detect boiler with id 0x60
This commit is contained in:
@@ -204,7 +204,7 @@ class Boiler : public EMSdevice {
|
||||
int16_t cylBottomTemp_; // TB3
|
||||
int16_t aFlowTemp_; // TA1
|
||||
int16_t aRetTemp_; // TR1
|
||||
uint8_t aPump_; // PR1
|
||||
uint8_t aPump_; // PR1 - percent
|
||||
uint8_t valveByPass_; // VR2
|
||||
uint8_t valveBuffer_; // VB1
|
||||
uint8_t valveReturn_; // VR1
|
||||
|
||||
@@ -955,9 +955,9 @@ bool EMSESP::add_device(const uint8_t device_id, const uint8_t product_id, const
|
||||
for (auto & device : device_library_) {
|
||||
if (device.product_id == product_id) {
|
||||
// sometimes boilers share the same productID as controllers
|
||||
// so only add boilers if the device_id is 0x08, which is fixed for EMS
|
||||
// so only add boilers if the device_id is 0x08 or 0x60 or 0x70.., which is fixed for EMS
|
||||
if (device.device_type == DeviceType::BOILER) {
|
||||
if (device_id == EMSdevice::EMS_DEVICE_ID_BOILER
|
||||
if (device_id == EMSdevice::EMS_DEVICE_ID_BOILER || device_id == EMSdevice::EMS_DEVICE_ID_AM200
|
||||
|| (device_id >= EMSdevice::EMS_DEVICE_ID_BOILER_1 && device_id <= EMSdevice::EMS_DEVICE_ID_BOILER_F)) {
|
||||