* EMS-ESP - https://github.com/emsesp/EMS-ESP
|
|
* Copyright 2020 Paul Derbyshire
|
|
*
|
|
* This program is free software: you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License as published by
|
|
* the Free Software Foundation, either version 3 of the License, or
|
|
* (at your option) any later version.
|
|
*
|
|
* This program is distributed in the hope that it will be useful,
|
|
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
* GNU General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU General Public License
|
|
* along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
*/
|
|
|
|
#include "boiler.h"
|
|
|
|
namespace emsesp {
|
|
|
|
REGISTER_FACTORY(Boiler, EMSdevice::DeviceType::BOILER)
|
|
|
|
uuid::log::Logger Boiler::logger_{F_(boiler), uuid::log::Facility::CONSOLE};
|
|
|
|
Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const std::string & version, const std::string & name, uint8_t flags, uint8_t brand)
|
|
: EMSdevice(device_type, device_id, product_id, version, name, flags, brand) {
|
|
LOG_DEBUG(F("Adding new Boiler with device ID 0x%02X"), device_id);
|
|
|
|
// cascaded heatingsources, only some values per individual heatsource (hs)
|
|
if (device_id != EMSdevice::EMS_DEVICE_ID_BOILER) {
|
|
uint8_t hs = device_id - EMSdevice::EMS_DEVICE_ID_BOILER_1; // heating source id, count from 0
|
|
// Runtime of each heatingsource in 0x06DC, ff
|
|
register_telegram_type(0x6DC + hs, F("CascadeMessage"), false, MAKE_PF_CB(process_CascadeMessage));
|
|
register_device_value(TAG_HS1 + hs, &burnWorkMin_, DeviceValueType::TIME, nullptr, F("burnWorkMin"), F("total burner operating time"), DeviceValueUOM::MINUTES);
|
|
// selBurnpower in D2 and E4
|
|
// register_telegram_type(0xD2, F("CascadePowerMessage"), false, MAKE_PF_CB(process_CascadePowerMessage));
|
|
// individual Flowtemps and powervalues for each heatingsource in E4
|
|
register_telegram_type(0xE4, F("UBAMonitorFastPlus"), false, MAKE_PF_CB(process_UBAMonitorFastPlus));
|
|
register_device_value(TAG_HS1 + hs, &selFlowTemp_, DeviceValueType::UINT, nullptr, F("selFlowTemp"), F("selected flow temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_HS1 + hs, &selBurnPow_, DeviceValueType::UINT, nullptr, F("selBurnPow"), F("burner selected max power"), DeviceValueUOM::PERCENT);
|
|
register_device_value(TAG_HS1 + hs, &curFlowTemp_, DeviceValueType::USHORT, FL_(div10), F("curFlowTemp"), F("current flow temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_HS1 + hs, &curBurnPow_, DeviceValueType::UINT, nullptr, F("curBurnPow"), F("burner current power"), DeviceValueUOM::PERCENT);
|
|
return;
|
|
}
|
|
// register values for master boiler/cascade module
|
|
|
|
reserve_telgram_functions(25); // reserve some space for the telegram registries, to avoid memory fragmentation
|
|
|
|
// the telegram handlers...
|
|
register_telegram_type(0x10, F("UBAErrorMessage1"), false, MAKE_PF_CB(process_UBAErrorMessage));
|
|
register_telegram_type(0x11, F("UBAErrorMessage2"), false, MAKE_PF_CB(process_UBAErrorMessage));
|
|
register_telegram_type(0x14, F("UBATotalUptime"), true, MAKE_PF_CB(process_UBATotalUptime));
|
|
register_telegram_type(0x15, F("UBAMaintenanceData"), false, MAKE_PF_CB(process_UBAMaintenanceData));
|
|
register_telegram_type(0x16, F("UBAParameters"), true, MAKE_PF_CB(process_UBAParameters));
|
|
register_telegram_type(0x18, F("UBAMonitorFast"), false, MAKE_PF_CB(process_UBAMonitorFast));
|
|
register_telegram_type(0x19, F("UBAMonitorSlow"), true, MAKE_PF_CB(process_UBAMonitorSlow));
|
|
register_telegram_type(0x1A, F("UBASetPoints"), false, MAKE_PF_CB(process_UBASetPoints));
|
|
register_telegram_type(0x1C, F("UBAMaintenanceStatus"), false, MAKE_PF_CB(process_UBAMaintenanceStatus));
|
|
register_telegram_type(0x26, F("UBASettingsWW"), true, MAKE_PF_CB(process_UBASettingsWW));
|
|
register_telegram_type(0x2A, F("MC10Status"), false, MAKE_PF_CB(process_MC10Status));
|
|
register_telegram_type(0x33, F("UBAParameterWW"), true, MAKE_PF_CB(process_UBAParameterWW));
|
|
register_telegram_type(0x34, F("UBAMonitorWW"), false, MAKE_PF_CB(process_UBAMonitorWW));
|
|
register_telegram_type(0x35, F("UBAFlags"), false, MAKE_PF_CB(process_UBAFlags));
|
|
register_telegram_type(0xD1, F("UBAOutdoorTemp"), false, MAKE_PF_CB(process_UBAOutdoorTemp));
|
|
register_telegram_type(0xE3, F("UBAMonitorSlowPlus"), false, MAKE_PF_CB(process_UBAMonitorSlowPlus2));
|
|
register_telegram_type(0xE4, F("UBAMonitorFastPlus"), false, MAKE_PF_CB(process_UBAMonitorFastPlus));
|
|
register_telegram_type(0xE5, F("UBAMonitorSlowPlus"), false, MAKE_PF_CB(process_UBAMonitorSlowPlus));
|
|
register_telegram_type(0xE6, F("UBAParametersPlus"), true, MAKE_PF_CB(process_UBAParametersPlus));
|
|
register_telegram_type(0xE9, F("UBADHWStatus"), false, MAKE_PF_CB(process_UBADHWStatus));
|
|
register_telegram_type(0xEA, F("UBAParameterWWPlus"), true, MAKE_PF_CB(process_UBAParameterWWPlus));
|
|
register_telegram_type(0x494, F("UBAEnergySupplied"), false, MAKE_PF_CB(process_UBAEnergySupplied));
|
|
register_telegram_type(0x495, F("UBAInformation"), false, MAKE_PF_CB(process_UBAInformation));
|
|
|
|
// MQTT commands for boiler topic
|
|
register_mqtt_cmd(F("comfort"), MAKE_CF_CB(set_warmwater_mode));
|
|
register_mqtt_cmd(F("wwactivated"), MAKE_CF_CB(set_warmwater_activated));
|
|
register_mqtt_cmd(F("wwtapactivated"), MAKE_CF_CB(set_tapwarmwater_activated));
|
|
register_mqtt_cmd(F("wwflowtempoffset"), MAKE_CF_CB(set_wWFlowTempOffset));
|
|
register_mqtt_cmd(F("wwmaxpower"), MAKE_CF_CB(set_warmwater_maxpower));
|
|
register_mqtt_cmd(F("wwonetime"), MAKE_CF_CB(set_warmwater_onetime));
|
|
register_mqtt_cmd(F("wwcircpump"), MAKE_CF_CB(set_warmwater_circulation_pump));
|
|
register_mqtt_cmd(F("wwcirculation"), MAKE_CF_CB(set_warmwater_circulation));
|
|
register_mqtt_cmd(F("wwcircmode"), MAKE_CF_CB(set_warmwater_circulation_mode));
|
|
register_mqtt_cmd(F("flowtemp"), MAKE_CF_CB(set_flow_temp));
|
|
register_mqtt_cmd(F("wwsettemp"), MAKE_CF_CB(set_warmwater_temp));
|
|
register_mqtt_cmd(F("heatingactivated"), MAKE_CF_CB(set_heating_activated));
|
|
register_mqtt_cmd(F("heatingtemp"), MAKE_CF_CB(set_heating_temp));
|
|
register_mqtt_cmd(F("burnmaxpower"), MAKE_CF_CB(set_max_power));
|
|
register_mqtt_cmd(F("burnminpower"), MAKE_CF_CB(set_min_power));
|
|
register_mqtt_cmd(F("boilhyston"), MAKE_CF_CB(set_hyst_on));
|
|
register_mqtt_cmd(F("boilhystoff"), MAKE_CF_CB(set_hyst_off));
|
|
register_mqtt_cmd(F("burnperiod"), MAKE_CF_CB(set_burn_period));
|
|
register_mqtt_cmd(F("pumpdelay"), MAKE_CF_CB(set_pump_delay));
|
|
register_mqtt_cmd(F("maintenance"), MAKE_CF_CB(set_maintenance));
|
|
register_mqtt_cmd(F("pumpmodmax"), MAKE_CF_CB(set_max_pump));
|
|
register_mqtt_cmd(F("pumpmodmin"), MAKE_CF_CB(set_min_pump));
|
|
|
|
// add values
|
|
reserve_device_values(50);
|
|
|
|
// main - boiler_data topic
|
|
register_device_value(TAG_BOILER_DATA, &id_, DeviceValueType::UINT, nullptr, F("id"), nullptr); // empty full name to prevent being shown in web or console
|
|
id_ = product_id;
|
|
|
|
register_device_value(TAG_BOILER_DATA, &heatingActive_, DeviceValueType::BOOL, nullptr, F("heatingActive"), F("heating active"));
|
|
register_device_value(TAG_BOILER_DATA, &tapwaterActive_, DeviceValueType::BOOL, nullptr, F("tapwaterActive"), F("warm water active"));
|
|
register_device_value(TAG_BOILER_DATA, &selFlowTemp_, DeviceValueType::UINT, nullptr, F("selFlowTemp"), F("selected flow temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA, &selBurnPow_, DeviceValueType::UINT, nullptr, F("selBurnPow"), F("burner selected max power"), DeviceValueUOM::PERCENT);
|
|
register_device_value(TAG_BOILER_DATA, &heatingPumpMod_, DeviceValueType::UINT, nullptr, F("heatingPumpMod"), F("heating pump modulation"), DeviceValueUOM::PERCENT);
|
|
register_device_value(TAG_BOILER_DATA, &heatingPump2Mod_, DeviceValueType::UINT, nullptr, F("heatingPump2Mod"), F("heating pump 2 modulation"), DeviceValueUOM::PERCENT);
|
|
register_device_value(TAG_BOILER_DATA, &outdoorTemp_, DeviceValueType::SHORT, FL_(div10), F("outdoorTemp"), F("outside temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA, &curFlowTemp_, DeviceValueType::USHORT, FL_(div10), F("curFlowTemp"), F("current flow temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA, &retTemp_, DeviceValueType::USHORT, FL_(div10), F("retTemp"), F("return temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA, &switchTemp_, DeviceValueType::USHORT, FL_(div10), F("switchTemp"), F("mixing switch temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA, &sysPress_, DeviceValueType::UINT, FL_(div10), F("sysPress"), F("system pressure"), DeviceValueUOM::BAR);
|
|
register_device_value(TAG_BOILER_DATA, &boilTemp_, DeviceValueType::USHORT, FL_(div10), F("boilTemp"), F("max boiler temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA, &exhaustTemp_, DeviceValueType::USHORT, FL_(div10), F("exhaustTemp"), F("exhaust temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA, &burnGas_, DeviceValueType::BOOL, nullptr, F("burnGas"), F("gas"));
|
|
register_device_value(TAG_BOILER_DATA, &flameCurr_, DeviceValueType::USHORT, FL_(div10), F("flameCurr"), F("flame current"), DeviceValueUOM::UA);
|
|
register_device_value(TAG_BOILER_DATA, &heatingPump_, DeviceValueType::BOOL, nullptr, F("heatingPump"), F("heating pump"), DeviceValueUOM::PUMP);
|
|
register_device_value(TAG_BOILER_DATA, &fanWork_, DeviceValueType::BOOL, nullptr, F("fanWork"), F("fan"));
|
|
register_device_value(TAG_BOILER_DATA, &ignWork_, DeviceValueType::BOOL, nullptr, F("ignWork"), F("ignition"));
|
|
register_device_value(TAG_BOILER_DATA, &heatingActivated_, DeviceValueType::BOOL, nullptr, F("heatingActivated"), F("heating activated"));
|
|
register_device_value(TAG_BOILER_DATA, &heatingTemp_, DeviceValueType::UINT, nullptr, F("heatingTemp"), F("heating temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA, &pumpModMax_, DeviceValueType::UINT, nullptr, F("pumpModMax"), F("burner pump max power"), DeviceValueUOM::PERCENT);
|
|
register_device_value(TAG_BOILER_DATA, &pumpModMin_, DeviceValueType::UINT, nullptr, F("pumpModMin"), F("burner pump min power"), DeviceValueUOM::PERCENT);
|
|
register_device_value(TAG_BOILER_DATA, &pumpDelay_, DeviceValueType::UINT, nullptr, F("pumpDelay"), F("pump delay"), DeviceValueUOM::MINUTES);
|
|
register_device_value(TAG_BOILER_DATA, &burnMinPeriod_, DeviceValueType::UINT, nullptr, F("burnMinPeriod"), F("burner min period"), DeviceValueUOM::MINUTES);
|
|
register_device_value(TAG_BOILER_DATA, &burnMinPower_, DeviceValueType::UINT, nullptr, F("burnMinPower"), F("burner min power"), DeviceValueUOM::PERCENT);
|
|
register_device_value(TAG_BOILER_DATA, &burnMaxPower_, DeviceValueType::UINT, nullptr, F("burnMaxPower"), F("burner max power"), DeviceValueUOM::PERCENT);
|
|
register_device_value(TAG_BOILER_DATA, &boilHystOn_, DeviceValueType::INT, nullptr, F("boilHystOn"), F("hysteresis on temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA, &boilHystOff_, DeviceValueType::INT, nullptr, F("boilHystOff"), F("hysteresis off temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA, &setFlowTemp_, DeviceValueType::UINT, nullptr, F("setFlowTemp"), F("set flow temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA, &setBurnPow_, DeviceValueType::UINT, nullptr, F("setBurnPow"), F("burner set power"), DeviceValueUOM::PERCENT);
|
|
register_device_value(TAG_BOILER_DATA, &curBurnPow_, DeviceValueType::UINT, nullptr, F("curBurnPow"), F("burner current power"), DeviceValueUOM::PERCENT);
|
|
register_device_value(TAG_BOILER_DATA, &burnStarts_, DeviceValueType::ULONG, nullptr, F("burnStarts"), F("burner # starts"));
|
|
register_device_value(TAG_BOILER_DATA, &burnWorkMin_, DeviceValueType::TIME, nullptr, F("burnWorkMin"), F("total burner operating time"), DeviceValueUOM::MINUTES);
|
|
register_device_value(TAG_BOILER_DATA, &heatWorkMin_, DeviceValueType::TIME, nullptr, F("heatWorkMin"), F("total heat operating time"), DeviceValueUOM::MINUTES);
|
|
register_device_value(TAG_BOILER_DATA, &UBAuptime_, DeviceValueType::TIME, nullptr, F("UBAuptime"), F("total UBA operating time"), DeviceValueUOM::MINUTES);
|
|
register_device_value(TAG_BOILER_DATA, &lastCode_, DeviceValueType::TEXT, nullptr, F("lastCode"), F("last error code"));
|
|
register_device_value(TAG_BOILER_DATA, &serviceCode_, DeviceValueType::TEXT, nullptr, F("serviceCode"), F("service code"));
|
|
register_device_value(TAG_BOILER_DATA, &serviceCodeNumber_, DeviceValueType::USHORT, nullptr, F("serviceCodeNumber"), F("service code number"));
|
|
|
|
// info
|
|
register_device_value(TAG_BOILER_DATA, &upTimeControl_, DeviceValueType::TIME, FL_(div60), F("upTimeControl"), F("operating time total heat"), DeviceValueUOM::MINUTES);
|
|
register_device_value(TAG_BOILER_DATA, &upTimeCompHeating_, DeviceValueType::TIME, FL_(div60), F("upTimeCompHeating"), F("operating time compressor heating"), DeviceValueUOM::MINUTES);
|
|
register_device_value(TAG_BOILER_DATA, &upTimeCompCooling_, DeviceValueType::TIME, FL_(div60), F("upTimeCompCooling"), F("operating time compressor cooling"), DeviceValueUOM::MINUTES);
|
|
register_device_value(TAG_BOILER_DATA, &upTimeCompWw_, DeviceValueType::TIME, FL_(div60), F("upTimeCompWw"), F("operating time compressor warm water"), DeviceValueUOM::MINUTES);
|
|
register_device_value(TAG_BOILER_DATA, &heatingStarts_, DeviceValueType::ULONG, nullptr, F("heatingStarts"), F("# heating control starts"));
|
|
register_device_value(TAG_BOILER_DATA, &coolingStarts_, DeviceValueType::ULONG, nullptr, F("coolingStarts"), F("# cooling control starts"));
|
|
register_device_value(TAG_BOILER_DATA, &nrgConsTotal_, DeviceValueType::ULONG, nullptr, F("nrgConsTotal"), F("total energy consumption"));
|
|
register_device_value(TAG_BOILER_DATA, &nrgConsCompTotal_, DeviceValueType::ULONG, nullptr, F("nrgConsCompTotal"), F("energy consumption compressor total"));
|
|
register_device_value(TAG_BOILER_DATA, &nrgConsCompHeating_, DeviceValueType::ULONG, nullptr, F("nrgConsCompHeating"), F("energy consumption compressor heating"));
|
|
register_device_value(TAG_BOILER_DATA, &nrgConsCompWw_, DeviceValueType::ULONG, nullptr, F("nrgConsCompWw"), F("energy consumption compressor warm water"));
|
|
register_device_value(TAG_BOILER_DATA, &nrgConsCompCooling_, DeviceValueType::ULONG, nullptr, F("nrgConsCompCooling"), F("energy consumption compressor cooling"));
|
|
register_device_value(TAG_BOILER_DATA, &nrgSuppTotal_, DeviceValueType::ULONG, nullptr, F("nrgSuppTotal"), F("total energy supplied"));
|
|
register_device_value(TAG_BOILER_DATA, &nrgSuppHeating_, DeviceValueType::ULONG, nullptr, F("nrgSuppHeating"), F("total energy supplied heating"));
|
|
register_device_value(TAG_BOILER_DATA, &nrgSuppWw_, DeviceValueType::ULONG, nullptr, F("nrgSuppWw"), F("total energy warm supplied warm water"));
|
|
register_device_value(TAG_BOILER_DATA, &nrgSuppCooling_, DeviceValueType::ULONG, nullptr, F("nrgSuppCooling"), F("total energy supplied cooling"));
|
|
register_device_value(TAG_BOILER_DATA, &auxElecHeatNrgConsTotal_, DeviceValueType::ULONG, nullptr, F("auxElecHeatNrgConsTotal"), F("auxiliary electrical heater energy consumption total"));
|
|
register_device_value(TAG_BOILER_DATA, &auxElecHeatNrgConsHeating_, DeviceValueType::ULONG, nullptr, F("auxElecHeatNrgConsHeating"), F("auxiliary electrical heater energy consumption heating"));
|
|
register_device_value(TAG_BOILER_DATA, &auxElecHeatNrgConsDHW_, DeviceValueType::ULONG, nullptr, F("auxElecHeatNrgConsDHW"), F("auxiliary electrical heater energy consumption DHW"));
|
|
register_device_value(TAG_BOILER_DATA, &maintenanceMessage_, DeviceValueType::TEXT, nullptr, F("maintenanceMessage"), F("maintenance message"));
|
|
register_device_value(TAG_BOILER_DATA, &maintenanceDate_, DeviceValueType::TEXT, nullptr, F("maintenanceDate"), F("maintenance set date"));
|
|
register_device_value(TAG_BOILER_DATA, &maintenanceType_, DeviceValueType::ENUM, FL_(enum_off_time_date), F("maintenanceType"), F("maintenance scheduled"));
|
|
register_device_value(TAG_BOILER_DATA, &maintenanceTime_, DeviceValueType::USHORT, nullptr, F("maintenanceTime"), F("maintenance set time"), DeviceValueUOM::HOURS);
|
|
|
|
// warm water - boiler_data_ww topic
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWSelTemp_, DeviceValueType::UINT, nullptr, F("wWSelTemp"), F("selected temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWSetTemp_, DeviceValueType::UINT, nullptr, F("wWSetTemp"), F("set temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWType_, DeviceValueType::ENUM, FL_(enum_flow), F("wWType"), F("type"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWComfort_, DeviceValueType::ENUM, FL_(enum_comfort), F("wWComfort"), F("comfort"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWFlowTempOffset_, DeviceValueType::UINT, nullptr, F("wWFlowTempOffset"), F("flow temperature offset"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWMaxPower_, DeviceValueType::UINT, nullptr, F("wWMaxPower"), F("max power"), DeviceValueUOM::PERCENT);
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWCircPump_, DeviceValueType::BOOL, nullptr, F("wWCircPump"), F("circulation pump available"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWChargeType_, DeviceValueType::BOOL, FL_(enum_charge), F("wWChargeType"), F("charging type"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWDisinfectionTemp_, DeviceValueType::UINT, nullptr, F("wWDisinfectionTemp"), F("disinfection temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWCircMode_, DeviceValueType::ENUM, FL_(enum_freq), F("wWCircMode"), F("circulation pump freq"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWCirc_, DeviceValueType::BOOL, nullptr, F("wWCirc"), F("circulation active"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWCurTemp_, DeviceValueType::USHORT, FL_(div10), F("wWCurTemp"), F("current intern temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWCurTemp2_, DeviceValueType::USHORT, FL_(div10), F("wWCurTemp2"), F("current extern temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWCurFlow_, DeviceValueType::UINT, FL_(div10), F("wWCurFlow"), F("current tap water flow"), DeviceValueUOM::LMIN);
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWStorageTemp1_, DeviceValueType::USHORT, FL_(div10), F("wWStorageTemp1"), F("storage intern temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWStorageTemp2_, DeviceValueType::USHORT, FL_(div10), F("wWStorageTemp2"), F("storage extern temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWActivated_, DeviceValueType::BOOL, nullptr, F("wWActivated"), F("activated"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWOneTime_, DeviceValueType::BOOL, nullptr, F("wWOneTime"), F("one time charging"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWDisinfecting_, DeviceValueType::BOOL, nullptr, F("wWDisinfecting"), F("disinfecting"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWCharging_, DeviceValueType::BOOL, nullptr, F("wWCharging"), F("charging"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWRecharging_, DeviceValueType::BOOL, nullptr, F("wWRecharging"), F("recharging"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWTempOK_, DeviceValueType::BOOL, nullptr, F("wWTempOK"), F("temperature ok"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWActive_, DeviceValueType::BOOL, nullptr, F("wWActive"), F("active"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWHeat_, DeviceValueType::BOOL, nullptr, F("wWHeat"), F("heating"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWSetPumpPower_, DeviceValueType::UINT, nullptr, F("wWSetPumpPower"), F("pump set power"), DeviceValueUOM::PERCENT);
|
|
register_device_value(TAG_BOILER_DATA_WW, &mixerTemp_, DeviceValueType::USHORT, FL_(div10), F("mixerTemp"), F("mixer temperature"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA_WW, &tankMiddleTemp_, DeviceValueType::USHORT, FL_(div10), F("tankMiddleTemp"), F("tank middle temperature (TS3)"), DeviceValueUOM::DEGREES);
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWStarts_, DeviceValueType::ULONG, nullptr, F("wWStarts"), F("# starts"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWStarts2_, DeviceValueType::ULONG, nullptr, F("wWStarts2"), F("# control starts"));
|
|
register_device_value(TAG_BOILER_DATA_WW, &wWWorkM_, DeviceValueType::TIME, nullptr, F("wWWorkM"), F("active time"), DeviceValueUOM::MINUTES);
|
|
|
|
// fetch some initial data
|
|
EMSESP::send_read_request(0x10, device_id); // read last errorcode on start (only published on errors)
|
|
EMSESP::send_read_request(0x11, device_id); // read last errorcode on start (only published on errors)
|
|
EMSESP::send_read_request(0x15, device_id); // read maintenace data on start (only published on change)
|
|
EMSESP::send_read_request(0x1C, device_id); // read maintenace status on start (only published on change)
|
|
}
|
|
|
|
// publish HA config
|
|
bool Boiler::publish_ha_config() {
|
|
StaticJsonDocument<EMSESP_JSON_SIZE_HA_CONFIG> doc;
|
|
doc["uniq_id"] = F_(boiler);
|
|
|
|
char stat_t[Mqtt::MQTT_TOPIC_MAX_SIZE];
|
|
snprintf_P(stat_t, sizeof(stat_t), PSTR("%s/%s"), Mqtt::base().c_str(), Mqtt::tag_to_topic(device_type(), DeviceValueTAG::TAG_NONE).c_str());
|
|
doc["stat_t"] = stat_t;
|
|
|
|
doc["name"] = FJSON("ID");
|
|
doc["val_tpl"] = FJSON("{{value_json.id}}");
|
|
JsonObject dev = doc.createNestedObject("dev");
|
|
dev["name"] = FJSON("EMS-ESP Boiler");
|
|
dev["sw"] = EMSESP_APP_VERSION;
|
|
dev["mf"] = brand_to_string();
|
|
dev["mdl"] = name();
|
|
JsonArray ids = dev.createNestedArray("ids");
|
|
ids.add("ems-esp-boiler");
|
|
|
|
char topic[Mqtt::MQTT_TOPIC_MAX_SIZE];
|
|
snprintf_P(topic, sizeof(topic), PSTR("homeassistant/sensor/%s/boiler/config"), Mqtt::base().c_str());
|
|
Mqtt::publish_ha(topic, doc.as<JsonObject>()); // publish the config payload with retain flag
|
|
|
|
return true;
|
|
}
|
|
|
|
// Check if hot tap water or heating is active
|
|
// Values will always be posted first time as heatingActive_ and tapwaterActive_ will have values EMS_VALUE_BOOL_NOTSET
|
|
void Boiler::check_active(const bool force) {
|
|
if (!Helpers::hasValue(boilerState_)) {
|
|
return;
|
|
}
|
|
|
|
bool b;
|
|
uint8_t val;
|
|
|
|
// check if heating is active, bits 2 and 4 must be set
|
|
b = ((boilerState_ & 0x09) == 0x09);
|
|
val = b ? EMS_VALUE_BOOL_ON : EMS_VALUE_BOOL_OFF;
|
|
if (heatingActive_ != val || force) {
|
|
heatingActive_ = val;
|
|
char s[7];
|
|
Mqtt::publish(F("heating_active"), Helpers::render_boolean(s, b));
|
|
}
|
|
|
|
// check if tap water is active, bits 1 and 4 must be set
|
|
// also check if there is a flowsensor and flow-type
|
|
static bool flowsensor = false;
|
|
if (Helpers::hasValue(wWCurFlow_) && (wWCurFlow_ > 0) && (wWType_ == 1)) {
|
|
flowsensor = true;
|
|
}
|
|
if (flowsensor) {
|
|
b = ((wWCurFlow_ > 0) && ((boilerState_ & 0x0A) == 0x0A));
|
|
} else {
|
|
b = ((boilerState_ & 0x0A) == 0x0A);
|
|
}
|
|
|
|
val = b ? EMS_VALUE_BOOL_ON : EMS_VALUE_BOOL_OFF;
|
|
if (tapwaterActive_ != val || force) {
|
|
tapwaterActive_ = val;
|
|
char s[7];
|
|
Mqtt::publish(F("tapwater_active"), Helpers::render_boolean(s, b));
|
|
EMSESP::tap_water_active(b); // let EMS-ESP know, used in the Shower class
|
|
}
|
|
}
|
|
|
|
// 0x33
|
|
void Boiler::process_UBAParameterWW(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(wWActivated_, 1)); // 0xFF means on
|
|
has_update(telegram->read_value(wWCircPump_, 6)); // 0xFF means on
|
|
has_update(telegram->read_value(wWCircMode_, 7)); // 1=1x3min 6=6x3min 7=continuous
|
|
has_update(telegram->read_value(wWChargeType_, 10)); // 0 = charge pump, 0xff = 3-way valve
|
|
has_update(telegram->read_value(wWSelTemp_, 2));
|
|
has_update(telegram->read_value(wWDisinfectionTemp_, 8));
|
|
has_update(telegram->read_value(wWFlowTempOffset_, 5));
|
|
|
|
telegram->read_value(wWComfort_, 9);
|
|
if (wWComfort_ == 0x00) {
|
|
wWComfort_ = 0; // Hot
|
|
} else if (wWComfort_ == 0xD8) {
|
|
wWComfort_ = 1; // Eco
|
|
} else if (wWComfort_ == 0xEC) {
|
|
wWComfort_ = 2; // Intelligent
|
|
} else {
|
|
wWComfort_ = EMS_VALUE_UINT_NOTSET;
|
|
}
|
|
}
|
|
|
|
// 0x18
|
|
void Boiler::process_UBAMonitorFast(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(selFlowTemp_, 0));
|
|
has_update(telegram->read_value(curFlowTemp_, 1));
|
|
has_update(telegram->read_value(selBurnPow_, 3)); // burn power max setting
|
|
has_update(telegram->read_value(curBurnPow_, 4));
|
|
has_update(telegram->read_value(boilerState_, 5));
|
|
|
|
has_update(telegram->read_bitvalue(burnGas_, 7, 0));
|
|
has_update(telegram->read_bitvalue(fanWork_, 7, 2));
|
|
has_update(telegram->read_bitvalue(ignWork_, 7, 3));
|
|
has_update(telegram->read_bitvalue(heatingPump_, 7, 5));
|
|
has_update(telegram->read_bitvalue(wWHeat_, 7, 6));
|
|
has_update(telegram->read_bitvalue(wWCirc_, 7, 7));
|
|
|
|
// warm water storage sensors (if present)
|
|
// wWStorageTemp2 is also used by some brands as the boiler temperature - see https://github.com/emsesp/EMS-ESP/issues/206
|
|
has_update(telegram->read_value(wWStorageTemp1_, 9)); // 0x8300 if not available
|
|
has_update(telegram->read_value(wWStorageTemp2_, 11)); // 0x8000 if not available - this is boiler temp
|
|
|
|
has_update(telegram->read_value(retTemp_, 13));
|
|
has_update(telegram->read_value(flameCurr_, 15));
|
|
|
|
// system pressure. FF means missing
|
|
has_update(telegram->read_value(sysPress_, 17)); // is *10
|
|
|
|
// read the service code / installation status as appears on the display
|
|
if ((telegram->message_length > 18) && (telegram->offset == 0)) {
|
|
serviceCode_[0] = (serviceCode_[0] == '~') ? 0xF0 : serviceCode_[0];
|
|
has_update(telegram->read_value(serviceCode_[0], 18));
|
|
serviceCode_[0] = (serviceCode_[0] == (char)0xF0) ? '~' : serviceCode_[0];
|
|
has_update(telegram->read_value(serviceCode_[1], 19));
|
|
serviceCode_[2] = '\0'; // null terminate string
|
|
}
|
|
|
|
has_update(telegram->read_value(serviceCodeNumber_, 20));
|
|
|
|
check_active(); // do a quick check to see if the hot water or heating is active
|
|
}
|
|
|
|
/*
|
|
* UBATotalUptime - type 0x14 - total uptime
|
|
* received only after requested (not broadcasted)
|
|
*/
|
|
void Boiler::process_UBATotalUptime(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(UBAuptime_, 0, 3)); // force to 3 bytes
|
|
}
|
|
|
|
/*
|
|
* UBAParameters - type 0x16
|
|
* data: FF 5A 64 00 0A FA 0F 02 06 64 64 02 08 F8 0F 0F 0F 0F 1E 05 04 09 09 00 28 00 3C
|
|
*/
|
|
void Boiler::process_UBAParameters(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(heatingActivated_, 0));
|
|
has_update(telegram->read_value(heatingTemp_, 1));
|
|
has_update(telegram->read_value(burnMaxPower_, 2));
|
|
has_update(telegram->read_value(burnMinPower_, 3));
|
|
has_update(telegram->read_value(boilHystOff_, 4));
|
|
has_update(telegram->read_value(boilHystOn_, 5));
|
|
has_update(telegram->read_value(burnMinPeriod_, 6));
|
|
has_update(telegram->read_value(pumpDelay_, 8));
|
|
has_update(telegram->read_value(pumpModMax_, 9));
|
|
has_update(telegram->read_value(pumpModMin_, 10));
|
|
}
|
|
|
|
/*
|
|
* UBASettingsWW - type 0x26 - max power on offset 7, #740
|
|
* Boiler(0x08) -> Me(0x0B), ?(0x26), data: 01 05 00 0F 00 1E 58 5A
|
|
*/
|
|
void Boiler::process_UBASettingsWW(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(wWMaxPower_, 7));
|
|
}
|
|
|
|
/*
|
|
* UBAMonitorWW - type 0x34 - warm water monitor. 19 bytes long
|
|
* received every 10 seconds
|
|
*/
|
|
void Boiler::process_UBAMonitorWW(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(wWSetTemp_, 0));
|
|
has_update(telegram->read_value(wWCurTemp_, 1));
|
|
has_update(telegram->read_value(wWCurTemp2_, 3));
|
|
has_update(telegram->read_value(wWCurFlow_, 9));
|
|
has_update(telegram->read_value(wWType_, 8));
|
|
|
|
has_update(telegram->read_value(wWWorkM_, 10, 3)); // force to 3 bytes
|
|
has_update(telegram->read_value(wWStarts_, 13, 3)); // force to 3 bytes
|
|
|
|
has_update(telegram->read_bitvalue(wWOneTime_, 5, 1));
|
|
has_update(telegram->read_bitvalue(wWDisinfecting_, 5, 2));
|
|
has_update(telegram->read_bitvalue(wWCharging_, 5, 3));
|
|
has_update(telegram->read_bitvalue(wWRecharging_, 5, 4));
|
|
has_update(telegram->read_bitvalue(wWTempOK_, 5, 5));
|
|
has_update(telegram->read_bitvalue(wWActive_, 5, 6));
|
|
}
|
|
|
|
/*
|
|
* UBAMonitorFastPlus - type 0xE4 - central heating monitor EMS+
|
|
* temperatures at 7 and 23 always identical
|
|
+ * Bosch Logamax Plus GB122: issue #620
|
|
+ * 88 00 E4 00 00 2D 2D 00 00 C9 34 02 21 64 3D 05 02 01 DE 00 00 00 00 03 62 14 00 02 21 00 00 00 00 00 00 00 2B 2B 83
|
|
+ * GB125/Logamatic MC110: issue #650: add retTemp & sysPress
|
|
+ * 08 00 E4 00 10 20 2D 48 00 C8 38 02 37 3C 27 03 00 00 00 00 00 01 7B 01 8F 11 00 02 37 80 00 02 1B 80 00 7F FF 80 00
|
|
*/
|
|
void Boiler::process_UBAMonitorFastPlus(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(selFlowTemp_, 6));
|
|
has_update(telegram->read_bitvalue(burnGas_, 11, 0));
|
|
// has_update(telegram->read_bitvalue(heatingPump_, 11, 1)); // heating active? see SlowPlus
|
|
has_update(telegram->read_bitvalue(wWHeat_, 11, 2));
|
|
has_update(telegram->read_value(curBurnPow_, 10));
|
|
has_update(telegram->read_value(selBurnPow_, 9));
|
|
has_update(telegram->read_value(curFlowTemp_, 7));
|
|
has_update(telegram->read_value(flameCurr_, 19));
|
|
has_update(telegram->read_value(retTemp_,
|
|
17)); // can be 0 if no sensor, handled in export_values
|
|
has_update(telegram->read_value(sysPress_, 21));
|
|
|
|
//has_update(telegram->read_value(temperatur_, 13)); // unknown temperature
|
|
//has_update(telegram->read_value(temperatur_, 27)); // unknown temperature
|
|
|
|
// read 3 char service code / installation status as appears on the display
|
|
if ((telegram->message_length > 3) && (telegram->offset == 0)) {
|
|
serviceCode_[0] = (serviceCode_[0] == '~') ? 0xF0 : serviceCode_[0];
|
|
has_update(telegram->read_value(serviceCode_[0], 1));
|
|
serviceCode_[0] = (serviceCode_[0] == (char)0xF0) ? '~' : serviceCode_[0];
|
|
has_update(telegram->read_value(serviceCode_[1], 2));
|
|
has_update(telegram->read_value(serviceCode_[2], 3));
|
|
serviceCode_[3] = '\0';
|
|
}
|
|
has_update(telegram->read_value(serviceCodeNumber_, 4));
|
|
|
|
// at this point do a quick check to see if the hot water or heating is active
|
|
uint8_t state = EMS_VALUE_UINT_NOTSET;
|
|
if (telegram->read_value(state, 11)) {
|
|
boilerState_ = state & 0x01 ? 0x08 : 0;
|
|
boilerState_ |= state & 0x02 ? 0x01 : 0;
|
|
boilerState_ |= state & 0x04 ? 0x02 : 0;
|
|
}
|
|
|
|
check_active(); // do a quick check to see if the hot water or heating is active
|
|
}
|
|
|
|
/*
|
|
* UBAMonitorSlow - type 0x19 - central heating monitor part 2 (27 bytes long)
|
|
* received every 60 seconds
|
|
* e.g. 08 00 19 00 80 00 02 41 80 00 00 00 00 00 03 91 7B 05 B8 40 00 00 00 04 92 AD 00 5E EE 80 00
|
|
* 08 0B 19 00 FF EA 02 47 80 00 00 00 00 62 03 CA 24 2C D6 23 00 00 00 27 4A B6 03 6E 43
|
|
* 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 17 19 20 21 22 23 24
|
|
*/
|
|
void Boiler::process_UBAMonitorSlow(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(outdoorTemp_, 0));
|
|
has_update(telegram->read_value(boilTemp_, 2));
|
|
has_update(telegram->read_value(exhaustTemp_, 4));
|
|
has_update(telegram->read_value(switchTemp_, 25)); // only if there is a mixer module present
|
|
has_update(telegram->read_value(heatingPumpMod_, 9));
|
|
has_update(telegram->read_value(burnStarts_, 10, 3)); // force to 3 bytes
|
|
has_update(telegram->read_value(burnWorkMin_, 13, 3)); // force to 3 bytes
|
|
has_update(telegram->read_value(heatWorkMin_, 19, 3)); // force to 3 bytes
|
|
}
|
|
|
|
/*
|
|
* UBAMonitorSlowPlus2 - type 0xE3
|
|
* 88 00 E3 00 04 00 00 00 00 01 00 00 00 00 00 02 22 2B 64 46 01 00 00 61
|
|
*/
|
|
void Boiler::process_UBAMonitorSlowPlus2(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(heatingPump2Mod_, 13)); // Heat Pump Modulation
|
|
}
|
|
|
|
/*
|
|
* UBAMonitorSlowPlus - type 0xE5 - central heating monitor EMS+
|
|
* Boiler(0x08) -> Me(0x0B), UBAMonitorSlowPlus(0xE5),
|
|
* data: 01 00 20 00 00 78 00 00 00 00 00 1E EB 00 9D 3E 00 00 00 00 6B 5E 00 06 4C 64 00 00 00 00 8A A3
|
|
*/
|
|
void Boiler::process_UBAMonitorSlowPlus(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_bitvalue(fanWork_, 2, 2));
|
|
has_update(telegram->read_bitvalue(ignWork_, 2, 3));
|
|
has_update(telegram->read_bitvalue(heatingPump_, 2, 5));
|
|
has_update(telegram->read_bitvalue(wWCirc_, 2, 7));
|
|
has_update(telegram->read_value(exhaustTemp_, 6));
|
|
has_update(telegram->read_value(burnStarts_, 10, 3)); // force to 3 bytes
|
|
has_update(telegram->read_value(burnWorkMin_, 13, 3)); // force to 3 bytes
|
|
has_update(telegram->read_value(heatWorkMin_, 19, 3)); // force to 3 bytes
|
|
has_update(telegram->read_value(heatingPumpMod_, 25));
|
|
// temperature measurements at 4, see #620
|
|
}
|
|
|
|
/*
|
|
* UBAParametersPlus - type 0xE6
|
|
* parameters originaly taken from
|
|
* https://github.com/Th3M3/buderus_ems-wiki/blob/master/Einstellungen%20des%20Regelger%C3%A4ts%20MC110.md
|
|
* 88 0B E6 00 01 46 00 00 46 0A 00 01 06 FA 0A 01 02 64 01 00 00 1E 00 3C 01 00 00 00 01 00 9A
|
|
* from: issue #732
|
|
* data: 01 50 1E 5A 46 12 64 00 06 FA 3C 03 05 64 00 00 00 28 00 41 03 00 00 00 00 00 00 00 00 00
|
|
*/
|
|
void Boiler::process_UBAParametersPlus(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(heatingActivated_, 0));
|
|
has_update(telegram->read_value(heatingTemp_, 1));
|
|
has_update(telegram->read_value(burnMaxPower_, 4));
|
|
has_update(telegram->read_value(burnMinPower_, 5));
|
|
has_update(telegram->read_value(boilHystOff_, 8));
|
|
has_update(telegram->read_value(boilHystOn_, 9));
|
|
has_update(telegram->read_value(burnMinPeriod_, 10));
|
|
// has_update(telegram->read_value(pumpType_, 11)); // guess, RC300 manual: powercontroled, pressurcontrolled 1-4?
|
|
// has_update(telegram->read_value(pumpDelay_, 12)); // guess
|
|
// has_update(telegram->read_value(pumpModMax_, 13)); // guess
|
|
// has_update(telegram->read_value(pumpModMin_, 14)); // guess
|
|
}
|
|
|
|
// 0xEA
|
|
void Boiler::process_UBAParameterWWPlus(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(wWActivated_, 5)); // 0x01 means on
|
|
has_update(telegram->read_value(wWCircPump_, 10)); // 0x01 means yes
|
|
has_update(telegram->read_value(wWCircMode_, 11)); // 1=1x3min... 6=6x3min, 7=continuous
|
|
// has_update(telegram->read_value(wWDisinfectTemp_, 12)); // settings, status in E9
|
|
// has_update(telegram->read_value(wWSelTemp_, 6)); // settings, status in E9
|
|
}
|
|
|
|
// 0xE9 - DHW Status
|
|
// e.g. 08 00 E9 00 37 01 F6 01 ED 00 00 00 00 41 3C 00 00 00 00 00 00 00 00 00 00 00 00 37 00 00 00 (CRC=77) #data=27
|
|
void Boiler::process_UBADHWStatus(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(wWSetTemp_, 0));
|
|
has_update(telegram->read_value(wWCurTemp_, 1));
|
|
has_update(telegram->read_value(wWCurTemp2_, 3));
|
|
|
|
has_update(telegram->read_value(wWWorkM_, 14, 3)); // force to 3 bytes
|
|
has_update(telegram->read_value(wWStarts_, 17, 3)); // force to 3 bytes
|
|
|
|
has_update(telegram->read_bitvalue(wWOneTime_, 12, 2));
|
|
has_update(telegram->read_bitvalue(wWDisinfecting_, 12, 3));
|
|
has_update(telegram->read_bitvalue(wWCharging_, 12, 4));
|
|
has_update(telegram->read_bitvalue(wWRecharging_, 13, 4));
|
|
has_update(telegram->read_bitvalue(wWTempOK_, 13, 5));
|
|
has_update(telegram->read_bitvalue(wWCirc_, 13, 2));
|
|
|
|
// has_update(telegram->read_value(wWActivated_, 20)); // Activated is in 0xEA, this is something other 0/100%
|
|
has_update(telegram->read_value(wWSelTemp_, 10));
|
|
has_update(telegram->read_value(wWDisinfectionTemp_, 9));
|
|
}
|
|
|
|
/*
|
|
* UBAInformation - type 0x495
|
|
* all values 32 bit
|
|
* 08 0B FF 00 03 95 01 01 AB 83 00 27 78 EB 00 84 FA 39 FF FF FF 00 00 53 7D 8D 00 00 0F 04 1C
|
|
* 08 00 FF 00 03 95 01 01 AB 83 00 27 78 EB 00 84 FA 39 FF FF FF 00 00 53 7D 8D 00 00 0F 04 63
|
|
* 08 00 FF 18 03 95 00 00 05 84 00 00 07 22 FF FF FF FF 00 00 02 5C 00 00 03 C0 00 00 01 98 64
|
|
* 08 00 FF 30 03 95 00 00 00 D4 FF FF FF FF 00 00 1C 70 FF FF FF FF 00 00 20 30 00 00 0E 06 FB
|
|
* 08 00 FF 48 03 95 00 00 06 C0 00 00 07 66 FF FF FF FF 2E
|
|
*/
|
|
void Boiler::process_UBAInformation(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(upTimeControl_, 0));
|
|
has_update(telegram->read_value(upTimeCompHeating_, 8));
|
|
has_update(telegram->read_value(upTimeCompCooling_, 16));
|
|
has_update(telegram->read_value(upTimeCompWw_, 4));
|
|
|
|
has_update(telegram->read_value(heatingStarts_, 28));
|
|
has_update(telegram->read_value(coolingStarts_, 36));
|
|
has_update(telegram->read_value(wWStarts2_, 24));
|
|
|
|
has_update(telegram->read_value(nrgConsTotal_, 64));
|
|
|
|
has_update(telegram->read_value(auxElecHeatNrgConsTotal_, 40));
|
|
has_update(telegram->read_value(auxElecHeatNrgConsHeating_, 48));
|
|
has_update(telegram->read_value(auxElecHeatNrgConsDHW_, 44));
|
|
|
|
has_update(telegram->read_value(nrgConsCompTotal_, 56));
|
|
has_update(telegram->read_value(nrgConsCompHeating_, 68));
|
|
has_update(telegram->read_value(nrgConsCompWw_, 72));
|
|
has_update(telegram->read_value(nrgConsCompCooling_, 76));
|
|
}
|
|
|
|
/*
|
|
* UBAEnergy - type 0x494
|
|
* Energy-values all 32bit
|
|
* 08 00 FF 00 03 94 03 31 21 59 00 00 7C 70 00 00 15 B8 00 00 40 E3 00 00 27 23 FF FF FF FF EA
|
|
* 08 00 FF 18 03 94 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF 00 00 00 00 00 00 00 00 00 7E
|
|
* 08 00 FF 31 03 94 00 00 00 00 00 00 00 38
|
|
*/
|
|
void Boiler::process_UBAEnergySupplied(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(nrgSuppTotal_, 4));
|
|
has_update(telegram->read_value(nrgSuppHeating_, 12));
|
|
has_update(telegram->read_value(nrgSuppWw_, 8));
|
|
has_update(telegram->read_value(nrgSuppCooling_, 16));
|
|
}
|
|
|
|
// 0x2A - MC10Status
|
|
// e.g. 88 00 2A 00 00 00 00 00 00 00 00 00 D2 00 00 80 00 00 01 08 80 00 02 47 00
|
|
// see https://github.com/emsesp/EMS-ESP/issues/397
|
|
void Boiler::process_MC10Status(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(mixerTemp_, 14));
|
|
has_update(telegram->read_value(tankMiddleTemp_, 18));
|
|
}
|
|
|
|
/*
|
|
* UBAOutdoorTemp - type 0xD1 - external temperature EMS+
|
|
*/
|
|
void Boiler::process_UBAOutdoorTemp(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(outdoorTemp_, 0));
|
|
}
|
|
|
|
// UBASetPoint 0x1A
|
|
void Boiler::process_UBASetPoints(std::shared_ptr<const Telegram> telegram) {
|
|
has_update(telegram->read_value(setFlowTemp_,
|
|
0)); // boiler set temp from thermostat
|
|
has_update(telegram->read_value(setBurnPow_, 1)); // max json power in %
|
|
has_update(telegram->read_value(wWSetPumpPower_, 2)); // ww pump speed/power?
|
|
}
|
|
|
|
// 0x6DC, ff for cascaded heatsources (hs)
|
|
void Boiler::process_CascadeMessage(std::shared_ptr<const Telegram> telegram) {
|
|
// uint8_t hsActivated;
|
|
// has_update(telegram->read_value(hsActivated, 0));
|
|
telegram->read_value(burnWorkMin_, 3); // this is in seconds
|
|
burnWorkMin_ /= 60;
|
|
}
|
|
|
|
#pragma GCC diagnostic push
|
|
#pragma GCC diagnostic ignored "-Wunused-parameter"
|
|
|
|
// 0x35 - not yet implemented
|
|
void Boiler::process_UBAFlags(std::shared_ptr<const Telegram> telegram) {
|
|
}
|
|
#pragma GCC diagnostic pop
|
|
|
|
// 0x1C
|
|
// 08 00 1C 94 0B 0A 1D 31 08 00 80 00 00 00 -> message for 29.11.2020
|
|
// 08 00 1C 94 0B 0A 1D 31 00 00 00 00 00 00 -> message reset
|
|
void Boiler::process_UBAMaintenanceStatus(std::shared_ptr<const Telegram> telegram) {
|
|
// 5. byte: Maintenance due (0 = no, 3 = yes, due to operating hours, 8 = yes, due to date)
|
|
uint8_t message_code = maintenanceMessage_[2] - '0';
|
|
has_update(telegram->read_value(message_code, 5));
|
|
|
|
// ignore if 0, which means all is ok
|
|
if (Helpers::hasValue(message_code) && message_code > 0) {
|
|
snprintf_P(maintenanceMessage_, sizeof(maintenanceMessage_), PSTR("H%02d"), message_code);
|
|
}
|
|
}
|
|
|
|
// 0x10, 0x11
|
|
void Boiler::process_UBAErrorMessage(std::shared_ptr<const Telegram> telegram) {
|
|
if (telegram->offset > 0 || telegram->message_length < 9) {
|
|
return;
|
|
}
|
|
// data: displaycode(2), errornumber(2), year, month, hour, day, minute, duration(2), src-addr
|
|
if (telegram->message_data[4] & 0x80) { // valid date
|
|
|
|
static uint32_t lastCodeDate_ = 0; // last code date
|
|
char code[3];
|
|
uint16_t codeNo;
|
|
code[0] = telegram->message_data[0];
|
|
code[1] = telegram->message_data[1];
|
|
code[2] = 0;
|
|
telegram->read_value(codeNo, 2);
|
|
uint16_t year = (telegram->message_data[4] & 0x7F) + 2000;
|
|
uint8_t month = telegram->message_data[5];
|
|
uint8_t day = telegram->message_data[7];
|
|
uint8_t hour = telegram->message_data[6];
|
|
uint8_t min = telegram->message_data[8];
|
|
uint32_t date = (year - 2000) * 535680UL + month * 44640UL + day * 1440UL + hour * 60 + min;
|
|
// store only the newest code from telegrams 10 and 11
|
|
if (date > lastCodeDate_) {
|
|
snprintf_P(lastCode_, sizeof(lastCode_), PSTR("%s(%d) %02d.%02d.%d %02d:%02d"), code, codeNo, day, month, year, hour, min);
|
|
lastCodeDate_ = date;
|
|
}
|
|
}
|
|
}
|
|
|
|
// 0x15
|
|
void Boiler::process_UBAMaintenanceData(std::shared_ptr<const Telegram> telegram) {
|
|
if (telegram->offset > 0 || telegram->message_length < 5) {
|
|
return;
|
|
}
|
|
// first byte: Maintenance messages (0 = none, 1 = by operating hours, 2 = by date)
|
|
|
|
has_update(telegram->read_value(maintenanceType_, 0));
|
|
|
|
uint8_t time = (maintenanceTime_ == EMS_VALUE_USHORT_NOTSET) ? EMS_VALUE_UINT_NOTSET : maintenanceTime_ / 100;
|
|
has_update(telegram->read_value(time, 1));
|
|
maintenanceTime_ = (time == EMS_VALUE_UINT_NOTSET) ? EMS_VALUE_USHORT_NOTSET : time * 100;
|
|
// telegram->read_value(maintenanceTime_, 1, 1);
|
|
// maintenanceTime_ = maintenanceTime * 100;
|
|
|
|
// date only
|
|
uint8_t day = telegram->message_data[2];
|
|
uint8_t month = telegram->message_data[3];
|
|
uint8_t year = telegram->message_data[4];
|
|
if (day > 0 && month > 0) {
|
|
snprintf_P(maintenanceDate_, sizeof(maintenanceDate_), PSTR("%02d.%02d.%04d"), day, month, year + 2000);
|
|
}
|
|
}
|
|
|
|
// Set the warm water temperature 0x33
|
|
bool Boiler::set_warmwater_temp(const char * value, const int8_t id) {
|
|
int v = 0;
|
|
if (!Helpers::value2number(value, v)) {
|
|
LOG_WARNING(F("Set boiler warm water temperature: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting boiler warm water temperature to %d C"), v);
|
|
if (get_toggle_fetch(EMS_TYPE_UBAParametersPlus)) {
|
|
write_command(EMS_TYPE_UBAParameterWWPlus, 6, v, EMS_TYPE_UBAParameterWWPlus);
|
|
} else {
|
|
write_command(EMS_TYPE_UBAFlags, 3, v, 0x34); // for i9000, see #397
|
|
write_command(EMS_TYPE_UBAParameterWW, 2, v, EMS_TYPE_UBAParameterWW); // read seltemp back
|
|
}
|
|
|
|
return true;
|
|
}
|
|
|
|
// flow temp
|
|
bool Boiler::set_flow_temp(const char * value, const int8_t id) {
|
|
int v = 0;
|
|
if (!Helpers::value2number(value, v)) {
|
|
LOG_WARNING(F("Set boiler flow temperature: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting boiler flow temperature to %d C"), v);
|
|
// some boiler have it in 0x1A, some in 0x35, but both telegrams are sometimes writeonly
|
|
write_command(EMS_TYPE_UBASetPoints, 0, v, EMS_TYPE_UBASetPoints);
|
|
// write_command(0x35, 3, v, 0x35);
|
|
|
|
return true;
|
|
}
|
|
|
|
// Set the warm water flow temperature offset 0x33
|
|
bool Boiler::set_wWFlowTempOffset(const char * value, const int8_t id) {
|
|
int v = 0;
|
|
if (!Helpers::value2number(value, v)) {
|
|
LOG_WARNING(F("Set boiler warm water flow temperature offset: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting boiler warm water flow temperature offset to %d C"), v);
|
|
write_command(EMS_TYPE_UBAParameterWW, 5, v, EMS_TYPE_UBAParameterWW);
|
|
|
|
return true;
|
|
}
|
|
|
|
// set heating activated
|
|
bool Boiler::set_heating_activated(const char * value, const int8_t id) {
|
|
bool v = false;
|
|
if (!Helpers::value2bool(value, v)) {
|
|
LOG_WARNING(F("Set boiler heating: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting boiler heating %s"), v ? "on" : "off");
|
|
if (get_toggle_fetch(EMS_TYPE_UBAParametersPlus)) {
|
|
write_command(EMS_TYPE_UBAParametersPlus, 0, v ? 0x01 : 0, EMS_TYPE_UBAParametersPlus);
|
|
} else {
|
|
write_command(EMS_TYPE_UBAParameters, 0, v ? 0xFF : 0, EMS_TYPE_UBAParameters);
|
|
}
|
|
|
|
return true;
|
|
}
|
|
|
|
// set heating maximum temperature
|
|
bool Boiler::set_heating_temp(const char * value, const int8_t id) {
|
|
int v = 0;
|
|
if (!Helpers::value2number(value, v)) {
|
|
LOG_WARNING(F("Set boiler heating temperature: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting boiler heating temperature to %d C"), v);
|
|
if (get_toggle_fetch(EMS_TYPE_UBAParametersPlus)) {
|
|
write_command(EMS_TYPE_UBAParametersPlus, 1, v, EMS_TYPE_UBAParametersPlus);
|
|
} else {
|
|
write_command(EMS_TYPE_UBAParameters, 1, v, EMS_TYPE_UBAParameters);
|
|
}
|
|
|
|
return true;
|
|
}
|
|
|
|
// set min boiler output
|
|
bool Boiler::set_min_power(const char * value, const int8_t id) {
|
|
int v = 0;
|
|
if (!Helpers::value2number(value, v)) {
|
|
LOG_WARNING(F("Set boiler min power: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting boiler min power to %d %%"), v);
|
|
if (get_toggle_fetch(EMS_TYPE_UBAParametersPlus)) {
|
|
write_command(EMS_TYPE_UBAParametersPlus, 5, v, EMS_TYPE_UBAParametersPlus);
|
|
} else {
|
|
write_command(EMS_TYPE_UBAParameters, 3, v, EMS_TYPE_UBAParameters);
|
|
}
|
|
|
|
return true;
|
|
}
|
|
|
|
// set max boiler output
|
|
bool Boiler::set_max_power(const char * value, const int8_t id) {
|
|
int v = 0;
|
|
if (!Helpers::value2number(value, v)) {
|
|
LOG_WARNING(F("Set boiler max power: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting boiler max power to %d %%"), v);
|
|
if (get_toggle_fetch(EMS_TYPE_UBAParametersPlus)) {
|
|
write_command(EMS_TYPE_UBAParametersPlus, 4, v, EMS_TYPE_UBAParametersPlus);
|
|
} else {
|
|
write_command(EMS_TYPE_UBAParameters, 2, v, EMS_TYPE_UBAParameters);
|
|
}
|
|
|
|
return true;
|
|
}
|
|
|
|
// set warm water max power
|
|
bool Boiler::set_warmwater_maxpower(const char * value, const int8_t id) {
|
|
int v = 0;
|
|
if (!Helpers::value2number(value, v)) {
|
|
LOG_WARNING(F("Set warm water max power: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting warm water max power to %d %%"), v);
|
|
write_command(EMS_TYPE_UBASettingsWW, 7, v, EMS_TYPE_UBASettingsWW);
|
|
|
|
return true;
|
|
}
|
|
|
|
// set min pump modulation
|
|
bool Boiler::set_min_pump(const char * value, const int8_t id) {
|
|
int v = 0;
|
|
if (!Helpers::value2number(value, v)) {
|
|
LOG_WARNING(F("Set pump min: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting pump min to %d %%"), v);
|
|
if (get_toggle_fetch(EMS_TYPE_UBAParametersPlus)) {
|
|
write_command(EMS_TYPE_UBAParametersPlus, 14, v, EMS_TYPE_UBAParametersPlus);
|
|
} else {
|
|
write_command(EMS_TYPE_UBAParameters, 10, v, EMS_TYPE_UBAParameters);
|
|
}
|
|
|
|
return true;
|
|
}
|
|
|
|
// set max pump modulation
|
|
bool Boiler::set_max_pump(const char * value, const int8_t id) {
|
|
int v = 0;
|
|
if (!Helpers::value2number(value, v)) {
|
|
LOG_WARNING(F("Set pump max: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting pump max to %d %%"), v);
|
|
if (get_toggle_fetch(EMS_TYPE_UBAParametersPlus)) {
|
|
write_command(EMS_TYPE_UBAParametersPlus, 13, v, EMS_TYPE_UBAParametersPlus);
|
|
} else {
|
|
write_command(EMS_TYPE_UBAParameters, 9, v, EMS_TYPE_UBAParameters);
|
|
}
|
|
|
|
return true;
|
|
}
|
|
|
|
// set boiler on hysteresis
|
|
bool Boiler::set_hyst_on(const char * value, const int8_t id) {
|
|
int v = 0;
|
|
if (!Helpers::value2number(value, v)) {
|
|
LOG_WARNING(F("Set boiler hysteresis: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting boiler hysteresis on to %d C"), v);
|
|
if (get_toggle_fetch(EMS_TYPE_UBAParametersPlus)) {
|
|
write_command(EMS_TYPE_UBAParametersPlus, 9, v, EMS_TYPE_UBAParametersPlus);
|
|
} else {
|
|
write_command(EMS_TYPE_UBAParameters, 5, v, EMS_TYPE_UBAParameters);
|
|
}
|
|
|
|
return true;
|
|
}
|
|
|
|
// set boiler off hysteresis
|
|
bool Boiler::set_hyst_off(const char * value, const int8_t id) {
|
|
int v = 0;
|
|
if (!Helpers::value2number(value, v)) {
|
|
LOG_WARNING(F("Set boiler hysteresis: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting boiler hysteresis off to %d C"), v);
|
|
if (get_toggle_fetch(EMS_TYPE_UBAParametersPlus)) {
|
|
write_command(EMS_TYPE_UBAParametersPlus, 8, v, EMS_TYPE_UBAParametersPlus);
|
|
} else {
|
|
write_command(EMS_TYPE_UBAParameters, 4, v, EMS_TYPE_UBAParameters);
|
|
}
|
|
|
|
return true;
|
|
}
|
|
|
|
// set min burner period
|
|
bool Boiler::set_burn_period(const char * value, const int8_t id) {
|
|
int v = 0;
|
|
if (!Helpers::value2number(value, v)) {
|
|
LOG_WARNING(F("Set burner min. period: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting burner min. period to %d min"), v);
|
|
if (get_toggle_fetch(EMS_TYPE_UBAParametersPlus)) {
|
|
write_command(EMS_TYPE_UBAParametersPlus, 10, v, EMS_TYPE_UBAParametersPlus);
|
|
} else {
|
|
write_command(EMS_TYPE_UBAParameters, 6, v, EMS_TYPE_UBAParameters);
|
|
}
|
|
|
|
return true;
|
|
}
|
|
|
|
// set pump delay
|
|
bool Boiler::set_pump_delay(const char * value, const int8_t id) {
|
|
int v = 0;
|
|
if (!Helpers::value2number(value, v)) {
|
|
LOG_WARNING(F("Set boiler pump delay: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
if (get_toggle_fetch(EMS_TYPE_UBAParameters)) {
|
|
LOG_INFO(F("Setting boiler pump delay to %d min"), v);
|
|
write_command(EMS_TYPE_UBAParameters, 8, v, EMS_TYPE_UBAParameters);
|
|
return true;
|
|
}
|
|
|
|
return false;
|
|
}
|
|
|
|
// note some boilers do not have this setting, than it's done by thermostat
|
|
// on a RC35 it's by EMSESP::send_write_request(0x37, 0x10, 2, &set, 1, 0); (set is 1,2,3) 1=hot, 2=eco, 3=intelligent
|
|
bool Boiler::set_warmwater_mode(const char * value, const int8_t id) {
|
|
uint8_t set;
|
|
if (!Helpers::value2enum(value, set, {F("hot"), F("eco"), F("intelligent")})) {
|
|
LOG_WARNING(F("Set boiler warm water mode: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
if (!get_toggle_fetch(EMS_TYPE_UBAParameterWW)) {
|
|
return false;
|
|
}
|
|
|
|
if (set == 0) {
|
|
LOG_INFO(F("Setting boiler warm water to Hot"));
|
|
} else if (set == 1) {
|
|
LOG_INFO(F("Setting boiler warm water to Eco"));
|
|
set = 0xD8;
|
|
} else if (set == 2) {
|
|
LOG_INFO(F("Setting boiler warm water to Intelligent"));
|
|
set = 0xEC;
|
|
} else {
|
|
return false; // do nothing
|
|
}
|
|
|
|
write_command(EMS_TYPE_UBAParameterWW, 9, set, EMS_TYPE_UBAParameterWW);
|
|
return true;
|
|
}
|
|
|
|
// turn on/off warm water
|
|
bool Boiler::set_warmwater_activated(const char * value, const int8_t id) {
|
|
bool v = false;
|
|
if (!Helpers::value2bool(value, v)) {
|
|
LOG_WARNING(F("Set boiler warm water active: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting boiler warm water active %s"), v ? "on" : "off");
|
|
|
|
// https://github.com/emsesp/EMS-ESP/issues/268
|
|
uint8_t n;
|
|
if (EMSbus::is_ht3()) {
|
|
n = (v ? 0x08 : 0x00); // 0x08 is on, 0x00 is off
|
|
} else {
|
|
n = (v ? 0xFF : 0x00); // 0xFF is on, 0x00 is off
|
|
}
|
|
|
|
if (get_toggle_fetch(EMS_TYPE_UBAParameterWWPlus)) {
|
|
write_command(EMS_TYPE_UBAParameterWWPlus, 1, v ? 1 : 0, EMS_TYPE_UBAParameterWWPlus);
|
|
} else {
|
|
write_command(EMS_TYPE_UBAParameterWW, 1, n, 0x34);
|
|
}
|
|
|
|
return true;
|
|
}
|
|
|
|
// Activate / De-activate the Warm Tap Water
|
|
// Note: Using the type 0x1D to put the boiler into Test mode. This may be shown on the boiler with a flashing 'T'
|
|
bool Boiler::set_tapwarmwater_activated(const char * value, const int8_t id) {
|
|
bool v = false;
|
|
if (!Helpers::value2bool(value, v)) {
|
|
LOG_WARNING(F("Set warm tap water: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting warm tap water %s"), v ? "on" : "off");
|
|
uint8_t message_data[EMS_MAX_TELEGRAM_MESSAGE_LENGTH];
|
|
for (uint8_t i = 0; i < sizeof(message_data); i++) {
|
|
message_data[i] = 0x00;
|
|
}
|
|
|
|
// we use the special test mode 0x1D for this. Setting the first data to 5A puts the system into test mode and
|
|
// a setting of 0x00 puts it back into normal operating mode
|
|
// when in test mode we're able to mess around with the 3-way valve settings
|
|
if (!v) {
|
|
// on
|
|
message_data[0] = 0x5A; // test mode on
|
|
message_data[1] = 0x00; // burner output 0%
|
|
message_data[3] = 0x64; // boiler pump capacity 100%
|
|
message_data[4] = 0xFF; // 3-way valve hot water only
|
|
} else {
|
|
// get out of test mode. Send all zeros.
|
|
// telegram: 0B 08 1D 00 00
|
|
}
|
|
|
|
write_command(EMS_TYPE_UBAFunctionTest, 0, message_data, sizeof(message_data), 0);
|
|
|
|
return true;
|
|
}
|
|
|
|
// Activate / De-activate One Time warm water 0x35
|
|
// true = on, false = off
|
|
// See also https://github.com/emsesp/EMS-ESP/issues/341#issuecomment-596245458 for Junkers
|
|
bool Boiler::set_warmwater_onetime(const char * value, const int8_t id) {
|
|
bool v = false;
|
|
if (!Helpers::value2bool(value, v)) {
|
|
LOG_WARNING(F("Set warm water OneTime loading: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting warm water OneTime loading %s"), v ? "on" : "off");
|
|
if (get_toggle_fetch(EMS_TYPE_UBAParameterWWPlus)) {
|
|
write_command(EMS_TYPE_UBAFlags, 0, (v ? 0x22 : 0x02), 0xE9); // not sure if this is in flags
|
|
} else {
|
|
write_command(EMS_TYPE_UBAFlags, 0, (v ? 0x22 : 0x02), 0x34);
|
|
}
|
|
|
|
return true;
|
|
}
|
|
|
|
// Activate / De-activate circulation of warm water 0x35
|
|
// true = on, false = off
|
|
bool Boiler::set_warmwater_circulation(const char * value, const int8_t id) {
|
|
bool v = false;
|
|
if (!Helpers::value2bool(value, v)) {
|
|
LOG_WARNING(F("Set warm water circulation: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting warm water circulation %s"), v ? "on" : "off");
|
|
if (get_toggle_fetch(EMS_TYPE_UBAParameterWWPlus)) {
|
|
write_command(EMS_TYPE_UBAFlags, 1, (v ? 0x22 : 0x02), 0xE9); // not sure if this is in flags
|
|
} else {
|
|
write_command(EMS_TYPE_UBAFlags, 1, (v ? 0x22 : 0x02), 0x34);
|
|
}
|
|
|
|
return true;
|
|
}
|
|
|
|
// configuration of warm water circulation pump
|
|
bool Boiler::set_warmwater_circulation_pump(const char * value, const int8_t id) {
|
|
bool v = false;
|
|
if (!Helpers::value2bool(value, v)) {
|
|
LOG_WARNING(F("Set warm water circulation pump: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
LOG_INFO(F("Setting warm water circulation pump %s"), v ? "on" : "off");
|
|
|
|
if (get_toggle_fetch(EMS_TYPE_UBAParameterWWPlus)) {
|
|
write_command(EMS_TYPE_UBAParameterWWPlus, 10, v ? 0x01 : 0x00, EMS_TYPE_UBAParameterWWPlus);
|
|
} else {
|
|
write_command(EMS_TYPE_UBAParameterWW, 6, v ? 0xFF : 0x00, EMS_TYPE_UBAParameterWW);
|
|
}
|
|
|
|
return true;
|
|
}
|
|
|
|
// Set the mode of circulation, 1x3min, ... 6x3min, continuos
|
|
// true = on, false = off
|
|
bool Boiler::set_warmwater_circulation_mode(const char * value, const int8_t id) {
|
|
int v = 0;
|
|
if (!Helpers::value2number(value, v)) {
|
|
LOG_WARNING(F("Set warm water circulation mode: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
if (v < 7) {
|
|
LOG_INFO(F("Setting warm water circulation mode %dx3min"), v);
|
|
} else if (v == 7) {
|
|
LOG_INFO(F("Setting warm water circulation mode continuos"));
|
|
} else {
|
|
LOG_WARNING(F("Set warm water circulation mode: Invalid value"));
|
|
return false;
|
|
}
|
|
|
|
if (get_toggle_fetch(EMS_TYPE_UBAParameterWWPlus)) {
|
|
write_command(EMS_TYPE_UBAParameterWWPlus, 11, v, EMS_TYPE_UBAParameterWWPlus);
|
|
} else {
|
|
write_command(EMS_TYPE_UBAParameterWW, 7, v, EMS_TYPE_UBAParameterWW);
|
|
}
|
|
|
|
return true;
|
|
}
|
|
// Reset command
|
|
// 0 & 1 Reset-Mode (Manuel, others)
|
|
// 8 reset maintenance message Hxx
|
|
// 12 & 13 Reset that Error-memory
|
|
bool Boiler::set_reset(const char * value, const int8_t id) {
|
|
std::string s(12, '\0');
|
|
if (!Helpers::value2string(value, s)) {
|
|
return false;
|
|
}
|
|
|
|
if (s == "maintenance") {
|
|
LOG_INFO(F("Reset boiler maintenance message"));
|
|
write_command(0x05, 0x08, 0xFF, 0x1C);
|
|
return true;
|
|
} else if (s == "error") {
|
|
LOG_INFO(F("Reset boiler error message"));
|
|
write_command(0x05, 0x00, 0x5A); // error reset
|
|
return true;
|
|
}
|
|
return false;
|
|
}
|
|
|
|
//maintenance
|
|
bool Boiler::set_maintenance(const char * value, const int8_t id) {
|
|
std::string s(12, '\0');
|
|
if (Helpers::value2string(value, s)) {
|
|
if (s == "reset") {
|
|
LOG_INFO(F("Reset boiler maintenance message"));
|
|
write_command(0x05, 0x08, 0xFF, 0x1C);
|
|
return true;
|
|
}
|
|
}
|
|
|
|
if (strlen(value) == 10) { // date
|
|
uint8_t day = (value[0] - '0') * 10 + (value[1] - '0');
|
|
uint8_t month = (value[3] - '0') * 10 + (value[4] - '0');
|
|
uint8_t year = (uint8_t)(Helpers::atoint(&value[6]) - 2000);
|
|
if (day > 0 && day < 32 && month > 0 && month < 13) {
|
|
LOG_INFO(F("Setting maintenance date to %02d.%02d.%04d"), day, month, year + 2000);
|
|
uint8_t data[5] = {2, (uint8_t)(maintenanceTime_ / 100), day, month, year};
|
|
write_command(0x15, 0, data, 5, 0x15);
|
|
} else {
|
|
LOG_WARNING(F("Setting maintenance: wrong format %d.%d.%d"), day, month, year + 2000);
|
|
return false;
|
|
}
|
|
return true;
|
|
}
|
|
|
|
int hrs;
|
|
if (Helpers::value2number(value, hrs)) {
|
|
if (hrs > 99 && hrs < 25600) {
|
|
LOG_INFO(F("Setting maintenance time %d hours"), hrs);
|
|
uint8_t data[2] = {1, (uint8_t)(hrs / 100)};
|
|
write_command(0x15, 0, data, 2, 0x15);
|
|
return true;
|
|
}
|
|
}
|
|
|
|
uint8_t num;
|
|
if (Helpers::value2enum(value, num, {F("off"), F("time"), F("date")})) {
|
|
LOG_INFO(F("Setting maintenance type to %s"), value);
|
|
write_command(0x15, 0, num, 0x15);
|
|
return true;
|
|
}
|
|
|
|
LOG_WARNING(F("Setting maintenance: wrong format"));
|
|
return false;
|
|
}
|
|
|
|
} // namespace emsesp
|