Merge pull request #225 from SpaceTeddy:dev
PR: rename and tap water loading
This commit is contained in:
@@ -371,7 +371,7 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
|
||||
### Changed
|
||||
|
||||
- Renamed project from EMS-ESP-Boiler to EMS-ESP since it's kinda EMS generic now
|
||||
- Support for RC20F and RFM20 (https://github.com/proddy/EMS-ESP/issues/18)
|
||||
- Support for RC20RF and RFM20 (https://github.com/proddy/EMS-ESP/issues/18)
|
||||
- Moved all EMS device information into a separate file `ems_devices.h` so no longer need to touch `ems.h`
|
||||
- Telnet commands can be strings now and output is suspended when typing
|
||||
|
||||
@@ -392,7 +392,7 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
|
||||
|
||||
- Scanning known EMS Devices now ignores duplicates (https://github.com/proddy/EMS-ESP/pull/30)
|
||||
- ServiceCode stored as a two byte char
|
||||
- Support for RC20F and RFM20 (https://github.com/proddy/EMS-ESP/issues/18)
|
||||
- Support for RC20RF and RFM20 (https://github.com/proddy/EMS-ESP/issues/18)
|
||||
|
||||
## [1.2.3] 2019-01-03
|
||||
|
||||
|
||||
@@ -592,6 +592,9 @@ void publishValues(bool force) {
|
||||
|
||||
if (EMS_Boiler.wWActivated != EMS_VALUE_INT_NOTSET)
|
||||
rootBoiler["wWActivated"] = _bool_to_char(s, EMS_Boiler.wWActivated);
|
||||
|
||||
if (EMS_Boiler.wWActivated != EMS_VALUE_INT_NOTSET)
|
||||
rootBoiler["wWOnetime"] = _bool_to_char(s, EMS_Boiler.wWOneTime);
|
||||
|
||||
if (EMS_Boiler.burnGas != EMS_VALUE_INT_NOTSET)
|
||||
rootBoiler["burnGas"] = _bool_to_char(s, EMS_Boiler.burnGas);
|
||||
@@ -1506,8 +1509,9 @@ void MQTTCallback(unsigned int type, const char * topic, const char * message) {
|
||||
// this is used for example for comfort, flowtemp
|
||||
myESP.mqttSubscribe(TOPIC_BOILER_CMD);
|
||||
|
||||
// these two need to be unqiue topics
|
||||
// these three need to be unqiue topics
|
||||
myESP.mqttSubscribe(TOPIC_BOILER_CMD_WWACTIVATED);
|
||||
myESP.mqttSubscribe(TOPIC_BOILER_CMD_WWONETIME);
|
||||
myESP.mqttSubscribe(TOPIC_BOILER_CMD_WWTEMP);
|
||||
|
||||
// generic incoming MQTT command for EMS-ESP
|
||||
@@ -1621,6 +1625,16 @@ void MQTTCallback(unsigned int type, const char * topic, const char * message) {
|
||||
return;
|
||||
}
|
||||
|
||||
// wwOneTime
|
||||
if (strcmp(topic, TOPIC_BOILER_CMD_WWONETIME) == 0) {
|
||||
if (message[0] == '1' || strcmp(message, "on") == 0) {
|
||||
ems_setWarmWaterOnetime(true);
|
||||
} else if (message[0] == '0' || strcmp(message, "off") == 0) {
|
||||
ems_setWarmWaterOnetime(false);
|
||||
}
|
||||
return;
|
||||
}
|
||||
|
||||
// boiler wwtemp changes
|
||||
if (strcmp(topic, TOPIC_BOILER_CMD_WWTEMP) == 0) {
|
||||
uint8_t t = atoi((char *)message);
|
||||
|
||||
32
src/ems.cpp
32
src/ems.cpp
@@ -137,16 +137,16 @@ const _EMS_Type EMS_Types[] = {
|
||||
{EMS_MODEL_RC10, EMS_TYPE_RC10Set, "RC10Set", _process_RC10Set},
|
||||
{EMS_MODEL_RC10, EMS_TYPE_RC10StatusMessage, "RC10StatusMessage", _process_RC10StatusMessage},
|
||||
|
||||
// RC20 and RC20F
|
||||
// RC20 and RC20RF
|
||||
{EMS_MODEL_RC20, EMS_TYPE_RCOutdoorTempMessage, "RCOutdoorTempMessage", _process_RCOutdoorTempMessage},
|
||||
{EMS_MODEL_RC20, EMS_TYPE_RCTime, "RCTime", _process_RCTime},
|
||||
{EMS_MODEL_RC20, EMS_TYPE_RC20Set, "RC20Set", _process_RC20Set},
|
||||
{EMS_MODEL_RC20, EMS_TYPE_RC20StatusMessage, "RC20StatusMessage", _process_RC20StatusMessage},
|
||||
|
||||
{EMS_MODEL_RC20F, EMS_TYPE_RCOutdoorTempMessage, "RCOutdoorTempMessage", _process_RCOutdoorTempMessage},
|
||||
{EMS_MODEL_RC20F, EMS_TYPE_RCTime, "RCTime", _process_RCTime},
|
||||
{EMS_MODEL_RC20F, EMS_TYPE_RC20Set, "RC20Set", _process_RC20Set},
|
||||
{EMS_MODEL_RC20F, EMS_TYPE_RC20StatusMessage, "RC20StatusMessage", _process_RC20StatusMessage},
|
||||
{EMS_MODEL_RC20RF, EMS_TYPE_RCOutdoorTempMessage, "RCOutdoorTempMessage", _process_RCOutdoorTempMessage},
|
||||
{EMS_MODEL_RC20RF, EMS_TYPE_RCTime, "RCTime", _process_RCTime},
|
||||
{EMS_MODEL_RC20RF, EMS_TYPE_RC20Set, "RC20Set", _process_RC20Set},
|
||||
{EMS_MODEL_RC20RF, EMS_TYPE_RC20StatusMessage, "RC20StatusMessage", _process_RC20StatusMessage},
|
||||
|
||||
// RC30
|
||||
{EMS_MODEL_RC30, EMS_TYPE_RCOutdoorTempMessage, "RCOutdoorTempMessage", _process_RCOutdoorTempMessage},
|
||||
@@ -1292,6 +1292,28 @@ void _process_UBAMonitorWWMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
EMS_Boiler.wWCurFlow = _toByte(9);
|
||||
}
|
||||
|
||||
/**
|
||||
* Activate / De-activate One Time warm water 0x35
|
||||
* true = on, false = off
|
||||
*/
|
||||
void ems_setWarmWaterOnetime(bool activated) {
|
||||
myDebug_P(PSTR("Setting boiler warm water OneTime loading %s"), activated ? "on" : "off");
|
||||
|
||||
_EMS_TxTelegram EMS_TxTelegram = EMS_TX_TELEGRAM_NEW; // create new Tx
|
||||
EMS_TxTelegram.timestamp = millis(); // set timestamp
|
||||
EMS_Sys_Status.txRetryCount = 0; // reset retry counter
|
||||
|
||||
EMS_TxTelegram.action = EMS_TX_TELEGRAM_WRITE;
|
||||
EMS_TxTelegram.dest = EMS_Boiler.device_id;
|
||||
EMS_TxTelegram.type = EMS_TYPE_UBAFlags;
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_UBAParameterWW_wwOneTime;
|
||||
EMS_TxTelegram.length = EMS_MIN_TELEGRAM_LENGTH;
|
||||
EMS_TxTelegram.type_validate = EMS_ID_NONE; // don't validate
|
||||
EMS_TxTelegram.dataValue = (activated ? 0x22 : 0x02); // 0x22 is on, 0x02 is off for RC20RF
|
||||
|
||||
EMS_TxQueue.push(EMS_TxTelegram);
|
||||
}
|
||||
|
||||
/**
|
||||
* UBAMonitorFast - type 0x18 - central heating monitor part 1 (25 bytes long)
|
||||
* received every 10 seconds
|
||||
|
||||
@@ -408,6 +408,7 @@ void ems_setThermostatMode(uint8_t mode, uint8_t hc);
|
||||
void ems_setWarmWaterTemp(uint8_t temperature);
|
||||
void ems_setFlowTemp(uint8_t temperature);
|
||||
void ems_setWarmWaterActivated(bool activated);
|
||||
void ems_setWarmWaterOnetime(bool activated);
|
||||
void ems_setWarmTapWaterActivated(bool activated);
|
||||
void ems_setPoll(bool b);
|
||||
void ems_setLogging(_EMS_SYS_LOGGING loglevel, bool silent = false);
|
||||
|
||||
@@ -26,6 +26,7 @@
|
||||
#define EMS_TYPE_UBAMaintenanceStatusMessage 0x1C // is an automatic monitor broadcast
|
||||
#define EMS_TYPE_UBAParameterWW 0x33
|
||||
#define EMS_TYPE_UBATotalUptimeMessage 0x14
|
||||
#define EMS_TYPE_UBAFlags 0x35
|
||||
#define EMS_TYPE_UBAMaintenanceSettingsMessage 0x15
|
||||
#define EMS_TYPE_UBAParametersMessage 0x16
|
||||
#define EMS_TYPE_UBASetPoints 0x1A
|
||||
@@ -33,6 +34,7 @@
|
||||
|
||||
#define EMS_OFFSET_UBAParameterWW_wwtemp 2 // WW Temperature
|
||||
#define EMS_OFFSET_UBAParameterWW_wwactivated 1 // WW Activated
|
||||
#define EMS_OFFSET_UBAParameterWW_wwOneTime 5 // WW OneTime loading
|
||||
#define EMS_OFFSET_UBAParameterWW_wwComfort 9 // WW is in comfort or eco mode
|
||||
#define EMS_VALUE_UBAParameterWW_wwComfort_Hot 0x00 // the value for hot
|
||||
#define EMS_VALUE_UBAParameterWW_wwComfort_Eco 0xD8 // the value for eco
|
||||
@@ -171,7 +173,7 @@ typedef enum {
|
||||
EMS_MODEL_ES73,
|
||||
EMS_MODEL_RC10,
|
||||
EMS_MODEL_RC20,
|
||||
EMS_MODEL_RC20F,
|
||||
EMS_MODEL_RC20RF,
|
||||
EMS_MODEL_RC30,
|
||||
EMS_MODEL_RC35,
|
||||
EMS_MODEL_EASY,
|
||||
@@ -283,7 +285,7 @@ const _Thermostat_Device Thermostat_Devices[] = {
|
||||
// Buderus/Nefit
|
||||
{EMS_MODEL_RC10, 79, 0x17, "RC10/Moduline 100", EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC20, 77, 0x17, "RC20/Moduline 300", EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC20F, 93, 0x18, "RC20F", EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC20RF, 93, 0x18, "RC20RF", EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC30, 67, 0x10, "RC30", EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC30, 78, 0x10, "RC30/Moduline 400", EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC35, 86, 0x10, "RC35", EMS_THERMOSTAT_WRITE_YES},
|
||||
|
||||
@@ -44,6 +44,7 @@
|
||||
|
||||
#define TOPIC_BOILER_CMD "boiler_cmd" // for receiving boiler commands via MQTT
|
||||
#define TOPIC_BOILER_CMD_WWACTIVATED "boiler_cmd_wwactivated" // change water on/off
|
||||
#define TOPIC_BOILER_CMD_WWONETIME "boiler_cmd_wwonetime" // warm warter one time loading
|
||||
#define TOPIC_BOILER_CMD_WWTEMP "boiler_cmd_wwtemp" // wwtemp changes via MQTT
|
||||
#define TOPIC_BOILER_CMD_COMFORT "comfort" // ww comfort setting via MQTT
|
||||
#define TOPIC_BOILER_CMD_FLOWTEMP "flowtemp" // flowtemp value via MQTT
|
||||
|
||||