mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-06 07:49:52 +03:00
147 lines
3.9 KiB
YAML
147 lines
3.9 KiB
YAML
|
|
# thermostat HC1
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/thermostat_data'
|
|
name: 'Current Room Temperature'
|
|
unit_of_measurement: '°C'
|
|
value_template: "{{ value_json.hc1.currtemp }}"
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/thermostat_data'
|
|
name: 'Current Set Temperature'
|
|
unit_of_measurement: '°C'
|
|
value_template: "{{ value_json.hc1.seltemp }}"
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/thermostat_data'
|
|
name: 'Current Mode'
|
|
value_template: "{{ value_json.hc1.mode }}"
|
|
|
|
# boiler
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Warm Water selected temperature'
|
|
unit_of_measurement: '°C'
|
|
value_template: '{{ value_json.wWSelTemp }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Warm Water tapwater flow rate'
|
|
unit_of_measurement: 'l/min'
|
|
value_template: '{{ value_json.wWCurFlow }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Warm Water current temperature'
|
|
unit_of_measurement: '°C'
|
|
value_template: '{{ value_json.wWCurTmp }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Warm Water activated'
|
|
value_template: '{{ value_json.wWActivated }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Warm Water 3-way valve'
|
|
value_template: '{{ value_json.wWHeat }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Current flow temperature'
|
|
unit_of_measurement: '°C'
|
|
value_template: '{{ value_json.curFlowTemp }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Return temperature'
|
|
unit_of_measurement: '°C'
|
|
value_template: '{{ value_json.retTemp }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Gas'
|
|
value_template: '{{ value_json.burnGas }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Boiler pump'
|
|
value_template: '{{ value_json.heatPmp }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Fan'
|
|
value_template: '{{ value_json.fanWork }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Ignition'
|
|
value_template: '{{ value_json.ignWork }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Circulation pump'
|
|
value_template: '{{ value_json.wWCirc }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Burner max power'
|
|
unit_of_measurement: '%'
|
|
value_template: '{{ value_json.selBurnPow }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Burner max power'
|
|
unit_of_measurement: '%'
|
|
value_template: '{{ value_json.selBurnPow }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Burner current power'
|
|
unit_of_measurement: '%'
|
|
value_template: '{{ value_json.curBurnPow }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'System Pressure'
|
|
unit_of_measurement: 'bar'
|
|
value_template: '{{ value_json.sysPress }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Boiler temperature'
|
|
unit_of_measurement: '°C'
|
|
value_template: '{{ value_json.boilTemp }}'
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/boiler_data'
|
|
name: 'Pump modulation'
|
|
unit_of_measurement: '%'
|
|
value_template: '{{ value_json.pumpMod }}'
|
|
|
|
# shower time duration
|
|
|
|
- platform: mqtt
|
|
name: 'Last shower duration'
|
|
state_topic: "home/ems-esp/shower_data"
|
|
value_template: "{{ value_json.duration | is_defined }}"
|
|
|
|
- platform: template
|
|
sensors:
|
|
showertime_time:
|
|
value_template: '{{ as_timestamp(states.sensor.last_shower_duration.last_updated) | int | timestamp_custom("%-I:%M on %a %-d %b") }}'
|
|
|
|
boiler_updated:
|
|
value_template: '{{ as_timestamp(states.sensor.boiler_temperature.last_updated) | timestamp_custom("%H:%M on %d/%b") }}'
|
|
|
|
boiler_boottime:
|
|
value_template: '{{ as_timestamp(states.automation.see_if_boiler_restarts.attributes.last_triggered) | timestamp_custom("%H:%M:%S %d/%m/%y") }}'
|
|
|
|
# general
|
|
|
|
- platform: mqtt
|
|
state_topic: 'home/ems-esp/status'
|
|
name: 'ems-esp status'
|