@@ -201,7 +201,8 @@ char * _short_to_char(char * s, int16_t value, uint8_t decimals = 1) {
|
||||
// divide by 2
|
||||
strlcpy(s, ltoa(value / 2, s2, 10), 10);
|
||||
strlcat(s, ".", 10);
|
||||
strlcat(s, ltoa(value % 2, s2, 10), 10);
|
||||
strlcat(s, ((value & 0x01) ? "5" : "0"), 10);
|
||||
|
||||
} else {
|
||||
strlcpy(s, ltoa(value / (decimals * 10), s2, 10), 10);
|
||||
strlcat(s, ".", 10);
|
||||
|
||||
@@ -41,17 +41,17 @@
|
||||
#define EMS_OFFSET_UBASetPoints_flowtemp 0 // flow temp
|
||||
|
||||
// Other
|
||||
#define EMS_TYPE_SM10Monitor 0x97 // SM10Monitor
|
||||
#define EMS_TYPE_SM100Monitor 0x0262 // SM100Monitor
|
||||
#define EMS_TYPE_SM100Status 0x0264 // SM100Status
|
||||
#define EMS_TYPE_SM100Status2 0x026A // SM100Status2
|
||||
#define EMS_TYPE_SM100Energy 0x028E // SM100Energy
|
||||
#define EMS_TYPE_HPMonitor1 0xE3 // HeatPump Monitor 1
|
||||
#define EMS_TYPE_HPMonitor2 0xE5 // HeatPump Monitor 2
|
||||
#define EMS_TYPE_SM10Monitor 0x97 // SM10Monitor
|
||||
#define EMS_TYPE_SM100Monitor 0x0262 // SM100Monitor
|
||||
#define EMS_TYPE_SM100Status 0x0264 // SM100Status
|
||||
#define EMS_TYPE_SM100Status2 0x026A // SM100Status2
|
||||
#define EMS_TYPE_SM100Energy 0x028E // SM100Energy
|
||||
#define EMS_TYPE_HPMonitor1 0xE3 // HeatPump Monitor 1
|
||||
#define EMS_TYPE_HPMonitor2 0xE5 // HeatPump Monitor 2
|
||||
|
||||
#define EMS_TYPE_ISM1StatusMessage 0x0003 // Solar Module Junkers ISM1 Status
|
||||
#define EMS_TYPE_ISM1Set 0x0001 // for setting values of the solar module like max boiler temp
|
||||
#define EMS_OFFSET_ISM1Set_MaxBoilerTemp 6 // position of max boiler temp e.g. 50 in the following example: 90 30 FF 06 00 01 50 (CRC=2C)
|
||||
#define EMS_TYPE_ISM1StatusMessage 0x0003 // Solar Module Junkers ISM1 Status
|
||||
#define EMS_TYPE_ISM1Set 0x0001 // for setting values of the solar module like max boiler temp
|
||||
#define EMS_OFFSET_ISM1Set_MaxBoilerTemp 6 // position of max boiler temp e.g. 50 in the following example: 90 30 FF 06 00 01 50 (CRC=2C)
|
||||
|
||||
/*
|
||||
* Thermostats...
|
||||
@@ -219,7 +219,7 @@ const _Thermostat_Type Thermostat_Types[] = {
|
||||
{EMS_MODEL_RC20F, 93, 0x18, "RC20F", EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC30, 78, 0x10, "RC30/Nefit Moduline 400", EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC35, 86, 0x10, "RC35", EMS_THERMOSTAT_WRITE_YES},
|
||||
{EMS_MODEL_RC310, 158, 0x10, "RC3x0/Nefit Moduline 1010H", EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_RC310, 158, 0x10, "RC300/RC310/Nefit Moduline 1010/3000", EMS_THERMOSTAT_WRITE_NO},
|
||||
{EMS_MODEL_1010, 165, 0x18, "Nefit Moduline 1010", EMS_THERMOSTAT_WRITE_NO},
|
||||
|
||||
// Sieger
|
||||
|
||||
@@ -6,5 +6,5 @@
|
||||
#pragma once
|
||||
|
||||
#define APP_NAME "EMS-ESP"
|
||||
#define APP_VERSION "1.8.1b8"
|
||||
#define APP_VERSION "1.8.1b9"
|
||||