mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2026-09-14 22:24:07 +00:00
thermostat mqtt is now json. removed 'low' setting in thermostat mode
This commit is contained in:
@@ -87,7 +87,7 @@ Commands can be issued directly to the EMS bus typing in a letter followed by an
|
||||
- **a** to turn the warm water on and off
|
||||
- **h** to list all the recognized EMS types
|
||||
- **p** to toggle the Polling response on/off. It's not necessary to have Polling enabled to work. I use this for debugging purposes.
|
||||
- **m** to set the thermostat mode from low, manual and clock/auto.
|
||||
- **m** to set the thermostat mode to manual or auto.
|
||||
- **T** to toggle thermostat readings on/off
|
||||
- **S** to toggle the Shower Timer functionality on/off
|
||||
|
||||
@@ -251,9 +251,7 @@ The boiler data is collected and sent as a single JSON object to MQTT TOPIC `hom
|
||||
|
||||
`{"wWCurTmp":"43.0","wWHeat":"on","curFlowTemp":"51.7","retTemp":"48.0","burnGas":"off","heatPmp":"off","fanWork":"off","ignWork":"off","wWCirc":"off","selBurnPow":"0","curBurnPow":"0","sysPress":"1.6","boilTemp":"54.7","pumpMod":"4"}`
|
||||
|
||||
The temperature values of the thermostat as two separate topics `home/boiler/thermostat_currtemp` and `home/boiler/thermostat_seltemp`
|
||||
|
||||
Values sent from HA to set the temperature come in via the subscribed topic `home/boiler/thermostat_temp`
|
||||
Similarly the thermostat values are sent as a json package under a topic named `home/boiler/thermostat_data` with the current mode, room temperature and set temperature.
|
||||
|
||||
These topics can be configured in the `TOPIC_*` defines in `boiler.ino`. Make sure you change the HA configuration too to match.
|
||||
|
||||
|
||||
@@ -52,7 +52,7 @@
|
||||
action:
|
||||
service: mqtt.publish
|
||||
data_template:
|
||||
topic: 'home/boiler/thermostat_temp'
|
||||
topic: 'home/boiler/thermostat_cmd_temp'
|
||||
payload: >
|
||||
{{ states.input_number.thermostat_temp.state }}
|
||||
|
||||
|
||||
+14
-5
@@ -1,11 +1,20 @@
|
||||
- platform: mqtt
|
||||
- platform: mqtt
|
||||
name: Thermostat
|
||||
modes:
|
||||
- low
|
||||
- manual
|
||||
- auto
|
||||
mode_state_topic: "home/boiler/thermostat_mode"
|
||||
temperature_command_topic: "home/boiler/thermostat_temp"
|
||||
temperature_state_topic: "home/boiler/thermostat_seltemp"
|
||||
current_temperature_topic: "home/boiler/thermostat_currtemp"
|
||||
|
||||
mode_state_topic: "home/boiler/thermostat_data"
|
||||
current_temperature_topic: "home/boiler/thermostat_data"
|
||||
temperature_state_topic: "home/boiler/thermostat_data"
|
||||
|
||||
temperature_command_topic: "home/boiler/thermostat_cmd_temp"
|
||||
mode_command_topic: "home/boiler/thermostat_cmd_mode"
|
||||
|
||||
mode_state_template: "{{ value_json.thermostat_mode }}"
|
||||
current_temperature_template: "{{ value_json.thermostat_currtemp }}"
|
||||
temperature_state_template: "{{ value_json.thermostat_seltemp }}"
|
||||
|
||||
temp_step: 0.5
|
||||
|
||||
|
||||
+6
-5
@@ -1,16 +1,19 @@
|
||||
- platform: mqtt
|
||||
state_topic: 'home/boiler/thermostat_currtemp'
|
||||
state_topic: 'home/boiler/thermostat_data'
|
||||
name: 'Current Room Temperature'
|
||||
unit_of_measurement: '°C'
|
||||
value_template: "{{ value_json.thermostat_currtemp }}"
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/boiler/thermostat_seltemp'
|
||||
state_topic: 'home/boiler/thermostat_data'
|
||||
name: 'Current Set Temperature'
|
||||
unit_of_measurement: '°C'
|
||||
value_template: "{{ value_json.thermostat_seltemp }}"
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/boiler/thermostat_mode'
|
||||
state_topic: 'home/boiler/thermostat_data'
|
||||
name: 'Current Mode'
|
||||
value_template: "{{ value_json.thermostat_mode }}"
|
||||
|
||||
# last time boiler was started
|
||||
- platform: template
|
||||
@@ -22,8 +25,6 @@
|
||||
state_topic: 'home/boiler/showertime'
|
||||
name: 'Last shower duration'
|
||||
force_update: true
|
||||
# unit_of_measurement: "minutes"
|
||||
# value_template: '{{ states("sensor.last_shower_duration") | float / 60}}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/boiler/boiler_data'
|
||||
|
||||
@@ -281,7 +281,7 @@ void showInfo() {
|
||||
} else if (EMS_Thermostat.mode == 1) {
|
||||
myDebug("manual\n");
|
||||
} else if (EMS_Thermostat.mode == 2) {
|
||||
myDebug("clock/auto\n");
|
||||
myDebug("auto\n");
|
||||
} else {
|
||||
myDebug("?\n");
|
||||
}
|
||||
@@ -386,13 +386,13 @@ void publishValues() {
|
||||
mqttSend(TOPIC_THERMOSTAT_CURRTEMP, _float_to_char(s, EMS_Thermostat.curr_roomTemp));
|
||||
mqttSend(TOPIC_THERMOSTAT_SELTEMP, _float_to_char(s, EMS_Thermostat.setpoint_roomTemp));
|
||||
|
||||
// send mode 0=low, 1=manual, 2=clock/auto
|
||||
// send mode 0=low, 1=manual, 2=auto
|
||||
if (EMS_Thermostat.mode == 0) {
|
||||
mqttSend(TOPIC_THERMOSTAT_MODE, "low");
|
||||
} else if (EMS_Thermostat.mode == 1) {
|
||||
mqttSend(TOPIC_THERMOSTAT_MODE, "manual");
|
||||
} else {
|
||||
mqttSend(TOPIC_THERMOSTAT_MODE, "auto"); // must be auto
|
||||
mqttSend(TOPIC_THERMOSTAT_MODE, "auto");
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
+105
-58
@@ -51,14 +51,19 @@ uint8_t regularUpdatesCount = 0;
|
||||
#define MQTT_BOILER MQTT_BASE HOSTNAME "/"
|
||||
#define TOPIC_START MQTT_BOILER MQTT_TOPIC_START
|
||||
|
||||
#define TOPIC_THERMOSTAT_TEMP MQTT_BOILER "thermostat_temp" // for received thermostat temp changes
|
||||
#define TOPIC_THERMOSTAT_CURRTEMP MQTT_BOILER "thermostat_currtemp" // current temperature
|
||||
#define TOPIC_THERMOSTAT_SELTEMP MQTT_BOILER "thermostat_seltemp" // selected temperature
|
||||
#define TOPIC_THERMOSTAT_MODE MQTT_BOILER "thermostat_mode" // selected temperature
|
||||
// thermostat
|
||||
#define TOPIC_THERMOSTAT_DATA MQTT_BOILER "thermostat_data" // for sending thermostat values
|
||||
#define TOPIC_THERMOSTAT_CMD_TEMP MQTT_BOILER "thermostat_cmd_temp" // for received thermostat temp changes
|
||||
#define TOPIC_THERMOSTAT_CMD_MODE MQTT_BOILER "thermostat_cmd_mode" // for received thermostat mode changes
|
||||
#define TOPIC_THERMOSTAT_CURRTEMP "thermostat_currtemp" // current temperature
|
||||
#define TOPIC_THERMOSTAT_SELTEMP "thermostat_seltemp" // selected temperature
|
||||
#define TOPIC_THERMOSTAT_MODE "thermostat_mode" // mode
|
||||
|
||||
// boiler
|
||||
#define TOPIC_BOILER_DATA MQTT_BOILER "boiler_data" // for sending boiler values
|
||||
#define TOPIC_BOILER_WARM_WATER_SELECTED_TEMPERATURE MQTT_BOILER "boiler_wwtemp" // warm water selected temp
|
||||
|
||||
#define TOPIC_BOILER_DATA MQTT_BOILER "boiler_data" // for sending boiler values
|
||||
|
||||
// shower time
|
||||
#define TOPIC_SHOWERTIME MQTT_BOILER "showertime" // for sending shower time results
|
||||
#define TOPIC_SHOWER_ALARM "shower_alarm" // for notifying HA that shower time has reached its limit
|
||||
#define TOPIC_SHOWER_TIMER MQTT_BOILER "shower_timer" // toggle switch for enabling the shower logic
|
||||
@@ -128,7 +133,7 @@ command_t PROGMEM project_cmds[] = {{"s", "show statistics"},
|
||||
{"A", "shower alert on/off"},
|
||||
{"r", "[n] send EMS request (n=telegram type id. Use 'h' for list)"},
|
||||
{"t", "[n] set thermostat temperature to n"},
|
||||
{"m", "[n] set thermostat mode (0=low, 1=manual, 2=clock)"},
|
||||
{"m", "[n] set thermostat mode (1=manual, 2=auto)"},
|
||||
{"w", "[n] set boiler warm water temperature to n (min 30)"},
|
||||
{"a", "[n] boiler warm water on (n=1) or off (n=0)"},
|
||||
{"x", "[n] experimental (warning: for debugging only!)"}};
|
||||
@@ -146,8 +151,9 @@ _Boiler_Shower Boiler_Shower;
|
||||
// Debugger to telnet
|
||||
#define myDebug(x, ...) myESP.printf(x, ##__VA_ARGS__);
|
||||
|
||||
// CRC
|
||||
uint32_t previousPublishCRC = 0;
|
||||
// CRC checks
|
||||
uint32_t previousBoilerPublishCRC = 0;
|
||||
uint32_t previousThermostatPublishCRC = 0;
|
||||
|
||||
// Times
|
||||
const unsigned long POLL_TIMEOUT_ERR = 10000; // if no signal from boiler for last 10 seconds, assume its offline
|
||||
@@ -378,9 +384,9 @@ void showInfo() {
|
||||
} else if (EMS_Thermostat.mode == 1) {
|
||||
myDebug("manual\n");
|
||||
} else if (EMS_Thermostat.mode == 2) {
|
||||
myDebug("clock/auto\n");
|
||||
myDebug("auto\n");
|
||||
} else {
|
||||
myDebug("?\n");
|
||||
myDebug("<%d>\n", EMS_Thermostat.mode);
|
||||
}
|
||||
}
|
||||
|
||||
@@ -395,35 +401,35 @@ void showInfo() {
|
||||
}
|
||||
|
||||
// send values to HA via MQTT
|
||||
void publishValues() {
|
||||
void publishValues(bool force) {
|
||||
char s[20]; // for formatting strings
|
||||
|
||||
// Boiler values as one JSON object
|
||||
StaticJsonBuffer<512> jsonBuffer;
|
||||
char data[512];
|
||||
JsonObject & root = jsonBuffer.createObject();
|
||||
JsonObject & rootBoiler = jsonBuffer.createObject();
|
||||
|
||||
root["wWSelTemp"] = _int_to_char(s, EMS_Boiler.wWSelTemp);
|
||||
root["wWActivated"] = _bool_to_char(s, EMS_Boiler.wWActivated);
|
||||
root["wWCurTmp"] = _float_to_char(s, EMS_Boiler.wWCurTmp);
|
||||
root["wWHeat"] = _bool_to_char(s, EMS_Boiler.wWHeat);
|
||||
root["curFlowTemp"] = _float_to_char(s, EMS_Boiler.curFlowTemp);
|
||||
root["retTemp"] = _float_to_char(s, EMS_Boiler.retTemp);
|
||||
root["burnGas"] = _bool_to_char(s, EMS_Boiler.burnGas);
|
||||
root["heatPmp"] = _bool_to_char(s, EMS_Boiler.heatPmp);
|
||||
root["fanWork"] = _bool_to_char(s, EMS_Boiler.fanWork);
|
||||
root["ignWork"] = _bool_to_char(s, EMS_Boiler.ignWork);
|
||||
root["wWCirc"] = _bool_to_char(s, EMS_Boiler.wWCirc);
|
||||
root["selBurnPow"] = _int_to_char(s, EMS_Boiler.selBurnPow);
|
||||
root["curBurnPow"] = _int_to_char(s, EMS_Boiler.curBurnPow);
|
||||
root["sysPress"] = _float_to_char(s, EMS_Boiler.sysPress);
|
||||
root["boilTemp"] = _float_to_char(s, EMS_Boiler.boilTemp);
|
||||
root["pumpMod"] = _int_to_char(s, EMS_Boiler.pumpMod);
|
||||
rootBoiler["wWSelTemp"] = _int_to_char(s, EMS_Boiler.wWSelTemp);
|
||||
rootBoiler["wWActivated"] = _bool_to_char(s, EMS_Boiler.wWActivated);
|
||||
rootBoiler["wWCurTmp"] = _float_to_char(s, EMS_Boiler.wWCurTmp);
|
||||
rootBoiler["wWHeat"] = _bool_to_char(s, EMS_Boiler.wWHeat);
|
||||
rootBoiler["curFlowTemp"] = _float_to_char(s, EMS_Boiler.curFlowTemp);
|
||||
rootBoiler["retTemp"] = _float_to_char(s, EMS_Boiler.retTemp);
|
||||
rootBoiler["burnGas"] = _bool_to_char(s, EMS_Boiler.burnGas);
|
||||
rootBoiler["heatPmp"] = _bool_to_char(s, EMS_Boiler.heatPmp);
|
||||
rootBoiler["fanWork"] = _bool_to_char(s, EMS_Boiler.fanWork);
|
||||
rootBoiler["ignWork"] = _bool_to_char(s, EMS_Boiler.ignWork);
|
||||
rootBoiler["wWCirc"] = _bool_to_char(s, EMS_Boiler.wWCirc);
|
||||
rootBoiler["selBurnPow"] = _int_to_char(s, EMS_Boiler.selBurnPow);
|
||||
rootBoiler["curBurnPow"] = _int_to_char(s, EMS_Boiler.curBurnPow);
|
||||
rootBoiler["sysPress"] = _float_to_char(s, EMS_Boiler.sysPress);
|
||||
rootBoiler["boilTemp"] = _float_to_char(s, EMS_Boiler.boilTemp);
|
||||
rootBoiler["pumpMod"] = _int_to_char(s, EMS_Boiler.pumpMod);
|
||||
|
||||
size_t len = root.measureLength();
|
||||
root.printTo(data, len + 1); // form the json string
|
||||
size_t len = rootBoiler.measureLength();
|
||||
rootBoiler.printTo(data, len + 1); // form the json string
|
||||
|
||||
// calculate hash
|
||||
// calculate hash and send values if something has changed, to save unnecessary wifi traffic
|
||||
CRC32 crc;
|
||||
for (size_t i = 0; i < len - 1; i++) {
|
||||
crc.update(data[i]);
|
||||
@@ -431,11 +437,10 @@ void publishValues() {
|
||||
uint32_t checksum = crc.finalize();
|
||||
//myDebug("HASH=%d %08x, len=%d, s=%s\n", checksum, checksum, len, data);
|
||||
|
||||
// only send values if something has changed, to save unnecessary wifi traffic
|
||||
if (previousPublishCRC != checksum) {
|
||||
previousPublishCRC = checksum;
|
||||
if ((previousBoilerPublishCRC != checksum) || force) {
|
||||
previousBoilerPublishCRC = checksum;
|
||||
if (ems_getLogging() != EMS_SYS_LOGGING_NONE) {
|
||||
myDebug("Publishing data to MQTT topics\n");
|
||||
myDebug("Publishing boiler data via MQTT\n");
|
||||
}
|
||||
|
||||
// send values via MQTT
|
||||
@@ -445,20 +450,41 @@ void publishValues() {
|
||||
// handle the thermostat values separately
|
||||
if (EMS_Sys_Status.emsThermostatEnabled) {
|
||||
// only send thermostat values if we actually have them
|
||||
if (((int)EMS_Thermostat.curr_roomTemp == (int)0) || ((int)EMS_Thermostat.setpoint_roomTemp == (int)0)) {
|
||||
if (((int)EMS_Thermostat.curr_roomTemp == (int)0) || ((int)EMS_Thermostat.setpoint_roomTemp == (int)0))
|
||||
return;
|
||||
|
||||
// build json object
|
||||
JsonObject & rootThermostat = jsonBuffer.createObject();
|
||||
rootThermostat[TOPIC_THERMOSTAT_CURRTEMP] = _float_to_char(s, EMS_Thermostat.curr_roomTemp);
|
||||
rootThermostat[TOPIC_THERMOSTAT_SELTEMP] = _float_to_char(s, EMS_Thermostat.setpoint_roomTemp);
|
||||
|
||||
// send mode 0=low, 1=manual, 2=auto
|
||||
if (EMS_Thermostat.mode == 0) {
|
||||
rootThermostat[TOPIC_THERMOSTAT_MODE] = "low";
|
||||
} else if (EMS_Thermostat.mode == 1) {
|
||||
rootThermostat[TOPIC_THERMOSTAT_MODE] = "manual";
|
||||
} else {
|
||||
rootThermostat[TOPIC_THERMOSTAT_MODE] = "auto";
|
||||
}
|
||||
|
||||
myESP.publish(TOPIC_THERMOSTAT_CURRTEMP, _float_to_char(s, EMS_Thermostat.curr_roomTemp));
|
||||
myESP.publish(TOPIC_THERMOSTAT_SELTEMP, _float_to_char(s, EMS_Thermostat.setpoint_roomTemp));
|
||||
size_t len = rootThermostat.measureLength();
|
||||
rootThermostat.printTo(data, len + 1); // form the json string
|
||||
|
||||
// send mode 0=low, 1=manual, 2=clock/auto
|
||||
if (EMS_Thermostat.mode == 0) {
|
||||
myESP.publish(TOPIC_THERMOSTAT_MODE, "low");
|
||||
} else if (EMS_Thermostat.mode == 1) {
|
||||
myESP.publish(TOPIC_THERMOSTAT_MODE, "manual");
|
||||
} else {
|
||||
myESP.publish(TOPIC_THERMOSTAT_MODE, "auto"); // must be auto
|
||||
// calculate new CRC
|
||||
crc.reset();
|
||||
for (size_t i = 0; i < len - 1; i++) {
|
||||
crc.update(data[i]);
|
||||
}
|
||||
uint32_t checksum = crc.finalize();
|
||||
|
||||
if ((previousThermostatPublishCRC != checksum) || force) {
|
||||
previousThermostatPublishCRC = checksum;
|
||||
if (ems_getLogging() != EMS_SYS_LOGGING_NONE) {
|
||||
myDebug("Publishing thermostat data via MQTT\n");
|
||||
}
|
||||
|
||||
// send values via MQTT
|
||||
myESP.publish(TOPIC_THERMOSTAT_DATA, data);
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -492,7 +518,7 @@ void myDebugCallback() {
|
||||
break;
|
||||
case 'P':
|
||||
myESP.logger(LOG_HA, "Force publish values");
|
||||
publishValues();
|
||||
publishValues(true);
|
||||
break;
|
||||
case 'r': // read command for Boiler or Thermostat
|
||||
ems_doReadCommand((uint8_t)strtol(&cmd[2], 0, 16));
|
||||
@@ -504,7 +530,10 @@ void myDebugCallback() {
|
||||
ems_printAllTypes();
|
||||
break;
|
||||
case 'm': // set thermostat mode
|
||||
ems_setThermostatMode(cmd[2] - '0');
|
||||
if ((cmd[2] - '0') == 1)
|
||||
ems_setThermostatMode(1);
|
||||
else if ((cmd[2] - '0') == 2)
|
||||
ems_setThermostatMode(2);
|
||||
break;
|
||||
case 'w': // set warm water temp
|
||||
ems_setWarmWaterTemp((uint8_t)strtol(&cmd[2], 0, 10));
|
||||
@@ -551,14 +580,26 @@ void MQTTcallback(char * topic, byte * payload, uint8_t length) {
|
||||
return;
|
||||
}
|
||||
|
||||
// thermostat_temp
|
||||
if (strcmp(topic, TOPIC_THERMOSTAT_TEMP) == 0) {
|
||||
// thermostat temp changes
|
||||
if (strcmp(topic, TOPIC_THERMOSTAT_CMD_TEMP) == 0) {
|
||||
float f = strtof((char *)payload, 0);
|
||||
char s[10];
|
||||
myDebug("MQTT topic: thermostat_temp value %s\n", _float_to_char(s, f));
|
||||
myDebug("MQTT topic: thermostat temp value %s\n", _float_to_char(s, f));
|
||||
ems_setThermostatTemp(f);
|
||||
// publish back so HA is immediately updated
|
||||
publishValues();
|
||||
publishValues(true);
|
||||
return;
|
||||
}
|
||||
|
||||
// thermostat mode changes
|
||||
if (strcmp(topic, TOPIC_THERMOSTAT_CMD_MODE) == 0) {
|
||||
payload[length] = '\0'; // add null terminator
|
||||
myDebug("MQTT topic: thermostat mode value %s\n", payload);
|
||||
if (strcmp((char *)payload, "auto") == 0) {
|
||||
ems_setThermostatMode(2);
|
||||
} else if (strcmp((char *)payload, "manual") == 0) {
|
||||
ems_setThermostatMode(1);
|
||||
}
|
||||
return;
|
||||
}
|
||||
|
||||
@@ -570,7 +611,7 @@ void MQTTcallback(char * topic, byte * payload, uint8_t length) {
|
||||
ems_setWarmWaterTemp(i);
|
||||
#endif
|
||||
// publish back so HA is immediately updated
|
||||
publishValues();
|
||||
publishValues(true);
|
||||
return;
|
||||
}
|
||||
|
||||
@@ -667,6 +708,11 @@ void _initBoiler() {
|
||||
updateHeartbeat();
|
||||
}
|
||||
|
||||
// call PublishValues without forcing, so using CRC to see if we really need to publish
|
||||
void do_publishValues() {
|
||||
publishValues(false);
|
||||
}
|
||||
|
||||
//
|
||||
// SETUP
|
||||
// Note: we don't init the UART here as we should wait until everything is loaded first. It's done in loop()
|
||||
@@ -686,8 +732,8 @@ void setup() {
|
||||
#endif
|
||||
|
||||
// Timers using Ticker library
|
||||
publishValuesTimer.attach(PUBLISHVALUES_TIME, publishValues); // post HA values
|
||||
systemCheckTimer.attach(SYSTEMCHECK_TIME, systemCheck); // check if Boiler is online
|
||||
publishValuesTimer.attach(PUBLISHVALUES_TIME, do_publishValues); // post HA values
|
||||
systemCheckTimer.attach(SYSTEMCHECK_TIME, do_systemCheck); // check if Boiler is online
|
||||
|
||||
#ifndef NO_TX
|
||||
regularUpdatesTimer.attach((REGULARUPDATES_TIME / MAX_MANUAL_CALLS), regularUpdates); // regular reads from the EMS
|
||||
@@ -700,7 +746,8 @@ void setup() {
|
||||
myESP.setMQTTCallback(MQTTcallback);
|
||||
myESP.addSubscription(MQTT_HA);
|
||||
myESP.addSubscription(TOPIC_START);
|
||||
myESP.addSubscription(TOPIC_THERMOSTAT_TEMP);
|
||||
myESP.addSubscription(TOPIC_THERMOSTAT_CMD_TEMP);
|
||||
myESP.addSubscription(TOPIC_THERMOSTAT_CMD_MODE);
|
||||
myESP.addSubscription(TOPIC_SHOWER_TIMER);
|
||||
myESP.addSubscription(TOPIC_SHOWER_ALERT);
|
||||
myESP.addSubscription(TOPIC_BOILER_WARM_WATER_SELECTED_TEMPERATURE);
|
||||
@@ -748,7 +795,7 @@ void heartbeat() {
|
||||
}
|
||||
|
||||
// do a healthcheck every now and then to see if we connections
|
||||
void systemCheck() {
|
||||
void do_systemCheck() {
|
||||
// first do a system check to see if there is still a connection to the EMS
|
||||
Boiler_Status.boiler_online = ((timestamp - EMS_Sys_Status.emsLastPoll) < POLL_TIMEOUT_ERR);
|
||||
if (!Boiler_Status.boiler_online) {
|
||||
@@ -836,7 +883,7 @@ void loop() {
|
||||
// if we received new data and flagged for pushing, do it
|
||||
if (EMS_Sys_Status.emsRefreshed) {
|
||||
EMS_Sys_Status.emsRefreshed = false;
|
||||
publishValues();
|
||||
publishValues(true);
|
||||
}
|
||||
|
||||
/*
|
||||
|
||||
@@ -149,7 +149,7 @@ typedef struct {
|
||||
typedef struct {
|
||||
float setpoint_roomTemp; // current set temp
|
||||
float curr_roomTemp; // current room temp
|
||||
uint8_t mode; // 0=low, 1=manual, 2=clock/auto
|
||||
uint8_t mode; // 0=low, 1=manual, 2=auto
|
||||
uint8_t hour;
|
||||
uint8_t minute;
|
||||
uint8_t second;
|
||||
|
||||
Reference in New Issue
Block a user