Merge branch 'dev' into ft_dashboard
This commit is contained in:
+696
-696
File diff suppressed because it is too large
Load Diff
+1
-1
@@ -107,7 +107,7 @@ telegram_type_id,name,is_fetched
|
||||
0x02A2,RC300Curves,
|
||||
0x02A5,RC300Monitor,
|
||||
0x02A6,RC300Monitor,
|
||||
0x02A7,RC300Monitor,
|
||||
0x02A7,CRFMonitor,
|
||||
0x02A8,RC300Monitor,
|
||||
0x02A9,RC300Monitor,
|
||||
0x02AA,RC300Monitor,
|
||||
|
||||
|
+35
-35
@@ -24,40 +24,40 @@
|
||||
*/
|
||||
|
||||
// Boilers - 0x08
|
||||
{ 8, DeviceType::BOILER, "CS5800i/CS6800i/WLW176i", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
|
||||
{ 8, DeviceType::BOILER, "CS*800i, Logatherm WLW*", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
|
||||
{ 12, DeviceType::BOILER, "C1200W", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{ 64, DeviceType::BOILER, "BK13/BK15/Smartline/GB1x2", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{ 72, DeviceType::BOILER, "GB125/GB135/MC10", DeviceFlags::EMS_DEVICE_FLAG_EMS},
|
||||
{ 64, DeviceType::BOILER, "BK13/BK15, Smartline, GB1*2", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{ 72, DeviceType::BOILER, "Logano GB1*5, Logamatic MC10", DeviceFlags::EMS_DEVICE_FLAG_EMS},
|
||||
{ 81, DeviceType::BOILER, "Cascade CM10", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{ 84, DeviceType::BOILER, "Logamax Plus GB022", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{ 95, DeviceType::BOILER, "Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3", DeviceFlags::EMS_DEVICE_FLAG_HT3},
|
||||
{115, DeviceType::BOILER, "Topline/GB162", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{ 95, DeviceType::BOILER, "Condens 2500/5000W, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3", DeviceFlags::EMS_DEVICE_FLAG_HT3},
|
||||
{115, DeviceType::BOILER, "Topline, GB162", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{121, DeviceType::BOILER, "Cascade MCM10", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{122, DeviceType::BOILER, "Proline", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{123, DeviceType::BOILER, "GBx72/Trendline/Cerapur/Greenstar Si", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{123, DeviceType::BOILER, "GB*72, Trendline, Cerapur, Greenstar Si", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{131, DeviceType::BOILER, "GB212", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{132, DeviceType::BOILER, "GC7000F", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{133, DeviceType::BOILER, "Logano GB125/KB195i/Logamatic MC110", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{133, DeviceType::BOILER, "Logano GB125/KB195i, Logamatic MC110", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{154, DeviceType::BOILER, "Greenstar 30Ri Compact", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{167, DeviceType::BOILER, "Cerapur Aero", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{168, DeviceType::BOILER, "Hybrid Heatpump", DeviceFlags::EMS_DEVICE_FLAG_HYBRID},
|
||||
{170, DeviceType::BOILER, "Logano GB212", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{172, DeviceType::BOILER, "Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
|
||||
{172, DeviceType::BOILER, "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
|
||||
{173, DeviceType::BOILER, "Geo 5xx", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
|
||||
{195, DeviceType::BOILER, "Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{203, DeviceType::BOILER, "Logamax U122/Cerapur", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{195, DeviceType::BOILER, "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{203, DeviceType::BOILER, "Logamax U122, Cerapur", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{206, DeviceType::BOILER, "Ecomline Excellent", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{208, DeviceType::BOILER, "Logamax Plus/GB192/Condens GC9000/Greenstar ErP", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{208, DeviceType::BOILER, "Logamax Plus, GB192, Condens GC9000, Greenstar ErP", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{210, DeviceType::BOILER, "Cascade MC400", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{211, DeviceType::BOILER, "EasyControl Adapter", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{219, DeviceType::BOILER, "Greenstar HIU/Logamax kompakt WS170", DeviceFlags::EMS_DEVICE_FLAG_HIU},
|
||||
{234, DeviceType::BOILER, "Logamax Plus GB122/Condense 2300", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{219, DeviceType::BOILER, "Greenstar HIU, Logamax kompakt WS170", DeviceFlags::EMS_DEVICE_FLAG_HIU},
|
||||
{234, DeviceType::BOILER, "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
|
||||
// Controllers - 0x09 / 0x10 / 0x50
|
||||
{ 68, DeviceType::CONTROLLER, "BC10/RFM20", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
|
||||
{ 68, DeviceType::CONTROLLER, "BC10, RFM20", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
|
||||
{ 81, DeviceType::CONTROLLER, "CM10", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{ 84, DeviceType::CONTROLLER, "GB022", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{ 89, DeviceType::CONTROLLER, "BC10 GB142", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
|
||||
{ 89, DeviceType::CONTROLLER, "BC10, GB142", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
|
||||
{ 95, DeviceType::CONTROLLER, "HT3", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
|
||||
{114, DeviceType::CONTROLLER, "BC10", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
|
||||
{121, DeviceType::CONTROLLER, "MCM10", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
@@ -77,35 +77,35 @@
|
||||
{241, DeviceType::CONTROLLER, "Condens 5000i", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09
|
||||
|
||||
// Thermostat - not currently supporting write operations, like the Easy/100 types - 0x18
|
||||
{202, DeviceType::THERMOSTAT, "Logamatic TC100/Moduline Easy", DeviceFlags::EMS_DEVICE_FLAG_EASY | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18, cannot write
|
||||
{203, DeviceType::THERMOSTAT, "EasyControl/CT200", DeviceFlags::EMS_DEVICE_FLAG_EASY | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18, cannot write
|
||||
{202, DeviceType::THERMOSTAT, "Logamatic TC100, Moduline Easy", DeviceFlags::EMS_DEVICE_FLAG_EASY | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18, cannot write
|
||||
{203, DeviceType::THERMOSTAT, "EasyControl, CT200", DeviceFlags::EMS_DEVICE_FLAG_EASY | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18, cannot write
|
||||
|
||||
// Thermostat - Buderus/Nefit/Bosch specific - 0x17 / 0x10 / 0x18 / 0x19-0x1B for hc2-4 / 0x38
|
||||
{ 4, DeviceType::THERMOSTAT, "UI800/BC400", DeviceFlags::EMS_DEVICE_FLAG_BC400}, // 0x10
|
||||
{ 4, DeviceType::THERMOSTAT, "UI800, BC400", DeviceFlags::EMS_DEVICE_FLAG_BC400}, // 0x10
|
||||
{ 65, DeviceType::THERMOSTAT, "RC10", DeviceFlags::EMS_DEVICE_FLAG_RC20_N},// 0x17
|
||||
{ 67, DeviceType::THERMOSTAT, "RC30", DeviceFlags::EMS_DEVICE_FLAG_RC30_N},// 0x10 - based on RC35
|
||||
{ 77, DeviceType::THERMOSTAT, "RC20/Moduline 300", DeviceFlags::EMS_DEVICE_FLAG_RC20},// 0x17
|
||||
{ 77, DeviceType::THERMOSTAT, "RC20, Moduline 300", DeviceFlags::EMS_DEVICE_FLAG_RC20},// 0x17
|
||||
{ 78, DeviceType::THERMOSTAT, "Moduline 400", DeviceFlags::EMS_DEVICE_FLAG_RC30}, // 0x10
|
||||
{ 79, DeviceType::THERMOSTAT, "RC10/Moduline 100", DeviceFlags::EMS_DEVICE_FLAG_RC10},// 0x17
|
||||
{ 79, DeviceType::THERMOSTAT, "RC10, Moduline 100", DeviceFlags::EMS_DEVICE_FLAG_RC10},// 0x17
|
||||
{ 80, DeviceType::THERMOSTAT, "Moduline 200", DeviceFlags::EMS_DEVICE_FLAG_RC10}, // 0x17
|
||||
{ 86, DeviceType::THERMOSTAT, "RC35", DeviceFlags::EMS_DEVICE_FLAG_RC35}, // 0x10
|
||||
{ 90, DeviceType::THERMOSTAT, "RC10/Moduline 100", DeviceFlags::EMS_DEVICE_FLAG_RC20_N}, // 0x17
|
||||
{ 90, DeviceType::THERMOSTAT, "RC10, Moduline 100", DeviceFlags::EMS_DEVICE_FLAG_RC20_N}, // 0x17
|
||||
{ 93, DeviceType::THERMOSTAT, "RC20RF", DeviceFlags::EMS_DEVICE_FLAG_RC20}, // 0x19
|
||||
{ 94, DeviceType::THERMOSTAT, "RFM20 Remote", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x18
|
||||
{151, DeviceType::THERMOSTAT, "RC25", DeviceFlags::EMS_DEVICE_FLAG_RC25}, // 0x17
|
||||
{157, DeviceType::THERMOSTAT, "RC200/CW100/CR120/CR50", DeviceFlags::EMS_DEVICE_FLAG_RC100}, // 0x18,, CR120 v22 is FLAG_BC400
|
||||
{158, DeviceType::THERMOSTAT, "RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410", DeviceFlags::EMS_DEVICE_FLAG_RC300}, // 0x10
|
||||
{165, DeviceType::THERMOSTAT, "RC100/CR10/Moduline 1000/1010", DeviceFlags::EMS_DEVICE_FLAG_RC100}, // 0x18, 0x38
|
||||
{157, DeviceType::THERMOSTAT, "RC200, CW100, CR120, CR50", DeviceFlags::EMS_DEVICE_FLAG_RC100}, // 0x18,, CR120 v22 is FLAG_BC400
|
||||
{158, DeviceType::THERMOSTAT, "RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410", DeviceFlags::EMS_DEVICE_FLAG_RC300}, // 0x10
|
||||
{165, DeviceType::THERMOSTAT, "RC100, CR10, Moduline 1000/1010", DeviceFlags::EMS_DEVICE_FLAG_RC100}, // 0x18, 0x38
|
||||
{172, DeviceType::THERMOSTAT, "Rego 2000/3000", DeviceFlags::EMS_DEVICE_FLAG_R3000}, // 0x10
|
||||
{215, DeviceType::THERMOSTAT, "Comfort RF", DeviceFlags::EMS_DEVICE_FLAG_CRF | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18
|
||||
{216, DeviceType::THERMOSTAT, "CRF200S", DeviceFlags::EMS_DEVICE_FLAG_CRF | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18
|
||||
{246, DeviceType::THERMOSTAT, "Comfort+2RF", DeviceFlags::EMS_DEVICE_FLAG_CRF | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18
|
||||
{253, DeviceType::THERMOSTAT, "Rego 3000/UI800/WSW196i/BC400", DeviceFlags::EMS_DEVICE_FLAG_BC400}, // 0x10
|
||||
{253, DeviceType::THERMOSTAT, "Rego 3000, UI800, Logatherm WLW186i/WSW196i, Logamatic BC400", DeviceFlags::EMS_DEVICE_FLAG_BC400}, // 0x10
|
||||
|
||||
// Thermostat - Sieger - 0x10 / 0x17
|
||||
{ 66, DeviceType::THERMOSTAT, "ES72/RC20", DeviceFlags::EMS_DEVICE_FLAG_RC20_N}, // 0x17 or remote
|
||||
{ 66, DeviceType::THERMOSTAT, "ES72, RC20", DeviceFlags::EMS_DEVICE_FLAG_RC20_N}, // 0x17 or remote
|
||||
{ 76, DeviceType::THERMOSTAT, "ES73", DeviceFlags::EMS_DEVICE_FLAG_RC30_N}, // 0x10
|
||||
{113, DeviceType::THERMOSTAT, "ES72/RC20", DeviceFlags::EMS_DEVICE_FLAG_RC20_N}, // 0x17
|
||||
{113, DeviceType::THERMOSTAT, "ES72, RC20", DeviceFlags::EMS_DEVICE_FLAG_RC20_N}, // 0x17
|
||||
{156, DeviceType::THERMOSTAT, "ES79", DeviceFlags::EMS_DEVICE_FLAG_RC35}, // 0x10
|
||||
|
||||
// Thermostat - Junkers - 0x10
|
||||
@@ -122,17 +122,17 @@
|
||||
{192, DeviceType::THERMOSTAT, "FW120", DeviceFlags::EMS_DEVICE_FLAG_JUNKERS},
|
||||
|
||||
// Thermostat remote - 0x38
|
||||
{ 3, DeviceType::THERMOSTAT, "RT800/RC220", DeviceFlags::EMS_DEVICE_FLAG_RC100H},
|
||||
{ 3, DeviceType::THERMOSTAT, "RT800, RC220", DeviceFlags::EMS_DEVICE_FLAG_RC100H},
|
||||
{200, DeviceType::THERMOSTAT, "RC100H", DeviceFlags::EMS_DEVICE_FLAG_RC100H},
|
||||
{249, DeviceType::THERMOSTAT, "TR120RF/CR20RF", DeviceFlags::EMS_DEVICE_FLAG_RC100H},
|
||||
{249, DeviceType::THERMOSTAT, "TR120RF, CR20RF", DeviceFlags::EMS_DEVICE_FLAG_RC100H},
|
||||
|
||||
// Solar Modules - 0x30 (for solar), 0x2A, 0x41 (for ww)
|
||||
{ 73, DeviceType::SOLAR, "SM10", DeviceFlags::EMS_DEVICE_FLAG_SM10},
|
||||
{101, DeviceType::SOLAR, "ISM1", DeviceFlags::EMS_DEVICE_FLAG_ISM},
|
||||
{103, DeviceType::SOLAR, "ISM2", DeviceFlags::EMS_DEVICE_FLAG_ISM},
|
||||
{162, DeviceType::SOLAR, "SM50", DeviceFlags::EMS_DEVICE_FLAG_SM100},
|
||||
{163, DeviceType::SOLAR, "SM100/MS100", DeviceFlags::EMS_DEVICE_FLAG_SM100},
|
||||
{164, DeviceType::SOLAR, "SM200/MS200", DeviceFlags::EMS_DEVICE_FLAG_SM100},
|
||||
{163, DeviceType::SOLAR, "SM100, MS100", DeviceFlags::EMS_DEVICE_FLAG_SM100},
|
||||
{164, DeviceType::SOLAR, "SM200, MS200", DeviceFlags::EMS_DEVICE_FLAG_SM100},
|
||||
|
||||
// Mixer Modules - 0x20-0x27 for HC, 0x28-0x29 for WWC and 0x11 for the MP100
|
||||
{ 69, DeviceType::MIXER, "MM10", DeviceFlags::EMS_DEVICE_FLAG_MM10},
|
||||
@@ -163,7 +163,7 @@
|
||||
{206, DeviceType::CONNECT, "Easy Connect", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
|
||||
// Wireless sensor base - 0x50
|
||||
{218, DeviceType::CONNECT, "M200/RFM200", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{218, DeviceType::CONNECT, "M200, RFM200", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{236, DeviceType::CONNECT, "Wireless sensor base", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{238, DeviceType::CONNECT, "Wireless sensor base", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
|
||||
@@ -171,7 +171,7 @@
|
||||
{ 71, DeviceType::SWITCH, "WM10", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
|
||||
// EM10/100 extension module, pump module - 0x15
|
||||
{ 243, DeviceType::EXTENSION, "EM10/EM100", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{ 243, DeviceType::EXTENSION, "EM10, EM100", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
|
||||
// Wireless outdoor sensor T1RF - 0x16
|
||||
{ 220, DeviceType::EXTENSION, "T1RF", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x16
|
||||
@@ -180,8 +180,8 @@
|
||||
{ 74, DeviceType::ALERT, "EM10", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
|
||||
// Gateways - 0x48
|
||||
{189, DeviceType::GATEWAY, "KM200/MB LAN 2", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{252, DeviceType::GATEWAY, "K30RF/MX300", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{189, DeviceType::GATEWAY, "KM200, MB LAN 2", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{252, DeviceType::GATEWAY, "K30RF, MX300", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
|
||||
// Generic - 0x40 or other with no product-id and no version
|
||||
{0, DeviceType::GENERIC, "unknown", DeviceFlags::EMS_DEVICE_FLAG_NONE}
|
||||
|
||||
+1
-1
@@ -95,7 +95,7 @@ void Mqtt::subscribe(const uint8_t device_type, const std::string & topic, mqtt_
|
||||
|
||||
// register in our libary with the callback function.
|
||||
// We store the original topic string without base
|
||||
// TODO check if ok to remove the std::move(topic)
|
||||
// removed std::move(topic) in 3.7.0-dev.43
|
||||
mqtt_subfunctions_.emplace_back(device_type, topic, cb);
|
||||
|
||||
if (!enabled() || !connected()) {
|
||||
|
||||
+1
-1
@@ -256,7 +256,7 @@ class Mqtt {
|
||||
const std::string topic_; // short topic name
|
||||
mqtt_sub_function_p mqtt_subfunction_; // can be empty
|
||||
|
||||
// TODO see if remove &&topic to &topic is ok, so we don't need the std:move
|
||||
// replaced &&topic with &topic in 3.7.0-dev.43, so we prevent the std:move later
|
||||
MQTTSubFunction(uint8_t device_type, const std::string & topic, mqtt_sub_function_p mqtt_subfunction)
|
||||
: device_type_(device_type)
|
||||
, topic_(topic)
|
||||
|
||||
@@ -68,7 +68,6 @@ std::deque<Token> exprToTokens(const std::string & expr) {
|
||||
++p;
|
||||
}
|
||||
const auto s = std::string(b, p);
|
||||
// TODO check works with emplace_back
|
||||
tokens.emplace_back(Token::Type::String, s, -3);
|
||||
if (*p == '\0') {
|
||||
--p;
|
||||
@@ -79,7 +78,6 @@ std::deque<Token> exprToTokens(const std::string & expr) {
|
||||
++p;
|
||||
}
|
||||
const auto s = std::string(b, p);
|
||||
// TODO check works with emplace_back
|
||||
tokens.emplace_back(Token::Type::String, s, -2);
|
||||
--p;
|
||||
} else if (*p == '"') {
|
||||
@@ -209,7 +207,6 @@ std::deque<Token> exprToTokens(const std::string & expr) {
|
||||
break;
|
||||
}
|
||||
const auto s = std::string(1, c);
|
||||
// TODO check works with emplace_back
|
||||
tokens.emplace_back(token, s, precedence, rightAssociative);
|
||||
}
|
||||
}
|
||||
@@ -223,7 +220,6 @@ std::deque<Token> shuntingYard(const std::deque<Token> & tokens) {
|
||||
std::vector<Token> stack;
|
||||
|
||||
// While there are tokens to be read:
|
||||
// TODO check still works with const reference
|
||||
for (auto const & token : tokens) {
|
||||
// Read a token
|
||||
switch (token.type) {
|
||||
|
||||
+2
-2
@@ -285,7 +285,7 @@ class RxService : public EMSbus {
|
||||
const std::shared_ptr<const Telegram> telegram_;
|
||||
|
||||
~QueuedRxTelegram() = default;
|
||||
// TODO check if still works without std::shared_ptr<Telegram> && telegram
|
||||
// removed && from telegram in 3.7.0-dev.43
|
||||
QueuedRxTelegram(uint16_t id, std::shared_ptr<Telegram> telegram)
|
||||
: id_(id)
|
||||
, telegram_(std::move(telegram)) {
|
||||
@@ -415,7 +415,7 @@ class TxService : public EMSbus {
|
||||
const uint16_t validateid_;
|
||||
|
||||
~QueuedTxTelegram() = default;
|
||||
// TODO test this refactor, removing && from std::shared_ptr<Telegram> && telegram
|
||||
// replaced && im std::shared_ptr<Telegram> telegram in 3.7.0-dev.43
|
||||
QueuedTxTelegram(uint16_t id, std::shared_ptr<Telegram> telegram, bool retry, uint16_t validateid)
|
||||
: id_(id)
|
||||
, telegram_(std::move(telegram))
|
||||
|
||||
Reference in New Issue