[1.2.1] 2019-01-02
Fixed
- Only process broadcast messages if the offset (byte 4) is 0. (https://github.com/proddy/EMS-ESP-Boiler/issues/23)
- Improved checking for duplicate sent Tx telegrams by comparing CRCs
- Removed distiquishing between noise on the line and corrupt telegrams (https://github.com/proddy/EMS-ESP-Boiler/issues/24)
[1.2.0] 2019-01-01
Fixed
- Incorrect indenting in
climate.yaml(thanks @mrfixit1) - Improved support for slower WiFi connections
- Fixed issue with OTA not always giving back a completion response to platformio
- Fixed issue with repeating reads after a raw mode send
- Fixed handling of long integers (thanks @SpaceTeddy)
Added
- added 'dout' flashmode to platformio.ini so OTA works now when uploading to a Wemos D1 Pro's or any other board with larger flash's
- added un tested supporting RC35 type of thermostats
- Try and discover and set Boiler and Thermostat types automatically
- Fetch UBATotalUptimeMessage from Boiler to get total working minutes
- Added check to see if bus is connected. Shown in stats page
- If no Wifi connection can be made, start up as a WiFi Access Point (AP)
- Report out service codes and water-flow pull-request. Thanks @Bonusbartus
Changed
- Build option is called
DEBUG_SUPPORT(wasUSE_SERIAL) - Replaced old ESPHelper with my own MyESP library to handle Wifi, MQTT, MDNS and Telnet handlers. Supports asynchronous TCP and has smaller memory footprint. And moved to libs directory.
- Simplified LED error checking. If enabled (by default), solid means connected and flashing means error. Uses either an external pull-up or the onboard ESP8266 LED.
- Improved Telnet debugging which uses TelnetSpy to keep a buffer of previous output
- Optimized memory usage & heap conflicts, removing nasty things like strcpy, sprintf where possible
- Improved checking for tap water on/off (thanks @Bonusbartus)
Removed
- Time and TimeLib's. Not used in code.
- Removed build option
MQTT_MAX_PACKAGE_SIZEas not using the PubSubClient library any more - Removed all of Espurna's pre-built firmwares and instructions to build. Keeping it simple.
[1.1.1] 2018-12-23
Removed
- Espurna build notes and ready made firmware
[1.1.0] 2018-12-22
Fixed
- Fixed handling of negative floating point values (like outdoor temp)
- Fixed handling of auto & manual mode on an RC30
- Fixed condition where all telegram types were processed, instead of only broadcasts or our own reads
Added
- Created this CHANGELOG.md file!
- Added support for the Nefit Easy thermostat, reading of temperature values only - note read only (big thanks @kroon040 for lending me an Easy device)
- Added support for RC35/Moduline 400 - read only
- New raw logging mode for logging
- New 'r'command to send raw data to EMS
- Added MQTT messages for hot water on and heating on
- Implemented FIFO circular buffer queue for up to 20 Tx messages (Q command to show queue)
- Toggle Tx transmission via telnet (use 'X' command)
- Show thermostat type in help stats (use 's' command)
- Show version is help stats (use '?' command)
Changed
- Improved overall formatting of logging
- Include app name and version in telnet help
- Improved method to switch off hot tap water in Shower Alert
- Telnet P and M commands have changed
- Enabling Logging in telnet is now the 'l' command
- Logging is set back to None when telnet session closes
- Improved fetching of initial boiler values to post to MQTT at startup
- Improved handling and retrying of write/Tx commands
Removed
- Hid access from telnet to the Experimental custom function command 'x'
- Tx and Rx stats have gone from the stats page, as they were pretty meaningless
- Removed NO_TX define in platformio and replaced with system parameter 'command X'
- Removed -DDEBUG option in build
- Removed wwtemp MQTT messages to set the boiler temp. You'll never miss it.
- Removed LEDs for Tx, Rx and Err. Too many flashing lights and it drains the current.
- Removed capturing of last Rx and Tx times
- Support for older RC20 thermostats
Known Issues
- There's a nasty memory leek when in telnet's verbose mode with sending which causes the EMS to reset when running for a while.
[1.0.1] 2018-09-24
- Initial stable version
[0.1.0] 2018-05-14
- Initial development version