"Boiler Nefit Trendline HRC30 (DeviceID:0x08, ProductID:123, Version:06.01)": {
|
|
"force heating off": "off",
|
|
"heating active": "off",
|
|
"tapwater active": "off",
|
|
"selected flow temperature": 5,
|
|
"heating pump modulation": 0,
|
|
"current flow temperature": 41.4,
|
|
"return temperature": 37.7,
|
|
"system pressure": 1.3,
|
|
"actual boiler temperature": 44.2,
|
|
"gas": "off",
|
|
"gas stage 2": "off",
|
|
"flame current": 0,
|
|
"fan": "off",
|
|
"ignition": "off",
|
|
"oil preheating": "off",
|
|
"burner min power": 0,
|
|
"burner max power": 50,
|
|
"burner min period": 10,
|
|
"hysteresis on temperature": -6,
|
|
"hysteresis off temperature": 6,
|
|
"heating activated": "on",
|
|
"heating temperature": 70,
|
|
"heating pump": "off",
|
|
"boiler pump max power": 70,
|
|
"boiler pump min power": 50,
|
|
"boiler pump mode": "proportional",
|
|
"pump delay": 2,
|
|
"burner selected max power": 0,
|
|
"burner current power": 0,
|
|
"burner starts": 394602,
|
|
"total burner operating time": "480 days 4 hours 23 minutes",
|
|
"burner stage 2 operating time": "0 days 0 hours 0 minutes",
|
|
"total heat operating time": "395 days 2 hours 14 minutes",
|
|
"burner starts heating": 46245,
|
|
"total UBA operating time": "3932 days 23 hours 58 minutes",
|
|
"last error code": "2E(207) 100.75.2000 65:00 (0 min)",
|
|
"service code": "0H",
|
|
"service code number": 203,
|
|
"maintenance message": "H00",
|
|
"maintenance scheduled": "manual",
|
|
"time to next maintenance": 6000,
|
|
"next maintenance date": "01.01.2012",
|
|
"dhw turn on/off": "on",
|
|
"dhw set temperature": 62,
|
|
"dhw selected temperature": 60,
|
|
"dhw type": "flow",
|
|
"dhw comfort": "hot",
|
|
"dhw flow temperature offset": 40,
|
|
"dhw max power": 100,
|
|
"dhw circulation pump available": "off",
|
|
"dhw charging type": "3-way valve",
|
|
"dhw hysteresis on temperature": -5,
|
|
"dhw hysteresis off temperature": 0,
|
|
"dhw disinfection temperature": 70,
|
|
"dhw circulation pump mode": "off",
|
|
"dhw circulation active": "off",
|
|
"dhw current intern temperature": 33.5,
|
|
"dhw current tap water flow": 0,
|
|
"dhw storage intern temperature": 33.5,
|
|
"dhw activated": "on",
|
|
"dhw one time charging": "off",
|
|
"dhw disinfecting": "off",
|
|
"dhw charging": "off",
|
|
"dhw recharging": "off",
|
|
"dhw temperature ok": "on",
|
|
"dhw active": "off",
|
|
"dhw 3-way valve active": "on",
|
|
"dhw set pump power": 0,
|
|
"dhw starts": 348357,
|
|
"dhw active time": "85 days 2 hours 9 minutes",
|
|
"nominal Power": 30,
|
|
"total energy": 3088.69,
|
|
"energy heating": 2532.94,
|
|
"dhw energy": 555.75
|
|
},
|
|
"Thermostat RC20 (DeviceID:0x17, ProductID:77, Version:03.03)": {
|
|
"date/time": "10.12.2023 13:49",
|
|
"hc1 how hot lounge should be": 19,
|
|
"hc1 current room temp": 19.5,
|
|
"hc1 mqtt discovery current room temperature": "roomTemp",
|
|
"hc1 mode": "auto",
|
|
"hc1 manual temperature": 21.5,
|
|
"hc1 temperature when mode is off": 7,
|
|
"hc1 day temperature T2": 20,
|
|
"hc1 day temperature T3": 20,
|
|
"hc1 day temperature T4": 20,
|
|
"hc1 night temperature T1": 15,
|
|
"hc1 program switchtime": "00 mo 00:00 T1"
|
|
},
|
|
"Controller Module BC10 (DeviceID:0x09, ProductID:190, Version:01.03)": {},
|
|
"Custom Entities": {
|
|
"boiler_flowtemp": 5,
|
|
"nominalpower": 30,
|
|
"minmodulation": 23,
|
|
"maxmodulation": 115
|
|
},
|
|
"Analog Sensors": {},
|
|
"Temperature Sensors": {
|
|
"zolder": 18.3
|
|
}
|
|
} |