Files
EMS-ESP32/src/devices/boiler.h
2020-06-09 18:20:17 +02:00

169 lines
8.5 KiB
C++

/*
* EMS-ESP - https://github.com/proddy/EMS-ESP
* Copyright 2019 Paul Derbyshire
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <http://www.gnu.org/licenses/>.
*/
#ifndef EMSESP_BOILER_H
#define EMSESP_BOILER_H
#include <Arduino.h>
#include <ArduinoJson.h>
#include <uuid/log.h>
#include <string>
#include "emsdevice.h"
#include "telegram.h"
#include "emsesp.h"
#include "helpers.h"
#include "mqtt.h"
namespace emsesp {
class Boiler : public EMSdevice {
public:
Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const std::string & version, const std::string & name, uint8_t flags, uint8_t brand);
virtual void show_values(uuid::console::Shell & shell);
virtual void publish_values();
virtual bool updated_values();
virtual void add_context_menu();
private:
static uuid::log::Logger logger_;
void console_commands(Shell & shell, unsigned int context);
uint8_t last_boilerState = 0xFF; // remember last state of heating and warm water on/off
static constexpr uint8_t EMS_TYPE_UBAParameterWW = 0x33;
static constexpr uint8_t EMS_TYPE_UBAFunctionTest = 0x1D;
static constexpr uint8_t EMS_TYPE_UBAFlags = 0x35;
static constexpr uint8_t EMS_TYPE_UBASetPoints = 0x1A;
static constexpr uint8_t EMS_BOILER_SELFLOWTEMP_HEATING = 20; // was originally 70, changed to 30 for issue #193, then to 20 with issue #344
// UBAParameterWW
uint8_t wWActivated_ = EMS_VALUE_BOOL_NOTSET; // Warm Water activated
uint8_t wWSelTemp_ = EMS_VALUE_UINT_NOTSET; // Warm Water selected temperature
uint8_t wWCircPump_ = EMS_VALUE_BOOL_NOTSET; // Warm Water circulation pump available
uint8_t wWCircPumpMode_ = EMS_VALUE_UINT_NOTSET; // Warm Water circulation pump mode
uint8_t wWCircPumpType_ = EMS_VALUE_BOOL_NOTSET; // Warm Water circulation pump type
uint8_t wWDisinfectTemp_ = EMS_VALUE_UINT_NOTSET; // Warm Water disinfection temperature to prevent infection
uint8_t wWComfort_ = EMS_VALUE_UINT_NOTSET; // WW comfort mode
// MC10Status
uint16_t wwMixTemperature_ = EMS_VALUE_USHORT_NOTSET; // mengertemperatuur
uint16_t wwBufferBoilerTemperature_ = EMS_VALUE_USHORT_NOTSET; // bufferboilertemperatuur
// UBAMonitorFast - 0x18 on EMS1
uint8_t selFlowTemp_ = EMS_VALUE_UINT_NOTSET; // Selected flow temperature
uint16_t curFlowTemp_ = EMS_VALUE_USHORT_NOTSET; // Current flow temperature
uint16_t wwStorageTemp1_ = EMS_VALUE_USHORT_NOTSET; // warm water storage temp 1
uint16_t wwStorageTemp2_ = EMS_VALUE_USHORT_NOTSET; // warm water storage temp 2
uint16_t retTemp_ = EMS_VALUE_USHORT_NOTSET; // Return temperature
uint8_t burnGas_ = EMS_VALUE_BOOL_NOTSET; // Gas on/off
uint8_t fanWork_ = EMS_VALUE_BOOL_NOTSET; // Fan on/off
uint8_t ignWork_ = EMS_VALUE_BOOL_NOTSET; // Ignition on/off
uint8_t heatPmp_ = EMS_VALUE_BOOL_NOTSET; // Boiler pump on/off
uint8_t wWHeat_ = EMS_VALUE_BOOL_NOTSET; // 3-way valve on WW
uint8_t wWCirc_ = EMS_VALUE_BOOL_NOTSET; // Circulation on/off
uint8_t selBurnPow_ = EMS_VALUE_UINT_NOTSET; // Burner max power %
uint8_t curBurnPow_ = EMS_VALUE_UINT_NOTSET; // Burner current power %
uint16_t flameCurr_ = EMS_VALUE_USHORT_NOTSET; // Flame current in micro amps
uint8_t sysPress_ = EMS_VALUE_UINT_NOTSET; // System pressure
char serviceCodeChar_[3] = {'\0'}; // 2 character status/service code
uint16_t serviceCode_ = EMS_VALUE_USHORT_NOTSET; // error/service code
// UBAMonitorSlow - 0x19 on EMS1
int16_t extTemp_ = EMS_VALUE_SHORT_NOTSET; // Outside temperature
uint16_t boilTemp_ = EMS_VALUE_USHORT_NOTSET; // Boiler temperature
uint16_t exhaustTemp_ = EMS_VALUE_USHORT_NOTSET; // Exhaust temperature
uint8_t pumpMod_ = EMS_VALUE_UINT_NOTSET; // Pump modulation %
uint32_t burnStarts_ = EMS_VALUE_ULONG_NOTSET; // # burner restarts
uint32_t burnWorkMin_ = EMS_VALUE_ULONG_NOTSET; // Total burner operating time
uint32_t heatWorkMin_ = EMS_VALUE_ULONG_NOTSET; // Total heat operating time
uint16_t switchTemp_ = EMS_VALUE_USHORT_NOTSET; // Switch temperature
// UBAMonitorWW
uint8_t wWSetTmp_ = EMS_VALUE_UINT_NOTSET; // Warm Water set temperature
uint16_t wWCurTmp_ = EMS_VALUE_USHORT_NOTSET; // Warm Water current temperature
uint16_t wWCurTmp2_ = EMS_VALUE_USHORT_NOTSET; // Warm Water current temperature storage
uint32_t wWStarts_ = EMS_VALUE_ULONG_NOTSET; // Warm Water # starts
uint32_t wWWorkM_ = EMS_VALUE_ULONG_NOTSET; // Warm Water # minutes
uint8_t wWOneTime_ = EMS_VALUE_BOOL_NOTSET; // Warm Water one time function on/off
uint8_t wWDesinfecting_ = EMS_VALUE_BOOL_NOTSET; // Warm Water disinfection on/off
uint8_t wWReadiness_ = EMS_VALUE_BOOL_NOTSET; // Warm Water readiness on/off
uint8_t wWRecharging_ = EMS_VALUE_BOOL_NOTSET; // Warm Water recharge on/off
uint8_t wWTemperatureOK_ = EMS_VALUE_BOOL_NOTSET; // Warm Water temperature ok on/off
uint8_t wWCurFlow_ = EMS_VALUE_UINT_NOTSET; // Warm Water current flow temp in l/min
// UBATotalUptime
uint32_t UBAuptime_ = EMS_VALUE_ULONG_NOTSET; // Total UBA working hours
// UBAParameters
uint8_t heating_temp_ = EMS_VALUE_UINT_NOTSET; // Heating temperature setting on the boiler
uint8_t pump_mod_max_ = EMS_VALUE_UINT_NOTSET; // Boiler circuit pump modulation max. power %
uint8_t pump_mod_min_ = EMS_VALUE_UINT_NOTSET; // Boiler circuit pump modulation min. power
uint8_t tap_water_active_ = EMS_VALUE_BOOL_NOTSET; // Hot tap water is on/off
uint8_t heating_active_ = EMS_VALUE_BOOL_NOTSET; // Central heating is on/off
// heatpump boilers
uint8_t hpModulation_ = EMS_VALUE_UINT_NOTSET; // heatpump modulation in %
uint8_t hpSpeed_ = EMS_VALUE_UINT_NOTSET; // speed 0-100 %
void process_UBAParameterWW(std::shared_ptr<const Telegram> telegram);
void process_UBAMonitorFast(std::shared_ptr<const Telegram> telegram);
void process_UBATotalUptime(std::shared_ptr<const Telegram> telegram);
void process_UBAParameters(std::shared_ptr<const Telegram> telegram);
void process_UBAMonitorWW(std::shared_ptr<const Telegram> telegram);
void process_UBAMonitorFastPlus(std::shared_ptr<const Telegram> telegram);
void process_UBAMonitorSlow(std::shared_ptr<const Telegram> telegram);
void process_UBAMonitorSlowPlus(std::shared_ptr<const Telegram> telegram);
void process_UBAOutdoorTemp(std::shared_ptr<const Telegram> telegram);
void process_UBASetPoints(std::shared_ptr<const Telegram> telegram);
void process_UBAFlags(std::shared_ptr<const Telegram> telegram);
void process_MC10Status(std::shared_ptr<const Telegram> telegram);
void process_UBAMaintenanceStatus(std::shared_ptr<const Telegram> telegram);
void process_UBAMaintenanceSettings(std::shared_ptr<const Telegram> telegram);
void process_UBADHWStatus(std::shared_ptr<const Telegram> telegram);
void process_HPMonitor1(std::shared_ptr<const Telegram> telegram);
void process_HPMonitor2(std::shared_ptr<const Telegram> telegram);
void check_active();
void set_warmwater_temp(const uint8_t temperature);
void set_flow_temp(const uint8_t temperature);
void set_warmwater_mode(const uint8_t comfort);
void set_warmwater_activated(const bool activated);
void set_tapwarmwater_activated(const bool activated);
void set_warmwater_onetime(const bool activated);
void set_warmwater_circulation(const bool activated);
// mqtt callbacks
void boiler_cmd(const char * message);
void boiler_cmd_wwactivated(const char * message);
void boiler_cmd_wwonetime(const char * message);
void boiler_cmd_wwcirculation(const char * message);
void boiler_cmd_wwtemp(const char * message);
};
} // namespace emsesp
#endif