Paul Derbyshire
2019-07-15 10:54:15 +02:00
parent 2f4d58bef4
commit 7b6dc38c3d
3 changed files with 15 additions and 9 deletions

View File

@@ -1300,9 +1300,7 @@ void _process_RCPLUSStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
EMS_Thermostat.day_mode = _bitRead(EMS_OFFSET_RCPLUSGet_mode_day, 1); // get day mode flag
// room night setpoint is _toByte(2) (value is *2)
// boiler set temp is _toByte(4) (value is *2)
// day night is byte(8), 0x01 for night, 0x00 for day
EMS_Thermostat.mode = _bitRead(EMS_OFFSET_RCPLUSStatusMessage_mode, 1); // bit 1, mode (auto or manual)
}
// actual set point
@@ -1316,6 +1314,13 @@ void _process_RCPLUSStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
if (EMS_RxTelegram->offset == 6) {
// to add...
}
// thermostat mode auto/manual, examples:
// manual : 10 00 FF 0A 01 A5 02 (CRC=16) #data=1
// auto : Thermostat -> all, type 0x01A5 telegram: 10 00 FF 0A 01 A5 03 (CRC=17) #data=1
if (EMS_RxTelegram->offset == EMS_OFFSET_RCPLUSStatusMessage_mode) {
EMS_Thermostat.mode = _bitRead(0, 1); // bit 1
}
}
/**
@@ -1480,18 +1485,18 @@ void _process_SM100Energy(_EMS_RxTelegram * EMS_RxTelegram) {
* Type 0xE3 - HeatPump Monitor 1
*/
void _process_HPMonitor1(_EMS_RxTelegram * EMS_RxTelegram) {
EMS_HeatPump.HPModulation = _toByte(14); // modulation %
EMS_HeatPump.HPModulation = _toByte(14); // modulation %
EMS_Sys_Status.emsRefreshed = true; // triggers a send the values back via MQTT
EMS_Sys_Status.emsRefreshed = true; // triggers a send the values back via MQTT
}
/*
* Type 0xE5 - HeatPump Monitor 2
*/
void _process_HPMonitor2(_EMS_RxTelegram * EMS_RxTelegram) {
EMS_HeatPump.HPSpeed = _toByte(25); // speed %
EMS_Sys_Status.emsRefreshed = true; // triggers a send the values back via MQTT
EMS_HeatPump.HPSpeed = _toByte(25); // speed %
EMS_Sys_Status.emsRefreshed = true; // triggers a send the values back via MQTT
}
/*

View File

@@ -112,6 +112,7 @@
#define EMS_OFFSET_RCPLUSStatusMessage_setpoint 3 // setpoint temp
#define EMS_OFFSET_RCPLUSStatusMessage_curr 0 // current temp
#define EMS_OFFSET_RCPLUSGet_mode_day 8 // day/night mode
#define EMS_OFFSET_RCPLUSStatusMessage_mode 0x0A // thermostat mode (auto, manual)
// Junkers FR10, FW100 (EMS Plus)
#define EMS_TYPE_JunkersStatusMessage 0x6F // is an automatic thermostat broadcast giving us temps

View File

@@ -6,5 +6,5 @@
#pragma once
#define APP_NAME "EMS-ESP"
#define APP_VERSION "1.8.1b15"
#define APP_VERSION "1.8.1b16"
#define APP_HOSTNAME "ems-esp"