Files
EMS-ESP32/doc/home_assistant/sensors.yaml
2019-03-10 15:09:51 +01:00

150 lines
4.1 KiB
YAML

- platform: mqtt
state_topic: 'home/ems-esp/thermostat_data'
name: 'Current Room Temperature'
unit_of_measurement: '°C'
value_template: "{{ value_json.thermostat_currtemp }}"
- platform: mqtt
state_topic: 'home/ems-esp/thermostat_data'
name: 'Current Set Temperature'
unit_of_measurement: '°C'
value_template: "{{ value_json.thermostat_seltemp }}"
- platform: mqtt
state_topic: 'home/ems-esp/thermostat_data'
name: 'Current Mode'
value_template: "{{ value_json.thermostat_mode }}"
# last time esp-esp was started
- platform: template
sensors:
boiler_boottime:
value_template: '{{ as_timestamp(states.automation.see_if_boiler_restarts.attributes.last_triggered) | timestamp_custom("%H:%M:%S %d/%m/%y") }}'
- platform: mqtt
state_topic: 'home/ems-esp/showertime'
name: 'Last shower duration'
force_update: true
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Tap Water'
value_template: '{{ value_json.tapwaterActive }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Heating'
value_template: '{{ value_json.heatingActive }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Warm Water selected temperature'
unit_of_measurement: '°C'
value_template: '{{ value_json.wWSelTemp }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Warm Water tapwater flow rate'
unit_of_measurement: 'l/min'
value_template: '{{ value_json.wWCurFlow }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Warm Water current temperature'
unit_of_measurement: '°C'
value_template: '{{ value_json.wWCurTmp }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Warm Water activated'
value_template: '{{ value_json.wWActivated }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Warm Water 3-way valve'
value_template: '{{ value_json.wWHeat }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Current flow temperature'
unit_of_measurement: '°C'
value_template: '{{ value_json.curFlowTemp }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Return temperature'
unit_of_measurement: '°C'
value_template: '{{ value_json.retTemp }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Gas'
value_template: '{{ value_json.burnGas }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Boiler pump'
value_template: '{{ value_json.heatPmp }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Fan'
value_template: '{{ value_json.fanWork }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Ignition'
value_template: '{{ value_json.ignWork }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Circulation pump'
value_template: '{{ value_json.wWCirc }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Burner max power'
unit_of_measurement: '%'
value_template: '{{ value_json.selBurnPow }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Burner max power'
unit_of_measurement: '%'
value_template: '{{ value_json.selBurnPow }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Burner current power'
unit_of_measurement: '%'
value_template: '{{ value_json.curBurnPow }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'System Pressure'
unit_of_measurement: 'bar'
value_template: '{{ value_json.sysPress }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Boiler temperature'
unit_of_measurement: '°C'
value_template: '{{ value_json.boilTemp }}'
- platform: mqtt
state_topic: 'home/ems-esp/boiler_data'
name: 'Pump modulation'
unit_of_measurement: '%'
value_template: '{{ value_json.pumpMod }}'
- platform: template
sensors:
showertime_time:
value_template: '{{ as_timestamp(states.sensor.last_shower_duration.last_updated) | int | timestamp_custom("%-I:%M %P on %a %-d %b") }}'
boiler_updated:
value_template: '{{ as_timestamp(states.sensor.boiler_temperature.last_updated) | timestamp_custom("%H:%M on %d/%b") }}'