Files
EMS-ESP32/CHANGELOG_LATEST.md
2024-09-29 12:01:40 +02:00

80 lines
5.7 KiB
Markdown

# Changelog
## [3.7.0]
## **IMPORTANT! BREAKING CHANGES with 3.6.5**
- "ww" and "wwc" has been renamed to "dhw". It is nested JSON object in both the MQTT and API outputs. The old prefix has also been removed from MQTT topics ([#1634](https://github.com/emsesp/EMS-ESP32/issues/1634)). This will impact historical data in home automation systems like Home Assistant and IOBroker. To preserve the current value of dhw energy (was previously nrgww) refer to this issue [#1938](https://github.com/emsesp/EMS-ESP32/issues/1938).
- dhw entities from the MM100/SM100 have been moved under a new Device called 'water'.
- The automatically generated temperature sensor ID has replaced dashes (`-`) with underscores (`_`) to be compatible with Home Assistant.
- `api/system/info` has it's JSON key names changed to camelCase syntax.
For more details go to [www.emsesp.org](https://www.emsesp.org/).
## Added
- some more entities for dhw with SM100 module
- thermostat second dhw circuit [#1634](https://github.com/emsesp/EMS-ESP32/issues/1634)
- remote thermostat emulation for RC100H, RC200 and FB10 [#1287](https://github.com/emsesp/EMS-ESP32/discussions/1287), [#1602](https://github.com/emsesp/EMS-ESP32/discussions/1602), [#1551](https://github.com/emsesp/EMS-ESP32/discussions/1551)
- heatpump dhw stop temperatures [#1624](https://github.com/emsesp/EMS-ESP32/issues/1624)
- reset history [#1695](https://github.com/emsesp/EMS-ESP32/issues/1695)
- heatpump entities `fan` and `shutdown` [#1690](https://github.com/emsesp/EMS-ESP32/discussions/1690)
- mqtt HA-mode 3 for v3.6 compatible HA entities, set on update v3.6->v3.7
- HP input states [#1723](https://github.com/emsesp/EMS-ESP32/discussions/1723)
- holiday settings for rego 3000 [#1735](https://github.com/emsesp/EMS-ESP32/issues/1735)
- Added scripts for OTA (scripts/upload.py and upload_cli.py) [#1738](https://github.com/emsesp/EMS-ESP32/issues/1738)
- timeout for remote thermostat emulation [#1680](https://github.com/emsesp/EMS-ESP32/discussions/1680), [#1774](https://github.com/emsesp/EMS-ESP32/issues/1774)
- CR120 thermostat as own model() [#1779](https://github.com/emsesp/EMS-ESP32/discussions/1779)
- modules - external linkable module library [#1778](https://github.com/emsesp/EMS-ESP32/issues/1778)
- scheduler onChange and Conditions [#1806](https://github.com/emsesp/EMS-ESP32/issues/1806)
- make remote control timeout editable [#1774](https://github.com/emsesp/EMS-ESP32/issues/1774)
- added extra pump characteristics (mode and pressure for EMS+) by @SLTKA [#1802](https://github.com/emsesp/EMS-ESP32/pull/1802)
- allow device name to be customized [#1174](https://github.com/emsesp/EMS-ESP32/issues/1174)
- Modbus support by @mheyse [#1744](https://github.com/emsesp/EMS-ESP32/issues/1744)
- System Message command [#1854](https://github.com/emsesp/EMS-ESP32/issues/1854)
- scheduler can use web get/post for values and commands [#1806](https://github.com/emsesp/EMS-ESP32/issues/1806)
- RT800 remote emulation [#1867](https://github.com/emsesp/EMS-ESP32/issues/1867)
- RC310 cooling parameters [#1857](https://github.com/emsesp/EMS-ESP32/issues/1857)
- command `api/device/entities` [#1897](https://github.com/emsesp/EMS-ESP32/issues/1897)
- switchprogmode [#1903]<https://github.com/emsesp/EMS-ESP32/discussions/1903>
- autodetect and download firmware upgrades via the WebUI
- command 'show log' that lists out the current weblog buffer, showing last messages.
- default web log buffer to 25 lines for ESP32s with no PSRAM
- try and determine correct board profile if none is set during boot
- auto Scroll in WebLog UI - reduced delay so incoming logs are faster
- uploading custom support info for Guest users [#2054]<https://github.com/emsesp/EMS-ESP32/issues/2054>
## Fixed
- remote thermostat emulation for RC200 on Rego2000/3000 thermostats [#1691](https://github.com/emsesp/EMS-ESP32/discussions/1691)
- log shows data for F7/F9 requests
- Detection of LittleFS for factory setting wasn't working
- Check for bad GPIOs with Ethernet before the ethernet is initialized
- Show values with factor 50 on webUI [#2064](https://github.com/emsesp/EMS-ESP32/issues/2064)
- Rendering of values between -1 and 0
## Changed
- use flag for BC400 compatible thermostats, manage different mode settings
- use factory partition for 16M flash
- store digital out states to nvs
- Refresh UI - moving settings to one location [#1665](https://github.com/emsesp/EMS-ESP32/issues/1665)
- rename DeviceValueTypes, add UINT32 for custom entities
- dynamic register dhw circuits for thermostat
- removed OTA feature [#1738](https://github.com/emsesp/EMS-ESP32/issues/1738)
- added shower min duration [#1801](https://github.com/emsesp/EMS-ESP32/issues/1801)
- Include TXT file along with the generated CSV for Device Data export/download
- thermostat/remotetemp as command [#1835](https://github.com/emsesp/EMS-ESP32/discussions/1835)
- temperaturesensor id notation with underscore [#1794](https://github.com/emsesp/EMS-ESP32/discussions/1794)
- Change key-names in JSON to be compliant and consistent [#1860](https://github.com/emsesp/EMS-ESP32/issues/1860)
- Updates to webUI [#1920](https://github.com/emsesp/EMS-ESP32/issues/1920)
- Correct firmware naming #1933 [#1933](https://github.com/emsesp/EMS-ESP32/issues/1933)
- Don't start Serial console if not connected to a Serial port. Will initiate manually after a CTRL-C
- WebLog UI matches color schema of the terminal console correctly
- Updated Web libraries, ArduinoJson
- Help page doesn't show detailed tech info if the user is not 'admin' role [#2054](https://github.com/emsesp/EMS-ESP32/issues/2054)
- removed system command `allvalues` and moved to an action called `export`
- Show ems-esp internal devices in device list of system/info
- Scheduler and mqtt run async on systems with psram
- Show IPv6 address type (local/global/ula) in log