mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-12 18:59:51 +03:00
added mqtt for hot water & heating on/off
This commit is contained in:
@@ -61,7 +61,10 @@ uint8_t regularUpdatesCount = 0;
|
||||
|
||||
// boiler
|
||||
#define TOPIC_BOILER_DATA MQTT_BOILER "boiler_data" // for sending boiler values
|
||||
#define TOPIC_BOILER_ MQTT_BOILER "boiler_wwtemp" // warm water selected temp
|
||||
#define TOPIC_BOILER_WARM_WATER_SELECTED_TEMPERATURE MQTT_BOILER "boiler_wwtemp" // warm water selected temp
|
||||
#define TOPIC_BOILER_TAPWATER_ACTIVE MQTT_BOILER "tapwater_active" // if hot tap water is running
|
||||
#define TOPIC_BOILER_HEATING_ACTIVE MQTT_BOILER "heating_active" // if heating is on
|
||||
|
||||
// shower time
|
||||
#define TOPIC_SHOWERTIME MQTT_BOILER "showertime" // for sending shower time results
|
||||
@@ -95,7 +98,6 @@ const unsigned long SHOWER_COLDSHOT_DURATION = 5; // in seconds! how long for co
|
||||
const unsigned long SHOWER_OFFSET_TIME = 0; // 0 seconds grace time, to calibrate actual time under the shower
|
||||
#endif
|
||||
|
||||
const uint8_t SHOWER_BURNPOWER_MIN = 80;
|
||||
typedef struct {
|
||||
bool wifi_connected;
|
||||
bool boiler_online;
|
||||
@@ -106,7 +108,6 @@ typedef struct {
|
||||
|
||||
typedef struct {
|
||||
bool showerOn;
|
||||
bool hotWaterOn;
|
||||
unsigned long timerStart; // ms
|
||||
unsigned long timerPause; // ms
|
||||
unsigned long duration; // ms
|
||||
@@ -124,18 +125,18 @@ netInfo homeNet = {.mqttHost = MQTT_IP,
|
||||
ESPHelper myESP(&homeNet);
|
||||
|
||||
command_t PROGMEM project_cmds[] = {{"s", "show statistics"},
|
||||
{"h", "list supported EMS telegram type ids"},
|
||||
{"h", "list EMS telegram type ids with supported logic"},
|
||||
{"P", "publish all stat to MQTT"},
|
||||
{"v", "[n] set logging (0=none, 1=basic, 2=verbose)"},
|
||||
{"p", "poll ems response on/off (default is off)"},
|
||||
{"T", "thermostat monitoring on/off"},
|
||||
{"S", "shower timer on/off"},
|
||||
{"A", "shower alert on/off"},
|
||||
{"r", "[n] send EMS request (n=telegram type id. Use 'h' for list)"},
|
||||
{"t", "[n] set thermostat temperature to n"},
|
||||
{"p", "toggle EMS Poll response on/off"},
|
||||
{"T", "toggle Thermostat monitoring on/off"},
|
||||
{"S", "toggle Shower timer on/off"},
|
||||
{"A", "toggle shower Alert on/off"},
|
||||
{"r", "[n] send EMS request (n=any telegram type id. Use 'h' for suppported types)"},
|
||||
{"t", "[n] set thermostat temperature"},
|
||||
{"m", "[n] set thermostat mode (1=manual, 2=auto)"},
|
||||
{"w", "[n] set boiler warm water temperature to n (min 30)"},
|
||||
{"a", "[n] boiler warm water on (n=1) or off (n=0)"},
|
||||
{"w", "[n] set boiler warm water temperature (min 30)"},
|
||||
{"a", "[n] boiler warm water (1=on, 2=off)"},
|
||||
{"x", "[n] experimental (warning: for debugging only!)"}};
|
||||
|
||||
// calculates size of an 2d array at compile time
|
||||
@@ -163,6 +164,8 @@ unsigned long timestamp; // for internal timings, via millis()
|
||||
static int connectionStatus = NO_CONNECTION;
|
||||
bool startMQTTsent = false;
|
||||
|
||||
uint8_t last_boilerActive = 0xFF; // for remembering last setting of the tap water or heating on/off
|
||||
|
||||
// toggle for heartbeat LED
|
||||
bool heartbeatEnabled;
|
||||
|
||||
@@ -322,6 +325,10 @@ void showInfo() {
|
||||
|
||||
myDebug("\n\n%sBoiler stats:%s\n", COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
||||
|
||||
// active stats
|
||||
myDebug(" Hot tap water is %s\n", (EMS_Boiler.tapwaterActive ? "running" : "off"));
|
||||
myDebug(" Central Heating is %s\n", (EMS_Boiler.heatingActive ? "active" : "off"));
|
||||
|
||||
// UBAParameterWW
|
||||
_renderBoolValue("Warm Water activated", EMS_Boiler.wWActivated);
|
||||
_renderBoolValue("Warm Water circulation pump available", EMS_Boiler.wWCircPump);
|
||||
@@ -348,7 +355,7 @@ void showInfo() {
|
||||
_renderBoolValue("Circulation pump", EMS_Boiler.wWCirc);
|
||||
_renderIntValue("Burner selected max power", "%", EMS_Boiler.selBurnPow);
|
||||
_renderIntValue("Burner current power", "%", EMS_Boiler.curBurnPow);
|
||||
_renderFloatValue("Flame current", "uA", EMS_Boiler.flameCurr);
|
||||
_renderFloatValue("Flame current", "mA", EMS_Boiler.flameCurr);
|
||||
_renderFloatValue("System pressure", "bar", EMS_Boiler.sysPress);
|
||||
|
||||
// UBAMonitorSlow
|
||||
@@ -392,15 +399,16 @@ void showInfo() {
|
||||
|
||||
// show the Shower Info
|
||||
if (Boiler_Status.shower_timer) {
|
||||
myDebug("\n%sShower stats:%s\n", COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
||||
myDebug(" Hot water is %s\n", (Boiler_Shower.hotWaterOn ? "running" : "stopped"));
|
||||
myDebug(" Shower is %s\n", (Boiler_Shower.showerOn ? "on" : "off"));
|
||||
myDebug("\n%s Shower stats:%s\n", COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
||||
myDebug(" Shower Timer is %s\n", (Boiler_Shower.showerOn ? "active" : "off"));
|
||||
}
|
||||
|
||||
myDebug("\n");
|
||||
}
|
||||
|
||||
// send values to HA via MQTT
|
||||
// a json object is created for the boiler and one for the thermostat
|
||||
// CRC check is done to see if there are changes in the values since the last send to avoid too much wifi traffic
|
||||
void publishValues(bool force) {
|
||||
char s[20]; // for formatting strings
|
||||
|
||||
@@ -435,7 +443,7 @@ void publishValues(bool force) {
|
||||
crc.update(data[i]);
|
||||
}
|
||||
uint32_t checksum = crc.finalize();
|
||||
//myDebug("HASH=%d %08x, len=%d, s=%s\n", checksum, checksum, len, data);
|
||||
//myDebug("Boiler HASH=%d %08x, len=%d, s=%s\n", checksum, checksum, len, data);
|
||||
|
||||
if ((previousBoilerPublishCRC != checksum) || force) {
|
||||
previousBoilerPublishCRC = checksum;
|
||||
@@ -447,6 +455,19 @@ void publishValues(bool force) {
|
||||
myESP.publish(TOPIC_BOILER_DATA, data);
|
||||
}
|
||||
|
||||
// see if the heating or hot tap water has changed, if so send
|
||||
// last_boilerActive stores heating in bit 1 and tap water in bit 2
|
||||
if (last_boilerActive != ((EMS_Boiler.tapwaterActive << 1) + EMS_Boiler.heatingActive)) {
|
||||
if (ems_getLogging() != EMS_SYS_LOGGING_NONE) {
|
||||
myDebug("Publishing hot water and heating state via MQTT\n");
|
||||
}
|
||||
myESP.publish(TOPIC_BOILER_TAPWATER_ACTIVE, EMS_Boiler.tapwaterActive == 1 ? "1" : "0");
|
||||
myESP.publish(TOPIC_BOILER_HEATING_ACTIVE, EMS_Boiler.heatingActive == 1 ? "1" : "0");
|
||||
|
||||
last_boilerActive = ((EMS_Boiler.tapwaterActive << 1) + EMS_Boiler.heatingActive); // remember last state
|
||||
}
|
||||
|
||||
|
||||
// handle the thermostat values separately
|
||||
if (EMS_Sys_Status.emsThermostatEnabled) {
|
||||
// only send thermostat values if we actually have them
|
||||
@@ -476,6 +497,7 @@ void publishValues(bool force) {
|
||||
crc.update(data[i]);
|
||||
}
|
||||
uint32_t checksum = crc.finalize();
|
||||
//myDebug("Thermostat HASH=%d %08x, len=%d, s=%s\n", checksum, checksum, len, data);
|
||||
|
||||
if ((previousThermostatPublishCRC != checksum) || force) {
|
||||
previousThermostatPublishCRC = checksum;
|
||||
@@ -517,7 +539,7 @@ void myDebugCallback() {
|
||||
ems_setPoll(b);
|
||||
break;
|
||||
case 'P':
|
||||
myESP.logger(LOG_HA, "Force publish values");
|
||||
//myESP.logger(LOG_HA, "Force publish values");
|
||||
publishValues(true);
|
||||
break;
|
||||
case 'r': // read command for Boiler or Thermostat
|
||||
@@ -751,6 +773,8 @@ void setup() {
|
||||
myESP.addSubscription(TOPIC_SHOWER_TIMER);
|
||||
myESP.addSubscription(TOPIC_SHOWER_ALERT);
|
||||
myESP.addSubscription(TOPIC_BOILER_WARM_WATER_SELECTED_TEMPERATURE);
|
||||
myESP.addSubscription(TOPIC_BOILER_TAPWATER_ACTIVE);
|
||||
myESP.addSubscription(TOPIC_BOILER_HEATING_ACTIVE);
|
||||
myESP.addSubscription(TOPIC_SHOWER_COLDSHOT);
|
||||
|
||||
myESP.consoleSetCallBackProjectCmds(project_cmds, ArraySize(project_cmds), myDebugCallback); // set up Telnet commands
|
||||
@@ -812,11 +836,8 @@ void regularUpdates() {
|
||||
// only do calls if the EMS is connected and alive
|
||||
if (Boiler_Status.boiler_online) {
|
||||
if ((cycle == 0) && Boiler_Status.thermostat_enabled) {
|
||||
// force get the thermostat mode which is not broadcasted
|
||||
// important! this is only configured for the RC20. Look up the correct telegram type for other thermostat versions
|
||||
if (EMS_ID_THERMOSTAT == 0x17) { // RC20 is type 0x17
|
||||
ems_doReadCommand(EMS_TYPE_RC20Temperature);
|
||||
}
|
||||
// force get the thermostat data which are not usually automatically broadcasted
|
||||
ems_getThermostatTemps();
|
||||
} else if (cycle == 1) {
|
||||
ems_doReadCommand(EMS_TYPE_UBAParameterWW); // get Warm Water values
|
||||
}
|
||||
@@ -880,10 +901,11 @@ void loop() {
|
||||
#endif
|
||||
}
|
||||
|
||||
// publish the values to MQTT (only if there are changes)
|
||||
// if we received new data and flagged for pushing, do it
|
||||
if (EMS_Sys_Status.emsRefreshed) {
|
||||
EMS_Sys_Status.emsRefreshed = false;
|
||||
publishValues(true);
|
||||
publishValues(false);
|
||||
}
|
||||
|
||||
/*
|
||||
@@ -892,13 +914,8 @@ void loop() {
|
||||
if (Boiler_Status.shower_timer) {
|
||||
// if already in cold mode, ignore all this logic until we're out of the cold blast
|
||||
if (!Boiler_Shower.doingColdShot) {
|
||||
// these values come from UBAMonitorFast - type 0x18) which is broadcasted every second so our timings are accurate enough
|
||||
// and no need to fetch the values from the boiler
|
||||
Boiler_Shower.hotWaterOn =
|
||||
((EMS_Boiler.selBurnPow >= SHOWER_BURNPOWER_MIN) && (EMS_Boiler.selFlowTemp == 0) && EMS_Boiler.burnGas);
|
||||
|
||||
// is the hot water running?
|
||||
if (Boiler_Shower.hotWaterOn) {
|
||||
if (EMS_Boiler.tapwaterActive) {
|
||||
// if heater was previously off, start the timer
|
||||
if (Boiler_Shower.timerStart == 0) {
|
||||
// hot water just started...
|
||||
|
||||
Reference in New Issue