* EMS-ESP - https://github.com/proddy/EMS-ESP
* Copyright 2019 Paul Derbyshire
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <http://www.gnu.org/licenses/>.
*/
#include "boiler.h"
namespace emsesp {
REGISTER_FACTORY(Boiler, EMSdevice::DeviceType::BOILER)
uuid::log::Logger Boiler::logger_{F_(boiler), uuid::log::Facility::CONSOLE};
Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const std::string & version, const std::string & name, uint8_t flags, uint8_t brand)
: EMSdevice(device_type, device_id, product_id, version, name, flags, brand) {
this->reserve_mem(20); // reserve some space for the telegram registries, to avoid memory fragmentation
LOG_DEBUG(F("Adding new Boiler with device ID 0x%02X"), device_id);
// the telegram handlers...
register_telegram_type(0x10, F("UBAErrorMessage1"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAErrorMessage(t); });
register_telegram_type(0x11, F("UBAErrorMessage2"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAErrorMessage(t); });
register_telegram_type(0x18, F("UBAMonitorFast"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMonitorFast(t); });
register_telegram_type(0x19, F("UBAMonitorSlow"), true, [&](std::shared_ptr<const Telegram> t) { process_UBAMonitorSlow(t); });
register_telegram_type(0x34, F("UBAMonitorWW"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMonitorWW(t); });
register_telegram_type(0x1C, F("UBAMaintenanceStatus"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMaintenanceStatus(t); });
register_telegram_type(0x2A, F("MC10Status"), false, [&](std::shared_ptr<const Telegram> t) { process_MC10Status(t); });
register_telegram_type(0x33, F("UBAParameterWW"), true, [&](std::shared_ptr<const Telegram> t) { process_UBAParameterWW(t); });
register_telegram_type(0x14, F("UBATotalUptime"), false, [&](std::shared_ptr<const Telegram> t) { process_UBATotalUptime(t); });
register_telegram_type(0x35, F("UBAFlags"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAFlags(t); });
register_telegram_type(0x15, F("UBAMaintenanceData"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMaintenanceData(t); });
register_telegram_type(0x16, F("UBAParameters"), true, [&](std::shared_ptr<const Telegram> t) { process_UBAParameters(t); });
register_telegram_type(0x1A, F("UBASetPoints"), false, [&](std::shared_ptr<const Telegram> t) { process_UBASetPoints(t); });
register_telegram_type(0xD1, F("UBAOutdoorTemp"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAOutdoorTemp(t); });
register_telegram_type(0xE3, F("UBAMonitorSlowPlus"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMonitorSlowPlus2(t); });
register_telegram_type(0xE4, F("UBAMonitorFastPlus"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMonitorFastPlus(t); });
register_telegram_type(0xE5, F("UBAMonitorSlowPlus"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMonitorSlowPlus(t); });
register_telegram_type(0xE9, F("UBADHWStatus"), false, [&](std::shared_ptr<const Telegram> t) { process_UBADHWStatus(t); });
// MQTT commands for boiler_cmd topic
register_mqtt_cmd(F("comfort"), [&](const char * value, const int8_t id) { set_warmwater_mode(value, id); });
register_mqtt_cmd(F("wwactivated"), [&](const char * value, const int8_t id) { set_warmwater_activated(value, id); });
register_mqtt_cmd(F("wwtapactivated"), [&](const char * value, const int8_t id) { set_tapwarmwater_activated(value, id); });
register_mqtt_cmd(F("wwonetime"), [&](const char * value, const int8_t id) { set_warmwater_onetime(value, id); });
register_mqtt_cmd(F("wwcirculation"), [&](const char * value, const int8_t id) { set_warmwater_circulation(value, id); });
register_mqtt_cmd(F("flowtemp"), [&](const char * value, const int8_t id) { set_flow_temp(value, id); });
register_mqtt_cmd(F("wwtemp"), [&](const char * value, const int8_t id) { set_warmwater_temp(value, id); });
register_mqtt_cmd(F("burnmaxpower"), [&](const char * value, const int8_t id) { set_max_power(value, id); });
register_mqtt_cmd(F("burnminpower"), [&](const char * value, const int8_t id) { set_min_power(value, id); });
register_mqtt_cmd(F("boilhyston"), [&](const char * value, const int8_t id) { set_hyst_on(value, id); });
register_mqtt_cmd(F("boilhystoff"), [&](const char * value, const int8_t id) { set_hyst_off(value, id); });
register_mqtt_cmd(F("burnperiod"), [&](const char * value, const int8_t id) { set_burn_period(value, id); });
register_mqtt_cmd(F("pumpdelay"), [&](const char * value, const int8_t id) { set_pump_delay(value, id); });
}
// add submenu context
void Boiler::add_context_menu() {
EMSESPShell::commands->add_command(ShellContext::MAIN,
CommandFlags::USER,
flash_string_vector{F_(boiler)},
[&](Shell & shell, const std::vector<std::string> & arguments __attribute__((unused))) {
Boiler::console_commands(shell, ShellContext::BOILER);
add_context_commands(ShellContext::BOILER);
});
}
void Boiler::device_info(JsonArray & root) {
JsonObject dataElement;
if (Helpers::hasValue(tap_water_active_, EMS_VALUE_BOOL)) {
dataElement = root.createNestedObject();
dataElement["name"] = F("Hot tap water");
dataElement["value"] = tap_water_active_ ? F("running") : F("off");
}
if (Helpers::hasValue(heating_active_, EMS_VALUE_BOOL)) {
dataElement = root.createNestedObject();
dataElement["name"] = F("Central heating");
dataElement["value"] = heating_active_ ? F("active") : F("off");
}
render_value_json(root, "", F("Selected flow temperature"), selFlowTemp_, F_(degrees));
render_value_json(root, "", F("Current flow temperature"), curFlowTemp_, F_(degrees), 10);
render_value_json(root, "", F("Warm Water selected temperature"), wWSelTemp_, F_(degrees));
render_value_json(root, "", F("Warm Water set temperature"), wWSetTmp_, F_(degrees));
render_value_json(root, "", F("Warm Water current temperature (intern)"), wWCurTmp_, F_(degrees), 10);
render_value_json(root, "", F("Warm Water current temperature (extern)"), wWCurTmp2_, F_(degrees), 10);
}
// publish values via MQTT
void Boiler::publish_values() {
// const size_t capacity = JSON_OBJECT_SIZE(56); // must recalculate if more objects addded https://arduinojson.org/v6/assistant/
// DynamicJsonDocument doc(capacity);
StaticJsonDocument<EMSESP_MAX_JSON_SIZE_LARGE> doc;
char s[10]; // for formatting strings
if (Helpers::hasValue(wWComfort_)) {
if (wWComfort_ == 0x00) {
doc["wWComfort"] = "Hot";
} else if (wWComfort_ == 0xD8) {
doc["wWComfort"] = "Eco";
} else if (wWComfort_ == 0xEC) {
doc["wWComfort"] = "Intelligent";
}
}
if (Helpers::hasValue(wWSelTemp_)) {
doc["wWSelTemp"] = wWSelTemp_;
}
if (Helpers::hasValue(wWSetTmp_)) {
doc["wWSetTemp"] = wWSetTmp_;
}
if (Helpers::hasValue(wWDisinfectTemp_)) {
doc["wWDisinfectionTemp"] = wWDisinfectTemp_;
}
if (Helpers::hasValue(selFlowTemp_)) {
doc["selFlowTemp"] = selFlowTemp_;
}
if (Helpers::hasValue(selBurnPow_)) {
doc["selBurnPow"] = selBurnPow_;
}
if (Helpers::hasValue(curBurnPow_)) {
doc["curBurnPow"] = curBurnPow_;
}
if (Helpers::hasValue(pumpMod_)) {
doc["pumpMod"] = pumpMod_;
}
if (Helpers::hasValue(pumpMod2_)) {
doc["pumpMod2"] = pumpMod2_;
}
if (Helpers::hasValue(wWCircPump_, EMS_VALUE_BOOL)) {
doc["wWCircPump"] = Helpers::render_value(s, wWCircPump_, EMS_VALUE_BOOL);
}
if (Helpers::hasValue(wWCircPumpType_, EMS_VALUE_BOOL)) {
doc["wWCiPuType"] = wWCircPumpType_ ? "valve" : "pump";
}
if (Helpers::hasValue(wWCircPumpMode_)) {
doc["wWCiPuMode"] = wWCircPumpMode_;
}
if (Helpers::hasValue(wWCirc_, EMS_VALUE_BOOL)) {
doc["wWCirc"] = Helpers::render_value(s, wWCirc_, EMS_VALUE_BOOL);
}
if (Helpers::hasValue(extTemp_)) {
doc["outdoorTemp"] = (float)extTemp_ / 10;
}
if (Helpers::hasValue(wWCurTmp_)) {
doc["wWCurTmp"] = (float)wWCurTmp_ / 10;
}
if (Helpers::hasValue(wWCurTmp2_)) {
doc["wWCurTmp2"] = (float)wWCurTmp2_ / 10;
}
if (Helpers::hasValue(wWCurFlow_)) {
doc["wWCurFlow"] = (float)wWCurFlow_ / 10;
}
if (Helpers::hasValue(curFlowTemp_)) {
doc["curFlowTemp"] = (float)curFlowTemp_ / 10;
}
if (Helpers::hasValue(retTemp_)) {
doc["retTemp"] = (float)retTemp_ / 10;
}
if (Helpers::hasValue(switchTemp_)) {
doc["switchTemp"] = (float)switchTemp_ / 10;
}
if (Helpers::hasValue(sysPress_)) {
doc["sysPress"] = (float)sysPress_ / 10;
}
if (Helpers::hasValue(boilTemp_)) {
doc["boilTemp"] = (float)boilTemp_ / 10;
}
if (Helpers::hasValue(wwStorageTemp1_)) {
doc["wwStorageTemp1"] = (float)wwStorageTemp1_ / 10;
}
if (Helpers::hasValue(wwStorageTemp2_)) {
doc["wwStorageTemp2"] = (float)wwStorageTemp2_ / 10;
}
if (Helpers::hasValue(exhaustTemp_)) {
doc["exhaustTemp"] = (float)exhaustTemp_ / 10;
}
if (Helpers::hasValue(wWActivated_, EMS_VALUE_BOOL)) {
doc["wWActivated"] = Helpers::render_value(s, wWActivated_, EMS_VALUE_BOOL);
}
if (Helpers::hasValue(wWOneTime_, EMS_VALUE_BOOL)) {
doc["wWOnetime"] = Helpers::render_value(s, wWOneTime_, EMS_VALUE_BOOL);
}
if (Helpers::hasValue(wWDesinfecting_, EMS_VALUE_BOOL)) {
doc["wWDesinfecting"] = Helpers::render_value(s, wWDesinfecting_, EMS_VALUE_BOOL);
}
if (Helpers::hasValue(wWReadiness_, EMS_VALUE_BOOL)) {
doc["wWReady"] = Helpers::render_value(s, wWReadiness_, EMS_VALUE_BOOL);
}
if (Helpers::hasValue(wWRecharging_, EMS_VALUE_BOOL)) {
doc["wWRecharge"] = Helpers::render_value(s, wWRecharging_, EMS_VALUE_BOOL);
}
if (Helpers::hasValue(wWTemperatureOK_, EMS_VALUE_BOOL)) {
doc["wWTempOK"] = Helpers::render_value(s, wWTemperatureOK_, EMS_VALUE_BOOL);
}
if (Helpers::hasValue(wWCirc_, EMS_VALUE_BOOL)) {
doc["wWCirc"] = Helpers::render_value(s, wWCirc_, EMS_VALUE_BOOL);
}
if (Helpers::hasValue(burnGas_, EMS_VALUE_BOOL)) {
doc["burnGas"] = Helpers::render_value(s, burnGas_, EMS_VALUE_BOOL);
}
if (Helpers::hasValue(flameCurr_)) {
doc["flameCurr"] = (float)(int16_t)flameCurr_ / 10;
}
if (Helpers::hasValue(heatPmp_, EMS_VALUE_BOOL)) {
doc["heatPump"] = Helpers::render_value(s, heatPmp_, EMS_VALUE_BOOL);
}
if (Helpers::hasValue(fanWork_, EMS_VALUE_BOOL)) {
doc["fanWork"] = Helpers::render_value(s, fanWork_, EMS_VALUE_BOOL);
}
if (Helpers::hasValue(ignWork_, EMS_VALUE_BOOL)) {
doc["ignWork"] = Helpers::render_value(s, ignWork_, EMS_VALUE_BOOL);
}
if (Helpers::hasValue(wWHeat_, EMS_VALUE_BOOL)) {
doc["wWHeat"] = Helpers::render_value(s, wWHeat_, EMS_VALUE_BOOL);
}
if (Helpers::hasValue(heating_temp_)) {
doc["heatingTemp"] = heating_temp_;
}
if (Helpers::hasValue(pump_mod_max_)) {
doc["pumpModMax"] = pump_mod_max_;
}
if (Helpers::hasValue(pump_mod_min_)) {
doc["pumpModMin"] = pump_mod_min_;
}
if (Helpers::hasValue(pumpDelay_)) {
doc["pumpDelay"] = pumpDelay_;
}
if (Helpers::hasValue(burnPeriod_)) {
doc["burnMinPeriod"] = burnPeriod_;
}
if (Helpers::hasValue(burnPowermin_)) {
doc["burnMinPower"] = burnPowermin_;
}
if (Helpers::hasValue(burnPowermax_)) {
doc["burnMaxPower"] = burnPowermax_;
}
if (Helpers::hasValue(boilTemp_on_)) {
doc["boilHystOn"] = boilTemp_on_;
}
if (Helpers::hasValue(boilTemp_off_)) {
doc["boilHystOff"] = boilTemp_off_;
}
if (Helpers::hasValue(setFlowTemp_)) {
doc["setFlowTemp"] = setFlowTemp_;
}
if (Helpers::hasValue(setWWPumpPow_)) {
doc["wWSetPumpPower"] = setWWPumpPow_;
}
if (Helpers::hasValue(wWStarts_)) {
doc["wWStarts"] = wWStarts_;
}
if (Helpers::hasValue(wWWorkM_)) {
doc["wWWorkM"] = wWWorkM_;
}
if (Helpers::hasValue(UBAuptime_)) {
doc["UBAuptime"] = UBAuptime_;
}
if (Helpers::hasValue(burnStarts_)) {
doc["burnStarts"] = burnStarts_;
}
if (Helpers::hasValue(burnWorkMin_)) {
doc["burnWorkMin"] = burnWorkMin_;
}
if (Helpers::hasValue(heatWorkMin_)) {
doc["heatWorkMin"] = heatWorkMin_;
}
if (Helpers::hasValue(serviceCode_)) {
doc["serviceCode"] = serviceCodeChar_;
doc["serviceCodeNumber"] = serviceCode_;
}
// if we have data, publish it
if (!doc.isNull()) {
Mqtt::publish("boiler_data", doc);
}
}
// called after a process command is called, to check values and see if we need to force an MQTT publish
bool Boiler::updated_values() {
return false;
}
// print values to shell console
void Boiler::show_values(uuid::console::Shell & shell) {
EMSdevice::show_values(shell); // for showing the header
if (Helpers::hasValue(tap_water_active_, EMS_VALUE_BOOL)) {
print_value(shell, 2, F("Hot tap water"), tap_water_active_ ? F("running") : F("off"));
}
if (Helpers::hasValue(heating_active_, EMS_VALUE_BOOL)) {
print_value(shell, 2, F("Central heating"), heating_active_ ? F("active") : F("off"));
}
print_value(shell, 2, F("Warm Water activated"), wWActivated_, nullptr, EMS_VALUE_BOOL);
if (Helpers::hasValue(wWCircPumpType_, EMS_VALUE_BOOL)) {
print_value(shell, 2, F("Warm Water charging type"), wWCircPumpType_ ? F("3-way valve") : F("charge pump"));
}
print_value(shell, 2, F("Warm Water circulation pump available"), wWCircPump_, nullptr, EMS_VALUE_BOOL);
if (Helpers::hasValue(wWCircPumpMode_)) {
if (wWCircPumpMode_ == 7) {
print_value(shell, 2, F("Warm Water circulation pump freq"), F("continuous"));
} else {
char s[7];
char buffer[2];
buffer[0] = (wWCircPumpMode_ % 10) + '0';
buffer[1] = '\0';
strlcpy(s, buffer, 7);
strlcat(s, "x3min", 7);
print_value(shell, 2, F("Warm Water circulation pump freq"), s);
}
}
print_value(shell, 2, F("Warm Water circulation active"), wWCirc_, nullptr, EMS_VALUE_BOOL);
if (wWComfort_ == 0x00) {
print_value(shell, 2, F("Warm Water comfort setting"), F("Hot"));
} else if (wWComfort_ == 0xD8) {
print_value(shell, 2, F("Warm Water comfort setting"), F("Eco"));
} else if (wWComfort_ == 0xEC) {
print_value(shell, 2, F("Warm Water comfort setting"), F("Intelligent"));
}
print_value(shell, 2, F("Warm water mix temperature"), wwMixTemperature_, F_(degrees), 10);
print_value(shell, 2, F("Warm water buffer boiler temperature"), wwBufferBoilerTemperature_, F_(degrees), 10);
print_value(shell, 2, F("Warm Water disinfection temperature"), wWDisinfectTemp_, F_(degrees));
print_value(shell, 2, F("Warm Water selected temperature"), wWSelTemp_, F_(degrees));
print_value(shell, 2, F("Warm Water set temperature"), wWSetTmp_, F_(degrees));
print_value(shell, 2, F("Warm Water current temperature (intern)"), wWCurTmp_, F_(degrees), 10);
print_value(shell, 2, F("Warm water storage temperature (intern)"), wwStorageTemp1_, F_(degrees), 10);
print_value(shell, 2, F("Warm Water current temperature (extern)"), wWCurTmp2_, F_(degrees), 10);
print_value(shell, 2, F("Warm water storage temperature (extern)"), wwStorageTemp2_, F_(degrees), 10);
print_value(shell, 2, F("Warm Water current tap water flow"), wWCurFlow_, F("l/min"), 10);
print_value(shell, 2, F("Warm Water # starts"), wWStarts_, nullptr);
if (Helpers::hasValue(wWWorkM_)) {
shell.printfln(F(" Warm Water active time: %d days %d hours %d minutes"), wWWorkM_ / 1440, (wWWorkM_ % 1440) / 60, wWWorkM_ % 60);
}
print_value(shell, 2, F("Warm Water charging"), wWHeat_, nullptr, EMS_VALUE_BOOL);
print_value(shell, 2, F("Warm Water disinfecting"), wWDesinfecting_, nullptr, EMS_VALUE_BOOL);
print_value(shell, 2, F("Selected flow temperature"), selFlowTemp_, F_(degrees));
print_value(shell, 2, F("Current flow temperature"), curFlowTemp_, F_(degrees), 10);
print_value(shell, 2, F("Max boiler temperature"), boilTemp_, F_(degrees), 10);
print_value(shell, 2, F("Return temperature"), retTemp_, F_(degrees), 10);
print_value(shell, 2, F("Gas"), burnGas_, nullptr, EMS_VALUE_BOOL);
print_value(shell, 2, F("Boiler pump"), heatPmp_, nullptr, EMS_VALUE_BOOL);
print_value(shell, 2, F("Fan"), fanWork_, nullptr, EMS_VALUE_BOOL);
print_value(shell, 2, F("Ignition"), ignWork_, nullptr, EMS_VALUE_BOOL);
print_value(shell, 2, F("Burner selected max power"), selBurnPow_, F_(percent));
print_value(shell, 2, F("Burner current power"), curBurnPow_, F_(percent));
print_value(shell, 2, F("Flame current"), flameCurr_, F("uA"), 10);
print_value(shell, 2, F("System pressure"), sysPress_, F("bar"), 10);
if (Helpers::hasValue(serviceCode_)) {
shell.printfln(F(" System service code: %s (%d)"), serviceCodeChar_, serviceCode_);
} else if (serviceCodeChar_[0] != '\0') {
print_value(shell, 2, F("System service code"), serviceCodeChar_);
}
// UBAParameters
print_value(shell, 2, F("Heating temperature setting on the boiler"), heating_temp_, F_(degrees));
print_value(shell, 2, F("Boiler circuit pump modulation max power"), pump_mod_max_, F_(percent));
print_value(shell, 2, F("Boiler circuit pump modulation min power"), pump_mod_min_, F_(percent));
print_value(shell, 2, F("Boiler circuit pump delay time"), pumpDelay_, F("min"));
print_value(shell, 2, F("Boiler temp hysteresis on"), boilTemp_on_, F_(degrees));
print_value(shell, 2, F("Boiler temp hysteresis off"), boilTemp_off_, F_(degrees));
print_value(shell, 2, F("Boiler burner min period"), burnPeriod_, F("min"));
print_value(shell, 2, F("Boiler burner min power"), burnPowermin_, F_(percent));
print_value(shell, 2, F("Boiler burner max power"), burnPowermax_, F_(percent));
// UBASetPoint - these may differ from the above
print_value(shell, 2, F("Set Flow temperature"), setFlowTemp_, F_(degrees));
print_value(shell, 2, F("Boiler burner set power"), setBurnPow_, F_(percent));
print_value(shell, 2, F("Warm Water pump set power"), setWWPumpPow_, F_(percent));
// UBAMonitorSlow
if (Helpers::hasValue(extTemp_)) {
print_value(shell, 2, F("Outside temperature"), extTemp_, F_(degrees), 10);
}
print_value(shell, 2, F("Exhaust temperature"), exhaustTemp_, F_(degrees), 10);
print_value(shell, 2, F("Pump modulation"), pumpMod_, F_(percent));
print_value(shell, 2, F("Pump modulation2"), pumpMod2_, F_(percent));
print_value(shell, 2, F("Burner # starts"), burnStarts_, nullptr);
if (Helpers::hasValue(burnWorkMin_)) {
shell.printfln(F(" Total burner operating time: %d days %d hours %d minutes"), burnWorkMin_ / 1440, (burnWorkMin_ % 1440) / 60, burnWorkMin_ % 60);
}
if (Helpers::hasValue(heatWorkMin_)) {
shell.printfln(F(" Total heat operating time: %d days %d hours %d minutes"), heatWorkMin_ / 1440, (heatWorkMin_ % 1440) / 60, heatWorkMin_ % 60);
}
if (Helpers::hasValue(UBAuptime_)) {
shell.printfln(F(" Total UBA working time: %d days %d hours %d minutes"), UBAuptime_ / 1440, (UBAuptime_ % 1440) / 60, UBAuptime_ % 60);
}
shell.println();
}
/*
* Check if hot tap water or heating is active
* If a value has changed, post it immediately to MQTT so we get real time data
*/
void Boiler::check_active() {
// hot tap water, using flow to check instead of the burner power
// send these values back to the main EMSESP, so other classes (e.g. Shower) can use it
if (Helpers::hasValue(wWCurFlow_) && Helpers::hasValue(burnGas_)) {
tap_water_active_ = ((wWCurFlow_ != 0) && (burnGas_ != EMS_VALUE_BOOL_OFF));
EMSESP::tap_water_active(tap_water_active_);
}
// heating
// using a quick hack for checking the heating by looking at the Selected Flow Temp, but doesn't work for all boilers apparently
if (Helpers::hasValue(selFlowTemp_) && Helpers::hasValue(burnGas_)) {
heating_active_ = (!tap_water_active_ && ((selFlowTemp_ >= EMS_BOILER_SELFLOWTEMP_HEATING) && (burnGas_ != EMS_VALUE_BOOL_OFF)));
}
// see if the heating or hot tap water has changed, if so send
// last_boilerActive stores heating in bit 1 and tap water in bit 2
if (Helpers::hasValue(tap_water_active_, EMS_VALUE_BOOL) && Helpers::hasValue(heating_active_, EMS_VALUE_BOOL)) {
uint8_t latest_boilerState = (tap_water_active_ << 1) + heating_active_;
if (latest_boilerState != last_boilerState) {
last_boilerState = latest_boilerState;
Mqtt::publish("tapwater_active", tap_water_active_);
Mqtt::publish("heating_active", heating_active_);
}
}
}
// 0x33
void Boiler::process_UBAParameterWW(std::shared_ptr<const Telegram> telegram) {
telegram->read_value(wWActivated_, 1); // 0xFF means on
telegram->read_value(wWCircPump_, 6); // 0xFF means on
telegram->read_value(wWCircPumpMode_, 7); // 1=1x3min... 6=6x3min, 7=continuous
telegram->read_value(wWCircPumpType_, 10); // 0 = charge pump, 0xff = 3-way valve
telegram->read_value(wWSelTemp_, 2);
telegram->read_value(wWDisinfectTemp_, 8);
telegram->read_value(wWComfort_, 9);
}
// 0x18
void Boiler::process_UBAMonitorFast(std::shared_ptr<const Telegram> telegram) {
telegram->read_value(selFlowTemp_, 0);
telegram->read_value(curFlowTemp_, 1);
telegram->read_value(selBurnPow_, 3); // burn power max setting
telegram->read_value(curBurnPow_, 4);
telegram->read_bitvalue(burnGas_, 7, 0);
telegram->read_bitvalue(fanWork_, 7, 2);
telegram->read_bitvalue(ignWork_, 7, 3);
telegram->read_bitvalue(heatPmp_, 7, 5);
telegram->read_bitvalue(wWHeat_, 7, 6);
telegram->read_bitvalue(wWCirc_, 7, 7);
// warm water storage sensors (if present)
// wwStorageTemp2 is also used by some brands as the boiler temperature - see https://github.com/proddy/EMS-ESP/issues/206
telegram->read_value(wwStorageTemp1_, 9); // 0x8300 if not available
telegram->read_value(wwStorageTemp2_, 11); // 0x8000 if not available - this is boiler temp
telegram->read_value(retTemp_, 13);
telegram->read_value(flameCurr_, 15);
telegram->read_value(serviceCode_, 20);
// system pressure. FF means missing
telegram->read_value(sysPress_, 17); // is *10
// read the service code / installation status as appears on the display
if ((telegram->message_length > 18) && (telegram->offset == 0)) {
serviceCodeChar_[0] = char(telegram->message_data[18]); // ascii character 1
serviceCodeChar_[1] = char(telegram->message_data[19]); // ascii character 2
serviceCodeChar_[2] = '\0'; // null terminate string
}
// at this point do a quick check to see if the hot water or heating is active
check_active();
}
/*
* UBATotalUptime - type 0x14 - total uptime
* received only after requested (not broadcasted)
*/
void Boiler::process_UBATotalUptime(std::shared_ptr<const Telegram> telegram) {
telegram->read_value(UBAuptime_, 0, 3); // force to 3 bytes
}
/*
* UBAParameters - type 0x16
*/
void Boiler::process_UBAParameters(std::shared_ptr<const Telegram> telegram) {
telegram->read_value(heating_temp_, 1);
telegram->read_value(burnPowermax_, 2);
telegram->read_value(burnPowermin_, 3);
telegram->read_value(boilTemp_off_, 4);
telegram->read_value(boilTemp_on_, 5);
telegram->read_value(burnPeriod_, 6);
telegram->read_value(pumpDelay_, 8);
telegram->read_value(pump_mod_max_, 9);
telegram->read_value(pump_mod_min_, 10);
}
/*
* UBAMonitorWW - type 0x34 - warm water monitor. 19 bytes long
* received every 10 seconds
*/
void Boiler::process_UBAMonitorWW(std::shared_ptr<const Telegram> telegram) {
telegram->read_value(wWSetTmp_, 0);
telegram->read_value(wWCurTmp_, 1);
telegram->read_value(wWCurTmp2_, 3);
telegram->read_value(wWCurFlow_, 9);
telegram->read_value(wWWorkM_, 10, 3); // force to 3 bytes
telegram->read_value(wWStarts_, 13, 3); // force to 3 bytes
telegram->read_bitvalue(wWOneTime_, 5, 1);
telegram->read_bitvalue(wWDesinfecting_, 5, 2);
telegram->read_bitvalue(wWReadiness_, 5, 3);
telegram->read_bitvalue(wWRecharging_, 5, 4);
telegram->read_bitvalue(wWTemperatureOK_, 5, 5);
}
/*
* UBAMonitorFastPlus - type 0xE4 - central heating monitor EMS+
* Still to figure out are: serviceCode, retTemp, sysPress
*/
void Boiler::process_UBAMonitorFastPlus(std::shared_ptr<const Telegram> telegram) {
telegram->read_value(selFlowTemp_, 6);
telegram->read_bitvalue(burnGas_, 11, 0);
telegram->read_bitvalue(wWHeat_, 11, 2);
telegram->read_value(curBurnPow_, 10);
telegram->read_value(selBurnPow_, 9);
telegram->read_value(curFlowTemp_, 7);
telegram->read_value(flameCurr_, 19);
// read the service code / installation status as appears on the display
if ((telegram->message_length > 4) && (telegram->offset == 0)) {
serviceCodeChar_[0] = char(telegram->message_data[4]); // ascii character 1
serviceCodeChar_[1] = char(telegram->message_data[5]); // ascii character 2
serviceCodeChar_[2] = '\0';
}
// at this point do a quick check to see if the hot water or heating is active
check_active();
}
/*
* UBAMonitorSlow - type 0x19 - central heating monitor part 2 (27 bytes long)
* received every 60 seconds
* e.g. 08 00 19 00 80 00 02 41 80 00 00 00 00 00 03 91 7B 05 B8 40 00 00 00 04 92 AD 00 5E EE 80 00
* 08 0B 19 00 FF EA 02 47 80 00 00 00 00 62 03 CA 24 2C D6 23 00 00 00 27 4A B6 03 6E 43
* 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 17 19 20 21 22 23 24
*/
void Boiler::process_UBAMonitorSlow(std::shared_ptr<const Telegram> telegram) {
telegram->read_value(extTemp_, 0);
telegram->read_value(boilTemp_, 2);
telegram->read_value(exhaustTemp_, 4);
telegram->read_value(switchTemp_, 25); // only if there is a mixing module present
telegram->read_value(pumpMod_, 9);
telegram->read_value(burnStarts_, 10, 3); // force to 3 bytes
telegram->read_value(burnWorkMin_, 13, 3); // force to 3 bytes
telegram->read_value(heatWorkMin_, 19, 3); // force to 3 bytes
}
/*
* UBAMonitorSlowPlus2 - type 0xE3
*/
void Boiler::process_UBAMonitorSlowPlus2(std::shared_ptr<const Telegram> telegram) {
telegram->read_value(pumpMod2_, 13);
}
/*
* UBAMonitorSlowPlus - type 0xE5 - central heating monitor EMS+
*/
void Boiler::process_UBAMonitorSlowPlus(std::shared_ptr<const Telegram> telegram) {
telegram->read_bitvalue(fanWork_, 2, 2);
telegram->read_bitvalue(ignWork_, 2, 3);
telegram->read_bitvalue(heatPmp_, 2, 5);
telegram->read_bitvalue(wWCirc_, 2, 7);
telegram->read_value(burnStarts_, 10, 3); // force to 3 bytes
telegram->read_value(burnWorkMin_, 13, 3); // force to 3 bytes
telegram->read_value(heatWorkMin_, 19, 3); // force to 3 bytes
telegram->read_value(pumpMod_, 25);
}
// 0xE9 - DHW Status
// e.g. 08 00 E9 00 37 01 F6 01 ED 00 00 00 00 41 3C 00 00 00 00 00 00 00 00 00 00 00 00 37 00 00 00 (CRC=77) #data=27
void Boiler::process_UBADHWStatus(std::shared_ptr<const Telegram> telegram) {
telegram->read_value(wWSetTmp_, 0);
telegram->read_value(wWCurTmp_, 1);
telegram->read_value(wWCurTmp2_, 3);
telegram->read_value(wWWorkM_, 17, 3); // force to 3 bytes
telegram->read_value(wWStarts_, 14, 3); // force to 3 bytes
telegram->read_bitvalue(wWOneTime_, 12, 2);
telegram->read_bitvalue(wWDesinfecting_, 12, 3);
telegram->read_bitvalue(wWReadiness_, 12, 4);
telegram->read_bitvalue(wWRecharging_, 13, 4);
telegram->read_bitvalue(wWTemperatureOK_, 13, 5);
telegram->read_bitvalue(wWCircPump_, 13, 2);
telegram->read_value(wWActivated_, 20);
telegram->read_value(wWSelTemp_, 10);
telegram->read_value(wWDisinfectTemp_, 9);
}
// 0x2A - MC10Status
// e.g. 88 00 2A 00 00 00 00 00 00 00 00 00 D2 00 00 80 00 00 01 08 80 00 02 47 00
// see https://github.com/proddy/EMS-ESP/issues/397
void Boiler::process_MC10Status(std::shared_ptr<const Telegram> telegram) {
telegram->read_value(wwMixTemperature_, 14);
telegram->read_value(wwBufferBoilerTemperature_, 18);
}
/*
* UBAOutdoorTemp - type 0xD1 - external temperature EMS+
*/
void Boiler::process_UBAOutdoorTemp(std::shared_ptr<const Telegram> telegram) {
telegram->read_value(extTemp_, 0);
}
// UBASetPoint 0x1A
void Boiler::process_UBASetPoints(std::shared_ptr<const Telegram> telegram) {
telegram->read_value(setFlowTemp_, 0); // boiler set temp from thermostat
telegram->read_value(setBurnPow_, 1); // max output power in %
telegram->read_value(setWWPumpPow_, 2); // ww pump speed/power?
}
#pragma GCC diagnostic push
#pragma GCC diagnostic ignored "-Wunused-parameter"
// 0x35
// not yet implemented
void Boiler::process_UBAFlags(std::shared_ptr<const Telegram> telegram) {
}
// 0x1C
// not yet implemented
void Boiler::process_UBAMaintenanceStatus(std::shared_ptr<const Telegram> telegram) {
// first byte: Maintenance due (0 = no, 3 = yes, due to operating hours, 8 = yes, due to date)
}
// 0x10, 0x11, 0x12
// not yet implemented
void Boiler::process_UBAErrorMessage(std::shared_ptr<const Telegram> telegram) {
// data: displaycode(2), errornumber(2), year, month, hour, day, minute, duration(2), src-addr
}
#pragma GCC diagnostic pop
// 0x15
void Boiler::process_UBAMaintenanceData(std::shared_ptr<const Telegram> telegram) {
// first byte: Maintenance messages (0 = none, 1 = by operating hours, 2 = by date)
// I see a value of 3 in the 1st byte when the boiler is booted, so probably a flag
if (telegram->message_data[0] == 3) {
LOG_WARNING(F("Boiler has booted."));
}
}
/*
* Commands
*/
// Set the warm water temperature 0x33
void Boiler::set_warmwater_temp(const char * value, const int8_t id) {
int v = 0;
if (!Helpers::value2number(value, v)) {
return;
}
LOG_INFO(F("Setting boiler warm water temperature to %d C"), v);
write_command(EMS_TYPE_UBAParameterWW, 2, v);
write_command(EMS_TYPE_UBAFlags, 3, v); // for i9000, see #397
}
// flow temp
void Boiler::set_flow_temp(const char * value, const int8_t id) {
int v = 0;
if (!Helpers::value2number(value, v)) {
return;
}
LOG_INFO(F("Setting boiler flow temperature to %d C"), v);
write_command(EMS_TYPE_UBASetPoints, 0, v);
}
// set min boiler output
void Boiler::set_min_power(const char * value, const int8_t id) {
int v = 0;
if (!Helpers::value2number(value, v)) {
return;
}
LOG_INFO(F("Setting boiler min power to "), v);
write_command(EMS_TYPE_UBAParameters, 3, v);
}
// set max temp
void Boiler::set_max_power(const char * value, const int8_t id) {
int v = 0;
if (!Helpers::value2number(value, v)) {
return;
}
LOG_INFO(F("Setting boiler max power to %d C"), v);
write_command(EMS_TYPE_UBAParameters, 2, v);
}
// set oiler on hysteresis
void Boiler::set_hyst_on(const char * value, const int8_t id) {
int v = 0;
if (!Helpers::value2number(value, v)) {
return;
}
LOG_INFO(F("Setting boiler hysteresis on to %d C"), v);
write_command(EMS_TYPE_UBAParameters, 5, v);
}
// set boiler off hysteresis
void Boiler::set_hyst_off(const char * value, const int8_t id) {
int v = 0;
if (!Helpers::value2number(value, v)) {
return;
}
LOG_INFO(F("Setting boiler hysteresis off to %d C"), v);
write_command(EMS_TYPE_UBAParameters, 4, v);
}
// set min burner period
void Boiler::set_burn_period(const char * value, const int8_t id) {
int v = 0;
if (!Helpers::value2number(value, v)) {
return;
}
LOG_INFO(F("Setting burner min. period to %d min"), v);
write_command(EMS_TYPE_UBAParameters, 6, v);
}
// set pump delay
void Boiler::set_pump_delay(const char * value, const int8_t id) {
int v = 0;
if (!Helpers::value2number(value, v)) {
return;
}
LOG_INFO(F("Setting boiler pump delay to %d min"), v);
write_command(EMS_TYPE_UBAParameters, 8, v);
}
// note some boilers do not have this setting, than it's done by thermostat
// on a RC35 it's by EMSESP::send_write_request(0x37, 0x10, 2, &set, 1, 0); (set is 1,2,3) 1=hot, 2=eco, 3=intelligent
void Boiler::set_warmwater_mode(const char * value, const int8_t id) {
if (value == nullptr) {
return;
}
uint8_t set;
if (strcmp(value, "hot") == 0) {
LOG_INFO(F("Setting boiler warm water to Hot"));
set = 0x00;
} else if (strcmp(value, "eco") == 0) {
LOG_INFO(F("Setting boiler warm water to Eco"));
set = 0xD8;
} else if (strcmp(value, "intelligent") == 0) {
LOG_INFO(F("Setting boiler warm water to Intelligent"));
set = 0xEC;
} else {
return; // do nothing
}
write_command(EMS_TYPE_UBAParameterWW, 9, set);
}
// turn on/off warm water
void Boiler::set_warmwater_activated(const char * value, const int8_t id) {
bool v = false;
if (!Helpers::value2bool(value, v)) {
return;
}
LOG_INFO(F("Setting boiler warm water %s"), v ? "on" : "off");
// https://github.com/proddy/EMS-ESP/issues/268
uint8_t n;
if (EMSbus::is_ht3()) {
n = (v ? 0x08 : 0x00); // 0x08 is on, 0x00 is off
} else {
n = (v ? 0xFF : 0x00); // 0xFF is on, 0x00 is off
}
write_command(EMS_TYPE_UBAParameterWW, 1, n);
}
// Activate / De-activate the Warm Tap Water
// Note: Using the type 0x1D to put the boiler into Test mode. This may be shown on the boiler with a flashing 'T'
void Boiler::set_tapwarmwater_activated(const char * value, const int8_t id) {
bool v = false;
if (!Helpers::value2bool(value, v)) {
return;
}
LOG_INFO(F("Setting tap warm tap water %s"), v ? "on" : "off");
uint8_t message_data[EMS_MAX_TELEGRAM_MESSAGE_LENGTH];
for (uint8_t i = 0; i < sizeof(message_data); i++) {
message_data[i] = 0x00;
}
// we use the special test mode 0x1D for this. Setting the first data to 5A puts the system into test mode and
// a setting of 0x00 puts it back into normal operating mode
// when in test mode we're able to mess around with the 3-way valve settings
if (!v) {
// on
message_data[0] = 0x5A; // test mode on
message_data[1] = 0x00; // burner output 0%
message_data[3] = 0x64; // boiler pump capacity 100%
message_data[4] = 0xFF; // 3-way valve hot water only
} else {
// get out of test mode. Send all zeros.
// telegram: 0B 08 1D 00 00
message_data[4] = 0x00; // test mode off
}
write_command(EMS_TYPE_UBAFunctionTest, 0, message_data, sizeof(message_data), 0);
}
// Activate / De-activate One Time warm water 0x35
// true = on, false = off
// See also https://github.com/proddy/EMS-ESP/issues/341#issuecomment-596245458 for Junkers
void Boiler::set_warmwater_onetime(const char * value, const int8_t id) {
bool v = false;
if (!Helpers::value2bool(value, v)) {
return;
}
LOG_INFO(F("Setting boiler warm water OneTime loading %s"), v ? "on" : "off");
write_command(EMS_TYPE_UBAFlags, 0, (v ? 0x22 : 0x02));
}
// Activate / De-activate circulation of warm water 0x35
// true = on, false = off
void Boiler::set_warmwater_circulation(const char * value, const int8_t id) {
bool v = false;
if (!Helpers::value2bool(value, v)) {
return;
}
LOG_INFO(F("Setting boiler warm water circulation %s"), v ? "on" : "off");
write_command(EMS_TYPE_UBAFlags, 1, (v ? 0x22 : 0x02));
}
// add console commands
void Boiler::console_commands(Shell & shell, unsigned int context) {
EMSESPShell::commands->add_command(ShellContext::BOILER,
CommandFlags::ADMIN,
flash_string_vector{F_(read)},
flash_string_vector{F_(typeid_mandatory)},
[=](Shell & shell __attribute__((unused)), const std::vector<std::string> & arguments) {
uint16_t type_id = Helpers::hextoint(arguments.front().c_str());
EMSESP::set_read_id(type_id);
EMSESP::send_read_request(type_id, get_device_id());
});
EMSESPShell::commands->add_command(ShellContext::BOILER,
CommandFlags::USER,
flash_string_vector{F_(show)},
[&](Shell & shell, const std::vector<std::string> & arguments __attribute__((unused))) { show_values(shell); });
// enter the context
Console::enter_custom_context(shell, context);
}