number.thermostat_hc1_flow_temperature_offset_for_mixer,number.thermostat_hc1_flowtempoffset ES79,thermostat,156,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype ES79,thermostat,156,reducemode,reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode ES79,thermostat,156,controlmode,control mode,enum [outdoor\|room], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode ES79,thermostat,156,control,control device,enum [off\|RC20\|RC3x], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control ES79,thermostat,156,holidays,holiday dates,string, ,true,sensor.thermostat_hc1_holiday_dates,sensor.thermostat_hc1_holidays ES79,thermostat,156,vacations,vacation dates,string, ,true,sensor.thermostat_hc1_vacation_dates,sensor.thermostat_hc1_vacations ES79,thermostat,156,program,program,enum [own 1\|family\|morning\|evening\|am\|pm\|midday\|singles\|seniors\|new\|own 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program ES79,thermostat,156,pause,pause time,uint (>=0<=99),hours,true,number.thermostat_hc1_pause_time,number.thermostat_hc1_pause ES79,thermostat,156,party,party time,uint (>=0<=99),hours,true,number.thermostat_hc1_party_time,number.thermostat_hc1_party ES79,thermostat,156,tempautotemp,temporary set temperature automode,uint (>=0<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp ES79,thermostat,156,noreducetemp,no reduce below temperature,int (>=-31<=10),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp ES79,thermostat,156,reducetemp,off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp ES79,thermostat,156,vacreducetemp,vacations off/reduce switch temperature,int (>=-20<=10),C,true,number.thermostat_hc1_vacations_off/reduce_switch_temperature,number.thermostat_hc1_vacreducetemp ES79,thermostat,156,vacreducemode,vacations reduce mode,enum [nofrost\|reduce\|room\|outdoor], ,true,select.thermostat_hc1_vacations_reduce_mode,select.thermostat_hc1_vacreducemode ES79,thermostat,156,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp ES79,thermostat,156,wwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_wwprio ES79,thermostat,156,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization ES79,thermostat,156,switchtime1,own1 program switchtime,string, ,true,sensor.thermostat_hc1_own1_program_switchtime,sensor.thermostat_hc1_switchtime1 ES79,thermostat,156,switchtime2,own2 program switchtime,string, ,true,sensor.thermostat_hc1_own2_program_switchtime,sensor.thermostat_hc1_switchtime2 FW100,thermostat,105,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FW100,thermostat,105,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FW100,thermostat,105,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime FW100,thermostat,105,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy FW100,thermostat,105,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp FW100,thermostat,105,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio FW100,thermostat,105,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor FW100,thermostat,105,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor FW100,thermostat,105,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler FW100,thermostat,105,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler FW100,thermostat,105,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge FW100,thermostat,105,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp FW100,thermostat,105,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FW100,thermostat,105,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FW100,thermostat,105,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FW100,thermostat,105,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype FW100,thermostat,105,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp FW100,thermostat,105,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp FW100,thermostat,105,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FW100,thermostat,105,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FW100,thermostat,105,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program FW100,thermostat,105,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp FW100,thermostat,105,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp FW100,thermostat,105,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FW100,thermostat,105,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FW100,thermostat,105,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FW100,thermostat,105,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FW100,thermostat,105,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup FW100,thermostat,105,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp FW100,thermostat,105,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp FW100,thermostat,105,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FW100,thermostat,105,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence FW100,thermostat,105,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FW100,thermostat,105,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FW100,thermostat,105,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode FW200,thermostat,106,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FW200,thermostat,106,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FW200,thermostat,106,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime FW200,thermostat,106,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy FW200,thermostat,106,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp FW200,thermostat,106,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio FW200,thermostat,106,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor FW200,thermostat,106,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor FW200,thermostat,106,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler FW200,thermostat,106,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler FW200,thermostat,106,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge FW200,thermostat,106,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp FW200,thermostat,106,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FW200,thermostat,106,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FW200,thermostat,106,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FW200,thermostat,106,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype FW200,thermostat,106,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp FW200,thermostat,106,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp FW200,thermostat,106,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FW200,thermostat,106,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FW200,thermostat,106,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program FW200,thermostat,106,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp FW200,thermostat,106,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp FW200,thermostat,106,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FW200,thermostat,106,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FW200,thermostat,106,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FW200,thermostat,106,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FW200,thermostat,106,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup FW200,thermostat,106,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp FW200,thermostat,106,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp FW200,thermostat,106,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FW200,thermostat,106,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence FW200,thermostat,106,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FW200,thermostat,106,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FW200,thermostat,106,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode FR100,thermostat,107,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FR100,thermostat,107,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FR100,thermostat,107,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime FR100,thermostat,107,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy FR100,thermostat,107,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp FR100,thermostat,107,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio FR100,thermostat,107,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor FR100,thermostat,107,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor FR100,thermostat,107,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler FR100,thermostat,107,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler FR100,thermostat,107,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge FR100,thermostat,107,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp FR100,thermostat,107,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FR100,thermostat,107,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FR100,thermostat,107,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FR100,thermostat,107,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype FR100,thermostat,107,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp FR100,thermostat,107,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp FR100,thermostat,107,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FR100,thermostat,107,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FR100,thermostat,107,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program FR100,thermostat,107,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp FR100,thermostat,107,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp FR100,thermostat,107,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FR100,thermostat,107,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FR100,thermostat,107,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FR100,thermostat,107,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FR100,thermostat,107,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup FR100,thermostat,107,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp FR100,thermostat,107,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp FR100,thermostat,107,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FR100,thermostat,107,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence FR100,thermostat,107,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FR100,thermostat,107,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FR100,thermostat,107,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode FR110,thermostat,108,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FR110,thermostat,108,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FR110,thermostat,108,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime FR110,thermostat,108,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy FR110,thermostat,108,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp FR110,thermostat,108,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio FR110,thermostat,108,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor FR110,thermostat,108,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor FR110,thermostat,108,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler FR110,thermostat,108,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler FR110,thermostat,108,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge FR110,thermostat,108,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp FR110,thermostat,108,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FR110,thermostat,108,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FR110,thermostat,108,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FR110,thermostat,108,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype FR110,thermostat,108,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp FR110,thermostat,108,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp FR110,thermostat,108,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FR110,thermostat,108,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FR110,thermostat,108,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program FR110,thermostat,108,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp FR110,thermostat,108,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp FR110,thermostat,108,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FR110,thermostat,108,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FR110,thermostat,108,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FR110,thermostat,108,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FR110,thermostat,108,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup FR110,thermostat,108,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp FR110,thermostat,108,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp FR110,thermostat,108,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FR110,thermostat,108,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence FR110,thermostat,108,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FR110,thermostat,108,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FR110,thermostat,108,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode FB10,thermostat,109,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FB10,thermostat,109,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FB10,thermostat,109,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime FB10,thermostat,109,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy FB10,thermostat,109,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp FB10,thermostat,109,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio FB10,thermostat,109,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor FB10,thermostat,109,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor FB10,thermostat,109,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler FB10,thermostat,109,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler FB10,thermostat,109,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge FB10,thermostat,109,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp FB10,thermostat,109,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FB10,thermostat,109,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FB10,thermostat,109,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FB10,thermostat,109,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype FB10,thermostat,109,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp FB10,thermostat,109,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp FB10,thermostat,109,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FB10,thermostat,109,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FB10,thermostat,109,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program FB10,thermostat,109,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp FB10,thermostat,109,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp FB10,thermostat,109,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FB10,thermostat,109,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FB10,thermostat,109,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FB10,thermostat,109,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FB10,thermostat,109,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup FB10,thermostat,109,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp FB10,thermostat,109,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp FB10,thermostat,109,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FB10,thermostat,109,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence FB10,thermostat,109,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FB10,thermostat,109,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FB10,thermostat,109,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode FB100,thermostat,110,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FB100,thermostat,110,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FB100,thermostat,110,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime FB100,thermostat,110,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy FB100,thermostat,110,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp FB100,thermostat,110,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio FB100,thermostat,110,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor FB100,thermostat,110,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor FB100,thermostat,110,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler FB100,thermostat,110,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler FB100,thermostat,110,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge FB100,thermostat,110,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp FB100,thermostat,110,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FB100,thermostat,110,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FB100,thermostat,110,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FB100,thermostat,110,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype FB100,thermostat,110,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp FB100,thermostat,110,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp FB100,thermostat,110,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FB100,thermostat,110,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FB100,thermostat,110,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program FB100,thermostat,110,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp FB100,thermostat,110,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp FB100,thermostat,110,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FB100,thermostat,110,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FB100,thermostat,110,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FB100,thermostat,110,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FB100,thermostat,110,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup FB100,thermostat,110,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp FB100,thermostat,110,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp FB100,thermostat,110,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FB100,thermostat,110,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence FB100,thermostat,110,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FB100,thermostat,110,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FB100,thermostat,110,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode FR10,thermostat,111,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FR10,thermostat,111,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FR10,thermostat,111,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime FR10,thermostat,111,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy FR10,thermostat,111,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp FR10,thermostat,111,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio FR10,thermostat,111,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor FR10,thermostat,111,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor FR10,thermostat,111,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler FR10,thermostat,111,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler FR10,thermostat,111,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge FR10,thermostat,111,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp FR10,thermostat,111,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FR10,thermostat,111,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FR10,thermostat,111,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FR10,thermostat,111,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype FR10,thermostat,111,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp FR10,thermostat,111,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp FR10,thermostat,111,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FR10,thermostat,111,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FR10,thermostat,111,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program FR10,thermostat,111,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp FR10,thermostat,111,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp FR10,thermostat,111,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FR10,thermostat,111,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FR10,thermostat,111,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FR10,thermostat,111,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FR10,thermostat,111,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup FR10,thermostat,111,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp FR10,thermostat,111,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp FR10,thermostat,111,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FR10,thermostat,111,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence FR10,thermostat,111,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FR10,thermostat,111,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FR10,thermostat,111,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode FW500,thermostat,116,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FW500,thermostat,116,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FW500,thermostat,116,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime FW500,thermostat,116,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy FW500,thermostat,116,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp FW500,thermostat,116,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio FW500,thermostat,116,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor FW500,thermostat,116,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor FW500,thermostat,116,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler FW500,thermostat,116,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler FW500,thermostat,116,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge FW500,thermostat,116,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp FW500,thermostat,116,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FW500,thermostat,116,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FW500,thermostat,116,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FW500,thermostat,116,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype FW500,thermostat,116,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp FW500,thermostat,116,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp FW500,thermostat,116,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FW500,thermostat,116,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FW500,thermostat,116,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program FW500,thermostat,116,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp FW500,thermostat,116,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp FW500,thermostat,116,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FW500,thermostat,116,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FW500,thermostat,116,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FW500,thermostat,116,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FW500,thermostat,116,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup FW500,thermostat,116,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp FW500,thermostat,116,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp FW500,thermostat,116,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FW500,thermostat,116,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence FW500,thermostat,116,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FW500,thermostat,116,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FW500,thermostat,116,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode FR50,thermostat,147,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FR50,thermostat,147,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FR50,thermostat,147,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime FR50,thermostat,147,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy FR50,thermostat,147,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp FR50,thermostat,147,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio FR50,thermostat,147,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor FR50,thermostat,147,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor FR50,thermostat,147,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler FR50,thermostat,147,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler FR50,thermostat,147,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge FR50,thermostat,147,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp FR50,thermostat,147,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FR50,thermostat,147,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FR50,thermostat,147,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FR50,thermostat,147,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype FR50,thermostat,147,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp FR50,thermostat,147,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp FR50,thermostat,147,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FR50,thermostat,147,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FR50,thermostat,147,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program FR50,thermostat,147,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp FR50,thermostat,147,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp FR50,thermostat,147,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FR50,thermostat,147,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FR50,thermostat,147,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FR50,thermostat,147,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FR50,thermostat,147,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup FR50,thermostat,147,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp FR50,thermostat,147,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp FR50,thermostat,147,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FR50,thermostat,147,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence FR50,thermostat,147,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FR50,thermostat,147,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FR50,thermostat,147,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode FR120,thermostat,191,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FR120,thermostat,191,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FR120,thermostat,191,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime FR120,thermostat,191,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy FR120,thermostat,191,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp FR120,thermostat,191,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio FR120,thermostat,191,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor FR120,thermostat,191,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor FR120,thermostat,191,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler FR120,thermostat,191,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler FR120,thermostat,191,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge FR120,thermostat,191,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp FR120,thermostat,191,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FR120,thermostat,191,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FR120,thermostat,191,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FR120,thermostat,191,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype FR120,thermostat,191,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp FR120,thermostat,191,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp FR120,thermostat,191,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FR120,thermostat,191,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FR120,thermostat,191,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program FR120,thermostat,191,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp FR120,thermostat,191,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp FR120,thermostat,191,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FR120,thermostat,191,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FR120,thermostat,191,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FR120,thermostat,191,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FR120,thermostat,191,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup FR120,thermostat,191,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp FR120,thermostat,191,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp FR120,thermostat,191,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FR120,thermostat,191,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence FR120,thermostat,191,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FR120,thermostat,191,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FR120,thermostat,191,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode FW120,thermostat,192,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode FW120,thermostat,192,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode FW120,thermostat,192,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime FW120,thermostat,192,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy FW120,thermostat,192,switchovertemp,outside switchover temperature,int (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp FW120,thermostat,192,energycostratio,energy cost ratio,uint (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio FW120,thermostat,192,fossilefactor,fossile energy factor,uint (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor FW120,thermostat,192,electricfactor,electric energy factor,uint (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor FW120,thermostat,192,delayboiler,delay boiler support,uint (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler FW120,thermostat,192,tempdiffboiler,temp diff boiler support,uint (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler FW120,thermostat,192,wwcharge,charge,boolean, ,true,switch.thermostat_charge,switch.thermostat_wwcharge FW120,thermostat,192,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp FW120,thermostat,192,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp FW120,thermostat,192,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate FW120,thermostat,192,mode,mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode FW120,thermostat,192,modetype,mode type,enum [nofrost\|eco\|heat], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype FW120,thermostat,192,heattemp,heat temperature,uint (>=0<=127),C,true,number.thermostat_hc1_heat_temperature,number.thermostat_hc1_heattemp FW120,thermostat,192,ecotemp,eco temperature,uint (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp FW120,thermostat,192,nofrosttemp,nofrost temperature,int (>=-63<=63),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp FW120,thermostat,192,control,control device,enum [off\|FB10\|FB100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control FW120,thermostat,192,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program FW120,thermostat,192,remotetemp,room temperature from remote,short (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp FW120,thermostat,192,targetflowtemp,target flow temperature,uint (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp FW120,thermostat,192,summertemp,summer temperature,uint (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp FW120,thermostat,192,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor FW120,thermostat,192,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode FW120,thermostat,192,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization FW120,thermostat,192,heatup,heatup,enum [slow\|medium\|fast], ,true,select.thermostat_hc1_heatup,select.thermostat_hc1_heatup FW120,thermostat,192,minflowtemp,min flow temperature,uint (>=5<=70),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp FW120,thermostat,192,maxflowtemp,max flow temperature,uint (>=30<=90),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp FW120,thermostat,192,designtemp,design temperature,uint (>=30<=90),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp FW120,thermostat,192,roominfluence,room influence,enum [off\|intern\|extern\|auto], ,true,select.thermostat_hc1_room_influence,select.thermostat_hc1_roominfluence FW120,thermostat,192,roominflfactor,room influence factor,uint (>=0<=100),%,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor FW120,thermostat,192,heatingtype,heating type,enum [off\|heatingcurve\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype FW120,thermostat,192,controlmode,control mode,enum [off\|unmixed\|unmixed IPM\|mixed IPM], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode RT800,thermostat,3,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RT800,thermostat,3,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RT800,thermostat,3,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime RT800,thermostat,3,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RT800,thermostat,3,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RT800,thermostat,3,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate RC100H,thermostat,200,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC100H,thermostat,200,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC100H,thermostat,200,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime RC100H,thermostat,200,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp RC100H,thermostat,200,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp RC100H,thermostat,200,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate TR120RF/CR20RF,thermostat,249,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode TR120RF/CR20RF,thermostat,249,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode TR120RF/CR20RF,thermostat,249,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime TR120RF/CR20RF,thermostat,249,seltemp,selected room temperature,short (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp TR120RF/CR20RF,thermostat,249,currtemp,current room temperature,short (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp TR120RF/CR20RF,thermostat,249,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate MM10,mixer,69,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc MM10,mixer,69,valvestatus,mixing valve actuator (VC1),int (>=-100<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus MM10,mixer,69,flowsettemp,setpoint flow temperature,uint (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp MM10,mixer,69,pumpstatus,pump status (PC1),boolean, ,true,switch.mixer_hc1_pump_status_(PC1),switch.mixer_hc1_pumpstatus MM10,mixer,69,activated,activated,boolean, ,true,switch.mixer_hc1_activated,switch.mixer_hc1_activated MM10,mixer,69,valvesettime,time to set valve,uint (>=10<=120),seconds,true,number.mixer_hc1_time_to_set_valve,number.mixer_hc1_valvesettime IPM,mixer,100,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc IPM,mixer,100,valvestatus,mixing valve actuator (VC1),uint (>=0<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus IPM,mixer,100,flowsettemp,setpoint flow temperature,uint (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp IPM,mixer,100,pumpstatus,pump status (PC1),boolean, ,true,switch.mixer_hc1_pump_status_(PC1),switch.mixer_hc1_pumpstatus IPM,mixer,100,flowtempvf,flow temperature in header (T0/Vf),ushort (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_in_header_(T0/Vf),sensor.mixer_hc1_flowtempvf IPM,mixer,102,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc IPM,mixer,102,valvestatus,mixing valve actuator (VC1),uint (>=0<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus IPM,mixer,102,flowsettemp,setpoint flow temperature,uint (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp IPM,mixer,102,pumpstatus,pump status (PC1),boolean, ,true,switch.mixer_hc1_pump_status_(PC1),switch.mixer_hc1_pumpstatus IPM,mixer,102,flowtempvf,flow temperature in header (T0/Vf),ushort (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_in_header_(T0/Vf),sensor.mixer_hc1_flowtempvf MM50,mixer,159,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc MM50,mixer,159,valvestatus,mixing valve actuator (VC1),uint (>=0<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus MM50,mixer,159,flowsettemp,setpoint flow temperature,uint (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp MM50,mixer,159,pumpstatus,pump status (PC1),boolean, ,true,switch.mixer_hc1_pump_status_(PC1),switch.mixer_hc1_pumpstatus MM50,mixer,159,activated,activated,boolean, ,true,switch.mixer_hc1_activated,switch.mixer_hc1_activated MM50,mixer,159,valvesettime,time to set valve,uint (>=10<=600),seconds,true,number.mixer_hc1_time_to_set_valve,number.mixer_hc1_valvesettime MM50,mixer,159,flowtempoffset,flow temperature offset for mixer,uint (>=0<=20),K,true,number.mixer_hc1_flow_temperature_offset_for_mixer,number.mixer_hc1_flowtempoffset MM100,mixer,160,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.mixer_wwc1_flow_temperature_(TC1),sensor.mixer_wwc1_flowtemphc MM100,mixer,160,valvestatus,mixing valve actuator (VC1),uint (>=0<=100),%,false,sensor.mixer_wwc1_mixing_valve_actuator_(VC1),sensor.mixer_wwc1_valvestatus MM100,mixer,160,flowsettemp,setpoint flow temperature,uint (>=0<=254),C,true,number.mixer_wwc1_setpoint_flow_temperature,number.mixer_wwc1_flowsettemp MM100,mixer,160,pumpstatus,pump status (PC1),boolean, ,true,switch.mixer_wwc1_pump_status_(PC1),switch.mixer_wwc1_pumpstatus MM100,mixer,160,activated,activated,boolean, ,true,switch.mixer_wwc1_activated,switch.mixer_wwc1_activated MM100,mixer,160,valvesettime,time to set valve,uint (>=10<=600),seconds,true,number.mixer_wwc1_time_to_set_valve,number.mixer_wwc1_valvesettime MM100,mixer,160,flowtempoffset,flow temperature offset for mixer,uint (>=0<=20),K,true,number.mixer_wwc1_flow_temperature_offset_for_mixer,number.mixer_wwc1_flowtempoffset MM200,mixer,161,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc MM200,mixer,161,valvestatus,mixing valve actuator (VC1),uint (>=0<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus MM200,mixer,161,flowsettemp,setpoint flow temperature,uint (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp MM200,mixer,161,pumpstatus,pump status (PC1),boolean, ,true,switch.mixer_hc1_pump_status_(PC1),switch.mixer_hc1_pumpstatus MM200,mixer,161,activated,activated,boolean, ,true,switch.mixer_hc1_activated,switch.mixer_hc1_activated MM200,mixer,161,valvesettime,time to set valve,uint (>=10<=600),seconds,true,number.mixer_hc1_time_to_set_valve,number.mixer_hc1_valvesettime MM200,mixer,161,flowtempoffset,flow temperature offset for mixer,uint (>=0<=20),K,true,number.mixer_hc1_flow_temperature_offset_for_mixer,number.mixer_hc1_flowtempoffset MZ100,mixer,193,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc MZ100,mixer,193,valvestatus,mixing valve actuator (VC1),uint (>=0<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus MZ100,mixer,193,flowsettemp,setpoint flow temperature,uint (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp MZ100,mixer,193,pumpstatus,pump status (PC1),boolean, ,true,switch.mixer_hc1_pump_status_(PC1),switch.mixer_hc1_pumpstatus MZ100,mixer,193,activated,activated,boolean, ,true,switch.mixer_hc1_activated,switch.mixer_hc1_activated MZ100,mixer,193,valvesettime,time to set valve,uint (>=10<=600),seconds,true,number.mixer_hc1_time_to_set_valve,number.mixer_hc1_valvesettime MZ100,mixer,193,flowtempoffset,flow temperature offset for mixer,uint (>=0<=20),K,true,number.mixer_hc1_flow_temperature_offset_for_mixer,number.mixer_hc1_flowtempoffset SM10,solar,73,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp SM10,solar,73,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp SM10,solar,73,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump SM10,solar,73,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime SM10,solar,73,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp SM10,solar,73,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown SM10,solar,73,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated SM10,solar,73,solarpumpmod,pump modulation (PS1),uint (>=0<=100),%,false,sensor.solar_pump_modulation_(PS1),sensor.solar_solarpumpmod SM10,solar,73,pumpminmod,minimum pump modulation,uint (>=0<=100),%,true,number.solar_minimum_pump_modulation,number.solar_pumpminmod SM10,solar,73,turnondiff,pump turn on difference,uint (>=0<=254),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff SM10,solar,73,turnoffdiff,pump turn off difference,uint (>=0<=254),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff SM10,solar,73,solarpower,actual solar power,short (>=-31999<=31999),W,false,sensor.solar_actual_solar_power,sensor.solar_solarpower SM10,solar,73,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour SM10,solar,73,maxflow,maximum solar flow,uint (>=0<=25),l/min,true,number.solar_maximum_solar_flow,number.solar_maxflow SM10,solar,73,wwmintemp,minimum temperature,uint (>=0<=254),C,true,number.solar_minimum_temperature,number.solar_wwmintemp SM10,solar,73,solarenabled,solarmodule enabled,boolean, ,true,switch.solar_solarmodule_enabled,switch.solar_solarenabled ISM1,solar,101,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp ISM1,solar,101,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp ISM1,solar,101,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump ISM1,solar,101,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime ISM1,solar,101,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp ISM1,solar,101,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown ISM1,solar,101,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated ISM1,solar,101,cylmiddletemp,cylinder middle temperature (TS3),short (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp ISM1,solar,101,retheatassist,return temperature heat assistance (TS4),short (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist ISM1,solar,101,heatassistvalve,heat assistance valve (M1),boolean, ,false,binary_sensor.solar_heat_assistance_valve_(M1),binary_sensor.solar_heatassistvalve ISM1,solar,101,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour ISM2,solar,103,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp ISM2,solar,103,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp ISM2,solar,103,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump ISM2,solar,103,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime ISM2,solar,103,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp ISM2,solar,103,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown ISM2,solar,103,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated ISM2,solar,103,cylmiddletemp,cylinder middle temperature (TS3),short (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp ISM2,solar,103,retheatassist,return temperature heat assistance (TS4),short (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist ISM2,solar,103,heatassistvalve,heat assistance valve (M1),boolean, ,false,binary_sensor.solar_heat_assistance_valve_(M1),binary_sensor.solar_heatassistvalve ISM2,solar,103,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour SM50,solar,162,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp SM50,solar,162,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp SM50,solar,162,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump SM50,solar,162,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime SM50,solar,162,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp SM50,solar,162,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown SM50,solar,162,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated SM50,solar,162,solarpumpmod,pump modulation (PS1),uint (>=0<=100),%,false,sensor.solar_pump_modulation_(PS1),sensor.solar_solarpumpmod SM50,solar,162,pumpminmod,minimum pump modulation,uint (>=0<=100),%,true,number.solar_minimum_pump_modulation,number.solar_pumpminmod SM50,solar,162,turnondiff,pump turn on difference,uint (>=0<=25),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff SM50,solar,162,turnoffdiff,pump turn off difference,uint (>=0<=25),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff SM50,solar,162,collector2temp,collector 2 temperature (TS7),short (>=-3199<=3199),C,false,sensor.solar_collector_2_temperature_(TS7),sensor.solar_collector2temp SM50,solar,162,cylmiddletemp,cylinder middle temperature (TS3),short (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp SM50,solar,162,retheatassist,return temperature heat assistance (TS4),short (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist SM50,solar,162,heatassistvalve,heat assistance valve (M1),boolean, ,false,binary_sensor.solar_heat_assistance_valve_(M1),binary_sensor.solar_heatassistvalve SM50,solar,162,heatassistpower,heat assistance valve power (M1),uint (>=0<=100),%,false,sensor.solar_heat_assistance_valve_power_(M1),sensor.solar_heatassistpower SM50,solar,162,solarpump2,pump 2 (PS4),boolean, ,false,binary_sensor.solar_pump_2_(PS4),binary_sensor.solar_solarpump2 SM50,solar,162,solarpump2mod,pump 2 modulation (PS4),uint (>=0<=100),%,false,sensor.solar_pump_2_modulation_(PS4),sensor.solar_solarpump2mod SM50,solar,162,cyl2bottomtemp,second cylinder bottom temperature (TS5),short (>=-3199<=3199),C,false,sensor.solar_second_cylinder_bottom_temperature_(TS5),sensor.solar_cyl2bottomtemp SM50,solar,162,heatexchangertemp,heat exchanger temperature (TS6),short (>=-3199<=3199),C,false,sensor.solar_heat_exchanger_temperature_(TS6),sensor.solar_heatexchangertemp SM50,solar,162,cylpumpmod,cylinder pump modulation (PS5),uint (>=0<=100),%,false,sensor.solar_cylinder_pump_modulation_(PS5),sensor.solar_cylpumpmod SM50,solar,162,valvestatus,valve status,boolean, ,false,binary_sensor.solar_valve_status,binary_sensor.solar_valvestatus SM50,solar,162,vs1status,valve status VS1,boolean, ,false,binary_sensor.solar_valve_status_VS1,binary_sensor.solar_vs1status SM50,solar,162,collectormaxtemp,maximum collector temperature,uint (>=0<=254),C,true,number.solar_maximum_collector_temperature,number.solar_collectormaxtemp SM50,solar,162,collectormintemp,minimum collector temperature,uint (>=0<=254),C,true,number.solar_minimum_collector_temperature,number.solar_collectormintemp SM50,solar,162,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour SM50,solar,162,energytoday,total energy today,ulong (>=0<=16777213),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday SM50,solar,162,energytotal,total energy,ulong (>=0<=1677721),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal SM50,solar,162,pump2worktime,pump 2 working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_2_working_time,sensor.solar_pump2worktime SM50,solar,162,m1worktime,differential control working time,time (>=0<=16777213),minutes,false,sensor.solar_differential_control_working_time,sensor.solar_m1worktime SM50,solar,162,heattransfersystem,heattransfer system,boolean, ,true,switch.solar_heattransfer_system,switch.solar_heattransfersystem SM50,solar,162,externalcyl,external cylinder,boolean, ,true,switch.solar_external_cylinder,switch.solar_externalcyl SM50,solar,162,thermaldisinfect,thermal disinfection,boolean, ,true,switch.solar_thermal_disinfection,switch.solar_thermaldisinfect SM50,solar,162,heatmetering,heatmetering,boolean, ,true,switch.solar_heatmetering,switch.solar_heatmetering SM50,solar,162,activated,activated,boolean, ,true,switch.solar_activated,switch.solar_activated SM50,solar,162,solarpumpmode,pump mode,enum [constant\|pwm\|analog], ,true,select.solar_pump_mode,select.solar_solarpumpmode SM50,solar,162,pumpkick,pump kick,boolean, ,true,switch.solar_pump_kick,switch.solar_pumpkick SM50,solar,162,plainwatermode,plain water mode,boolean, ,true,switch.solar_plain_water_mode,switch.solar_plainwatermode SM50,solar,162,doublematchflow,doublematchflow,boolean, ,true,switch.solar_doublematchflow,switch.solar_doublematchflow SM50,solar,162,pump2minmod,minimum pump 2 modulation,uint (>=0<=100),%,true,number.solar_minimum_pump_2_modulation,number.solar_pump2minmod SM50,solar,162,turnondiff2,pump 2 turn on difference,uint (>=0<=25),C,true,number.solar_pump_2_turn_on_difference,number.solar_turnondiff2 SM50,solar,162,turnoffdiff2,pump 2 turn off difference,uint (>=0<=25),C,true,number.solar_pump_2_turn_off_difference,number.solar_turnoffdiff2 SM50,solar,162,pump2kick,pump kick 2,boolean, ,true,switch.solar_pump_kick_2,switch.solar_pump2kick SM50,solar,162,climatezone,climate zone,uint (>=0<=254), ,true,number.solar_climate_zone,number.solar_climatezone SM50,solar,162,collector1area,collector 1 area,ushort (>=0<=3199),m²,true,number.solar_collector_1_area,number.solar_collector1area SM50,solar,162,collector1type,collector 1 type,enum [flat\|vacuum], ,true,select.solar_collector_1_type,select.solar_collector1type SM50,solar,162,collector2area,collector 2 area,ushort (>=0<=3199),m²,true,number.solar_collector_2_area,number.solar_collector2area SM50,solar,162,collector2type,collector 2 type,enum [flat\|vacuum], ,true,select.solar_collector_2_type,select.solar_collector2type SM50,solar,162,cylpriority,cylinder priority,enum [cyl 1\|cyl 2], ,true,select.solar_cylinder_priority,select.solar_cylpriority SM50,solar,162,heatcntflowtemp,heat counter flow temperature,ushort (>=0<=3199),C,false,sensor.solar_heat_counter_flow_temperature,sensor.solar_heatcntflowtemp SM50,solar,162,heatcntrettemp,heat counter return temperature,ushort (>=0<=3199),C,false,sensor.solar_heat_counter_return_temperature,sensor.solar_heatcntrettemp SM50,solar,162,heatcnt,heat counter impulses,uint (>=0<=254), ,false,sensor.solar_heat_counter_impulses,sensor.solar_heatcnt SM50,solar,162,swapflowtemp,swap flow temperature (TS14),ushort (>=0<=3199),C,false,sensor.solar_swap_flow_temperature_(TS14),sensor.solar_swapflowtemp SM50,solar,162,swaprettemp,swap return temperature (TS15),ushort (>=0<=3199),C,false,sensor.solar_swap_return_temperature_(TS15),sensor.solar_swaprettemp SM100/MS100,solar,163,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp SM100/MS100,solar,163,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp SM100/MS100,solar,163,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump SM100/MS100,solar,163,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime SM100/MS100,solar,163,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp SM100/MS100,solar,163,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown SM100/MS100,solar,163,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated SM100/MS100,solar,163,solarpumpmod,pump modulation (PS1),uint (>=0<=100),%,false,sensor.solar_pump_modulation_(PS1),sensor.solar_solarpumpmod SM100/MS100,solar,163,pumpminmod,minimum pump modulation,uint (>=0<=100),%,true,number.solar_minimum_pump_modulation,number.solar_pumpminmod SM100/MS100,solar,163,turnondiff,pump turn on difference,uint (>=0<=25),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff SM100/MS100,solar,163,turnoffdiff,pump turn off difference,uint (>=0<=25),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff SM100/MS100,solar,163,collector2temp,collector 2 temperature (TS7),short (>=-3199<=3199),C,false,sensor.solar_collector_2_temperature_(TS7),sensor.solar_collector2temp SM100/MS100,solar,163,cylmiddletemp,cylinder middle temperature (TS3),short (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp SM100/MS100,solar,163,retheatassist,return temperature heat assistance (TS4),short (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist SM100/MS100,solar,163,heatassistvalve,heat assistance valve (M1),boolean, ,false,binary_sensor.solar_heat_assistance_valve_(M1),binary_sensor.solar_heatassistvalve SM100/MS100,solar,163,heatassistpower,heat assistance valve power (M1),uint (>=0<=100),%,false,sensor.solar_heat_assistance_valve_power_(M1),sensor.solar_heatassistpower SM100/MS100,solar,163,solarpump2,pump 2 (PS4),boolean, ,false,binary_sensor.solar_pump_2_(PS4),binary_sensor.solar_solarpump2 SM100/MS100,solar,163,solarpump2mod,pump 2 modulation (PS4),uint (>=0<=100),%,false,sensor.solar_pump_2_modulation_(PS4),sensor.solar_solarpump2mod SM100/MS100,solar,163,cyl2bottomtemp,second cylinder bottom temperature (TS5),short (>=-3199<=3199),C,false,sensor.solar_second_cylinder_bottom_temperature_(TS5),sensor.solar_cyl2bottomtemp SM100/MS100,solar,163,heatexchangertemp,heat exchanger temperature (TS6),short (>=-3199<=3199),C,false,sensor.solar_heat_exchanger_temperature_(TS6),sensor.solar_heatexchangertemp SM100/MS100,solar,163,cylpumpmod,cylinder pump modulation (PS5),uint (>=0<=100),%,false,sensor.solar_cylinder_pump_modulation_(PS5),sensor.solar_cylpumpmod SM100/MS100,solar,163,valvestatus,valve status,boolean, ,false,binary_sensor.solar_valve_status,binary_sensor.solar_valvestatus SM100/MS100,solar,163,vs1status,valve status VS1,boolean, ,false,binary_sensor.solar_valve_status_VS1,binary_sensor.solar_vs1status SM100/MS100,solar,163,collectormaxtemp,maximum collector temperature,uint (>=0<=254),C,true,number.solar_maximum_collector_temperature,number.solar_collectormaxtemp SM100/MS100,solar,163,collectormintemp,minimum collector temperature,uint (>=0<=254),C,true,number.solar_minimum_collector_temperature,number.solar_collectormintemp SM100/MS100,solar,163,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour SM100/MS100,solar,163,energytoday,total energy today,ulong (>=0<=16777213),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday SM100/MS100,solar,163,energytotal,total energy,ulong (>=0<=1677721),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal SM100/MS100,solar,163,pump2worktime,pump 2 working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_2_working_time,sensor.solar_pump2worktime SM100/MS100,solar,163,m1worktime,differential control working time,time (>=0<=16777213),minutes,false,sensor.solar_differential_control_working_time,sensor.solar_m1worktime SM100/MS100,solar,163,heattransfersystem,heattransfer system,boolean, ,true,switch.solar_heattransfer_system,switch.solar_heattransfersystem SM100/MS100,solar,163,externalcyl,external cylinder,boolean, ,true,switch.solar_external_cylinder,switch.solar_externalcyl SM100/MS100,solar,163,thermaldisinfect,thermal disinfection,boolean, ,true,switch.solar_thermal_disinfection,switch.solar_thermaldisinfect SM100/MS100,solar,163,heatmetering,heatmetering,boolean, ,true,switch.solar_heatmetering,switch.solar_heatmetering SM100/MS100,solar,163,activated,activated,boolean, ,true,switch.solar_activated,switch.solar_activated SM100/MS100,solar,163,solarpumpmode,pump mode,enum [constant\|pwm\|analog], ,true,select.solar_pump_mode,select.solar_solarpumpmode SM100/MS100,solar,163,pumpkick,pump kick,boolean, ,true,switch.solar_pump_kick,switch.solar_pumpkick SM100/MS100,solar,163,plainwatermode,plain water mode,boolean, ,true,switch.solar_plain_water_mode,switch.solar_plainwatermode SM100/MS100,solar,163,doublematchflow,doublematchflow,boolean, ,true,switch.solar_doublematchflow,switch.solar_doublematchflow SM100/MS100,solar,163,pump2minmod,minimum pump 2 modulation,uint (>=0<=100),%,true,number.solar_minimum_pump_2_modulation,number.solar_pump2minmod SM100/MS100,solar,163,turnondiff2,pump 2 turn on difference,uint (>=0<=25),C,true,number.solar_pump_2_turn_on_difference,number.solar_turnondiff2 SM100/MS100,solar,163,turnoffdiff2,pump 2 turn off difference,uint (>=0<=25),C,true,number.solar_pump_2_turn_off_difference,number.solar_turnoffdiff2 SM100/MS100,solar,163,pump2kick,pump kick 2,boolean, ,true,switch.solar_pump_kick_2,switch.solar_pump2kick SM100/MS100,solar,163,climatezone,climate zone,uint (>=0<=254), ,true,number.solar_climate_zone,number.solar_climatezone SM100/MS100,solar,163,collector1area,collector 1 area,ushort (>=0<=3199),m²,true,number.solar_collector_1_area,number.solar_collector1area SM100/MS100,solar,163,collector1type,collector 1 type,enum [flat\|vacuum], ,true,select.solar_collector_1_type,select.solar_collector1type SM100/MS100,solar,163,collector2area,collector 2 area,ushort (>=0<=3199),m²,true,number.solar_collector_2_area,number.solar_collector2area SM100/MS100,solar,163,collector2type,collector 2 type,enum [flat\|vacuum], ,true,select.solar_collector_2_type,select.solar_collector2type SM100/MS100,solar,163,cylpriority,cylinder priority,enum [cyl 1\|cyl 2], ,true,select.solar_cylinder_priority,select.solar_cylpriority SM100/MS100,solar,163,heatcntflowtemp,heat counter flow temperature,ushort (>=0<=3199),C,false,sensor.solar_heat_counter_flow_temperature,sensor.solar_heatcntflowtemp SM100/MS100,solar,163,heatcntrettemp,heat counter return temperature,ushort (>=0<=3199),C,false,sensor.solar_heat_counter_return_temperature,sensor.solar_heatcntrettemp SM100/MS100,solar,163,heatcnt,heat counter impulses,uint (>=0<=254), ,false,sensor.solar_heat_counter_impulses,sensor.solar_heatcnt SM100/MS100,solar,163,swapflowtemp,swap flow temperature (TS14),ushort (>=0<=3199),C,false,sensor.solar_swap_flow_temperature_(TS14),sensor.solar_swapflowtemp SM100/MS100,solar,163,swaprettemp,swap return temperature (TS15),ushort (>=0<=3199),C,false,sensor.solar_swap_return_temperature_(TS15),sensor.solar_swaprettemp SM200/MS200,solar,164,collectortemp,collector temperature (TS1),short (>=-3199<=3199),C,false,sensor.solar_collector_temperature_(TS1),sensor.solar_collectortemp SM200/MS200,solar,164,cylbottomtemp,cylinder bottom temperature (TS2),short (>=-3199<=3199),C,false,sensor.solar_cylinder_bottom_temperature_(TS2),sensor.solar_cylbottomtemp SM200/MS200,solar,164,solarpump,pump (PS1),boolean, ,false,binary_sensor.solar_pump_(PS1),binary_sensor.solar_solarpump SM200/MS200,solar,164,pumpworktime,pump working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_working_time,sensor.solar_pumpworktime SM200/MS200,solar,164,cylmaxtemp,maximum cylinder temperature,uint (>=0<=254),C,true,number.solar_maximum_cylinder_temperature,number.solar_cylmaxtemp SM200/MS200,solar,164,collectorshutdown,collector shutdown,boolean, ,false,binary_sensor.solar_collector_shutdown,binary_sensor.solar_collectorshutdown SM200/MS200,solar,164,cylheated,cyl heated,boolean, ,false,binary_sensor.solar_cyl_heated,binary_sensor.solar_cylheated SM200/MS200,solar,164,solarpumpmod,pump modulation (PS1),uint (>=0<=100),%,false,sensor.solar_pump_modulation_(PS1),sensor.solar_solarpumpmod SM200/MS200,solar,164,pumpminmod,minimum pump modulation,uint (>=0<=100),%,true,number.solar_minimum_pump_modulation,number.solar_pumpminmod SM200/MS200,solar,164,turnondiff,pump turn on difference,uint (>=0<=25),C,true,number.solar_pump_turn_on_difference,number.solar_turnondiff SM200/MS200,solar,164,turnoffdiff,pump turn off difference,uint (>=0<=25),C,true,number.solar_pump_turn_off_difference,number.solar_turnoffdiff SM200/MS200,solar,164,collector2temp,collector 2 temperature (TS7),short (>=-3199<=3199),C,false,sensor.solar_collector_2_temperature_(TS7),sensor.solar_collector2temp SM200/MS200,solar,164,cylmiddletemp,cylinder middle temperature (TS3),short (>=-3199<=3199),C,false,sensor.solar_cylinder_middle_temperature_(TS3),sensor.solar_cylmiddletemp SM200/MS200,solar,164,retheatassist,return temperature heat assistance (TS4),short (>=-3199<=3199),C,false,sensor.solar_return_temperature_heat_assistance_(TS4),sensor.solar_retheatassist SM200/MS200,solar,164,heatassistvalve,heat assistance valve (M1),boolean, ,false,binary_sensor.solar_heat_assistance_valve_(M1),binary_sensor.solar_heatassistvalve SM200/MS200,solar,164,heatassistpower,heat assistance valve power (M1),uint (>=0<=100),%,false,sensor.solar_heat_assistance_valve_power_(M1),sensor.solar_heatassistpower SM200/MS200,solar,164,solarpump2,pump 2 (PS4),boolean, ,false,binary_sensor.solar_pump_2_(PS4),binary_sensor.solar_solarpump2 SM200/MS200,solar,164,solarpump2mod,pump 2 modulation (PS4),uint (>=0<=100),%,false,sensor.solar_pump_2_modulation_(PS4),sensor.solar_solarpump2mod SM200/MS200,solar,164,cyl2bottomtemp,second cylinder bottom temperature (TS5),short (>=-3199<=3199),C,false,sensor.solar_second_cylinder_bottom_temperature_(TS5),sensor.solar_cyl2bottomtemp SM200/MS200,solar,164,heatexchangertemp,heat exchanger temperature (TS6),short (>=-3199<=3199),C,false,sensor.solar_heat_exchanger_temperature_(TS6),sensor.solar_heatexchangertemp SM200/MS200,solar,164,cylpumpmod,cylinder pump modulation (PS5),uint (>=0<=100),%,false,sensor.solar_cylinder_pump_modulation_(PS5),sensor.solar_cylpumpmod SM200/MS200,solar,164,valvestatus,valve status,boolean, ,false,binary_sensor.solar_valve_status,binary_sensor.solar_valvestatus SM200/MS200,solar,164,vs1status,valve status VS1,boolean, ,false,binary_sensor.solar_valve_status_VS1,binary_sensor.solar_vs1status SM200/MS200,solar,164,collectormaxtemp,maximum collector temperature,uint (>=0<=254),C,true,number.solar_maximum_collector_temperature,number.solar_collectormaxtemp SM200/MS200,solar,164,collectormintemp,minimum collector temperature,uint (>=0<=254),C,true,number.solar_minimum_collector_temperature,number.solar_collectormintemp SM200/MS200,solar,164,energylasthour,energy last hour,ulong (>=0<=1677721),Wh,false,sensor.solar_energy_last_hour,sensor.solar_energylasthour SM200/MS200,solar,164,energytoday,total energy today,ulong (>=0<=16777213),Wh,false,sensor.solar_total_energy_today,sensor.solar_energytoday SM200/MS200,solar,164,energytotal,total energy,ulong (>=0<=1677721),kWh,false,sensor.solar_total_energy,sensor.solar_energytotal SM200/MS200,solar,164,pump2worktime,pump 2 working time,time (>=0<=16777213),minutes,false,sensor.solar_pump_2_working_time,sensor.solar_pump2worktime SM200/MS200,solar,164,m1worktime,differential control working time,time (>=0<=16777213),minutes,false,sensor.solar_differential_control_working_time,sensor.solar_m1worktime SM200/MS200,solar,164,heattransfersystem,heattransfer system,boolean, ,true,switch.solar_heattransfer_system,switch.solar_heattransfersystem SM200/MS200,solar,164,externalcyl,external cylinder,boolean, ,true,switch.solar_external_cylinder,switch.solar_externalcyl SM200/MS200,solar,164,thermaldisinfect,thermal disinfection,boolean, ,true,switch.solar_thermal_disinfection,switch.solar_thermaldisinfect SM200/MS200,solar,164,heatmetering,heatmetering,boolean, ,true,switch.solar_heatmetering,switch.solar_heatmetering SM200/MS200,solar,164,activated,activated,boolean, ,true,switch.solar_activated,switch.solar_activated SM200/MS200,solar,164,solarpumpmode,pump mode,enum [constant\|pwm\|analog], ,true,select.solar_pump_mode,select.solar_solarpumpmode SM200/MS200,solar,164,pumpkick,pump kick,boolean, ,true,switch.solar_pump_kick,switch.solar_pumpkick SM200/MS200,solar,164,plainwatermode,plain water mode,boolean, ,true,switch.solar_plain_water_mode,switch.solar_plainwatermode SM200/MS200,solar,164,doublematchflow,doublematchflow,boolean, ,true,switch.solar_doublematchflow,switch.solar_doublematchflow SM200/MS200,solar,164,pump2minmod,minimum pump 2 modulation,uint (>=0<=100),%,true,number.solar_minimum_pump_2_modulation,number.solar_pump2minmod SM200/MS200,solar,164,turnondiff2,pump 2 turn on difference,uint (>=0<=25),C,true,number.solar_pump_2_turn_on_difference,number.solar_turnondiff2 SM200/MS200,solar,164,turnoffdiff2,pump 2 turn off difference,uint (>=0<=25),C,true,number.solar_pump_2_turn_off_difference,number.solar_turnoffdiff2 SM200/MS200,solar,164,pump2kick,pump kick 2,boolean, ,true,switch.solar_pump_kick_2,switch.solar_pump2kick SM200/MS200,solar,164,climatezone,climate zone,uint (>=0<=254), ,true,number.solar_climate_zone,number.solar_climatezone SM200/MS200,solar,164,collector1area,collector 1 area,ushort (>=0<=3199),m²,true,number.solar_collector_1_area,number.solar_collector1area SM200/MS200,solar,164,collector1type,collector 1 type,enum [flat\|vacuum], ,true,select.solar_collector_1_type,select.solar_collector1type SM200/MS200,solar,164,collector2area,collector 2 area,ushort (>=0<=3199),m²,true,number.solar_collector_2_area,number.solar_collector2area SM200/MS200,solar,164,collector2type,collector 2 type,enum [flat\|vacuum], ,true,select.solar_collector_2_type,select.solar_collector2type SM200/MS200,solar,164,cylpriority,cylinder priority,enum [cyl 1\|cyl 2], ,true,select.solar_cylinder_priority,select.solar_cylpriority SM200/MS200,solar,164,heatcntflowtemp,heat counter flow temperature,ushort (>=0<=3199),C,false,sensor.solar_heat_counter_flow_temperature,sensor.solar_heatcntflowtemp SM200/MS200,solar,164,heatcntrettemp,heat counter return temperature,ushort (>=0<=3199),C,false,sensor.solar_heat_counter_return_temperature,sensor.solar_heatcntrettemp SM200/MS200,solar,164,heatcnt,heat counter impulses,uint (>=0<=254), ,false,sensor.solar_heat_counter_impulses,sensor.solar_heatcnt SM200/MS200,solar,164,swapflowtemp,swap flow temperature (TS14),ushort (>=0<=3199),C,false,sensor.solar_swap_flow_temperature_(TS14),sensor.solar_swapflowtemp SM200/MS200,solar,164,swaprettemp,swap return temperature (TS15),ushort (>=0<=3199),C,false,sensor.solar_swap_return_temperature_(TS15),sensor.solar_swaprettemp HP Module,heatpump,252,airhumidity,relative air humidity,uint (>=0<=100),%,false,sensor.heatpump_relative_air_humidity,sensor.heatpump_airhumidity HP Module,heatpump,252,dewtemperature,dew point temperature,uint (>=0<=254),C,false,sensor.heatpump_dew_point_temperature,sensor.heatpump_dewtemperature HP Module,heatpump,252,curflowtemp,current flow temperature,short (>=-3199<=3199),C,false,sensor.heatpump_current_flow_temperature,sensor.heatpump_curflowtemp HP Module,heatpump,252,rettemp,return temperature,short (>=-3199<=3199),C,false,sensor.heatpump_return_temperature,sensor.heatpump_rettemp HP Module,heatpump,252,sysrettemp,system return temperature,short (>=-3199<=3199),C,false,sensor.heatpump_system_return_temperature,sensor.heatpump_sysrettemp HP Module,heatpump,252,hpta4,drain pan temp (TA4),short (>=-3199<=3199),C,false,sensor.heatpump_drain_pan_temp_(TA4),sensor.heatpump_hpta4 HP Module,heatpump,252,hptr1,compressor temperature (TR1),short (>=-3199<=3199),C,false,sensor.heatpump_compressor_temperature_(TR1),sensor.heatpump_hptr1 HP Module,heatpump,252,hptr3,refrigerant temperature liquid side (condenser output) (TR3),short (>=-3199<=3199),C,false,sensor.heatpump_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.heatpump_hptr3 HP Module,heatpump,252,hptr4,evaporator inlet temperature (TR4),short (>=-3199<=3199),C,false,sensor.heatpump_evaporator_inlet_temperature_(TR4),sensor.heatpump_hptr4 HP Module,heatpump,252,hptr5,compressor inlet temperature (TR5),short (>=-3199<=3199),C,false,sensor.heatpump_compressor_inlet_temperature_(TR5),sensor.heatpump_hptr5 HP Module,heatpump,252,hptr6,compressor outlet temperature (TR6),short (>=-3199<=3199),C,false,sensor.heatpump_compressor_outlet_temperature_(TR6),sensor.heatpump_hptr6 HP Module,heatpump,252,hptl2,air inlet temperature (TL2),short (>=-3199<=3199),C,false,sensor.heatpump_air_inlet_temperature_(TL2),sensor.heatpump_hptl2 HP Module,heatpump,252,hppl1,low pressure side temperature (PL1),short (>=-3199<=3199),C,false,sensor.heatpump_low_pressure_side_temperature_(PL1),sensor.heatpump_hppl1 HP Module,heatpump,252,hpph1,high pressure side temperature (PH1),short (>=-3199<=3199),C,false,sensor.heatpump_high_pressure_side_temperature_(PH1),sensor.heatpump_hpph1 HP Module,heatpump,252,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.heatpump_heating_pump_modulation,sensor.heatpump_heatingpumpmod HP Module,heatpump,252,hpcompspd,compressor speed,uint (>=0<=100),%,false,sensor.heatpump_compressor_speed,sensor.heatpump_hpcompspd HP Module,heatpump,252,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump prefered\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy HP Module,heatpump,252,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode HP Module,heatpump,252,lownoisestart,low noise starttime,uint (>=0<=23), ,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart HP Module,heatpump,252,lownoisestop,low noise stoptime,uint (>=0<=23), ,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop HP Module,heatpump,252,hybriddhw,hybrid DHW,enum [eco\|high comfort], ,true,select.heatpump_hybrid_DHW,select.heatpump_hybriddhw HP Module,heatpump,252,energypricegas,energy price gas,uint (>=0<=254), ,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas HP Module,heatpump,252,energypriceel,energy price electric,uint (>=0<=254), ,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel HP Module,heatpump,252,energyfeedpv,feed in PV,uint (>=0<=254), ,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv HP Module,heatpump,252,switchovertemp,outside switchover temperature,int (>=-126<=126), ,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp HP Module,heatpump,252,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode HP Module,heatpump,252,heatpumpoutput,heatpump output,uint (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput HP Module,heatpump,252,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit HP Module,heatpump,252,compstartmod,compressor start modulation,uint (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod HP Module,heatpump,252,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan HP Module,heatpump,252,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable HP Module,heatpump,252,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal HP Module,heatpump,252,nrgww,energy,ulong (>=0<=167772),kWh,false,sensor.heatpump_energy,sensor.heatpump_nrgww HP Module,heatpump,252,nrgheat,energy heating,ulong (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat HP Module,heatpump,252,metertotal,meter total,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal HP Module,heatpump,252,metercomp,meter compressor,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp HP Module,heatpump,252,metereheat,meter e-heater,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat HP Module,heatpump,252,meterheat,meter heating,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat HP Module,heatpump,252,meterww,meter,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter,sensor.heatpump_meterww Hybrid Manager HM200,heatpump,248,airhumidity,relative air humidity,uint (>=0<=100),%,false,sensor.heatpump_relative_air_humidity,sensor.heatpump_airhumidity Hybrid Manager HM200,heatpump,248,dewtemperature,dew point temperature,uint (>=0<=254),C,false,sensor.heatpump_dew_point_temperature,sensor.heatpump_dewtemperature Hybrid Manager HM200,heatpump,248,curflowtemp,current flow temperature,short (>=-3199<=3199),C,false,sensor.heatpump_current_flow_temperature,sensor.heatpump_curflowtemp Hybrid Manager HM200,heatpump,248,rettemp,return temperature,short (>=-3199<=3199),C,false,sensor.heatpump_return_temperature,sensor.heatpump_rettemp Hybrid Manager HM200,heatpump,248,sysrettemp,system return temperature,short (>=-3199<=3199),C,false,sensor.heatpump_system_return_temperature,sensor.heatpump_sysrettemp Hybrid Manager HM200,heatpump,248,hpta4,drain pan temp (TA4),short (>=-3199<=3199),C,false,sensor.heatpump_drain_pan_temp_(TA4),sensor.heatpump_hpta4 Hybrid Manager HM200,heatpump,248,hptr1,compressor temperature (TR1),short (>=-3199<=3199),C,false,sensor.heatpump_compressor_temperature_(TR1),sensor.heatpump_hptr1 Hybrid Manager HM200,heatpump,248,hptr3,refrigerant temperature liquid side (condenser output) (TR3),short (>=-3199<=3199),C,false,sensor.heatpump_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.heatpump_hptr3 Hybrid Manager HM200,heatpump,248,hptr4,evaporator inlet temperature (TR4),short (>=-3199<=3199),C,false,sensor.heatpump_evaporator_inlet_temperature_(TR4),sensor.heatpump_hptr4 Hybrid Manager HM200,heatpump,248,hptr5,compressor inlet temperature (TR5),short (>=-3199<=3199),C,false,sensor.heatpump_compressor_inlet_temperature_(TR5),sensor.heatpump_hptr5 Hybrid Manager HM200,heatpump,248,hptr6,compressor outlet temperature (TR6),short (>=-3199<=3199),C,false,sensor.heatpump_compressor_outlet_temperature_(TR6),sensor.heatpump_hptr6 Hybrid Manager HM200,heatpump,248,hptl2,air inlet temperature (TL2),short (>=-3199<=3199),C,false,sensor.heatpump_air_inlet_temperature_(TL2),sensor.heatpump_hptl2 Hybrid Manager HM200,heatpump,248,hppl1,low pressure side temperature (PL1),short (>=-3199<=3199),C,false,sensor.heatpump_low_pressure_side_temperature_(PL1),sensor.heatpump_hppl1 Hybrid Manager HM200,heatpump,248,hpph1,high pressure side temperature (PH1),short (>=-3199<=3199),C,false,sensor.heatpump_high_pressure_side_temperature_(PH1),sensor.heatpump_hpph1 Hybrid Manager HM200,heatpump,248,heatingpumpmod,heating pump modulation,uint (>=0<=100),%,false,sensor.heatpump_heating_pump_modulation,sensor.heatpump_heatingpumpmod Hybrid Manager HM200,heatpump,248,hpcompspd,compressor speed,uint (>=0<=100),%,false,sensor.heatpump_compressor_speed,sensor.heatpump_hpcompspd Hybrid Manager HM200,heatpump,248,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump prefered\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy Hybrid Manager HM200,heatpump,248,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode Hybrid Manager HM200,heatpump,248,lownoisestart,low noise starttime,uint (>=0<=23), ,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart Hybrid Manager HM200,heatpump,248,lownoisestop,low noise stoptime,uint (>=0<=23), ,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop Hybrid Manager HM200,heatpump,248,hybriddhw,hybrid DHW,enum [eco\|high comfort], ,true,select.heatpump_hybrid_DHW,select.heatpump_hybriddhw Hybrid Manager HM200,heatpump,248,energypricegas,energy price gas,uint (>=0<=254), ,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas Hybrid Manager HM200,heatpump,248,energypriceel,energy price electric,uint (>=0<=254), ,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel Hybrid Manager HM200,heatpump,248,energyfeedpv,feed in PV,uint (>=0<=254), ,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv Hybrid Manager HM200,heatpump,248,switchovertemp,outside switchover temperature,int (>=-126<=126), ,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp Hybrid Manager HM200,heatpump,248,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode Hybrid Manager HM200,heatpump,248,heatpumpoutput,heatpump output,uint (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput Hybrid Manager HM200,heatpump,248,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit Hybrid Manager HM200,heatpump,248,compstartmod,compressor start modulation,uint (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod Hybrid Manager HM200,heatpump,248,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan Hybrid Manager HM200,heatpump,248,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable Hybrid Manager HM200,heatpump,248,nrgtotal,total energy,ulong (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal Hybrid Manager HM200,heatpump,248,nrgww,energy,ulong (>=0<=167772),kWh,false,sensor.heatpump_energy,sensor.heatpump_nrgww Hybrid Manager HM200,heatpump,248,nrgheat,energy heating,ulong (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat Hybrid Manager HM200,heatpump,248,metertotal,meter total,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal Hybrid Manager HM200,heatpump,248,metercomp,meter compressor,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp Hybrid Manager HM200,heatpump,248,metereheat,meter e-heater,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat Hybrid Manager HM200,heatpump,248,meterheat,meter heating,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat Hybrid Manager HM200,heatpump,248,meterww,meter,ulong (>=0<=167772),kWh,false,sensor.heatpump_meter,sensor.heatpump_meterww WM10,switch,71,activated,activated,boolean, ,false,binary_sensor.switch_activated,binary_sensor.switch_activated WM10,switch,71,flowtemphc,flow temperature (TC1),ushort (>=0<=3199),C,false,sensor.switch_flow_temperature_(TC1),sensor.switch_flowtemphc WM10,switch,71,status,status,int (>=-126<=126), ,false,sensor.switch_status,sensor.switch_status Rego 3000,controller,240,datetime,date/time,string, ,false,sensor.controller_date/time,sensor.controller_datetime EM10,alert,74,setflowtemp,set flow temperature,uint (>=0<=254),C,false,sensor.alert_set_flow_temperature,sensor.alert_setflowtemp EM10,alert,74,setburnpow,burner set power,uint (>=0<=100),%,false,sensor.alert_burner_set_power,sensor.alert_setburnpow EM10/EM100,extension,243,flowtempvf,flow temperature in header (T0/Vf),short (>=-3199<=3199),C,false,sensor.extension_flow_temperature_in_header_(T0/Vf),sensor.extension_flowtempvf EM10/EM100,extension,243,input,input,uint (>=0<=25),V,false,sensor.extension_input,sensor.extension_input EM10/EM100,extension,243,outpow,output IO1,uint (>=0<=100),%,false,sensor.extension_output_IO1,sensor.extension_outpow EM10/EM100,extension,243,setpower,request power,uint (>=0<=100),%,false,sensor.extension_request_power,sensor.extension_setpower EM10/EM100,extension,243,setpoint,set temp.,uint (>=0<=254),C,false,sensor.extension_set_temp.,sensor.extension_setpoint EM10/EM100,extension,243,minv,min volt.,uint (>=0<=25),V,true,number.extension_min_volt.,number.extension_minv EM10/EM100,extension,243,maxv,max volt.,uint (>=0<=25),V,true,number.extension_max_volt.,number.extension_maxv EM10/EM100,extension,243,mint,min temp.,uint (>=0<=254),C,true,number.extension_min_temp.,number.extension_mint EM10/EM100,extension,243,maxt,max temp.,uint (>=0<=254),C,true,number.extension_max_temp.,number.extension_maxt EM10/EM100,extension,243,mode,mode,uint (>=0<=254), ,false,sensor.extension_mode,sensor.extension_mode T1RF,extension,220,flowtempvf,flow temperature in header (T0/Vf),short (>=-3199<=3199),C,false,sensor.extension_flow_temperature_in_header_(T0/Vf),sensor.extension_flowtempvf T1RF,extension,220,input,input,uint (>=0<=25),V,false,sensor.extension_input,sensor.extension_input T1RF,extension,220,outpow,output IO1,uint (>=0<=100),%,false,sensor.extension_output_IO1,sensor.extension_outpow T1RF,extension,220,setpower,request power,uint (>=0<=100),%,false,sensor.extension_request_power,sensor.extension_setpower T1RF,extension,220,setpoint,set temp.,uint (>=0<=254),C,false,sensor.extension_set_temp.,sensor.extension_setpoint T1RF,extension,220,minv,min volt.,uint (>=0<=25),V,true,number.extension_min_volt.,number.extension_minv T1RF,extension,220,maxv,max volt.,uint (>=0<=25),V,true,number.extension_max_volt.,number.extension_maxv T1RF,extension,220,mint,min temp.,uint (>=0<=254),C,true,number.extension_min_temp.,number.extension_mint T1RF,extension,220,maxt,max temp.,uint (>=0<=254),C,true,number.extension_max_temp.,number.extension_maxt T1RF,extension,220,mode,mode,uint (>=0<=254), ,false,sensor.extension_mode,sensor.extension_mode Logavent HRV176,ventilation,231,outfresh,outdoor fresh air,short (>=-3199<=3199),C,false,sensor.ventilation_outdoor_fresh_air,sensor.ventilation_outfresh Logavent HRV176,ventilation,231,infresh,indoor fresh air,short (>=-3199<=3199),C,false,sensor.ventilation_indoor_fresh_air,sensor.ventilation_infresh Logavent HRV176,ventilation,231,outexhaust,outdoor exhaust air,short (>=-3199<=3199),C,false,sensor.ventilation_outdoor_exhaust_air,sensor.ventilation_outexhaust Logavent HRV176,ventilation,231,inexhaust,indoor exhaust air,short (>=-3199<=3199),C,false,sensor.ventilation_indoor_exhaust_air,sensor.ventilation_inexhaust Logavent HRV176,ventilation,231,ventinspeed,in blower speed,uint (>=0<=100),%,false,sensor.ventilation_in_blower_speed,sensor.ventilation_ventinspeed Logavent HRV176,ventilation,231,ventoutspeed,out blower speed,uint (>=0<=100),%,false,sensor.ventilation_out_blower_speed,sensor.ventilation_ventoutspeed Logavent HRV176,ventilation,231,ventmode,ventilation mode,enum [auto\|off\|L1\|L2\|L3\|L4\|demand\|sleep\|intense\|bypass\|party\|fireplace], ,true,select.ventilation_ventilation_mode,select.ventilation_ventmode Logavent HRV176,ventilation,231,airquality,air quality (voc),ushort (>=0<=31999), ,false,sensor.ventilation_air_quality_(voc),sensor.ventilation_airquality Logavent HRV176,ventilation,231,airhumidity,relative air humidity,uint (>=0<=100),%,false,sensor.ventilation_relative_air_humidity,sensor.ventilation_airhumidity MP100,pool,204,pooltemp,pool temperature,short (>=-3199<=3199),C,false,sensor.pool_pool_temperature,sensor.pool_pooltemp MP100,pool,204,poolshuntstatus,pool shunt status opening/closing,enum [stopped\|opening\|closing\|open\|close], ,false,sensor.pool_pool_shunt_status_opening/closing,sensor.pool_poolshuntstatus MP100,pool,204,poolshunt,pool shunt open/close (0% = pool / 100% = heat),uint (>=0<=100),%,false,sensor.pool_pool_shunt_open/close_(0%_=_pool_/_100%_=_heat),sensor.pool_poolshunt