"Boiler Nefit Trendline HRC30 (DeviceID:0x08, ProductID:123, Version:06.01)": {
"force heating off": "off",
"heating active": "off",
"tapwater active": "off",
"selected flow temperature": 5,
"heating pump modulation": 0,
"current flow temperature": 41.4,
"return temperature": 37.7,
"system pressure": 1.3,
"actual boiler temperature": 44.2,
"gas": "off",
"gas stage 2": "off",
"flame current": 0,
"fan": "off",
"ignition": "off",
"oil preheating": "off",
"burner min power": 0,
"burner max power": 50,
"burner min period": 10,
"hysteresis on temperature": -6,
"hysteresis off temperature": 6,
"heating activated": "on",
"heating temperature": 70,
"heating pump": "off",
"boiler pump max power": 70,
"boiler pump min power": 50,
"boiler pump mode": "proportional",
"pump delay": 2,
"burner selected max power": 0,
"burner current power": 0,
"burner starts": 394602,
"total burner operating time": "480 days 4 hours 23 minutes",
"burner stage 2 operating time": "0 days 0 hours 0 minutes",
"total heat operating time": "395 days 2 hours 14 minutes",
"burner starts heating": 46245,
"total UBA operating time": "3932 days 23 hours 58 minutes",
"last error code": "2E(207) 100.75.2000 65:00 (0 min)",
"service code": "0H",
"service code number": 203,
"maintenance message": "H00",
"maintenance scheduled": "manual",
"time to next maintenance": 6000,
"next maintenance date": "01.01.2012",
"dhw turn on/off": "on",
"dhw set temperature": 62,
"dhw selected temperature": 60,
"dhw type": "flow",
"dhw comfort": "hot",
"dhw flow temperature offset": 40,
"dhw max power": 100,
"dhw circulation pump available": "off",
"dhw charging type": "3-way valve",
"dhw hysteresis on temperature": -5,
"dhw hysteresis off temperature": 0,
"dhw disinfection temperature": 70,
"dhw circulation pump mode": "off",
"dhw circulation active": "off",
"dhw current intern temperature": 33.5,
"dhw current tap water flow": 0,
"dhw storage intern temperature": 33.5,
"dhw activated": "on",
"dhw one time charging": "off",
"dhw disinfecting": "off",
"dhw charging": "off",
"dhw recharging": "off",
"dhw temperature ok": "on",
"dhw active": "off",
"dhw 3-way valve active": "on",
"dhw set pump power": 0,
"dhw starts": 348357,
"dhw active time": "85 days 2 hours 9 minutes",
"nominal Power": 30,
"total energy": 3088.69,
"energy heating": 2532.94,
"dhw energy": 555.75
},
"Thermostat RC20 (DeviceID:0x17, ProductID:77, Version:03.03)": {
"date/time": "10.12.2023 13:49",
"hc1 how hot lounge should be": 19,
"hc1 current room temp": 19.5,
"hc1 mqtt discovery current room temperature": "roomTemp",
"hc1 mode": "auto",
"hc1 manual temperature": 21.5,
"hc1 temperature when mode is off": 7,
"hc1 day temperature T2": 20,
"hc1 day temperature T3": 20,
"hc1 day temperature T4": 20,
"hc1 night temperature T1": 15,
"hc1 program switchtime": "00 mo 00:00 T1"
},
"Controller Module BC10 (DeviceID:0x09, ProductID:190, Version:01.03)": {},
"Custom Entities": {
"boiler_flowtemp": 5,
"nominalpower": 30,
"minmodulation": 23,
"maxmodulation": 115
},
"Analog Sensors": {},
"Temperature Sensors": {
"zolder": 18.3
}
}