mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-06 07:49:52 +03:00
fix flodding bus with forceHeatingOff messages, dev3b
This commit is contained in:
@@ -79,15 +79,16 @@ void NetworkSettingsService::manageSTA() {
|
||||
} else {
|
||||
WiFi.begin(_state.ssid.c_str(), _state.password.c_str());
|
||||
}
|
||||
|
||||
// set power after wifi is startet, fixed value for C3_V1
|
||||
if (WiFi.isConnected()) {
|
||||
#ifdef BOARD_C3_MINI_V1
|
||||
// v1 needs this value, see https://github.com/emsesp/EMS-ESP32/pull/620#discussion_r993173979
|
||||
WiFi.setTxPower(WIFI_POWER_8_5dBm); // https://www.wemos.cc/en/latest/c3/c3_mini_1_0_0.html#about-wifi
|
||||
// v1 needs this value, see https://github.com/emsesp/EMS-ESP32/pull/620#discussion_r993173979
|
||||
WiFi.setTxPower(WIFI_POWER_8_5dBm); // https://www.wemos.cc/en/latest/c3/c3_mini_1_0_0.html#about-wifi
|
||||
#else
|
||||
// esp_wifi_set_max_tx_power(_state.tx_power * 4);
|
||||
WiFi.setTxPower((wifi_power_t)(_state.tx_power * 4));
|
||||
// esp_wifi_set_max_tx_power(_state.tx_power * 4);
|
||||
WiFi.setTxPower((wifi_power_t)(_state.tx_power * 4));
|
||||
#endif
|
||||
}
|
||||
} else { // not connected but STA-mode active => disconnect
|
||||
reconfigureWiFiConnection();
|
||||
}
|
||||
@@ -101,8 +102,7 @@ void NetworkSettingsService::WiFiEvent(WiFiEvent_t event) {
|
||||
_stopping = false;
|
||||
}
|
||||
}
|
||||
if (!_stopping
|
||||
&& (event == ARDUINO_EVENT_WIFI_STA_LOST_IP || event == ARDUINO_EVENT_WIFI_STA_DISCONNECTED || event == ARDUINO_EVENT_WIFI_STA_AUTHMODE_CHANGE)) {
|
||||
if (!_stopping && (event == ARDUINO_EVENT_WIFI_STA_LOST_IP || event == ARDUINO_EVENT_WIFI_STA_DISCONNECTED)) {
|
||||
reconfigureWiFiConnection();
|
||||
}
|
||||
}
|
||||
|
||||
@@ -970,15 +970,22 @@ void Boiler::check_active() {
|
||||
tapwaterActive_ = val;
|
||||
char s[12];
|
||||
Mqtt::queue_publish(F_(tapwater_active), Helpers::render_boolean(s, b));
|
||||
if (flowsensor) {
|
||||
EMSESP::tap_water_active(b); // let EMS-ESP know, used in the Shower class
|
||||
}
|
||||
// if (flowsensor) {
|
||||
EMSESP::tap_water_active(b); // let EMS-ESP know, used in the Shower class
|
||||
// }
|
||||
}
|
||||
|
||||
// check forceheatingoff option
|
||||
if (!Helpers::hasValue(forceHeatingOff_, EMS_VALUE_BOOL)) {
|
||||
EMSESP::webSettingsService.read([&](WebSettings & settings) { forceHeatingOff_ = (settings.boiler_heatingoff || selFlowTemp_ == 0) ? 1 : 0; });
|
||||
has_update(&forceHeatingOff_);
|
||||
}
|
||||
static uint32_t lastSendHeatingOff = 0;
|
||||
if (forceHeatingOff_ == EMS_VALUE_BOOL_ON && (uuid::get_uptime_sec() - lastSendHeatingOff) >= 60) {
|
||||
lastSendHeatingOff = uuid::get_uptime_sec();
|
||||
uint8_t data[] = {0, 0, 0, 0};
|
||||
write_command(EMS_TYPE_UBASetPoints, 0, data, sizeof(data), 0);
|
||||
}
|
||||
|
||||
// calculate energy for boiler 0x08 from stored modulation an time in units of 0.01 Wh
|
||||
if (model() != EMS_DEVICE_FLAG_HEATPUMP) {
|
||||
@@ -1246,11 +1253,6 @@ void Boiler::process_UBAMonitorSlow(std::shared_ptr<const Telegram> telegram) {
|
||||
has_update(telegram, burn2WorkMin_, 16, 3); // force to 3 bytes
|
||||
has_update(telegram, heatWorkMin_, 19, 3); // force to 3 bytes
|
||||
has_update(telegram, heatStarts_, 22, 3); // force to 3 bytes
|
||||
|
||||
if (forceHeatingOff_ == EMS_VALUE_BOOL_ON && telegram->dest == 0) {
|
||||
uint8_t data[] = {0, 0, 0, 0};
|
||||
write_command(EMS_TYPE_UBASetPoints, 0, data, sizeof(data), 0);
|
||||
}
|
||||
}
|
||||
|
||||
/*
|
||||
@@ -1281,11 +1283,6 @@ void Boiler::process_UBAMonitorSlowPlus(std::shared_ptr<const Telegram> telegram
|
||||
has_update(telegram, heatWorkMin_, 19, 3); // force to 3 bytes
|
||||
has_update(telegram, heatStarts_, 22, 3); // force to 3 bytes
|
||||
has_update(telegram, heatingPumpMod_, 25);
|
||||
|
||||
if (forceHeatingOff_ == EMS_VALUE_BOOL_ON && telegram->dest == 0 && telegram->offset == 0 && telegram->message_length > 10) {
|
||||
uint8_t data[] = {0, 0, 0, 0};
|
||||
write_command(EMS_TYPE_UBASetPoints, 0, data, sizeof(data), 0);
|
||||
}
|
||||
}
|
||||
|
||||
/*
|
||||
@@ -1537,7 +1534,7 @@ void Boiler::process_UBASetPoints(std::shared_ptr<const Telegram> telegram) {
|
||||
has_update(telegram, wwSetPumpPower_, 2); // ww pump speed/power?
|
||||
|
||||
// overwrite other settings on receive?
|
||||
if (forceHeatingOff_ == EMS_VALUE_BOOL_ON && telegram->dest == 0x08) {
|
||||
if (forceHeatingOff_ == EMS_VALUE_BOOL_ON && telegram->dest == 0x08 && (setFlowTemp_ + setBurnPow_ + wwSetPumpPower_) != 0) {
|
||||
uint8_t data[] = {0, 0, 0, 0};
|
||||
write_command(EMS_TYPE_UBASetPoints, 0, data, sizeof(data), 0);
|
||||
}
|
||||
|
||||
@@ -1 +1 @@
|
||||
#define EMSESP_APP_VERSION "3.6.3-dev.3a"
|
||||
#define EMSESP_APP_VERSION "3.6.3-dev.3b"
|
||||
|
||||
Reference in New Issue
Block a user