Merge pull request #362 from MichaelDvP/dev_mqtt

Fahrenheit for HA-climate min/max
This commit is contained in:
Proddy
2022-02-17 10:47:20 +01:00
committed by GitHub

View File

@@ -386,6 +386,8 @@ void Thermostat::publish_ha_config_hc(std::shared_ptr<Thermostat::HeatingCircuit
char uniq_id_s[30];
char temp_cmd_s[30];
char mode_cmd_s[30];
char min_s[10];
char max_s[10];
// https://github.com/emsesp/EMS-ESP32/issues/325#issuecomment-1022249093
// before you had to have a seltemp and roomtemp for the HA to work, now its optional
@@ -437,8 +439,8 @@ void Thermostat::publish_ha_config_hc(std::shared_ptr<Thermostat::HeatingCircuit
doc["curr_temp_tpl"] = currtemp_s;
}
doc["min_temp"] = "5";
doc["max_temp"] = "30";
doc["min_temp"] = Helpers::render_value(min_s, 5, 0, EMSESP::system_.fahrenheit() ? 2 : 0);
doc["max_temp"] = Helpers::render_value(max_s, 30, 0, EMSESP::system_.fahrenheit() ? 2 : 0);
doc["temp_step"] = "0.5";
// the HA climate component only responds to auto, heat and off