Files
EMS-ESP32/src/devices/boiler.h
2022-05-23 21:08:00 +02:00

299 lines
15 KiB
C++

/*
* EMS-ESP - https://github.com/emsesp/EMS-ESP
* Copyright 2020 Paul Derbyshire
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <http://www.gnu.org/licenses/>.
*/
#ifndef EMSESP_BOILER_H
#define EMSESP_BOILER_H
#include "emsesp.h"
namespace emsesp {
class Boiler : public EMSdevice {
public:
Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const char * version, const std::string & name, uint8_t flags, uint8_t brand);
private:
static uuid::log::Logger logger_;
// specific boiler characteristics, stripping the top 4 bits
inline uint8_t model() const {
return (flags() & 0x0F);
}
void check_active(const bool force = false);
uint8_t boilerState_ = EMS_VALUE_UINT_NOTSET; // Boiler state flag - FOR INTERNAL USE
static constexpr uint8_t EMS_TYPE_UBASettingsWW = 0x26;
static constexpr uint8_t EMS_TYPE_UBAParameterWW = 0x33;
static constexpr uint8_t EMS_TYPE_UBAFunctionTest = 0x1D;
static constexpr uint8_t EMS_TYPE_UBAFlags = 0x35;
static constexpr uint8_t EMS_TYPE_UBASetPoints = 0x1A;
static constexpr uint8_t EMS_TYPE_UBAParameters = 0x16;
static constexpr uint8_t EMS_TYPE_UBAParametersPlus = 0xE6;
static constexpr uint8_t EMS_TYPE_UBAParameterWWPlus = 0xEA;
static constexpr uint16_t EMS_TYPE_UBAInformation = 0x495;
static constexpr uint16_t EMS_TYPE_UBAEnergySupplied = 0x494;
// ww
uint8_t wwSetTemp_; // DHW set temperature
uint8_t wwSelTemp_; // DHW selected temperature
uint8_t wwSelTempLow_; // DHW lower selected temperature
uint8_t wwSelTempOff_; // DHW selected temperature for off position
uint8_t wwSelTempSingle_; // DHW single charge temperature
uint8_t wwType_; // 0-off, 1-flow, 2-flowbuffer, 3-buffer, 4-layered buffer
uint8_t wwComfort_; // WW comfort mode
uint8_t wwComfort1_; // WW comfort mode RC310
uint8_t wwCircPump_; // DHW circulation pump available
uint8_t wwChargeType_; // DHW charge type (pump or 3-way-valve)
uint8_t wwChargeOptimization_; // DHW charge optimization
uint8_t wwDisinfectionTemp_; // DHW disinfection temperature to prevent infection
uint8_t wwCircMode_; // DHW circulation pump mode
uint8_t wwCirc_; // Circulation on/off
uint16_t wwCurTemp_; // DHW current temperature
uint16_t wwCurTemp2_; // DHW current temperature storage
uint8_t wwCurFlow_; // DHW current flow temp in l/min
uint16_t wwStorageTemp1_; // DHW storage temp 1
uint16_t wwStorageTemp2_; // DHW storage temp 2
uint8_t wwActivated_; // DHW activated
uint8_t wwOneTime_; // DHW one time function on/off
uint8_t wwDisinfect_; // DHW disinfection on/off
uint8_t wwCharging_; // DHW charging on/off
uint8_t wwRecharging_; // DHW recharge on/off
uint8_t wwTempOK_; // DHW temperature ok on/off
uint8_t wwActive_; //
uint8_t ww3wayValve_; // 3-way valve on WW
uint8_t wwSetPumpPower_; // ww pump speed/power?
uint8_t wwFlowTempOffset_; // Boiler offset for ww heating
uint8_t wwMaxPower_; // DHW maximum power
uint8_t wwMaxTemp_; // DHW maximum temperature
uint32_t wwStarts_; // DHW starts
uint32_t wwStarts2_; // DHW control starts
uint32_t wwWorkM_; // DHW minutes
int8_t wwHystOn_;
int8_t wwHystOff_;
uint8_t wwTapActivated_; // maintenance-mode to switch DHW off
uint16_t wwMixerTemp_; // mixing temperature
uint16_t wwCylMiddleTemp_; // Cyl middle temperature (TS3)
// main
uint8_t reset_; // for reset command
uint8_t heatingActive_; // Central heating is on/off
uint8_t tapwaterActive_; // Hot tap water is on/off
uint8_t selFlowTemp_; // Selected flow temperature
uint8_t selBurnPow_; // Burner max power % (can be > 100%)
uint8_t heatingPump2Mod_; // heatpump modulation from 0xE3 (heatpumps)
uint8_t heatingPumpMod_; // Pump modulation %
int16_t outdoorTemp_; // Outside temperature
uint16_t curFlowTemp_; // Current flow temperature
uint16_t retTemp_; // Return temperature
uint16_t switchTemp_; // Switch temperature
uint8_t sysPress_; // System pressure
uint16_t boilTemp_; // Boiler temperature
uint16_t exhaustTemp_; // Exhaust temperature
uint8_t burnGas_; // Gas on/off
uint8_t burnGas2_; // Gas stage 2 on/off
uint16_t flameCurr_; // Flame current in micro amps
uint8_t heatingPump_; // Boiler heating pump on/off
uint8_t fanWork_; // Fan on/off
uint8_t ignWork_; // Ignition on/off
uint8_t oilPreHeat_; // oil preheating on
uint8_t heatingActivated_; // Heating activated on the boiler
uint8_t heatingTemp_; // Heating temperature setting on the boiler
uint8_t pumpModMax_; // Boiler circuit pump modulation max. power %
uint8_t pumpModMin_; // Boiler circuit pump modulation min. power
uint8_t pumpDelay_;
uint8_t burnMinPeriod_;
uint8_t burnMinPower_;
uint8_t burnMaxPower_;
int8_t boilHystOn_;
int8_t boilHystOff_;
uint8_t setFlowTemp_; // boiler setpoint temp
uint8_t curBurnPow_; // Burner current power %
uint8_t setBurnPow_; // max output power in %
uint32_t burnStarts_; // burner restarts
uint32_t burnWorkMin_; // Total burner operating time
uint32_t burn2WorkMin_; // burner stage 2 operating time
uint32_t heatWorkMin_; // Total heat operating time
uint32_t UBAuptime_; // Total UBA working hours
char lastCode_[50]; // last error code
char serviceCode_[4]; // 3 character status/service code
uint16_t serviceCodeNumber_; // error/service code
uint8_t emergencyOps_;
uint8_t emergencyTemp_;
// info
uint32_t upTimeControl_; // Operating time control
uint32_t upTimeCompHeating_; // Operating time compressor heating
uint32_t upTimeCompCooling_; // Operating time compressor cooling
uint32_t upTimeCompWw_; // Operating time compressor DHW
uint32_t upTimeCompPool_; // Operating time compressor pool
uint32_t totalCompStarts_; // Total Commpressor control starts
uint32_t heatingStarts_; // Heating control starts
uint32_t coolingStarts_; // Cooling control starts
uint32_t poolStarts_; // DHW control starts
uint32_t nrgConsTotal_; // Energy consumption total
uint32_t nrgConsCompTotal_; // Energy consumption compressor total
uint32_t nrgConsCompHeating_; // Energy consumption compressor heating
uint32_t nrgConsCompWw_; // Energy consumption compressor DHW
uint32_t nrgConsCompCooling_; // Energy consumption compressor cooling
uint32_t nrgConsCompPool_; // Energy consumption compressor pool
uint32_t nrgSuppTotal_; // Energy supplied total
uint32_t nrgSuppHeating_; // Energy supplied heating
uint32_t nrgSuppWw_; // Energy supplied DHW
uint32_t nrgSuppCooling_; // Energy supplied cooling
uint32_t nrgSuppPool_; // Energy supplied pool
uint32_t auxElecHeatNrgConsTotal_; // Auxiliary electrical heater energy consumption total
uint32_t auxElecHeatNrgConsHeating_; // Auxiliary electrical heater energy consumption heating
uint32_t auxElecHeatNrgConsWW_; // Auxiliary electrical heater energy consumption DHW
uint32_t auxElecHeatNrgConsPool_; // Auxiliary electrical heater energy consumption Pool
char maintenanceMessage_[4];
char maintenanceDate_[12];
uint8_t maintenanceType_;
uint16_t maintenanceTime_;
// heatpump
uint8_t hpPower_;
uint8_t hpCompOn_;
uint8_t hpBrinePumpSpd_;
uint8_t hpCompSpd_;
uint8_t hpCircSpd_;
uint16_t hpBrineIn_;
uint16_t hpBrineOut_;
uint16_t hpSuctionGas_;
uint16_t hpHotGas_;
uint8_t hpSwitchValve_;
uint8_t hpActivity_;
uint8_t hpHeatingOn_;
uint8_t hpCoolingOn_;
uint8_t hpWwOn_;
uint8_t hpPoolOn_;
int16_t hpTc0_;
int16_t hpTc1_;
int16_t hpTc3_;
int16_t hpTr3_;
int16_t hpTr4_;
int16_t hpTr5_;
int16_t hpTr6_;
int16_t hpTr7_;
int16_t hpTl2_;
int16_t hpPl1_;
int16_t hpPh1_;
// Pool unit
int8_t poolSetTemp_;
/*
* Hybrid heatpump with telegram 0xBB is readable and writeable in boiler and thermostat
* thermostat always overwrites settings in boiler
* enable settings here if no thermostat is used in system
*
// HybridHP
uint8_t hybridStrategy_; // cost = 2, temperature = 3, mix = 4
int8_t switchOverTemp_; // degrees
uint8_t energyCostRatio_; // is *10
uint8_t fossileFactor_; // is * 10
uint8_t electricFactor_; // is * 10
uint8_t delayBoiler_; // minutes
uint8_t tempDiffBoiler_; // relative temperature degrees
*/
void process_UBAParameterWW(std::shared_ptr<const Telegram> telegram);
void process_UBAMonitorFast(std::shared_ptr<const Telegram> telegram);
void process_UBATotalUptime(std::shared_ptr<const Telegram> telegram);
void process_UBAParameters(std::shared_ptr<const Telegram> telegram);
void process_UBAMonitorWW(std::shared_ptr<const Telegram> telegram);
void process_UBAMonitorFastPlus(std::shared_ptr<const Telegram> telegram);
void process_UBAMonitorSlow(std::shared_ptr<const Telegram> telegram);
void process_UBAMonitorSlowPlus(std::shared_ptr<const Telegram> telegram);
void process_UBAMonitorSlowPlus2(std::shared_ptr<const Telegram> telegram);
void process_UBAParametersPlus(std::shared_ptr<const Telegram> telegram);
void process_UBAParameterWWPlus(std::shared_ptr<const Telegram> telegram);
void process_UBAOutdoorTemp(std::shared_ptr<const Telegram> telegram);
void process_UBASetPoints(std::shared_ptr<const Telegram> telegram);
void process_UBAFlags(std::shared_ptr<const Telegram> telegram);
void process_MC110Status(std::shared_ptr<const Telegram> telegram);
void process_UBAMaintenanceStatus(std::shared_ptr<const Telegram> telegram);
void process_UBAMaintenanceData(std::shared_ptr<const Telegram> telegram);
void process_ErrorMessage(std::shared_ptr<const Telegram> telegram);
void process_UBAErrorMessage(std::shared_ptr<const Telegram> telegram);
void process_UBAErrorMessage2(std::shared_ptr<const Telegram> telegram);
void process_UBAMonitorWWPlus(std::shared_ptr<const Telegram> telegram);
void process_UBAInformation(std::shared_ptr<const Telegram> telegram);
void process_UBAEnergySupplied(std::shared_ptr<const Telegram> telegram);
void process_CascadeMessage(std::shared_ptr<const Telegram> telegram);
void process_UBASettingsWW(std::shared_ptr<const Telegram> telegram);
void process_HpPower(std::shared_ptr<const Telegram> telegram);
void process_HpOutdoor(std::shared_ptr<const Telegram> telegram);
void process_HpPool(std::shared_ptr<const Telegram> telegram);
void process_HybridHp(std::shared_ptr<const Telegram> telegram);
// commands - none of these use the additional id parameter
bool set_ww_mode(const char * value, const int8_t id);
bool set_ww_mode1(const char * value, const int8_t id);
bool set_ww_activated(const char * value, const int8_t id);
bool set_tapwarmwater_activated(const char * value, const int8_t id);
bool set_ww_onetime(const char * value, const int8_t id);
bool set_ww_disinfect(const char * value, const int8_t id);
bool set_ww_circulation(const char * value, const int8_t id);
bool set_ww_circulation_pump(const char * value, const int8_t id);
bool set_ww_circulation_mode(const char * value, const int8_t id);
bool set_ww_temp(const char * value, const int8_t id);
bool set_ww_temp_low(const char * value, const int8_t id);
bool set_ww_temp_single(const char * value, const int8_t id);
bool set_ww_disinfect_temp(const char * value, const int8_t id);
bool set_ww_maxpower(const char * value, const int8_t id);
bool set_ww_maxtemp(const char * value, const int8_t id);
bool set_ww_flowTempOffset(const char * value, const int8_t id);
bool set_ww_chargeOptimization(const char * value, const int8_t id);
bool set_flow_temp(const char * value, const int8_t id);
bool set_burn_power(const char * value, const int8_t id);
bool set_heating_activated(const char * value, const int8_t id);
bool set_heating_temp(const char * value, const int8_t id);
bool set_min_power(const char * value, const int8_t id);
bool set_max_power(const char * value, const int8_t id);
bool set_min_pump(const char * value, const int8_t id);
bool set_max_pump(const char * value, const int8_t id);
bool set_hyst_on(const char * value, const int8_t id);
bool set_hyst_off(const char * value, const int8_t id);
bool set_burn_period(const char * value, const int8_t id);
bool set_pump_delay(const char * value, const int8_t id);
bool set_reset(const char * value, const int8_t id);
bool set_maintenance(const char * value, const int8_t id);
bool set_maintenancetime(const char * value, const int8_t id);
bool set_maintenancedate(const char * value, const int8_t id);
bool set_ww_hyst_on(const char * value, const int8_t id);
bool set_ww_hyst_off(const char * value, const int8_t id);
bool set_pool_temp(const char * value, const int8_t id);
bool set_emergency_temp(const char * value, const int8_t id);
bool set_emergency_ops(const char * value, const int8_t id);
/*
bool set_hybridStrategy(const char * value, const int8_t id);
bool set_switchOverTemp(const char * value, const int8_t id);
bool set_energyCostRatio(const char * value, const int8_t id);
bool set_fossileFactor(const char * value, const int8_t id);
bool set_electricFactor(const char * value, const int8_t id);
bool set_delayBoiler(const char * value, const int8_t id);
bool set_tempDiffBoiler(const char * value, const int8_t id);
*/
};
} // namespace emsesp