@@ -346,6 +346,7 @@ static void setup_commands(std::shared_ptr<Commands> & commands) {
|
||||
return StateUpdateResult::CHANGED;
|
||||
},
|
||||
"local");
|
||||
to_app(shell).uart_init();
|
||||
});
|
||||
|
||||
//
|
||||
|
||||
@@ -1149,8 +1149,8 @@ void Boiler::process_UBAFactory(std::shared_ptr<const Telegram> telegram) {
|
||||
void Boiler::process_UBAMonitorFast(std::shared_ptr<const Telegram> telegram) {
|
||||
has_update(telegram, selFlowTemp_, 0);
|
||||
has_update(telegram, curFlowTemp_, 1);
|
||||
has_update(telegram, selBurnPow_, 3); // burn power max setting
|
||||
has_update(telegram, curBurnPow_, 4);
|
||||
// has_update(telegram, selBurnPow_, 3); // burn power max setting
|
||||
// has_update(telegram, curBurnPow_, 4);
|
||||
has_update(telegram, boilerState_, 5); // bits 0-heat, 1-dhw, 2-service, 3-flame, 4-preheat, 5-lock-Err, 6-block-err, 7-maint
|
||||
has_bitupdate(telegram, burnGas_, 7, 0);
|
||||
has_bitupdate(telegram, burnGas2_, 7, 1);
|
||||
@@ -1184,7 +1184,20 @@ void Boiler::process_UBAMonitorFast(std::shared_ptr<const Telegram> telegram) {
|
||||
|
||||
has_update(telegram, serviceCodeNumber_, 20);
|
||||
|
||||
if (telegram->offset <= 4 && telegram->offset + telegram->message_length > 5) {
|
||||
if (telegram->offset <= 3 && telegram->offset + telegram->message_length > 7) {
|
||||
// some boiler only switch burnGas and have no other burner values, https://github.com/emsesp/EMS-ESP32/discussions/1483
|
||||
uint8_t selBurnPow = selBurnPow_;
|
||||
uint8_t curBurnPow = curBurnPow_;
|
||||
telegram->read_value(selBurnPow, 3);
|
||||
telegram->read_value(curBurnPow, 4);
|
||||
if (burnGas_ && selBurnPow == 0 && curBurnPow == 0) {
|
||||
boilerState_ |= 0x08; // set flame signal
|
||||
curBurnPow = 100;
|
||||
selBurnPow = 100;
|
||||
}
|
||||
has_update(selBurnPow_, selBurnPow);
|
||||
has_update(curBurnPow_, curBurnPow);
|
||||
|
||||
check_active(); // do a quick check to see if the hot water or heating is active
|
||||
}
|
||||
}
|
||||
@@ -1309,7 +1322,7 @@ void Boiler::process_UBAMonitorFastPlus(std::shared_ptr<const Telegram> telegram
|
||||
uint8_t syspress = sysPress_;
|
||||
telegram->read_value(syspress, 21); // 0 means no sensor
|
||||
if (syspress == 0) {
|
||||
sysPress_ = EMS_VALUE_UINT_NOTSET;
|
||||
syspress = EMS_VALUE_UINT_NOTSET;
|
||||
}
|
||||
has_update(sysPress_, syspress);
|
||||
|
||||
@@ -1475,7 +1488,9 @@ void Boiler::process_UBAMonitorWWPlus(std::shared_ptr<const Telegram> telegram)
|
||||
has_update(telegram, wwSetTemp_, 0);
|
||||
has_update(telegram, wwCurTemp_, 1);
|
||||
has_update(telegram, wwCurTemp2_, 3);
|
||||
has_update(telegram, wwCurFlow_, 11);
|
||||
if (!is_received(0x779)) { // HIUMonitor
|
||||
has_update(telegram, wwCurFlow_, 11);
|
||||
}
|
||||
|
||||
has_update(telegram, wwWorkM_, 14, 3); // force to 3 bytes
|
||||
has_update(telegram, wwStarts_, 17, 3); // force to 3 bytes
|
||||
|
||||
@@ -88,7 +88,7 @@ Heatpump::Heatpump(uint8_t device_type, uint8_t device_id, uint8_t product_id, c
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
|
||||
&hybridDHW_,
|
||||
DeviceValueType::ENUM,
|
||||
FL_(enum_comfort2),
|
||||
FL_(enum_comfort1),
|
||||
FL_(hybridDHW),
|
||||
DeviceValueUOM::NONE,
|
||||
MAKE_CF_CB(set_hybridDHW));
|
||||
@@ -332,7 +332,7 @@ bool Heatpump::set_lowNoiseStop(const char * value, const int8_t id) {
|
||||
}
|
||||
bool Heatpump::set_hybridDHW(const char * value, const int8_t id) {
|
||||
uint8_t v;
|
||||
if (!Helpers::value2enum(value, v, FL_(enum_comfort2))) {
|
||||
if (!Helpers::value2enum(value, v, FL_(enum_comfort1))) {
|
||||
return false;
|
||||
}
|
||||
write_command(0x998, 1, v, 0x998);
|
||||
|
||||
@@ -712,6 +712,15 @@ void Thermostat::process_RemoteHumidity(std::shared_ptr<const Telegram> telegram
|
||||
// has_update(telegram, dewtemperature_, 0); // this is int8
|
||||
has_update(telegram, humidity_, 1);
|
||||
has_update(telegram, dewtemperature_, 2); // this is int16
|
||||
// some thermostats use short telegram with int8 dewpoint, https://github.com/emsesp/EMS-ESP32/issues/1491
|
||||
if (telegram->offset == 0 && telegram->message_length < 4) {
|
||||
int8_t dew = dewtemperature_ / 10;
|
||||
telegram->read_value(dew, 0);
|
||||
if (dew != EMS_VALUE_INT_NOTSET && dewtemperature_ != dew * 10) {
|
||||
dewtemperature_ = dew * 10;
|
||||
has_update(dewtemperature_);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
// 0x273 - for reading temperaturcorrection from the RC100H remote thermostat (0x38, 0x39, ..)
|
||||
|
||||
@@ -216,6 +216,7 @@ void EMSESP::uart_init() {
|
||||
}
|
||||
|
||||
txservice_.start(); // sends out request to EMS bus for all devices
|
||||
txservice_.tx_mode(tx_mode);
|
||||
|
||||
// force a fetch for all new values, unless Tx is set to off
|
||||
if (tx_mode != 0) {
|
||||
|
||||
@@ -277,8 +277,8 @@ MAKE_ENUM(enum_charge, FL_(chargepump), FL_(3wayvalve))
|
||||
MAKE_ENUM(enum_freq, FL_(off), FL_(1x3min), FL_(2x3min), FL_(3x3min), FL_(4x3min), FL_(5x3min), FL_(6x3min), FL_(continuous))
|
||||
MAKE_ENUM(enum_off_time_date_manual, FL_(off), FL_(time), FL_(date), FL_(manual))
|
||||
MAKE_ENUM(enum_comfort, FL_(hot), FL_(eco), FL_(intelligent))
|
||||
MAKE_ENUM(enum_comfort1, FL_(high_comfort), FL_(eco))
|
||||
MAKE_ENUM(enum_comfort2, FL_(eco), FL_(high_comfort))
|
||||
// MAKE_ENUM(enum_comfort1, FL_(high_comfort), FL_(eco))
|
||||
MAKE_ENUM(enum_comfort1, FL_(eco), FL_(high_comfort))
|
||||
MAKE_ENUM(enum_flow, FL_(off), FL_(flow), FL_(bufferedflow), FL_(buffer), FL_(layeredbuffer))
|
||||
MAKE_ENUM(enum_reset, FL_(dash), FL_(maintenance), FL_(error))
|
||||
MAKE_ENUM(enum_maxHeat, FL_(0kW), FL_(2kW), FL_(3kW), FL_(4kW), FL_(6kW), FL_(9kW))
|
||||
|
||||