* Paul Derbyshire - https://github.com/proddy/EMS-ESP-Boiler
*/
#pragma once
// these are set as -D build flags during compilation
// they can be set in platformio.ini or alternatively hard coded here
/*
#define WIFI_SSID "<my_ssid>"
#define WIFI_PASSWORD "<my_password>"
#define MQTT_IP "<broker_ip>"
#define MQTT_USER "<broker_username>"
#define MQTT_PASS "<broker_password>"
*/
// default values for shower logic on/off
#define BOILER_SHOWER_TIMER 1 // monitors how long a shower has taken
#define BOILER_SHOWER_ALERT 0 // send alert if showetime exceeded
// trigger settings to determine if hot tap water or the heating is active
#define EMS_BOILER_BURNPOWER_TAPWATER 100
#define EMS_BOILER_SELFLOWTEMP_HEATING 70
//define maximum settable tapwater temperature, not every installation supports 90 degrees
#define EMS_BOILER_TAPWATER_TEMPERATURE_MAX 60
// if using the shower timer, change these settings
#define SHOWER_PAUSE_TIME 15000 // in ms. 15 seconds, max time if water is switched off & on during a shower
#define SHOWER_MIN_DURATION 120000 // in ms. 2 minutes, before recognizing its a shower
#define SHOWER_MAX_DURATION 420000 // in ms. 7 minutes, before trigger a shot of cold water
#define SHOWER_OFFSET_TIME 5000 // in ms. 5 seconds grace time, to calibrate actual time under the shower
#define SHOWER_COLDSHOT_DURATION 10 // in seconds. 10 seconds for cold water before turning back hot water
// The LED for showing connection errors, either onboard or via an external pull-up LED
// can be disabled using -DNO_LED build flag in platformio.ini
#define BOILER_LED LED_BUILTIN // LED_BULLETIN for onboard LED
//#define BOILER_LED D1 // for external LED like on the latest bbqkees boards
// set this if using an external temperature sensor like a DS18B20
#define TEMPERATURE_SENSOR_PIN D7
// logging - EMS_SYS_LOGGING_VERBOSE, EMS_SYS_LOGGING_NONE, EMS_SYS_LOGGING_BASIC (see ems.h)
// this can be changed via the Telnet console using the 'l' command
#define BOILER_DEFAULT_LOGGING EMS_SYS_LOGGING_NONE
//#define BOILER_DEFAULT_LOGGING EMS_SYS_LOGGING_VERBOSE
//#define BOILER_DEFAULT_LOGGING EMS_SYS_LOGGING_BASIC
// By default the EMS bus will be scanned for known devices. You can override this here
// by fixing the Boiler and Thermostat types
// Options are in ems.h and include..
// boilers: EMS_MODEL_BK15, EMS_MODEL_UBA, EMS_MODEL_BC10, EMS_MODEL_MM10, EMS_MODEL_WM10
// thermostats: EMS_MODEL_ES73, EMS_MODEL_RC20, EMS_MODEL_RC30, EMS_MODEL_RC35, EMS_MODEL_EASY
#define MY_BOILER_MODELID EMS_MODEL_NONE
#define MY_THERMOSTAT_MODELID EMS_MODEL_NONE
//#define MY_BOILER_MODELID EMS_MODEL_UBA
//#define MY_THERMOSTAT_MODELID EMS_MODEL_RC20