See https://github.com/proddy/EMS-ESP/issues/632

Added

  • Power settings for ESP32
  • Rx and Tx counts to Heartbeat MQTT payload
  • Ethernet support (ESP32)
  • id to info command to show only a heatingcircuit
  • add sending devices that are not listed to 0x07
  • extra MQTT boolean option for "ON" and "OFF"
  • Support for chunked MQTT payloads to allow large data sets > 2kb
  • External Button support (#708) for resetting to factory defaults and other actions

Fixed

  • telegrams matched to masterthermostat 0x18
  • multiple roomcontrollers
  • readback after write with delay (give ems-devices time to set the value)
  • Thermostat ES72/RC20 device 66 to command-set RC20_2
  • MQTT payloads not adding to queue when MQTT is re-connecting (fixes #369)

Changed

  • split show values in smaller packages (edited)
  • extended length of IP/hostname from 32 to 48 chars (#676)
  • check flowsensor for tap_water_active
  • mqtt prefixed with Base
  • count Dallas sensor fails
  • switch from SPIFFS to LITTLEFS
  • Added ID to MQTT payloads which is the Device's product ID and used in HA to identify a unique HA device
  • Increased MQTT buffer and reduced wait time between publishes
  • Updated to the latest ArduinoJson library
  • some names of mqtt-tags like in v2.2.1
  • Breaking Change new ESP32 partition side to allow for smoother OTA and fallback

Removed