Merge branch 'dev' of https://github.com/proddy/EMS-ESP into dev
This commit is contained in:
@@ -215,7 +215,7 @@ static_assert(sizeof(RtcmemData) <= (RTCMEM_BLOCKS * 4u), "RTCMEM struct is too
|
||||
|
||||
typedef struct {
|
||||
bool set; // is it a set command?
|
||||
char key[50];
|
||||
char key[55]; // longest is log (alternatively, the log command description could be shortened)
|
||||
char description[110];
|
||||
} command_t;
|
||||
|
||||
|
||||
@@ -107,7 +107,7 @@ static const command_t project_cmds[] PROGMEM = {
|
||||
{true, "master_thermostat [product id]", "set default thermostat to use. No argument lists options"},
|
||||
|
||||
{false, "info", "show current values deciphered from the EMS messages"},
|
||||
{false, "log <n | b | t | s | r | j | v | w [ID] | d [ID]>", "logging: none, basic, thermo, solar, raw, jabber, verbose, watch a type or device"},
|
||||
{false, "log <n | b | t | s | m | r | j | v | w [ID] | d [ID]>", "logging: none, basic, thermo, solar, mixer, raw, jabber, verbose, watch a type or device"},
|
||||
|
||||
#ifdef TESTS
|
||||
{false, "test <n>", "insert a test telegram on to the EMS bus"},
|
||||
@@ -231,6 +231,8 @@ void showInfo() {
|
||||
myDebug_P(PSTR(" System logging set to Thermostat only"));
|
||||
} else if (sysLog == EMS_SYS_LOGGING_SOLARMODULE) {
|
||||
myDebug_P(PSTR(" System logging set to Solar Module only"));
|
||||
} else if (sysLog == EMS_SYS_LOGGING_MIXERMODULE) {
|
||||
myDebug_P(PSTR(" System logging set to Mixer Module only"));
|
||||
} else if (sysLog == EMS_SYS_LOGGING_JABBER) {
|
||||
myDebug_P(PSTR(" System logging set to Jabber"));
|
||||
} else if (sysLog == EMS_SYS_LOGGING_WATCH) {
|
||||
@@ -299,6 +301,18 @@ void showInfo() {
|
||||
// UBAParameterWW
|
||||
_renderBoolValue("Warm Water activated", EMS_Boiler.wWActivated);
|
||||
_renderBoolValue("Warm Water circulation pump available", EMS_Boiler.wWCircPump);
|
||||
myDebug_P(PSTR(" Warm Water circulation pump type: %s"), EMS_Boiler.wWCircPumpType ? "charge pump" : "3-way pump");
|
||||
if (EMS_Boiler.wWCircPumpMode == 7) {
|
||||
myDebug_P(PSTR(" Warm Water circulation pump freq: continuous"));
|
||||
} else {
|
||||
char s[7];
|
||||
char buffer[2];
|
||||
buffer[0] = (EMS_Boiler.wWCircPumpMode % 10) + '0';
|
||||
buffer[1] = '\0';
|
||||
strlcpy(s, buffer, 3);
|
||||
strlcat(s, "x3min", sizeof(s));
|
||||
myDebug_P(PSTR(" Warm Water circulation pump freq: %s"), s);
|
||||
}
|
||||
if (EMS_Boiler.wWComfort == EMS_VALUE_UBAParameterWW_wwComfort_Hot) {
|
||||
myDebug_P(PSTR(" Warm Water comfort setting: Hot"));
|
||||
} else if (EMS_Boiler.wWComfort == EMS_VALUE_UBAParameterWW_wwComfort_Eco) {
|
||||
@@ -309,7 +323,7 @@ void showInfo() {
|
||||
|
||||
_renderIntValue("Warm Water selected temperature", "C", EMS_Boiler.wWSelTemp);
|
||||
_renderIntValue("Warm Water desinfection temperature", "C", EMS_Boiler.wWDesinfectTemp);
|
||||
_renderBoolValue("Warm Water Circulation active", EMS_Boiler.wWCirc);
|
||||
_renderBoolValue("Warm Water circulation active", EMS_Boiler.wWCirc);
|
||||
|
||||
// UBAMonitorWWMessage
|
||||
_renderUShortValue("Warm Water current temperature", "C", EMS_Boiler.wWCurTmp);
|
||||
@@ -635,7 +649,7 @@ bool publishSensorValues() {
|
||||
|
||||
// publish Boiler data via MQTT
|
||||
bool publishEMSValues_boiler() {
|
||||
const size_t capacity = JSON_OBJECT_SIZE(41); // must recalculate if more objects addded https://arduinojson.org/v6/assistant/
|
||||
const size_t capacity = JSON_OBJECT_SIZE(47); // must recalculate if more objects addded https://arduinojson.org/v6/assistant/
|
||||
DynamicJsonDocument doc(capacity);
|
||||
JsonObject rootBoiler = doc.to<JsonObject>();
|
||||
|
||||
@@ -670,6 +684,12 @@ bool publishEMSValues_boiler() {
|
||||
if (EMS_Boiler.wWCircPump != EMS_VALUE_BOOL_NOTSET) {
|
||||
rootBoiler["wWCircPump"] = EMS_Boiler.wWCircPump;
|
||||
}
|
||||
if (EMS_Boiler.wWCircPumpType != EMS_VALUE_BOOL_NOTSET) {
|
||||
rootBoiler["wWCiPuType"] = EMS_Boiler.wWCircPumpType;
|
||||
}
|
||||
if (EMS_Boiler.wWCircPumpMode != EMS_VALUE_INT_NOTSET) {
|
||||
rootBoiler["wWCiPuMode"] = EMS_Boiler.wWCircPumpMode;
|
||||
}
|
||||
if (EMS_Boiler.extTemp > EMS_VALUE_SHORT_NOTSET) {
|
||||
rootBoiler["outdoorTemp"] = (float)EMS_Boiler.extTemp / 10;
|
||||
}
|
||||
@@ -709,6 +729,18 @@ bool publishEMSValues_boiler() {
|
||||
if (EMS_Boiler.wWActivated != EMS_VALUE_BOOL_NOTSET) {
|
||||
rootBoiler["wWOnetime"] = _bool_to_char(s, EMS_Boiler.wWOneTime);
|
||||
}
|
||||
if (EMS_Boiler.wWActivated != EMS_VALUE_BOOL_NOTSET) {
|
||||
rootBoiler["wWDesinfecting"] = _bool_to_char(s, EMS_Boiler.wWDesinfecting);
|
||||
}
|
||||
if (EMS_Boiler.wWActivated != EMS_VALUE_BOOL_NOTSET) {
|
||||
rootBoiler["wWReady"] = _bool_to_char(s, EMS_Boiler.wWReadiness);
|
||||
}
|
||||
if (EMS_Boiler.wWActivated != EMS_VALUE_BOOL_NOTSET) {
|
||||
rootBoiler["wWRecharge"] = _bool_to_char(s, EMS_Boiler.wWRecharging);
|
||||
}
|
||||
if (EMS_Boiler.wWActivated != EMS_VALUE_BOOL_NOTSET) {
|
||||
rootBoiler["wWTempOK"] = _bool_to_char(s, EMS_Boiler.wWTemperaturOK);
|
||||
}
|
||||
if (EMS_Boiler.wWCirc != EMS_VALUE_BOOL_NOTSET) {
|
||||
rootBoiler["wWCirc"] = _bool_to_char(s, EMS_Boiler.wWCirc);
|
||||
}
|
||||
@@ -846,7 +878,19 @@ bool publishEMSValues_thermostat() {
|
||||
} else if (thermoMode == EMS_THERMOSTAT_MODE_NIGHT) {
|
||||
dataThermostat[THERMOSTAT_MODE] = "night";
|
||||
}
|
||||
|
||||
// Render Thermostat Mode2, only if its in Auto mode
|
||||
if (thermoMode == EMS_THERMOSTAT_MODE_AUTO) {
|
||||
thermoMode = _getThermostatMode2(hc_v);
|
||||
if (thermoMode == EMS_THERMOSTAT_MODE_NIGHT) {
|
||||
dataThermostat[THERMOSTAT_MODETYPE] = "night";
|
||||
} else if (thermoMode == EMS_THERMOSTAT_MODE_DAY) {
|
||||
dataThermostat[THERMOSTAT_MODETYPE] = "day";
|
||||
} else if (thermoMode == EMS_THERMOSTAT_MODE_COMFORT) {
|
||||
dataThermostat[THERMOSTAT_MODETYPE] = "comfort";
|
||||
} else if (thermoMode == EMS_THERMOSTAT_MODE_ECO) {
|
||||
dataThermostat[THERMOSTAT_MODETYPE] = "eco";
|
||||
}
|
||||
}
|
||||
|
||||
// if its not nested, send immediately
|
||||
if (!myESP.mqttUseNestedJson()) {
|
||||
@@ -1542,6 +1586,9 @@ void TelnetCommandCallback(uint8_t wc, const char * commandLine) {
|
||||
} else if (strcmp(second_cmd, "s") == 0) {
|
||||
ems_setLogging(EMS_SYS_LOGGING_SOLARMODULE);
|
||||
ok = true;
|
||||
} else if (strcmp(second_cmd, "m") == 0) {
|
||||
ems_setLogging(EMS_SYS_LOGGING_MIXERMODULE);
|
||||
ok = true;
|
||||
} else if (strcmp(second_cmd, "r") == 0) {
|
||||
ems_setLogging(EMS_SYS_LOGGING_RAW);
|
||||
ok = true;
|
||||
|
||||
50
src/ems.cpp
50
src/ems.cpp
@@ -145,6 +145,8 @@ void ems_init() {
|
||||
EMS_Boiler.wWActivated = EMS_VALUE_BOOL_NOTSET; // Warm Water activated
|
||||
EMS_Boiler.wWSelTemp = EMS_VALUE_INT_NOTSET; // Warm Water selected temperature
|
||||
EMS_Boiler.wWCircPump = EMS_VALUE_BOOL_NOTSET; // Warm Water circulation pump available
|
||||
EMS_Boiler.wWCircPumpMode = EMS_VALUE_INT_NOTSET; // Warm Water circulation pump mode
|
||||
EMS_Boiler.wWCircPumpType = EMS_VALUE_BOOL_NOTSET; // Warm Water circulation pump type
|
||||
EMS_Boiler.wWDesinfectTemp = EMS_VALUE_INT_NOTSET; // Warm Water desinfection temperature to prevent infection
|
||||
EMS_Boiler.wWComfort = EMS_VALUE_INT_NOTSET; // WW comfort mode
|
||||
|
||||
@@ -182,6 +184,11 @@ void ems_init() {
|
||||
EMS_Boiler.wWStarts = EMS_VALUE_LONG_NOTSET; // Warm Water # starts
|
||||
EMS_Boiler.wWWorkM = EMS_VALUE_LONG_NOTSET; // Warm Water # minutes
|
||||
EMS_Boiler.wWOneTime = EMS_VALUE_INT_NOTSET; // Warm Water one time function on/off
|
||||
EMS_Boiler.wWDesinfecting = EMS_VALUE_INT_NOTSET; // Warm Water desinfection on/off
|
||||
EMS_Boiler.wWReadiness = EMS_VALUE_INT_NOTSET; // Warm Water readiness on/off
|
||||
EMS_Boiler.wWRecharging = EMS_VALUE_INT_NOTSET; // Warm Water recharge on/off
|
||||
EMS_Boiler.wWTemperaturOK = EMS_VALUE_INT_NOTSET; // Warm Water temperatur ok on/off
|
||||
|
||||
EMS_Boiler.wWCurFlow = EMS_VALUE_INT_NOTSET; // WW current flow temp
|
||||
|
||||
// UBATotalUptimeMessage
|
||||
@@ -319,6 +326,8 @@ void ems_setLogging(_EMS_SYS_LOGGING loglevel, bool quiet) {
|
||||
myDebug_P(PSTR("System Logging set to Thermostat only"));
|
||||
} else if (loglevel == EMS_SYS_LOGGING_SOLARMODULE) {
|
||||
myDebug_P(PSTR("System Logging set to Solar Module only"));
|
||||
} else if (loglevel == EMS_SYS_LOGGING_MIXERMODULE) {
|
||||
myDebug_P(PSTR("System Logging set to Mixer Module only"));
|
||||
} else if (loglevel == EMS_SYS_LOGGING_RAW) {
|
||||
myDebug_P(PSTR("System Logging set to Raw mode"));
|
||||
} else if (loglevel == EMS_SYS_LOGGING_JABBER) {
|
||||
@@ -929,7 +938,7 @@ void _removeTxQueue() {
|
||||
|
||||
/**
|
||||
* Check if hot tap water or heating is active
|
||||
* using a quick hack for checking the heating. Selected Flow Temp >= 70
|
||||
* using a quick hack for checking the heating. Selected Flow Temp >= 30
|
||||
*/
|
||||
void _checkActive() {
|
||||
// hot tap water, using flow to check instead of the burner power
|
||||
@@ -950,6 +959,8 @@ void _checkActive() {
|
||||
void _process_UBAParameterWW(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWActivated, 1); // 0xFF means on
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWCircPump, 6); // 0xFF means on
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWCircPumpMode, 7); // 1=1x3min... 6=6x3min, 7=continuous
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWCircPumpType, 10); // 0 = charge pump, 0xff = 3-way valve
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWSelTemp, 2);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWDesinfectTemp, 8);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWComfort, EMS_OFFSET_UBAParameterWW_wwComfort);
|
||||
@@ -981,6 +992,10 @@ void _process_UBAMonitorWWMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWStarts, 13);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWWorkM, 10);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWOneTime, 5, 1);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWDesinfecting, 5, 2);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWReadiness, 5, 3);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWRecharging, 5, 4);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWTemperaturOK, 5, 5);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWCurFlow, 9);
|
||||
}
|
||||
|
||||
@@ -1068,7 +1083,7 @@ void _process_UBAMonitorFast(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
}
|
||||
|
||||
/**
|
||||
* UBAMonitorFast2 - type 0xE4 - central heating monitor
|
||||
* UBAMonitorFast2 - type 0xE4 - central heating monitor EMS+
|
||||
*/
|
||||
void _process_UBAMonitorFast2(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.selFlowTemp, 6);
|
||||
@@ -1114,7 +1129,7 @@ void _process_UBAMonitorSlow(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
}
|
||||
|
||||
/**
|
||||
* UBAMonitorSlow2 - type 0xE5 - central heating monitor
|
||||
* UBAMonitorSlow2 - type 0xE5 - central heating monitor EMS+
|
||||
*/
|
||||
void _process_UBAMonitorSlow2(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.fanWork, 2, 2);
|
||||
@@ -1128,7 +1143,7 @@ void _process_UBAMonitorSlow2(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
}
|
||||
|
||||
/**
|
||||
* UBAOutdoorTemp - type 0xD1 - external temperature
|
||||
* UBAOutdoorTemp - type 0xD1 - external temperature EMS+
|
||||
*/
|
||||
void _process_UBAOutdoorTemp(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.extTemp, 0);
|
||||
@@ -1304,6 +1319,17 @@ void _process_MMStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
//_setValue(EMS_RxTelegram, &EMS_MixingModule.hc[hc].valveStatus, EMS_OFFSET_MMStatusMessage_valve_status);
|
||||
}
|
||||
|
||||
// Mixer Parameters - 0xAC
|
||||
// We assume MM10 is on HC2 and WM10 is using HC1
|
||||
void _process_MM10ParameterMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
//uint8_t hc = 1; // fixed to HC2
|
||||
//EMS_MixingModule.hc[hc].active = true;
|
||||
|
||||
//_setValue(EMS_RxTelegram, &EMS_MixingModule.hc[hc].flowTemp, EMS_OFFSET_MMStatusMessage_flow_temp);
|
||||
//_setValue(EMS_RxTelegram, &EMS_MixingModule.hc[hc].pumpMod, EMS_OFFSET_MMStatusMessage_pump_mod);
|
||||
//_setValue(EMS_RxTelegram, &EMS_MixingModule.hc[hc].flowSetTemp, EMS_OFFSET_MMStatusMessage_flow_set);
|
||||
}
|
||||
|
||||
/**
|
||||
* type 0x01A5 - data from the Nefit RC1010/3000 thermostat (0x18) and RC300/310s on 0x10
|
||||
* EMS+ messages may come in with different offsets so handle them here
|
||||
@@ -2934,9 +2960,8 @@ const _EMS_Type EMS_Types[] = {
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_HC4, "MMPLUSStatusMessage_HC4", _process_MMPLUSStatusMessage},
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_WWC1, "MMPLUSStatusMessage_WWC1", _process_MMPLUSStatusMessageWW},
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_WWC2, "MMPLUSStatusMessage_WWC2", _process_MMPLUSStatusMessageWW},
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMStatusMessage, "MMStatusMessage", _process_MMStatusMessage}
|
||||
|
||||
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMStatusMessage, "MMStatusMessage", _process_MMStatusMessage},
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MM10ParameterMessage, "MM10ParameterMessage", _process_MM10ParameterMessage}
|
||||
};
|
||||
|
||||
// calculate sizes of arrays at compile time
|
||||
@@ -3030,10 +3055,19 @@ void _printMessage(_EMS_RxTelegram * EMS_RxTelegram, const int8_t show_type) {
|
||||
_debugPrintTelegram(output_str, EMS_RxTelegram, color_s);
|
||||
}
|
||||
} else if (EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_SOLARMODULE) {
|
||||
// only print ones to/from thermostat if logging is set to thermostat only
|
||||
// only print ones to/from solar module if logging is set to solar module only
|
||||
if ((src == EMS_SolarModule.device_id) || (dest == EMS_SolarModule.device_id)) {
|
||||
_debugPrintTelegram(output_str, EMS_RxTelegram, color_s);
|
||||
}
|
||||
} else if (EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_MIXERMODULE) {
|
||||
// only print ones to/from mixer module if logging is set to mixer module only
|
||||
if ((src == EMS_MixingModule.device_id) || (dest == EMS_MixingModule.device_id)) {
|
||||
_debugPrintTelegram(output_str, EMS_RxTelegram, color_s);
|
||||
// also analyse the sequence of instructions prior to instructions to/from mixer module
|
||||
// typically: EMS_TYPE_MM10ParameterMessage(0xAC) - EMS_TYPE_UBASetPoints(0x1A) - EMS_TYPE_UBAFlags(0x35)
|
||||
} else if ((type == EMS_TYPE_MMStatusMessage) || (type == EMS_TYPE_MM10ParameterMessage) || (type == EMS_TYPE_UBASetPoints) || (type == EMS_TYPE_UBAFlags)) {
|
||||
_debugPrintTelegram(output_str, EMS_RxTelegram, color_s);
|
||||
}
|
||||
} else if (EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_DEVICE) {
|
||||
// only print ones to/from DeviceID
|
||||
if ((src == EMS_Sys_Status.emsLogging_ID) || (dest == EMS_Sys_Status.emsLogging_ID)) {
|
||||
|
||||
@@ -125,7 +125,8 @@ typedef enum {
|
||||
EMS_SYS_LOGGING_WATCH, // watch a specific type ID
|
||||
EMS_SYS_LOGGING_BASIC, // only basic read/write messages
|
||||
EMS_SYS_LOGGING_THERMOSTAT, // only telegrams sent from thermostat
|
||||
EMS_SYS_LOGGING_SOLARMODULE, // only telegrams sent from solarmodule
|
||||
EMS_SYS_LOGGING_SOLARMODULE, // only telegrams sent from solar module
|
||||
EMS_SYS_LOGGING_MIXERMODULE, // only telegrams sent from mixer module
|
||||
EMS_SYS_LOGGING_VERBOSE, // everything
|
||||
EMS_SYS_LOGGING_JABBER, // lots of debug output...
|
||||
EMS_SYS_LOGGING_DEVICE // watch the device ID
|
||||
@@ -288,6 +289,8 @@ typedef struct {
|
||||
uint8_t wWActivated; // Warm Water activated
|
||||
uint8_t wWSelTemp; // Warm Water selected temperature
|
||||
uint8_t wWCircPump; // Warm Water circulation pump Available
|
||||
uint8_t wWCircPumpMode; // Warm Water circulation pump mode (1 = 1x3min, ..., 6=6x3min, 7 continuous)
|
||||
uint8_t wWCircPumpType; // Warm Water circulation pump type (0 = charge pump, 0xff = 3-way pump)
|
||||
uint8_t wWDesinfectTemp; // Warm Water desinfection temperature
|
||||
uint8_t wWComfort; // Warm water comfort or ECO mode
|
||||
|
||||
@@ -325,6 +328,10 @@ typedef struct {
|
||||
uint32_t wWStarts; // Warm Water # starts
|
||||
uint32_t wWWorkM; // Warm Water # minutes
|
||||
uint8_t wWOneTime; // Warm Water one time function on/off
|
||||
uint8_t wWDesinfecting; // Warm Water desinfection on/off
|
||||
uint8_t wWReadiness; // Warm Water readiness on/off
|
||||
uint8_t wWRecharging; // Warm Water recharge on/off
|
||||
uint8_t wWTemperaturOK; // Warm Water temperatur ok on/off
|
||||
uint8_t wWCurFlow; // Warm Water current flow in l/min
|
||||
|
||||
// UBATotalUptimeMessage
|
||||
|
||||
@@ -72,6 +72,7 @@
|
||||
#define EMS_OFFSET_MMStatusMessage_flow_temp 1 // flow temperature
|
||||
#define EMS_OFFSET_MMStatusMessage_pump_mod 3 // pump modulation in percent
|
||||
#define EMS_OFFSET_MMStatusMessage_valve_status 4 // valve 0..255
|
||||
#define EMS_TYPE_MM10ParameterMessage 0xAC // mixer parameters
|
||||
|
||||
// Solar Module
|
||||
// Assuming here that the SM200 behaves like SM100
|
||||
|
||||
@@ -32,6 +32,7 @@
|
||||
#define THERMOSTAT_SELTEMP "seltemp" // selected temperature
|
||||
#define THERMOSTAT_HC "hc" // which heating circuit number
|
||||
#define THERMOSTAT_MODE "mode" // mode
|
||||
#define THERMOSTAT_MODETYPE "modetype" // mode type
|
||||
#define THERMOSTAT_DAYTEMP "daytemp" // RC35 specific
|
||||
#define THERMOSTAT_NIGHTTEMP "nighttemp" // RC35 specific
|
||||
#define THERMOSTAT_HOLIDAYTEMP "holidayttemp" // RC35 specific
|
||||
|
||||