mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-06 07:49:52 +03:00
add RC300 thermostat temp -1 to clear temporary setpoint
This commit is contained in:
@@ -16,6 +16,7 @@
|
||||
- Added in MQTT nested mode, for thermostat and mixer, like we had back in v2
|
||||
- Cascade MC400 (product-id 210) (3.0.0b6)
|
||||
- values for wwMaxPower, wwFlowtempOffset
|
||||
- RC300 `thermostat temp -1` to clear temporary setpoint in auto mode
|
||||
|
||||
### Fixed
|
||||
- telegrams matched to masterthermostat 0x18
|
||||
|
||||
@@ -1731,6 +1731,10 @@ bool Thermostat::set_temperature(const float temperature, const uint8_t mode, co
|
||||
offset = 0x0A; // manual offset
|
||||
} else {
|
||||
offset = 0x08; // auto offset
|
||||
// special case to reactivate auto temperature, see #737, #746
|
||||
if (temperature == -1) {
|
||||
factor = 0xFF; // use factor as value
|
||||
}
|
||||
}
|
||||
validate_typeid = monitor_typeids[hc->hc_num() - 1]; // get setpoint roomtemp back
|
||||
break;
|
||||
@@ -1887,7 +1891,11 @@ bool Thermostat::set_temperature(const float temperature, const uint8_t mode, co
|
||||
|
||||
// add the write command to the Tx queue. value is *2
|
||||
// post validate is the corresponding monitor or set type IDs as they can differ per model
|
||||
write_command(set_typeid, offset, (uint8_t)((float)temperature * (float)factor), validate_typeid);
|
||||
if (factor == 0xFF) {
|
||||
write_command(set_typeid, offset, factor, validate_typeid);
|
||||
} else {
|
||||
write_command(set_typeid, offset, (uint8_t)((float)temperature * (float)factor), validate_typeid);
|
||||
}
|
||||
return true;
|
||||
}
|
||||
|
||||
|
||||
Reference in New Issue