mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 16:29:51 +03:00
Merge pull request #362 from MichaelDvP/dev_mqtt
Fahrenheit for HA-climate min/max
This commit is contained in:
@@ -386,6 +386,8 @@ void Thermostat::publish_ha_config_hc(std::shared_ptr<Thermostat::HeatingCircuit
|
||||
char uniq_id_s[30];
|
||||
char temp_cmd_s[30];
|
||||
char mode_cmd_s[30];
|
||||
char min_s[10];
|
||||
char max_s[10];
|
||||
|
||||
// https://github.com/emsesp/EMS-ESP32/issues/325#issuecomment-1022249093
|
||||
// before you had to have a seltemp and roomtemp for the HA to work, now its optional
|
||||
@@ -437,8 +439,8 @@ void Thermostat::publish_ha_config_hc(std::shared_ptr<Thermostat::HeatingCircuit
|
||||
doc["curr_temp_tpl"] = currtemp_s;
|
||||
}
|
||||
|
||||
doc["min_temp"] = "5";
|
||||
doc["max_temp"] = "30";
|
||||
doc["min_temp"] = Helpers::render_value(min_s, 5, 0, EMSESP::system_.fahrenheit() ? 2 : 0);
|
||||
doc["max_temp"] = Helpers::render_value(max_s, 30, 0, EMSESP::system_.fahrenheit() ? 2 : 0);
|
||||
doc["temp_step"] = "0.5";
|
||||
|
||||
// the HA climate component only responds to auto, heat and off
|
||||
|
||||
Reference in New Issue