mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 16:29:51 +03:00
This commit is contained in:
@@ -5,7 +5,7 @@ All notable changes to this project will be documented in this file.
|
||||
The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.0.0/),
|
||||
and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0.html).
|
||||
|
||||
## [1.8.1dev] 2019-06-24
|
||||
## [1.8.1dev] 2019-07-01
|
||||
|
||||
### Added
|
||||
|
||||
@@ -19,11 +19,13 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
|
||||
|
||||
- Detecting unset values in the SPIFFS and setting default values
|
||||
- Bosch Easy Connect wrongly classified as a thermostat
|
||||
- Correctly handle telegrams who's size are exactly 32 bytes (e.g. 0x19 MonitorSlow)
|
||||
|
||||
### Changed
|
||||
|
||||
- Improved handling of Solar Modules (thanks @Vuego123)
|
||||
- `publish_wait` renamed to `publish_time`, a value of 0 means disabling all MQTT sending
|
||||
- How signed shorts are handled such as the current and setpoint temps on RC300s
|
||||
|
||||
## [1.8.0] 2019-06-15
|
||||
|
||||
|
||||
@@ -69,7 +69,7 @@ static void ICACHE_FLASH_ATTR emsuart_recvTask(os_event_t * events) {
|
||||
if (length == 2) {
|
||||
// it's a poll or status code, single byte and ok to send on
|
||||
ems_parseTelegram((uint8_t *)pCurrent->buffer, 1);
|
||||
} else if ((length > 4) && (length <= EMS_MAXBUFFERSIZE) && (pCurrent->buffer[length - 2] != 0x00)) {
|
||||
} else if ((length > 4) && (length <= EMS_MAXBUFFERSIZE + 1) && (pCurrent->buffer[length - 2] != 0x00)) {
|
||||
// ignore double BRK at the end, possibly from the Tx loopback
|
||||
// also telegrams with no data value
|
||||
ems_parseTelegram((uint8_t *)pCurrent->buffer, length - 1); // transmit EMS buffer, excluding the BRK
|
||||
|
||||
@@ -50,7 +50,8 @@ static const char * TEST_DATA[] = {
|
||||
"08 00 E3 00 01 00 01 00 00 00 00 00 00 00 00 00 DF 00 64 55", // test 45 - heatpump Enviline
|
||||
"08 00 E5 00 00 00 20 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0A", // test 46 - heatpump Enviline
|
||||
"38 10 FF 00 03 2B 00 C7 07 C3 01", // test 47 - heatpump Enviline
|
||||
"08 0B 19 00 00 F7 80 00 80 00 00 00 00 00 03 58 97 0C 7B 1F 00 00 00 06 C4 DF 02 64 48 80 00" // test 48 - outdoor temp check
|
||||
"08 0B 19 00 00 F7 80 00 80 00 00 00 00 00 03 58 97 0C 7B 1F 00 00 00 06 C4 DF 02 64 48 80 00", // test 48 - outdoor temp check
|
||||
"88 00 19 00 00 DC 80 00 80 00 FF FF 00 00 00 21 9A 06 E1 7C 00 00 00 06 C2 13 00 1E 90 80 00" // test 49 - check max length
|
||||
|
||||
|
||||
};
|
||||
|
||||
Reference in New Issue