@@ -81,11 +81,10 @@ void Connect::process_RCTime(std::shared_ptr<const Telegram> telegram) {
|
||||
has_update(dateTime_, time, sizeof(dateTime_));
|
||||
}
|
||||
|
||||
/* other values from 0x50 RF base
|
||||
(0x087F), data: 00 00
|
||||
(0x0880), data: 01 04
|
||||
(0x0889), data: 00 80 80 01
|
||||
*/
|
||||
// other values from 0x50 RF base
|
||||
// (0x087F), data: 00 00
|
||||
// (0x0880), data: 01 04
|
||||
// (0x0889), data: 00 80 80 01
|
||||
void Connect::register_device_values_room(std::shared_ptr<Connect::RoomCircuit> room) {
|
||||
auto tag = DeviceValueTAG::TAG_SRC1 + room->room();
|
||||
register_device_value(tag, &room->temp_, DeviceValueType::INT16, DeviceValueNumOp::DV_NUMOP_DIV10, FL_(roomTemp), DeviceValueUOM::DEGREES);
|
||||
|
||||
@@ -563,21 +563,19 @@ void Solar::process_SM100Differential(std::shared_ptr<const Telegram> telegram)
|
||||
has_update(telegram, diffControl_, 0); // is *10
|
||||
}
|
||||
|
||||
/* process_SM100ParamCfg - type 0xF9 EMS 1.0
|
||||
* This telegram is used to inquire the min, default, max, and current values of a value that is usually read and written with another telegram ID
|
||||
* The CS200 uses this method extensively to find out which values may be set in the SM100
|
||||
* e.g. B0 10 F9 00 FF 02 5A 03 17 00 00 00 14 00 00 00 3C 00 00 00 5A 00 00 00 59 29 - requested with 90 B0 F9 00 11 FF 02 5A 03 AF
|
||||
* byte 0 = 0xFF
|
||||
* byte 1-2 = telegram ID used to write this value
|
||||
* byte 3 = offset in telegram used to write this value
|
||||
* byte 4 = unknown
|
||||
* bytes 5..8 = minimum value
|
||||
* bytes 9..12 = default value
|
||||
* bytes 13..16 = maximum value
|
||||
* bytes 17..20 = current value
|
||||
*
|
||||
* e.g. B0 0B F9 00 00 02 5A 00 00 6E
|
||||
*/
|
||||
// process_SM100ParamCfg - type 0xF9 EMS 1.0
|
||||
// This telegram is used to inquire the min, default, max, and current values of a value that is usually read and written with another telegram ID
|
||||
// The CS200 uses this method extensively to find out which values may be set in the SM100
|
||||
// e.g. B0 10 F9 00 FF 02 5A 03 17 00 00 00 14 00 00 00 3C 00 00 00 5A 00 00 00 59 29 - requested with 90 B0 F9 00 11 FF 02 5A 03 AF
|
||||
// byte 0 = 0xFF
|
||||
// byte 1-2 = telegram ID used to write this value
|
||||
// byte 3 = offset in telegram used to write this value
|
||||
// byte 4 = unknown
|
||||
// bytes 5..8 = minimum value
|
||||
// bytes 9..12 = default value
|
||||
// bytes 13..16 = maximum value
|
||||
// bytes 17..20 = current value
|
||||
// e.g. B0 0B F9 00 00 02 5A 00 00 6E
|
||||
void Solar::process_SM100ParamCfg(std::shared_ptr<const Telegram> telegram) {
|
||||
uint16_t t_id = EMS_VALUE_UINT16_NOTSET;
|
||||
uint8_t of = EMS_VALUE_UINT8_NOTSET;
|
||||
|
||||
@@ -51,68 +51,6 @@ class Ventilation : public EMSdevice {
|
||||
bool set_ventMode(const char * value, const int8_t id);
|
||||
bool set_bypass(const char * value, const int8_t id);
|
||||
bool set_filter(const char * value, const int8_t id);
|
||||
|
||||
|
||||
/* Sensors:
|
||||
outdoor air temp (außenluft)
|
||||
supply air temp (zuluft)
|
||||
extract air temp (abluft)
|
||||
away air temp (fortluft)
|
||||
supply blower (zuluftgebläse)
|
||||
supply blower mod (zuluftebläse drehzahl)
|
||||
away blower (abluftgebläse)
|
||||
away blower mod (abluftgebläse drehzahl)
|
||||
Anschlussvariante
|
||||
el. vorheizer
|
||||
ext. el. vorheizreg.
|
||||
nachheiz zulufttemp
|
||||
mischer öffnen
|
||||
mischer schließen
|
||||
mischerposition
|
||||
zuluft temp soll
|
||||
zuluft temp ist
|
||||
leistung nachheizreg.
|
||||
erdwärmetauscher klappe
|
||||
solekreispumpe
|
||||
abluftfeuchte
|
||||
abluftqualität
|
||||
raumluftfechte
|
||||
raumluftqualität
|
||||
luftfeuchte fernbed. 1..4
|
||||
*/
|
||||
/* Parameters:
|
||||
Gerätetyp,
|
||||
Nennvolumentstrom,
|
||||
Filterlaufzeit 1-6-12 m
|
||||
Filterwechsel confirm CMD
|
||||
Lüftungsfrostschutz: _el._preheat_, Disballance | Interval
|
||||
Ext. Frostschutz: on/_off_
|
||||
Bypass _on_, off
|
||||
min. outdoortemp 12 15 19 °C
|
||||
max. outdoortemp 21-24-30 C
|
||||
Enthalpie Wärmetauscher instaliert nein-ja
|
||||
Feuchteschutz AUs/ 1-24 h
|
||||
Lüfterstufe 1-4, Drehzahlanpassung
|
||||
ext. Luftfeuchtefühler inst.? _nein_, ja
|
||||
Abluftfeuchtefühler inst.? _nein_, ja
|
||||
Luftfeuchte Fernbed. _nein_, ja
|
||||
Luftfeuchte: trocken, _normal_, feucht
|
||||
Abluftqualitätsfühler inst. _ja_, nein
|
||||
ext. Luftqualfühl? _nein_, ja
|
||||
Lufqualität: ausreichend, _normal_, hoch
|
||||
el. Nachheizregister inst. _nein_, ja
|
||||
Nachheiz-Zuluft temp: 10-22-30 °C
|
||||
Erdwärmetauscher inst? _nein_, Luft, Sole
|
||||
Taster Funktion: nein, einschlafen, intensiv, bypass, party, kamin
|
||||
ext. Störung aktivieren: _nein_, ja, invertiert
|
||||
Dauer einschlafen: 15-60-120 min
|
||||
Dauer Intensiv: 5-15-60 min
|
||||
Dauer Bypass Abluft: 1-8-12 h
|
||||
Dauer Bypass: 1-8-12 h
|
||||
Dauer PArty 1-8-12 h
|
||||
Dauer Kamin: 5-10-15 min
|
||||
Volumenstromabgleich 90-100-110 %
|
||||
*/
|
||||
};
|
||||
|
||||