chore: update generated files for v3.8.3-dev.0

This commit is contained in:
MichaelDvP
2026-05-13 09:32:00 +00:00
committed by github-actions[bot]
parent 07a9bd5f33
commit 5f6d156f63
2 changed files with 25 additions and 25 deletions

View File

@@ -5376,9 +5376,9 @@ uint8
| hc1.switchprogmode | switch program mode | enum | | true | HC | 55 | 1 | 1 |
int8
| hc1.redthreshold | reduction threshold | int8 (>=12<=22) | C | true | HC | 56 | 1 | 1/2 |
uint8
| hc1.solarinfl | solar influence | uint8 (>=-5<=4294967295) | C | true | HC | 57 | 1 | 1 |
| hc1.currsolarinfl | current solar influence | uint8 | C | false | HC | 58 | 1 | 1/10 |
int8
| hc1.solarinfl | solar influence | int8 (>=-5<=4294967295) | C | true | HC | 57 | 1 | 1 |
| hc1.currsolarinfl | current solar influence | int8 | C | false | HC | 58 | 1 | 1/10 |
| hc1.heatingpid | heating PID | enum | | true | HC | 59 | 1 | 1 |
| hc1.pumpopt | pump optimization | boolean | | true | HC | 60 | 1 | 1 |
uint8
@@ -5985,9 +5985,9 @@ uint8
| hc1.switchprogmode | switch program mode | enum | | true | HC | 55 | 1 | 1 |
int8
| hc1.redthreshold | reduction threshold | int8 (>=12<=22) | C | true | HC | 56 | 1 | 1/2 |
uint8
| hc1.solarinfl | solar influence | uint8 (>=-5<=4294967295) | C | true | HC | 57 | 1 | 1 |
| hc1.currsolarinfl | current solar influence | uint8 | C | false | HC | 58 | 1 | 1/10 |
int8
| hc1.solarinfl | solar influence | int8 (>=-5<=4294967295) | C | true | HC | 57 | 1 | 1 |
| hc1.currsolarinfl | current solar influence | int8 | C | false | HC | 58 | 1 | 1/10 |
| hc1.heatingpid | heating PID | enum | | true | HC | 59 | 1 | 1 |
| hc1.pumpopt | pump optimization | boolean | | true | HC | 60 | 1 | 1 |
uint8
@@ -6137,9 +6137,9 @@ uint8
| hc1.switchprogmode | switch program mode | enum | | true | HC | 55 | 1 | 1 |
int8
| hc1.redthreshold | reduction threshold | int8 (>=12<=22) | C | true | HC | 56 | 1 | 1/2 |
uint8
| hc1.solarinfl | solar influence | uint8 (>=-5<=4294967295) | C | true | HC | 57 | 1 | 1 |
| hc1.currsolarinfl | current solar influence | uint8 | C | false | HC | 58 | 1 | 1/10 |
int8
| hc1.solarinfl | solar influence | int8 (>=-5<=4294967295) | C | true | HC | 57 | 1 | 1 |
| hc1.currsolarinfl | current solar influence | int8 | C | false | HC | 58 | 1 | 1/10 |
| hc1.heatingpid | heating PID | enum | | true | HC | 59 | 1 | 1 |
| hc1.pumpopt | pump optimization | boolean | | true | HC | 60 | 1 | 1 |
uint8
@@ -6304,9 +6304,9 @@ uint8
| hc1.switchprogmode | switch program mode | enum | | true | HC | 55 | 1 | 1 |
int8
| hc1.redthreshold | reduction threshold | int8 (>=12<=22) | C | true | HC | 56 | 1 | 1/2 |
uint8
| hc1.solarinfl | solar influence | uint8 (>=-5<=4294967295) | C | true | HC | 57 | 1 | 1 |
| hc1.currsolarinfl | current solar influence | uint8 | C | false | HC | 58 | 1 | 1/10 |
int8
| hc1.solarinfl | solar influence | int8 (>=-5<=4294967295) | C | true | HC | 57 | 1 | 1 |
| hc1.currsolarinfl | current solar influence | int8 | C | false | HC | 58 | 1 | 1/10 |
| hc1.heatingpid | heating PID | enum | | true | HC | 59 | 1 | 1 |
| hc1.pumpopt | pump optimization | boolean | | true | HC | 60 | 1 | 1 |
uint8
@@ -6498,9 +6498,9 @@ uint8
| hc1.switchprogmode | switch program mode | enum | | true | HC | 55 | 1 | 1 |
int8
| hc1.redthreshold | reduction threshold | int8 (>=12<=22) | C | true | HC | 56 | 1 | 1/2 |
uint8
| hc1.solarinfl | solar influence | uint8 (>=-5<=4294967295) | C | true | HC | 57 | 1 | 1 |
| hc1.currsolarinfl | current solar influence | uint8 | C | false | HC | 58 | 1 | 1/10 |
int8
| hc1.solarinfl | solar influence | int8 (>=-5<=4294967295) | C | true | HC | 57 | 1 | 1 |
| hc1.currsolarinfl | current solar influence | int8 | C | false | HC | 58 | 1 | 1/10 |
| hc1.heatingpid | heating PID | enum | | true | HC | 59 | 1 | 1 |
| hc1.pumpopt | pump optimization | boolean | | true | HC | 60 | 1 | 1 |
uint8

View File

@@ -4057,8 +4057,8 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"UI800, BC400",thermostat,4,hc1.cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,54,1
"UI800, BC400",thermostat,4,hc1.switchprogmode,switch program mode,enum [level\|absolute] (>=0<=0), ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,55,1
"UI800, BC400",thermostat,4,hc1.redthreshold,reduction threshold,int8 (>=12<=22),C,true,number.thermostat_hc1_reduction_threshold,number.thermostat_hc1_redthreshold,6,1,1/2,56,1
"UI800, BC400",thermostat,4,hc1.solarinfl,solar influence,uint8 (>=-5<=4294967295),C,true,number.thermostat_hc1_solar_influence,number.thermostat_hc1_solarinfl,6,1,1,57,1
"UI800, BC400",thermostat,4,hc1.currsolarinfl,current solar influence,uint8,C,false,sensor.thermostat_hc1_current_solar_influence,sensor.thermostat_hc1_currsolarinfl,6,1,1/10,58,1
"UI800, BC400",thermostat,4,hc1.solarinfl,solar influence,int8 (>=-5<=4294967295),C,true,number.thermostat_hc1_solar_influence,number.thermostat_hc1_solarinfl,6,1,1,57,1
"UI800, BC400",thermostat,4,hc1.currsolarinfl,current solar influence,int8,C,false,sensor.thermostat_hc1_current_solar_influence,sensor.thermostat_hc1_currsolarinfl,6,1,1/10,58,1
"UI800, BC400",thermostat,4,hc1.heatingpid,heating PID,enum [fast\|medium\|slow] (>=0<=0), ,true,select.thermostat_hc1_heating_PID,select.thermostat_hc1_heatingpid,6,1,1,59,1
"UI800, BC400",thermostat,4,hc1.pumpopt,pump optimization,boolean (>=0<=0), ,true,switch.thermostat_hc1_pump_optimization,switch.thermostat_hc1_pumpopt,6,1,1,60,1
"UI800, BC400",thermostat,4,hc1.inttimefloor,integral time floor,uint8 (>=160<=320),minutes,true,number.thermostat_hc1_integral_time_floor,number.thermostat_hc1_inttimefloor,6,1,10,61,1
@@ -4447,8 +4447,8 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"RC200, CW100, CR120, CR50",thermostat,157,hc1.cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,54,1
"RC200, CW100, CR120, CR50",thermostat,157,hc1.switchprogmode,switch program mode,enum [level\|absolute] (>=0<=0), ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,55,1
"RC200, CW100, CR120, CR50",thermostat,157,hc1.redthreshold,reduction threshold,int8 (>=12<=22),C,true,number.thermostat_hc1_reduction_threshold,number.thermostat_hc1_redthreshold,6,1,1/2,56,1
"RC200, CW100, CR120, CR50",thermostat,157,hc1.solarinfl,solar influence,uint8 (>=-5<=4294967295),C,true,number.thermostat_hc1_solar_influence,number.thermostat_hc1_solarinfl,6,1,1,57,1
"RC200, CW100, CR120, CR50",thermostat,157,hc1.currsolarinfl,current solar influence,uint8,C,false,sensor.thermostat_hc1_current_solar_influence,sensor.thermostat_hc1_currsolarinfl,6,1,1/10,58,1
"RC200, CW100, CR120, CR50",thermostat,157,hc1.solarinfl,solar influence,int8 (>=-5<=4294967295),C,true,number.thermostat_hc1_solar_influence,number.thermostat_hc1_solarinfl,6,1,1,57,1
"RC200, CW100, CR120, CR50",thermostat,157,hc1.currsolarinfl,current solar influence,int8,C,false,sensor.thermostat_hc1_current_solar_influence,sensor.thermostat_hc1_currsolarinfl,6,1,1/10,58,1
"RC200, CW100, CR120, CR50",thermostat,157,hc1.heatingpid,heating PID,enum [fast\|medium\|slow] (>=0<=0), ,true,select.thermostat_hc1_heating_PID,select.thermostat_hc1_heatingpid,6,1,1,59,1
"RC200, CW100, CR120, CR50",thermostat,157,hc1.pumpopt,pump optimization,boolean (>=0<=0), ,true,switch.thermostat_hc1_pump_optimization,switch.thermostat_hc1_pumpopt,6,1,1,60,1
"RC200, CW100, CR120, CR50",thermostat,157,hc1.inttimefloor,integral time floor,uint8 (>=160<=320),minutes,true,number.thermostat_hc1_integral_time_floor,number.thermostat_hc1_inttimefloor,6,1,10,61,1
@@ -4545,8 +4545,8 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410",thermostat,158,hc1.cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,54,1
"RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410",thermostat,158,hc1.switchprogmode,switch program mode,enum [level\|absolute] (>=0<=0), ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,55,1
"RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410",thermostat,158,hc1.redthreshold,reduction threshold,int8 (>=12<=22),C,true,number.thermostat_hc1_reduction_threshold,number.thermostat_hc1_redthreshold,6,1,1/2,56,1
"RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410",thermostat,158,hc1.solarinfl,solar influence,uint8 (>=-5<=4294967295),C,true,number.thermostat_hc1_solar_influence,number.thermostat_hc1_solarinfl,6,1,1,57,1
"RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410",thermostat,158,hc1.currsolarinfl,current solar influence,uint8,C,false,sensor.thermostat_hc1_current_solar_influence,sensor.thermostat_hc1_currsolarinfl,6,1,1/10,58,1
"RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410",thermostat,158,hc1.solarinfl,solar influence,int8 (>=-5<=4294967295),C,true,number.thermostat_hc1_solar_influence,number.thermostat_hc1_solarinfl,6,1,1,57,1
"RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410",thermostat,158,hc1.currsolarinfl,current solar influence,int8,C,false,sensor.thermostat_hc1_current_solar_influence,sensor.thermostat_hc1_currsolarinfl,6,1,1/10,58,1
"RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410",thermostat,158,hc1.heatingpid,heating PID,enum [fast\|medium\|slow] (>=0<=0), ,true,select.thermostat_hc1_heating_PID,select.thermostat_hc1_heatingpid,6,1,1,59,1
"RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410",thermostat,158,hc1.pumpopt,pump optimization,boolean (>=0<=0), ,true,switch.thermostat_hc1_pump_optimization,switch.thermostat_hc1_pumpopt,6,1,1,60,1
"RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410",thermostat,158,hc1.inttimefloor,integral time floor,uint8 (>=160<=320),minutes,true,number.thermostat_hc1_integral_time_floor,number.thermostat_hc1_inttimefloor,6,1,10,61,1
@@ -4652,8 +4652,8 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"Rego 2000/3000",thermostat,172,hc1.cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,54,1
"Rego 2000/3000",thermostat,172,hc1.switchprogmode,switch program mode,enum [level\|absolute] (>=0<=0), ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,55,1
"Rego 2000/3000",thermostat,172,hc1.redthreshold,reduction threshold,int8 (>=12<=22),C,true,number.thermostat_hc1_reduction_threshold,number.thermostat_hc1_redthreshold,6,1,1/2,56,1
"Rego 2000/3000",thermostat,172,hc1.solarinfl,solar influence,uint8 (>=-5<=4294967295),C,true,number.thermostat_hc1_solar_influence,number.thermostat_hc1_solarinfl,6,1,1,57,1
"Rego 2000/3000",thermostat,172,hc1.currsolarinfl,current solar influence,uint8,C,false,sensor.thermostat_hc1_current_solar_influence,sensor.thermostat_hc1_currsolarinfl,6,1,1/10,58,1
"Rego 2000/3000",thermostat,172,hc1.solarinfl,solar influence,int8 (>=-5<=4294967295),C,true,number.thermostat_hc1_solar_influence,number.thermostat_hc1_solarinfl,6,1,1,57,1
"Rego 2000/3000",thermostat,172,hc1.currsolarinfl,current solar influence,int8,C,false,sensor.thermostat_hc1_current_solar_influence,sensor.thermostat_hc1_currsolarinfl,6,1,1/10,58,1
"Rego 2000/3000",thermostat,172,hc1.heatingpid,heating PID,enum [fast\|medium\|slow] (>=0<=0), ,true,select.thermostat_hc1_heating_PID,select.thermostat_hc1_heatingpid,6,1,1,59,1
"Rego 2000/3000",thermostat,172,hc1.pumpopt,pump optimization,boolean (>=0<=0), ,true,switch.thermostat_hc1_pump_optimization,switch.thermostat_hc1_pumpopt,6,1,1,60,1
"Rego 2000/3000",thermostat,172,hc1.inttimefloor,integral time floor,uint8 (>=160<=320),minutes,true,number.thermostat_hc1_integral_time_floor,number.thermostat_hc1_inttimefloor,6,1,10,61,1
@@ -4777,8 +4777,8 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"Rego 3000, UI800, Logamatic BC400",thermostat,253,hc1.cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,54,1
"Rego 3000, UI800, Logamatic BC400",thermostat,253,hc1.switchprogmode,switch program mode,enum [level\|absolute] (>=0<=0), ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,55,1
"Rego 3000, UI800, Logamatic BC400",thermostat,253,hc1.redthreshold,reduction threshold,int8 (>=12<=22),C,true,number.thermostat_hc1_reduction_threshold,number.thermostat_hc1_redthreshold,6,1,1/2,56,1
"Rego 3000, UI800, Logamatic BC400",thermostat,253,hc1.solarinfl,solar influence,uint8 (>=-5<=4294967295),C,true,number.thermostat_hc1_solar_influence,number.thermostat_hc1_solarinfl,6,1,1,57,1
"Rego 3000, UI800, Logamatic BC400",thermostat,253,hc1.currsolarinfl,current solar influence,uint8,C,false,sensor.thermostat_hc1_current_solar_influence,sensor.thermostat_hc1_currsolarinfl,6,1,1/10,58,1
"Rego 3000, UI800, Logamatic BC400",thermostat,253,hc1.solarinfl,solar influence,int8 (>=-5<=4294967295),C,true,number.thermostat_hc1_solar_influence,number.thermostat_hc1_solarinfl,6,1,1,57,1
"Rego 3000, UI800, Logamatic BC400",thermostat,253,hc1.currsolarinfl,current solar influence,int8,C,false,sensor.thermostat_hc1_current_solar_influence,sensor.thermostat_hc1_currsolarinfl,6,1,1/10,58,1
"Rego 3000, UI800, Logamatic BC400",thermostat,253,hc1.heatingpid,heating PID,enum [fast\|medium\|slow] (>=0<=0), ,true,select.thermostat_hc1_heating_PID,select.thermostat_hc1_heatingpid,6,1,1,59,1
"Rego 3000, UI800, Logamatic BC400",thermostat,253,hc1.pumpopt,pump optimization,boolean (>=0<=0), ,true,switch.thermostat_hc1_pump_optimization,switch.thermostat_hc1_pumpopt,6,1,1,60,1
"Rego 3000, UI800, Logamatic BC400",thermostat,253,hc1.inttimefloor,integral time floor,uint8 (>=160<=320),minutes,true,number.thermostat_hc1_integral_time_floor,number.thermostat_hc1_inttimefloor,6,1,10,61,1
Can't render this file because it is too large.